LGLeroy Grob

Leroy Grob

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Leroy Grob has a total of 50 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Low‐Cost, On‐Site, Nano‐Impact Detection of Silver Nanoparticles via Laser‐Ablated Screen‐Printed Microelectrodes

    by Leroy Grob, Lennart J. K. Weiß, Emir Music, Ilja Schwertfeger, George Al Boustani, Julian Feuerbach, Marta Nikić, Lukas Hiendlmeier, Philipp Rinklin, Bernhard Wolfrum

    With the ever‐growing presence of silver nanoparticles in consumer products, there is a need for cost‐effective and on‐site monitoring of their influence on our environment. Herein, we report the use of screen‐printed and laser‐ablated microelectrode arrays (SPMEAs) for the electrochemical detection of 20 nm‐sized silver nanoparticles (AgNPs) via collision electrochemistry. The electrodes’ morphology is optically analyzed and their electrochemical properties later characterized using cyclic voltammetry and impedance spectroscopy. The SPMEAs are calibrated using a AgNP concentration range of 1 to 100 pM, resulting in a linear dependency of 22 mHz pM−1 for the impact frequency. Finally, to demonstrate the possibility of future on‐site applications, an in‐house built portable nanoparticle detection (POND) device is used to measure Faradaic AgNP impacts on a SPMEA, in a solution contaminated with urea.


  • Open Access

    Determination of Stiffness and the Elastic Modulus of 3D-Printed Micropillars with Atomic Force Microscopy–Force Spectroscopy

    by Giorgio Cortelli, Leroy Grob, Luca Patruno, Tobias Cramer, Dirk Mayer, Beatrice Fraboni, Bernhard Wolfrum, Stefano de Miranda

    Nowadays, many applications in diverse fields are taking advantage of micropillars such as optics, tribology, biology, and biomedical engineering. Among them, one of the most attractive is three-dimensional microelectrode arrays for in vivo and in vitro studies, such as cellular recording, biosensors, and drug delivery. Depending on the application, the micropillar's optimal mechanical response ranges from soft to stiff. For long-term implantable devices, a mechanical mismatch between the micropillars and the biological tissue must be avoided. For drug delivery patches, micropillars must penetrate the skin without breaking or bending. The accurate mechanical characterization of the micropillar is pivotal in the fabrication and optimization of such devices, as it determines whether the device will fail or not. In this work, we demonstrate an experimental method based only on atomic force microscopy-force spectroscopy that allows us to measure the stiffness of a micropillar and the elastic modulus of its constituent material. We test our method with four different types of 3D inkjet-printed micropillars: silver micropillars sintered at 100 and 150 °C and polyacrylate microstructures with and without a metallic coating. The estimated elastic moduli are found to be comparable with the corresponding bulk values. Furthermore, our findings show that neither the sintering temperature nor the presence of a thin metal coating plays a major role in defining the mechanical properties of the micropillar.


  • Open Access

    Fully 3D‐Printed Cuff Electrode for Small Nerve Interfacing

    by Francisco Zurita, Leroy Grob, Amelie Erben, Fulvia Del Duca, Hauke Clausen‐Schaumann, Stefanie Sudhop, Oliver Hayden, Bernhard Wolfrum

    Interfacing with the peripheral nervous system is a powerful method for diagnosing and treating several diseases, such as drug‐resistant epilepsy and depression. In most clinical applications, large nerves such as the vagus and the hypoglossal nerve are targeted. Large nerves carry multiple nerve fibers, and maintaining selectivity of a specific target response demands complex stimulation strategies. As the large trunks bifurcate toward their distal ends, their diameter and number of comprised fibers reduce. Consequently, interfacing small nerves can provide increased fiber selectivity. However, their small size presents challenges to the fabrication and implantation of suitable electrodes due to their fragility and constrained environments. Here, a cuff electrode that combines two‐photon stereolithography and 3D inkjet printing techniques for the selective interfacing of small nerves in vivo is introduced. The device is easy to implant, and its size can be tailored for specific nerve dimensions. Its capability to record and selectively stimulate is demonstrated by targeting a locust's hind leg nerve.


  • Engineering Electrostatic Repulsion of Metal Nanoparticles for Reduced Adsorption in Single-Impact Electrochemical Recordings

    by Lennart J. K. Weiß, Emir Music, Philipp Rinklin, Lea Straumann, Leroy Grob, Dirk Mayer, Bernhard Wolfrum


  • Open Access

    3D Printing of Implants Composed of Nanjing Tamasudare‐Inspired Flexible Shape Transformers

    by Tetsuhiko F. Teshima, Lukas Hiendlmeier, Korkut Terkan, Sabine Zips, Leroy Grob, Francisco Zurita, Philipp Rinklin, Bernhard Wolfrum

    Minimizing damage during the insertion of stents or other medical devices is critical for rapid and successful recovery. Since the delivery passages are often narrower than the size of the delivered object, a high deformability of the implanted devices is paramount to achieve a smooth insertion into the target tissue. In this study, a novel design of 3D‐printable and highly deformable structures inspired by Nanjing Tamasudare is proposed. These structures rapidly change dimensionality from flat to linear, elongated shapes. A series of single units that each comprises two interconnected rods and attaching loops are directly 3D‐printed without classical assembly or fabrication. Multiple units are connected together but remain individually movable and deformable. The smooth changes of the unit assembly, including shifting, bending, and inclination, allow to transform the structure from an initially condensed state to various types of target shapes. To verify the transformation capabilities, smooth insertion of the 3D‐printed structure in a mock‐up vessel through a small opening in an elongated state is demonstrated. After insertion, the units are reassembled to a stent‐like structure within the vessel. The authors believe that this 3D‐printable and highly transformable design is widely applicable for insertion operations of implantable devices or electronics.


  • Open Access

    Inkjet-Printed and Electroplated 3D Electrodes for Recording Extracellular Signals in Cell Culture

    by Leroy Grob, Philipp Rinklin, Sabine Zips, Dirk Mayer, Sabrina Weidlich, Korkut Terkan, Lennart J. K. Weiß, Nouran Adly, Andreas Offenhäusser, Bernhard Wolfrum

    Recent investigations into cardiac or nervous tissues call for systems that are able to electrically record in 3D as opposed to 2D. Typically, challenging microfabrication steps are required to produce 3D microelectrode arrays capable of recording at the desired position within the tissue of interest. As an alternative, additive manufacturing is becoming a versatile platform for rapidly prototyping novel sensors with flexible geometric design. In this work, 3D MEAs for cell-culture applications were fabricated using a piezoelectric inkjet printer. The aspect ratio and height of the printed 3D electrodes were user-defined by adjusting the number of deposited droplets of silver nanoparticle ink along with a continuous printing method and an appropriate drop-to-drop delay. The Ag 3D MEAs were later electroplated with Au and Pt in order to reduce leakage of potentially cytotoxic silver ions into the cellular medium. The functionality of the array was confirmed using impedance spectroscopy, cyclic voltammetry, and recordings of extracellular potentials from cardiomyocyte-like HL-1 cells.


  • Open Access

    An Investigation into the Intrinsic Peroxidase‐Like Activity of Fe‐MOFs and Fe‐MOFs/Polymer Composites

    by Bhawana Thakur, Vikram V. Karve, Daniel T. Sun, A. Lisa Semrau, Lennart J. K. Weiß, Leroy Grob, Roland A. Fischer, Wendy L. Queen, Bernhard Wolfrum

    The quest for developing materials that provide a perfect trade‐off between factors such as enzyme‐like response, stability, and low cost has been a long‐standing challenge in the field of biosensing. Metal‐organic frameworks (MOFs) and their composites have emerged as promising candidates for biosensing applications due to their exceptional properties such as tunable pore size, high specific surface area, and exposed active sites. A comparative study of the intrinsic peroxidase‐like activity of five different MOF materials: Fe‐BTC, NH2‐MIL‐101(Fe), composites of Fe‐BTC with polymers polydopamine (PDA), poly p‐phenylenediamine (PpPDA), and poly(3,4‐ethylenedioxythiophene) is reported for the detection of H2O2, an important biomarker in biomedical diagnostics. The response of these materials toward H2O2 via electrochemical and colorimetric techniques is mapped and it is found that, at neutral pH, the Fe‐BTC/PEDOT composite exhibits the highest sensitivity and activity compared to other MOF materials in this study. The results indicate that the combination of unique properties of Fe‐BTC and conducting polymer PEDOT, improves the peroxidase‐like activity of the Fe‐BTC/PEDOT composite compared to the individual components. This work presents a new opportunity for easy‐to synthesize and low‐cost MOFs/conducting polymer composites for biosensing applications and provides significant insights to achieve rational design of composites with desirable functional properties


  • Open Access

    Electronic design automation for increased robustness in inkjet-printed electronics

    by Philipp Rinklin, Tsun-Ming Tseng, Cai Liu, Mengchu Li, Korkut Terkan, Leroy Grob, Nouran Adly, Sabine Zips, Lennart Weiß, Ulf Schlichtmann, et al.

    Printed electronics is of great interest for low-cost, large-area fabrication due to fast and scalable processes with low material consumption. However, notable resources are currently required for fine-tuning layout designs and process parameters to prevent unintended fabrication artifacts. This study proposes the use of electronic design automation to mitigate such artifacts by segmenting input layouts and arranging the resulting objects in separate conflict-free layers. To this end, two exemplary conflicts with relevance for inkjet printing are defined. The first addresses heterogeneous structures composed of low- and high-resolution features. The second is concerned with layouts requiring a high feature density. Experimental data is used to derive constraints for layer arrangement. Finally, mixed-integer-linear programming is used to formally model the problem and minimize the total number of layers under the aforementioned constraints. The results of printing test layouts with and without algorithmic treatment are characterized in terms of film morphology, device functionality, and fabrication yield. The data demonstrates a more consistent fabrication outcome and significantly increased yields for optimized fabrication batches compared to non-optimized ones. The final processing of the layouts requires no human intervention and can readily be transferred to a variety of ink–substrate systems.


  • Open Access

    Printed 3D Electrode Arrays with Micrometer‐Scale Lateral Resolution for Extracellular Recording of Action Potentials

    by Leroy Grob, Hideaki Yamamoto, Sabine Zips, Philipp Rinklin, Ayumi Hirano‐Iwata, Bernhard Wolfrum

    Current investigations on neuronal or cardiac tissues call for systems that can electrically monitor cellular activity in three dimensions as opposed to classical planar approaches. Typically the fabrication of such 3D microelectrode arrays (3D MEAs) relies on advanced cleanroom fabrication techniques. However, additive manufacturing is becoming an ever versatile alternative for rapid prototyping of novel sensor designs due to its low cost and material expense. Here, the possibility of fabricating high‐resolution 3D MEAs is demonstrated by using electrohydrodynamic inkjet printing. The height and aspect ratio of the 3D electrodes can be readily tuned by adjusting the printing conditions and number of deposited ink droplets per electrode. The fabrication of pillar electrode arrays with electrode diameters of sintered structures below 3 µm is shown. The functionality of the array is confirmed using impedance spectroscopy and extracellular recordings of action potentials from HL‐1 cells.


  • Fully Printed μ-Needle Electrode Array from Conductive Polymer Ink for Bioelectronic Applications

    by Sabine Zips, Leroy Grob, Philipp Rinklin, Korkut Terkan, Nouran Yehia Adly, Lennart Jakob Konstantin Weiß, Dirk Mayer, Bernhard Wolfrum

    Microelectrode arrays (MEAs) are widely used platforms in bioelectronics to study electrogenic cells. In recent years, the processing of conductive polymers for the fabrication of three-dimensional electrode arrays has gained increasing interest for the development of novel sensor designs. Here, additive manufacturing techniques are promising tools for the production of MEAs with three-dimensional electrodes. In this work, a facile additive manufacturing process for the fabrication of MEAs that feature needle-like electrode tips – so called µ-needles – is presented. To this end, an aerosol-jet compatible PEDOT:PSS and multi-walled carbon nanotube composite ink with a conductivity of 323±75 S m-1 is developed and used in a combined inkjet and aerosol-jet printing process to produce the µ-needle electrode features. The µ-needles are fabricated with a diameter of 10±2 µm and a height of 33±4 µm. They penetrate an inkjet-printed dielectric layer to a height of 12±3 µm. After successful printing, the electrochemical properties of the devices are assessed via cyclic voltammetry and impedance spectroscopy. The µ-needles show a capacitance of 242±70 nF at a scan rate of 5 mV s-1 and an impedance of 128±22 kΩ at 1 kHz frequency. The stability of the µ-needle MEAs in aqueous electrolyte is demonstrated and the devices are used to record extracellular signals from cardiomyocyte-like HL-1 cells. This proof-of-principle experiment shows the µ-needle MEAs’ cell-culture compatibility and functional integrity to investigate electrophysiological signals from living cells.