AAAshish A. Ankola

Ashish A. Ankola

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ashish A. Ankola has a total of 62 co-authors. Here are the top co-authors by number of shared publications:

  • Mariel E. Turner

    Division of Pediatric Cardiology, Morgan Stanley Children’s Hospital of New York Presbyterian, Columbia University Medical Center, New York, USA

    2 shared publications
  • Alejandro J. Torres

    Division of Pediatric Cardiology, Morgan Stanley Children’s Hospital of New York Presbyterian, Columbia University Medical Center, New York, USA

    1 shared publication
  • Amee Shah

    Division of Pediatric Cardiology, Morgan Stanley Children’s Hospital of New York Presbyterian, Columbia University Medical Center, New York, USA

    1 shared publication
  • Amir Navaei

    Department of Pathology & Immunology Baylor College of Medicine Houston Texas USA

    1 shared publication
  • Amy Hellinger

    Department of Cardiology Boston Children's Hospital Boston Massachusetts USA

    1 shared publication
  • Andrea Ontaneda

    Department of Critical Care, Texas Children’s Hospital, Houston, TX

    1 shared publication

Latest Publications

  • Use of Inhaled Tranexamic Acid for Pulmonary Hemorrhage in Pediatric Patients on Extracorporeal Membrane Oxygenation Support

    by Lynne Singleton, Curtis Kennedy, Blessy Philip, Amir Navaei, Saleh Bhar, Ashish Ankola, Katherine Doane, Andrea Ontaneda

    Bleeding is a common complication of extracorporeal membrane oxygenation (ECMO), is multifactorial, and results in significant morbidity and mortality. Pulmonary hemorrhage represents a serious adverse event in pediatric patients on ECMO and remains a challenging complication to manage. Its occurrence highlights the importance of identifying treatments that address bleeding complications in this population. This retrospective cohort study, from January 2018 to August 2022, explores the use of inhaled tranexamic acid (TXA), a clot-stabilizing agent, in 53 pediatric ECMO patients with new pulmonary hemorrhage. Primary diagnoses included respiratory failure (34%) and structural abnormalities (34%), such as congenital heart defects, congenital diaphragmatic hernia, and tracheal stenosis, with viral pneumonia being the leading cause of respiratory failure (47%). Results indicated that 48 of 53 (91%) patients showed cessation of pulmonary hemorrhage within 48 hours of inhaled TXA administration as measured by a decrease in our institution-specific bleeding scale from moderate to minor or no bleeding. In ECMO-managed pediatric patients with pulmonary hemorrhage, treatment with inhaled TXA demonstrated safety, with no observed adverse effects, and showed promising signs of contributing to the cessation of bleeding.


  • Steroid Utilization for Pediatric Ventricular Assist Device-Associated Inflammation and Association With Outcomes

    by Ashish A. Ankola, Hari P. Tunuguntla, Kyle D. Hope, Joseph A. Spinner, Swati Choudhry, Iki Adachi, Kriti Puri

    The impact of methylprednisolone (MP) on ventricular assist device (VAD)-associated inflammation in children and its association with outcomes remains unclear. We report this single-center retrospective study of children less than 21 years old supported with a VAD from February 2018 to December 2022. Methylprednisolone utilization, serial laboratory markers of hemolysis, inflammation, anticoagulation, and VAD adverse outcomes were analyzed. Sixty-eight patients (47% male, median age 3.2 years, 54% pulsatile flow) were included. Thirty-three patients (49%) received MP during VAD support, starting at a median 9 days post-implant (interquartile range [IQR]: 7–14), and for a median of 4 days (IQR: 3–5). Post-MP, there was a significant reduction in c-reactive protein (CRP) (12.4–3.2 mg/dl, p < 0.001) and fibrinogen (592–325 mg/dl, p < 0.001). Patients receiving MP had a higher daily rate of decline of fibrinogen (p = 0.024) and higher bivalirudin dose (p = 0.013) in the 2nd week post-implant. Methylprednisolone utilization was associated with higher proportion of stroke (p = 0.023), infection (p = 0.010), and pump thrombosis (p = 0.023). Methylprednisolone is used frequently during pediatric VAD support and reduces inflammatory markers. Infectious and thrombotic complications were more common in the cohort receiving MP, and larger studies are needed to investigate this further.

  • Retrospective Comparison of Recombinant Activated Factor VII Versus 4-Factor Prothrombin Complex Concentrate in Cardiac Surgical Patients

    by David Faraoni, Anna Guindi, Ashish A. Ankola, Ashraf Resheidat, Ziyad Binsalamah, Jun Teruya, Fabio Savorgnan, David F. Vener


  • Cost-effectiveness of bivalirudin in pediatric ventricular assist devices

    by Danielle Burstein, Stephen Kimmel, Mary Putt, Joseph Rossano, Christina VanderPluym, Ashish Ankola, Angela Lorts, Katsuhide Maeda, Matthew O'COnnor, Jonathan Edelson, et al.


  • Coagulation profiles and viscoelastic testing in multisystem inflammatory syndrome in children

    by Ashish A. Ankola, Victoria R. Bradford, Jane W. Newburger, Sirisha Emani, Audrey Dionne, Kevin Friedman, Mary Beth Son, Lauren A. Henderson, Pui Y. Lee, Amy Hellinger, et al.

    Objective: To characterize viscoelastic testing profiles of children with multisystem inflammatory syndrome in children (MIS‐C).Methods: This single‐center retrospective review included 30 patients diagnosed with MIS‐C from March 1 to September 1, 2020. Thromboelastography (TEG) with platelet mapping was performed in 19 (63%) patients and compared to age‐ and sex‐matched controls prior to cardiac surgery. Relationships between TEG parameters and inflammatory markers were assessed using correlation.Results: Patients with MIS‐C had abnormal TEG results compared to controls, including decreased kinetic (K) time (1.1 vs. 1.7 minutes, p < .01), increased alpha angle (75.0° vs. 65.7°, p < .01), increased maximum amplitude (70.8 vs. 58.3 mm, p < .01), and decreased lysis in 30 minutes (Ly30) (1.1% vs. 3.7%, p = .03); consistent with increased clot formation rate and strength, and reduced fibrinolysis. TEG maximum amplitude was moderately correlated with erythrocyte sedimentation rate (ESR) (r = 0.60, p = .02), initial platelet count (r = 0.67, p < .01), and peak platelet count (r = 0.51, p = .03). TEG alpha angle was moderately correlated with peak platelet count (r = 0.54, p = .02). Seventeen (57%) patients received aspirin (ASA) and anticoagulation, five (17%) received only ASA, and three (10%) received only anticoagulation. No patients had a symptomatic thrombotic event. Six (20%) patients had a bleeding event, none of which was major.Conclusions: Patients with MIS‐C had evidence of hypercoagulability on TEG. Increased ESR and platelets were associated with higher clot strength. Patients were prophylactically treated with ASA or anticoagulation with no symptomatic thrombosis or major bleeding. Further multicenter study is required to characterize the rate of thrombosis and optimal thromboprophylaxis algorithm in this patient population.


  • Early Thromboprophylaxis Initiation is Associated With Reduced Fontan Thromboses in the Early Postoperative Period

    by Ashish A. Ankola, Brett R. Anderson, Tarif A. Choudhury, Ellis Rochelson, Rozelle Corda, Emile A. Bacha, Arthur J. Smerling


  • Left Ventricular Strain Normalizes After Balloon Aortic Valvuloplasty in Infants with Congenital Aortic Stenosis

    by Ashish A. Ankola, Michael P. DiLorenzo, Mariel E. Turner, Alejandro J. Torres, Matthew A. Crystal, Amee Shah

    Severe aortic stenosis (AS) causes left ventricular (LV) afterload and subendocardial ischemia. Despite this, most infants with AS have normal LV ejection fraction (EF). Strain analysis using two-dimensional speckle tracking echocardiography (2DSTE) may identify more sensitive markers of systolic dysfunction. We sought to show changes in LV strain after balloon aortic valvuloplasty (BAV) in infants with AS. Twenty-seven infants ≤ 1 year of age with AS who underwent BAV from 2007 to 2017 were included. Echocardiograms before/after BAV were retrospectively analyzed with 2DSTE. Median age was 29 days (interquartile range 3–52) and LV EF was 64 ± 10%. Global longitudinal strain (GLS) significantly improved post-BAV (− 17 ± 5 vs. − 20 ± 4%, p = 0.001) with no difference in global circumferential strain. Peak longitudinal strain was abnormal at the inferoseptal base and mid-ventricle (− 15 ± 6 and − 17 ± 5 = 7%, respectively) and significantly improved in the basal and mid-anterolateral segments (− 17 ± 5 vs. − 21 ± 5%, p < 0.01; − 17 ± 6% vs. − 20 ± 5%, p = 0.01, respectively). Five (20%) patients underwent reintervention, and had significantly higher peak-to-peak pre and post-BAV AS gradients (86 ± 14 vs. 61 ± 20 mmHg, p = 0.02; 33 ± 17 vs. 21 ± 10 mmHg, p = 0.04, respectively). In conclusion, longitudinal strain is abnormal in infants with AS and improves to previously published normal values after BAV.


  • Biventricular Impella use in pediatric patients with severe graft dysfunction from acute rejection after heart transplantation

    by Ashish A. Ankola, Jennie McAllister, Mariel E. Turner, Warren A. Zuckerman, Marc E. Richmond, Linda J. Addonizio, Teresa M. Lee, Sabrina P. Law

    Introduction Rejection with severe hemodynamic compromise is a significant source of morbidity and mortality for pediatric heart transplant patients. Traditionally, treatment of these patients includes inotropes and escalation to extracorporeal membrane oxygenation (ECMO) when necessary. There is increasing interest in using percutaneous ventricular assistive devices in the pediatric population as a less invasive alternative to ECMO. We report the largest case series to date of biventricular support using percutaneous Impella devices. Methods Case series performed by retrospective chart review. Hemodynamics, left ventricular ejection fraction (LVEF), and indices of end organ function were collected before and after Impella placement. Results A 14‐year‐old male, 18‐year‐old male, and 19‐year‐old female, all status post‐ heart transplant, presented with severely decreased biventricular function due to presumed clinical rejection, requiring maximal inotropic support without improvement. In all 3 cases, simultaneous Impella CP and RP devices were placed percutaneously. Pre‐implantation, LVEF was 40%, 23% and 25%, respectively. Hemodynamics measured invasively prior to device placement showed elevated filling pressures. Adverse events while on support included bleeding, hemolysis, and right femoral arterial dissection during implantation. All patients were successfully weaned from the devices and survived to discharge. The average time of right‐sided support and total support was 11 days and 13 days, respectively. After device removal, right sided pressures and echocardiographic measurements showed improvement in all patients. Conclusion Bilateral Impella configuration (BiPella) is a viable option for temporary mechanical circulatory support in pediatric patients with significant graft dysfunction.