Ruiping Duan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ruiping Duan has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
Bo Du
The Key Laboratory of Biomedical Material of Tianjin, Biomedical Barriers Research Center, Chinese Academy of Medical Sciences & Peking Union Medical College Institute of Biomedical Engineering, Tianjin, 300192, PR, China
3 shared publications- Qiqing Zhang
Institute of Biomedical Engineering, The Second Clinical Medical College of Jinan University (Shenzhen People's Hospital), Shenzhen, 518020, Guangdong, PR China
2 shared publications - Xuemin Li
State Key Laboratory of Advanced Medical Materials and Devices, Key Laboratory of Biomedical Material of Tianjin, Biomedical Barriers Research Center, Chinese Academy of Medical Sciences & Peking Union Medical College Institute of Biomedical Engineering, Tianjin 300192, PR China
2 shared publications Yimeng Wang
The Key Laboratory of Biomedical Material of Tianjin, Biomedical Barriers Research Center, Chinese Academy of Medical Sciences & Peking Union Medical College Institute of Biomedical Engineering, Tianjin, 300192, PR, China
2 shared publicationsZiqiang Wang
The Key Laboratory of Biomedical Material of Tianjin, Biomedical Barriers Research Center, Chinese Academy of Medical Sciences & Peking Union Medical College Institute of Biomedical Engineering, Tianjin, 300192, PR, China
2 shared publicationsDanning Su
The Key Laboratory of Biomedical Material of Tianjin, Biomedical Barriers Research Center, Chinese Academy of Medical Sciences & Peking Union Medical College Institute of Biomedical Engineering, 236 Baidi Road, NanKai District, Tianjin 300192, P.R. China
1 shared publication
Latest Publications
- Open Access
Gelatin/Hyaluronic Acid Photocrosslinked Double Network Hydrogel with Nano-Hydroxyapatite Composite for Potential Application in Bone Repair
The application of hydrogels in bone repair is limited due to their low mechanical strength. Simulating bone extracellular matrix, methylacrylylated gelatin (GelMA)/methylacrylylated hyaluronic acid (HAMA)/nano-hydroxyapatite(nHap) composite hydrogels were prepared by combining the double network strategy and composite of nHap in this study. The precursor solutions of the composite hydrogels were injectable due to their shear thinning property. The compressive elastic modulus of the composite hydrogel was significantly enhanced, the fracture strength of the composite hydrogel nearly reached 1 MPa, and the composite hydrogel retained its high water content at above 88%. The composite hydrogels possess good compatibility with BMSCS and have the potential to be used as injectable hydrogels for bone defect treatment.
Open AccessGelatin/Hyaluronic Acid Photocrosslinked Double Network Hydrogel with Nano-Hydroxyapatite Composite for Potential Application in Bone Repair
The application of hydrogels in bone repair is limited due to their low mechanical strength. Simulating bone extracellular matrix, methylacrylylated gelatin (GelMA)/methylacrylylated hyaluronic acid (HAMA)/nano-hydroxyapatite(nHap) composite hydrogels were prepared by combining the double network strategy and composite of nHap in this study. The precursor solutions of the composite hydrogels were injectable due to their shear thinning property. The compressive elastic modulus of the composite hydrogel was significantly enhanced, the fracture strength of the composite hydrogel nearly reached 1 MPa, and the composite hydrogel retained its high water content at above 88%. The composite hydrogels possess good compatibility with BMSCS and have the potential to be used as injectable hydrogels for bone defect treatment.
- Open Access
- 8 July 2021
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 6 (28) , 18300-18313
Blending with Poly(l-lactic acid) Improves the Printability of Poly(l-lactide-co-caprolactone) and Enhances the Potential Application in Cartilage Tissue Engineering
Poly(l-lactide-co-caprolactone) (PLCL, 50:50) has been used in cartilage tissue engineering because of its high elasticity. However, its mechanical properties, including its rigidity and viscoelasticity, must be improved for compatibility with native cartilage. In this study, a set of PLCL/poly(l-lactic acid) (PLLA) blends was prepared by blending with different mass ratios of PLLA that range from 10 to 50%, using thermoplastic techniques. After testing the properties of these PLCL/PLLA blends, they were used to fabricate scaffolds by the 3D printing technology. The structures and viscoelastic behavior of the PLCL/PLLA scaffolds were determined, and then, the potential application of the scaffolds in cartilage tissue engineering was evaluated by chondrocytes culture. All blends demonstrate good thermal stability for the 3D printing technology. All blends show good toughness, while the rigidity of PLCL is increased through PLLA blending, and Young’s modulus of blends with 10–20% PLLA is similar to that of native cartilage. Furthermore, blending with PLLA improves the processability of PLCL for 3D printing, and the compression modulus and viscoelasticity of 3D-printed PLCL/PLLA scaffolds are different from that of PLCL. Additionally, the stress relaxation time (t1/2) of the PLCL/PLLA scaffolds, which is important for chondrogenesis, is dramatically shortened compared with the pure PLCL scaffold at the same 3D-printing filling rate. Consistently, the PLCL90PLLA10 scaffold at a 70% filling rate with much shorter t1/2 is more conducive to the proliferation and chondrogenesis of in vitro seeded chondrocytes accompanied by upregulated expression of SOX9 than the PLCL scaffold. Taken together, these results demonstrate that blending with PLLA improves the printability of PLCL and enhances its potential application, particularly PLCL/PLLA scaffolds with a low ratio of PLLA, in cartilage tissue engineering.
- 8 July 2021
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 6 (28) , 18300-18313
Open AccessBlending with Poly(l-lactic acid) Improves the Printability of Poly(l-lactide-co-caprolactone) and Enhances the Potential Application in Cartilage Tissue Engineering
Poly(l-lactide-co-caprolactone) (PLCL, 50:50) has been used in cartilage tissue engineering because of its high elasticity. However, its mechanical properties, including its rigidity and viscoelasticity, must be improved for compatibility with native cartilage. In this study, a set of PLCL/poly(l-lactic acid) (PLLA) blends was prepared by blending with different mass ratios of PLLA that range from 10 to 50%, using thermoplastic techniques. After testing the properties of these PLCL/PLLA blends, they were used to fabricate scaffolds by the 3D printing technology. The structures and viscoelastic behavior of the PLCL/PLLA scaffolds were determined, and then, the potential application of the scaffolds in cartilage tissue engineering was evaluated by chondrocytes culture. All blends demonstrate good thermal stability for the 3D printing technology. All blends show good toughness, while the rigidity of PLCL is increased through PLLA blending, and Young’s modulus of blends with 10–20% PLLA is similar to that of native cartilage. Furthermore, blending with PLLA improves the processability of PLCL for 3D printing, and the compression modulus and viscoelasticity of 3D-printed PLCL/PLLA scaffolds are different from that of PLCL. Additionally, the stress relaxation time (t1/2) of the PLCL/PLLA scaffolds, which is important for chondrogenesis, is dramatically shortened compared with the pure PLCL scaffold at the same 3D-printing filling rate. Consistently, the PLCL90PLLA10 scaffold at a 70% filling rate with much shorter t1/2 is more conducive to the proliferation and chondrogenesis of in vitro seeded chondrocytes accompanied by upregulated expression of SOX9 than the PLCL scaffold. Taken together, these results demonstrate that blending with PLLA improves the printability of PLCL and enhances its potential application, particularly PLCL/PLLA scaffolds with a low ratio of PLLA, in cartilage tissue engineering.
- 9 February 2018
- Published by American Chemical Society (ACS) in ACS Biomaterials Science & Engineering
- Vol. 4 (3) , 1055-1063
Chitosan-Stabilized Self-Assembled Fluorescent Gold Nanoclusters for Cell Imaging and Biodistribution in Vivo
Biocompatible, near-infrared luminescent gold nanoclusters were synthesized in situ using as-prepared chitosan grafted with N-Acetyl-L-cysteine (NAC-CS). The fluorescent gold nanoclusters coated with chitosan-N-acetyl-L-cysteine (AuNCs@NAC-CS) was aggregated by multiple ultrasmall gold nanoclusters closing with each other, with strong fluorescence emission at 680 nm upon excitation at 350 nm. AuNCs@NAC-CS did not display any appreciable cytotoxicity on cells even at a concentration of 1.2 mg mL-1. AuNCs@NAC-CS were more insensitive to H2O2 and trypsin compared with fluorescent gold nanoclusters coated with Albumin BovineⅤ(AuNCs@BSA), which make them have long time imaging in HeLa cells. Furthermore, the obvious fluorescence signal of AuNCs@NAC-CS appeared in the liver and kidney of the normal mice after 6 h injection. And the fluorescence intensity decreased after that because of the highly efficient clearance characteristics of ultrasmall nanoparticles. These findings demonstrated that AuNCs@NAC-CS possessed good fluorescence, low cytotoxicity, and low sensitivity to some content of cells, allowing imaging of the living cells.
- 9 February 2018
- Published by American Chemical Society (ACS) in ACS Biomaterials Science & Engineering
- Vol. 4 (3) , 1055-1063
Chitosan-Stabilized Self-Assembled Fluorescent Gold Nanoclusters for Cell Imaging and Biodistribution in Vivo
Biocompatible, near-infrared luminescent gold nanoclusters were synthesized in situ using as-prepared chitosan grafted with N-Acetyl-L-cysteine (NAC-CS). The fluorescent gold nanoclusters coated with chitosan-N-acetyl-L-cysteine (AuNCs@NAC-CS) was aggregated by multiple ultrasmall gold nanoclusters closing with each other, with strong fluorescence emission at 680 nm upon excitation at 350 nm. AuNCs@NAC-CS did not display any appreciable cytotoxicity on cells even at a concentration of 1.2 mg mL-1. AuNCs@NAC-CS were more insensitive to H2O2 and trypsin compared with fluorescent gold nanoclusters coated with Albumin BovineⅤ(AuNCs@BSA), which make them have long time imaging in HeLa cells. Furthermore, the obvious fluorescence signal of AuNCs@NAC-CS appeared in the liver and kidney of the normal mice after 6 h injection. And the fluorescence intensity decreased after that because of the highly efficient clearance characteristics of ultrasmall nanoparticles. These findings demonstrated that AuNCs@NAC-CS possessed good fluorescence, low cytotoxicity, and low sensitivity to some content of cells, allowing imaging of the living cells.