MRMax Rose

Max Rose

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Max Rose has a total of 158 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Top Cited Papers
    Open Access

    Observation of a single protein by ultrafast X-ray diffraction

    by Tomas Ekeberg, Dameli Assalauova, Johan Bielecki, Rebecca Boll, Benedikt J. Daurer, Lutz A. Eichacker, Linda E. Franken, Davide E. Galli, Luca Gelisio, Lars Gumprecht, et al.

    The idea of using ultrashort X-ray pulses to obtain images of single proteins frozen in time has fascinated and inspired many. It was one of the arguments for building X-ray free-electron lasers. According to theory, the extremely intense pulses provide sufficient signal to dispense with using crystals as an amplifier, and the ultrashort pulse duration permits capturing the diffraction data before the sample inevitably explodes. This was first demonstrated on biological samples a decade ago on the giant mimivirus. Since then, a large collaboration has been pushing the limit of the smallest sample that can be imaged. The ability to capture snapshots on the timescale of atomic vibrations, while keeping the sample at room temperature, may allow probing the entire conformational phase space of macromolecules. Here we show the first observation of an X-ray diffraction pattern from a single protein, that of Escherichia coli GroEL which at 14 nm in diameter is the smallest biological sample ever imaged by X-rays, and demonstrate that the concept of diffraction before destruction extends to single proteins. From the pattern, it is possible to determine the approximate orientation of the protein. Our experiment demonstrates the feasibility of ultrafast imaging of single proteins, opening the way to single-molecule time-resolved studies on the femtosecond timescale.


  • Open Access

    An advanced workflow for single-particle imaging with the limited data at an X-ray free-electron laser. Corrigendum

    by Dameli Assalauova, Young Yong Kim, Sergey Bobkov, Ruslan Khubbutdinov, Max Rose, Roberto Alvarez, Jakob Andreasson, Eugeniu Balaur, Alice Contreras, Hasan DeMirci, et al.

    An error in Fig. 3(c) of the article by Assalauova et al. [IUCrJ (2020), 7, 1102–1113] is corrected.


  • Open Access

    An advanced workflow for single-particle imaging with the limited data at an X-ray free-electron laser

    by Dameli Assalauova, Young Yong Kim, Sergey Bobkov, Ruslan Khubbutdinov, Max Rose, Roberto Alvarez, Jakob Andreasson, Eugeniu Balaur, Alice Contreras, Hasan DeMirci, et al.

    An improved analysis for single-particle imaging (SPI) experiments, using the limited data, is presented here. Results are based on a study of bacteriophage PR772 performed at the Atomic, Molecular and Optical Science instrument at the Linac Coherent Light Source as part of the SPI initiative. Existing methods were modified to cope with the shortcomings of the experimental data: inaccessibility of information from half of the detector and a small fraction of single hits. The general SPI analysis workflow was upgraded with the expectation-maximization based classification of diffraction patterns and mode decomposition on the final virus-structure determination step. The presented processing pipeline allowed us to determine the 3D structure of bacteriophage PR772 without symmetry constraints with a spatial resolution of 6.9 nm. The obtained resolution was limited by the scattering intensity during the experiment and the relatively small number of single hits.


  • Open Access

    Megahertz single-particle imaging at the European XFEL

    by Egor Sobolev, Sergei Zolotarev, Klaus Giewekemeyer, Johan Bielecki, Kenta Okamoto, Hemanth K. N. Reddy, Jakob Andreasson, Kartik Ayyer, Imrich Barak, Sadia Bari, et al.

    The emergence of high repetition-rate X-ray free-electron lasers (XFELs) powered by superconducting accelerator technology enables the measurement of significantly more experimental data per day than was previously possible. The European XFEL is expected to provide 27,000 pulses per second, over two orders of magnitude more than any other XFEL. The increased pulse rate is a key enabling factor for single-particle X-ray diffractive imaging, which relies on averaging the weak diffraction signal from single biological particles. Taking full advantage of this new capability requires that all experimental steps, from sample preparation and delivery to the acquisition of diffraction patterns, are compatible with the increased pulse repetition rate. Here, we show that single-particle imaging can be performed using X-ray pulses at megahertz repetition rates. The results obtained pave the way towards exploiting high repetition-rate X-ray free-electron lasers for single-particle imaging at their full repetition rate.


  • Open Access

    Soft X-ray diffraction patterns measured by a LiF detector with sub-micrometre resolution and an ultimate dynamic range

    by Sergey Makarov, Sergey Pikuz, Sergey Ryazantsev, Tatiana Pikuz, Alexey Buzmakov, Max Rose, Sergey Lazarev, Tobias Senkbeil, Andreas von Gundlach, Susan Stuhr, et al.

    The unique diagnostic possibilities of X-ray diffraction, small X-ray scattering and phase-contrast imaging techniques applied with high-intensity coherent X-ray synchrotron and X-ray free-electron laser radiation can only be fully realized if a sufficient dynamic range and/or spatial resolution of the detector is available. In this work, it is demonstrated that the use of lithium fluoride (LiF) as a photoluminescence (PL) imaging detector allows measuring of an X-ray diffraction image with a dynamic range of ∼107 within the sub-micrometre spatial resolution. At the PETRA III facility, the diffraction pattern created behind a circular aperture with a diameter of 5 µm irradiated by a beam with a photon energy of 500 eV was recorded on a LiF crystal. In the diffraction pattern, the accumulated dose was varied from 1.7 × 105 J cm−3 in the central maximum to 2 × 10−2 J cm−3 in the 16th maximum of diffraction fringes. The period of the last fringe was measured with 0.8 µm width. The PL response of the LiF crystal being used as a detector on the irradiation dose of 500 eV photons was evaluated. For the particular model of laser-scanning confocal microscope Carl Zeiss LSM700, used for the readout of the PL signal, the calibration dependencies on the intensity of photopumping (excitation) radiation (λ = 488 nm) and the gain have been obtained.


  • Open Access

    Structural Changes in a Single GaN Nanowire under Applied Voltage Bias

    by Sergey Lazarev, Dmitry Dzhigaev, Zhaoxia Bi, Ali Nowzari, Young Yong Kim, Max Rose, Ivan A. Zaluzhnyy, Oleg Yu. Gorobtsov, Alexey V. Zozulya, Filip Lenrick, et al.

    GaN nanowires (NWs) are promising building blocks for future optoelectronic devices and nanoelectronics. They exhibit stronger piezoelectric properties than bulk GaN. This phenomena may be crucial for applications of NWs and makes their study highly important. We report on an investigation of the structure evolution of a single GaN NW under an applied voltage bias along polar [0001] crystallographic direction until its mechanical break. The structural changes were investigated using coherent X-ray Bragg diffraction. The three-dimensional (3D) intensity distributions of the NWs without metal contacts, with contacts, and under applied voltage bias in opposite polar directions were analyzed. Coherent X-ray Bragg diffraction revealed the presence of significant bending of the NWs already after metal contacts deposition, which was increased at applied voltage bias. Employing analytical simulations based on elasticity theory and a finite element method (FEM) approach, we developed a 3D model of the NW bending under applied voltage. From this model and our experimental data, we determined the piezoelectric constant of the GaN NW to be about 7.7 pm/V in [0001] crystallographic direction. The ultimate tensile strength of the GaN NW was obtained to be about 1.22 GPa. Our work demonstrates the power of in operando X-ray structural studies of single NWs for their effective design and implementation with desired functional properties.


  • Open Access

    Quantitative ptychographic bio-imaging in the water window

    by Max Rose, Tobias Senkbeil, Andreas R. von Gundlach, Susan Stuhr, Christoph Rumancev, Dmitry Dzhigaev, Ilya Besedin, Petr Skopintsev, Lars Loetgering, Jens Viefhaus, et al.

    Coherent X-ray ptychography is a tool for highly dose efficient lensless nano-imaging of biological samples. We have used partially coherent soft X-ray synchrotron radiation to obtain a quantitative image of a laterally extended, dried, and unstained fibroblast cell by ptychography. We used data with and without a beam stop that allowed us to measure coherent diffraction with a high-dynamic range of 1.7·106. As a quantitative result, we obtained the refractive index values for two regions of the cell with respect to a reference area. Due to the photon energy in the water window we obtained an extremely high contrast of 53% at 71 nm half-period resolution. The dose applied in our experiment was 9.5·104 Gy and is well below the radiation damage threshold. The concept for dynamic range improvement for low dynamic range detectors with a beam stop opens the path for high resolution nano-imaging of a variety of samples including cryo-preserved, hydrated and unstained biological cells.


  • Open Access

    High-dynamic-range water window ptychography

    by Max Rose, Dmitry Dzhigaev, Tobias Senkbeil, Andreas R. von Gundlach, Susan Stuhr, Christoph Rumancev, Ilya Besedin, Petr Skopintsev, Jens Viefhaus, Axel Rosenhahn, et al.

    Ptychographic imaging with soft X-rays, especially in the water window energy range, suffers from limited detector dynamic range that directly influences the maximum spatial resolution achievable. High-dynamic-range data can be obtained by multiple exposures. By this approach we have increased the dynamic range of a ptychographic data set by a factor of 76 and obtained diffraction signal till the corners of the detector. The real space half period resolution was improved from 50 nm for the single exposure data to 18 nm for the high-dynamic-range data.


  • Open Access

    High-dynamic-range water window ptychography

    by Max Rose, Dmitry Dzhigaev, Tobias Senkbeil, Andreas R. von Gundlach, Susan Stuhr, Christoph Rumancev, Ilya Besedin, Petr Skopintsev, Jens Viefhaus, Axel Rosenhahn, et al.

    Ptychographic imaging with soft X-rays, especially in the water window energy range, suffers from limited detector dynamic range that directly influences the maximum spatial resolution achievable. High-dynamic-range data can be obtained by multiple exposures. By this approach we have increased the dynamic range of a ptychographic data set by a factor of 76 and obtained diffraction signal till the corners of the detector. The real space half period resolution was improved from 50 nm for the single exposure data to 18 nm for the high-dynamic-range data.