Li-Chen Su
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Li-Chen Su has a total of 55 co-authors. Here are the top co-authors by number of shared publications:
- Sheng-Fan Wang
Center for Tropical Medicine and Infectious Disease, Kaohsiung Medical University, Kaohsiung 80708, Taiwan
3 shared publications Ying-Feng Chang
Artificial Intelligence Research Center, Chang Gung University, Taoyuan, 333323, Taiwan; Department of Gastroenterology and Hepatology, New Taipei Municipal Tu Cheng Hospital (Built and Operated By Chang Gung Medical Foundation), New Taipei City, 236017, Taiwan
3 shared publicationsArunee Thitithanyanont
Department of Microbiology, Faculty of Science, Mahidol University, Bangkok 10400, Thailand
2 shared publications- Chien-Cheng Kuo
Department of Optics and Photonics, National Central University, 300, Zhongda Road, Zhongli District, Taoyuan City, 320317, Taiwan, R.O.C
2 shared publications Meng-Chi Li
General Education Center, Ming Chi University of Technology, New Taipei City, 243303, Taiwan; Organic Electronics Research Center, Ming Chi University of Technology, New Taipei City, 243303, Taiwan
2 shared publications- Meng-Chi Li
Optical Sciences Center/Thin Film Technology Center, National Central University, 300, Chung Da Rd., Chung Li, Taoyuan 32001, Taiwan
2 shared publications
Latest Publications
- 17 January 2025
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1341, 343640
AI integration into wavelength-based SPR biosensing: Advancements in spectroscopic analysis and detection
- 17 January 2025
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1341, 343640
AI integration into wavelength-based SPR biosensing: Advancements in spectroscopic analysis and detection
- Open Access
- 28 December 2024
- Published by MDPI AG in Technologies
- Vol. 13 (1) , 11
Inhibition of Anti-Reflection Film Cracks on Plastic Substrates Using Nanolaminate Layer Deposition in Plasma-Enhanced Atomic Layer Deposition
In this research, we mainly increase the adhesion of PMMA substrate and film, which is reflected in the environmental test. This study used plasma-enhanced atomic layer deposition (PEALD) to find the relationship between the intensity of XRD reflection peak and the root-mean-square surface roughness (σRMS) of hafnium dioxide (HfO2) at different thicknesses by reducing the plasma power at different process temperatures. In this experiment, HfO2 was found to have the highest intensity of XRD at its maximum thickness. According to the different intensities of XRD of HfO2 at different thicknesses, aluminum oxide (Al2O3) was inserted as crystallization cutoff layers, and the two materials were combined into nanolaminates. The corresponding σRMS value also changed from 1.25 to 0.434 nm after treatment under the fourth experimental design. This study improved this mismatch between interfaces by adjusting the yield strength and ductility using Al2O3 layers and by creating an inhibition layer. In addition, through the processing of inserted Al2O3 layers, the degree of crystallization was changed so that the material and substrate could maintain their normal surfaces without cracking after the environmental tests. After inserting five 1 nm thick Al2O3 layers, the environmental test results were improved. The test time was increased from the original 56 h to 352 h.
- 28 December 2024
- Published by MDPI AG in Technologies
- Vol. 13 (1) , 11
Open AccessInhibition of Anti-Reflection Film Cracks on Plastic Substrates Using Nanolaminate Layer Deposition in Plasma-Enhanced Atomic Layer Deposition
In this research, we mainly increase the adhesion of PMMA substrate and film, which is reflected in the environmental test. This study used plasma-enhanced atomic layer deposition (PEALD) to find the relationship between the intensity of XRD reflection peak and the root-mean-square surface roughness (σRMS) of hafnium dioxide (HfO2) at different thicknesses by reducing the plasma power at different process temperatures. In this experiment, HfO2 was found to have the highest intensity of XRD at its maximum thickness. According to the different intensities of XRD of HfO2 at different thicknesses, aluminum oxide (Al2O3) was inserted as crystallization cutoff layers, and the two materials were combined into nanolaminates. The corresponding σRMS value also changed from 1.25 to 0.434 nm after treatment under the fourth experimental design. This study improved this mismatch between interfaces by adjusting the yield strength and ductility using Al2O3 layers and by creating an inhibition layer. In addition, through the processing of inserted Al2O3 layers, the degree of crystallization was changed so that the material and substrate could maintain their normal surfaces without cracking after the environmental tests. After inserting five 1 nm thick Al2O3 layers, the environmental test results were improved. The test time was increased from the original 56 h to 352 h.
- 27 April 2023
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 95 (18) , 7186-7194
Facile and Unplugged Surface Plasmon Resonance Biosensor with NIR-Emitting Perovskite Nanocomposites for Fast Detection of SARS-CoV-2
The emergence of the coronavirus disease 2019 (COVID-19) pandemic prompted researchers to develop portable biosensing platforms, anticipating to detect the analyte in a label-free, direct, and simple manner, for deploying on site to prevent the spread of the infectious disease. Herein, we developed a facile wavelength-based SPR sensor built with the aid of a 3D printing technology and synthesized air-stable NIR-emitting perovskite nanocomposites as the light source. The simple synthesis processes for the perovskite quantum dots enabled low-cost and large-area production and good emission stability. The integration of the two technologies enabled the proposed SPR sensor to exhibit the characteristics of lightweight, compactness, and being without a plug, just fitting the requirements of on-site detection. Experimentally, the detection limit of the proposed NIR SPR biosensor for refractive index change reached the 10-6 RIU level, comparable with that of state-of-the-art portable SPR sensors. In addition, the bio-applicability of the platform was validated by incorporating a homemade high-affinity polyclonal antibody toward the SARS-CoV-2 spike protein. The results demonstrated that the proposed system was capable of discriminating between clinical swab samples collected from COVID-19 patients and healthy subjects because the used polyclonal antibody exhibited high specificity against SARS-CoV-2. Most importantly, the whole measurement process not only took less than 15 min but also needed no complex procedures or multiple reagents. We believe that the findings disclosed in this work can open an avenue in the field of on-site detection for highly pathogenic viruses.
- 27 April 2023
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 95 (18) , 7186-7194
Facile and Unplugged Surface Plasmon Resonance Biosensor with NIR-Emitting Perovskite Nanocomposites for Fast Detection of SARS-CoV-2
The emergence of the coronavirus disease 2019 (COVID-19) pandemic prompted researchers to develop portable biosensing platforms, anticipating to detect the analyte in a label-free, direct, and simple manner, for deploying on site to prevent the spread of the infectious disease. Herein, we developed a facile wavelength-based SPR sensor built with the aid of a 3D printing technology and synthesized air-stable NIR-emitting perovskite nanocomposites as the light source. The simple synthesis processes for the perovskite quantum dots enabled low-cost and large-area production and good emission stability. The integration of the two technologies enabled the proposed SPR sensor to exhibit the characteristics of lightweight, compactness, and being without a plug, just fitting the requirements of on-site detection. Experimentally, the detection limit of the proposed NIR SPR biosensor for refractive index change reached the 10-6 RIU level, comparable with that of state-of-the-art portable SPR sensors. In addition, the bio-applicability of the platform was validated by incorporating a homemade high-affinity polyclonal antibody toward the SARS-CoV-2 spike protein. The results demonstrated that the proposed system was capable of discriminating between clinical swab samples collected from COVID-19 patients and healthy subjects because the used polyclonal antibody exhibited high specificity against SARS-CoV-2. Most importantly, the whole measurement process not only took less than 15 min but also needed no complex procedures or multiple reagents. We believe that the findings disclosed in this work can open an avenue in the field of on-site detection for highly pathogenic viruses.
- Open Access
- 16 September 2022
- Published by Wiley in Bioengineering & Translational Medicine
- Vol. 8 (5) , e10410
Boosting the detection performance of severe acute respiratory syndrome coronavirus 2 test through a sensitive optical biosensor with new superior antibody
The severe acute respiratory syndrome coronavirus 2 (SARS‐CoV‐2) virus emerged in late 2019 leading to the COVID‐19 disease pandemic that triggered socioeconomic turmoil worldwide. A precise, prompt, and affordable diagnostic assay is essential for the detection of SARS‐CoV‐2 as well as its variants. Antibody against SARS‐CoV‐2 spike (S) protein was reported as a suitable strategy for therapy and diagnosis of COVID‐19. We, therefore, developed a quick and precise phase‐sensitive surface plasmon resonance (PS‐SPR) biosensor integrated with a novel generated anti‐S monoclonal antibody (S‐mAb). Our results indicated that the newly generated S‐mAb could detect the original SARS‐CoV‐2 strain along with its variants. In addition, a SARS‐CoV‐2 pseudovirus, which could be processed in BSL‐2 facility was generated for evaluation of sensitivity and specificity of the assays including PS‐SPR, homemade target‐captured ELISA, spike rapid antigen test (SRAT), and quantitative reverse transcription polymerase chain reaction (qRT‐PCR). Experimentally, PS‐SPR exerted high sensitivity to detect SARS‐CoV‐2 pseudovirus at 589 copies/ml, with 7‐fold and 70‐fold increase in sensitivity when compared with the two conventional immunoassays, including homemade target‐captured ELISA (4 × 103 copies/ml) and SRAT (4 × 104 copies/ml), using the identical antibody. Moreover, the PS‐SPR was applied in the measurement of mimic clinical samples containing the SARS‐CoV‐2 pseudovirus mixed with nasal mucosa. The detection limit of PS‐SPR is calculated to be 1725 copies/ml, which has higher accuracy than homemade target‐captured ELISA (4 × 104 copies/ml) and SRAT (4 × 105 copies/ml) and is comparable with qRT‐PCR (1250 copies/ml). Finally, the ability of PS‐SPR to detect SARS‐CoV‐2 in real clinical specimens was further demonstrated, and the assay time was less than 10 min. Taken together, our results indicate that this novel S‐mAb integrated into PS‐SPR biosensor demonstrates high sensitivity and is time‐saving in SARS‐CoV‐2 virus detection. This study suggests that incorporation of a high specific recognizer in SPR biosensor is an alternative strategy that could be applied in developing other emerging or re‐emerging pathogenic detection platforms.
- 16 September 2022
- Published by Wiley in Bioengineering & Translational Medicine
- Vol. 8 (5) , e10410
Open AccessBoosting the detection performance of severe acute respiratory syndrome coronavirus 2 test through a sensitive optical biosensor with new superior antibody
The severe acute respiratory syndrome coronavirus 2 (SARS‐CoV‐2) virus emerged in late 2019 leading to the COVID‐19 disease pandemic that triggered socioeconomic turmoil worldwide. A precise, prompt, and affordable diagnostic assay is essential for the detection of SARS‐CoV‐2 as well as its variants. Antibody against SARS‐CoV‐2 spike (S) protein was reported as a suitable strategy for therapy and diagnosis of COVID‐19. We, therefore, developed a quick and precise phase‐sensitive surface plasmon resonance (PS‐SPR) biosensor integrated with a novel generated anti‐S monoclonal antibody (S‐mAb). Our results indicated that the newly generated S‐mAb could detect the original SARS‐CoV‐2 strain along with its variants. In addition, a SARS‐CoV‐2 pseudovirus, which could be processed in BSL‐2 facility was generated for evaluation of sensitivity and specificity of the assays including PS‐SPR, homemade target‐captured ELISA, spike rapid antigen test (SRAT), and quantitative reverse transcription polymerase chain reaction (qRT‐PCR). Experimentally, PS‐SPR exerted high sensitivity to detect SARS‐CoV‐2 pseudovirus at 589 copies/ml, with 7‐fold and 70‐fold increase in sensitivity when compared with the two conventional immunoassays, including homemade target‐captured ELISA (4 × 103 copies/ml) and SRAT (4 × 104 copies/ml), using the identical antibody. Moreover, the PS‐SPR was applied in the measurement of mimic clinical samples containing the SARS‐CoV‐2 pseudovirus mixed with nasal mucosa. The detection limit of PS‐SPR is calculated to be 1725 copies/ml, which has higher accuracy than homemade target‐captured ELISA (4 × 104 copies/ml) and SRAT (4 × 105 copies/ml) and is comparable with qRT‐PCR (1250 copies/ml). Finally, the ability of PS‐SPR to detect SARS‐CoV‐2 in real clinical specimens was further demonstrated, and the assay time was less than 10 min. Taken together, our results indicate that this novel S‐mAb integrated into PS‐SPR biosensor demonstrates high sensitivity and is time‐saving in SARS‐CoV‐2 virus detection. This study suggests that incorporation of a high specific recognizer in SPR biosensor is an alternative strategy that could be applied in developing other emerging or re‐emerging pathogenic detection platforms.
- Open Access
A Simple Phase-Sensitive Surface Plasmon Resonance Sensor Based on Simultaneous Polarization Measurement Strategy
The SPR phenomenon results in an abrupt change in the optical phase such that one can measure the phase shift of the reflected light as a sensing parameter. Moreover, many studies have demonstrated that the phase changes more acutely than the intensity, leading to a higher sensitivity to the refractive index change. However, currently, the optical phase cannot be measured directly because of its high frequency; therefore, investigators usually have to use complicated techniques for the extraction of phase information. In this study, we propose a simple and effective strategy for measuring the SPR phase shift based on phase-shift interferometry. In this system, the polarization-dependent interference signals are recorded simultaneously by a pixelated polarization camera in a single snapshot. Subsequently, the phase information can be effortlessly acquired by a phase extraction algorithm. Experimentally, the proposed phase-sensitive SPR sensor was successfully applied for the detection of small molecules of glyphosate, which is the most frequently used herbicide worldwide. Additionally, the sensor exhibited a detection limit of 15 ng/mL (0.015 ppm). Regarding its simplicity and effectiveness, we believe that our phase-sensitive SPR system presents a prospective method for acquiring phase signals.
Open AccessA Simple Phase-Sensitive Surface Plasmon Resonance Sensor Based on Simultaneous Polarization Measurement Strategy
The SPR phenomenon results in an abrupt change in the optical phase such that one can measure the phase shift of the reflected light as a sensing parameter. Moreover, many studies have demonstrated that the phase changes more acutely than the intensity, leading to a higher sensitivity to the refractive index change. However, currently, the optical phase cannot be measured directly because of its high frequency; therefore, investigators usually have to use complicated techniques for the extraction of phase information. In this study, we propose a simple and effective strategy for measuring the SPR phase shift based on phase-shift interferometry. In this system, the polarization-dependent interference signals are recorded simultaneously by a pixelated polarization camera in a single snapshot. Subsequently, the phase information can be effortlessly acquired by a phase extraction algorithm. Experimentally, the proposed phase-sensitive SPR sensor was successfully applied for the detection of small molecules of glyphosate, which is the most frequently used herbicide worldwide. Additionally, the sensor exhibited a detection limit of 15 ng/mL (0.015 ppm). Regarding its simplicity and effectiveness, we believe that our phase-sensitive SPR system presents a prospective method for acquiring phase signals.
- 23 May 2021
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 93 (22) , 8002-8009
Amplification-free Detection of Cytomegalovirus miRNA Using a Modification-free Surface Plasmon Resonance Biosensor
Cytomegalovirus (CMV) is the most frequent cause of congenital infection worldwide; congenital CMV may lead to significant mortality, morbidity, or long-term sequelae, such as sensorineural hearing loss. The current study presents a newly designed surface plasmon resonance (SPR) biosensor for CMV-specific microRNAs that does not involve extra care for receptor immobilization or treatment to prevent fouling on bare gold surfaces. The modification-free approach, which utilizes a poly-adenine [poly(A)]–Au interaction, exhibited a high affinity that was comparable to that of the gold–sulfur (Au–S) interaction. In addition, magnetic nanoparticles (MNPs) were used to separate the analyte from complex sample matrixes that significantly reduced nonspecific adsorption. Moreover, the MNPs also played an important role in SPR signal amplification due to the binding-induced change in the refractive index. Our SPR biosensing platform was used successfully for the multi-detection of the microRNAs, UL22A-5p, and UL112-3p, which were associated with CMV. Our SPR biosensor offered the detection limits of 108 fM and 24 fM for UL22A-5p and UL112-3p, respectively, with an R2 of 0.9661 and 0.9985, respectively. The precision of this biosensor has an acceptable CV (coefficient of variation) value of <10%. In addition, our sensor is capable of discriminating between serum samples collected from healthy and CMV-infected newborns. Taken together, we believe that our newly developed SPR biosensing platform is a promising alternative for the diagnosis of CMV-specific microRNA in clinical settings, and its application for the detection of other miRNAs may be extended further.
- 23 May 2021
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 93 (22) , 8002-8009
Amplification-free Detection of Cytomegalovirus miRNA Using a Modification-free Surface Plasmon Resonance Biosensor
Cytomegalovirus (CMV) is the most frequent cause of congenital infection worldwide; congenital CMV may lead to significant mortality, morbidity, or long-term sequelae, such as sensorineural hearing loss. The current study presents a newly designed surface plasmon resonance (SPR) biosensor for CMV-specific microRNAs that does not involve extra care for receptor immobilization or treatment to prevent fouling on bare gold surfaces. The modification-free approach, which utilizes a poly-adenine [poly(A)]–Au interaction, exhibited a high affinity that was comparable to that of the gold–sulfur (Au–S) interaction. In addition, magnetic nanoparticles (MNPs) were used to separate the analyte from complex sample matrixes that significantly reduced nonspecific adsorption. Moreover, the MNPs also played an important role in SPR signal amplification due to the binding-induced change in the refractive index. Our SPR biosensing platform was used successfully for the multi-detection of the microRNAs, UL22A-5p, and UL112-3p, which were associated with CMV. Our SPR biosensor offered the detection limits of 108 fM and 24 fM for UL22A-5p and UL112-3p, respectively, with an R2 of 0.9661 and 0.9985, respectively. The precision of this biosensor has an acceptable CV (coefficient of variation) value of <10%. In addition, our sensor is capable of discriminating between serum samples collected from healthy and CMV-infected newborns. Taken together, we believe that our newly developed SPR biosensing platform is a promising alternative for the diagnosis of CMV-specific microRNA in clinical settings, and its application for the detection of other miRNAs may be extended further.
- 25 January 2018
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 90 (3) , 1861-1869
Simple Strategy for Rapid and Sensitive Detection of Avian Influenza A H7N9 Virus Based on Intensity-Modulated SPR Biosensor and New Generated Antibody
A new reassortant avian influenza A H7N9 virus have emerged in China since 2013, causing human infection with high mortality. An accurate and timely diagnosis is crucial for controlling the outbreaks of the disease. We therefore propose a simple strategy for rapidly and sensitively detecting the H7N9 virus using an intensity-modulated surface plasmon resonance (IM-SPR) biosensor integrated with a new generated monoclonal antibody. The novel antibody exhibits significant specificity to recognize H7N9 virus compared with other clinical human influenza isolates (p<0.01). Experimentally, the detection limit of the proposed approach for H7N9 virus detection is estimated to be 144 copies/mL, which is a 20-fold increase in sensitivity compared with homemade target-captured ELISA using the identical antibody. For the measurement of mimic clinical specimens containing the H7N9 virus mixed with nasal mucosa from flu-like syndrome patients, the detection limit is calculated to be 402 copies/mL, which is better than conventional influenza detection assays, quantitative reverse transcription polymerase chain reaction (qRT-PCR) and rapid influenza diagnostic test (RIDT). Most importantly, the assay time took less than 10 minutes. Combined, the results of this study indicate that the proposed simple strategy demonstrates high sensitivity and being time-saving for the H7N9 virus detection. By incorporating a high specific recognizer, the proposed technique has the potential to be used in applications and development of other emerging or re-emerging microbe detection platforms.
- 25 January 2018
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 90 (3) , 1861-1869
Simple Strategy for Rapid and Sensitive Detection of Avian Influenza A H7N9 Virus Based on Intensity-Modulated SPR Biosensor and New Generated Antibody
A new reassortant avian influenza A H7N9 virus have emerged in China since 2013, causing human infection with high mortality. An accurate and timely diagnosis is crucial for controlling the outbreaks of the disease. We therefore propose a simple strategy for rapidly and sensitively detecting the H7N9 virus using an intensity-modulated surface plasmon resonance (IM-SPR) biosensor integrated with a new generated monoclonal antibody. The novel antibody exhibits significant specificity to recognize H7N9 virus compared with other clinical human influenza isolates (p<0.01). Experimentally, the detection limit of the proposed approach for H7N9 virus detection is estimated to be 144 copies/mL, which is a 20-fold increase in sensitivity compared with homemade target-captured ELISA using the identical antibody. For the measurement of mimic clinical specimens containing the H7N9 virus mixed with nasal mucosa from flu-like syndrome patients, the detection limit is calculated to be 402 copies/mL, which is better than conventional influenza detection assays, quantitative reverse transcription polymerase chain reaction (qRT-PCR) and rapid influenza diagnostic test (RIDT). Most importantly, the assay time took less than 10 minutes. Combined, the results of this study indicate that the proposed simple strategy demonstrates high sensitivity and being time-saving for the H7N9 virus detection. By incorporating a high specific recognizer, the proposed technique has the potential to be used in applications and development of other emerging or re-emerging microbe detection platforms.