Jean Carlos Arouche Freire
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jean Carlos Arouche Freire has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Adriana Rosa Garcez Castro
Institute of Technology, Federal University of Pará, Belém, Brazil
1 shared publication Augusto Cesar F. Saraiva
Centro de Tecnologia da Eletronorte
1 shared publicationBianchi Serique Meiguins
Faculty of Computer, Federal University of Pará, Belém, Brazil
1 shared publicationJefferson Magalhaes De Morais
Faculty of Computer, Federal University of Pará, Belém, Brazil
1 shared publication- Jefferson Morais
Federal University of Para
1 shared publication Marcia Salomao Homci
Faculty of Computer, Federal University of Pará, Belém, Brazil
1 shared publication
Latest Publications
- Open Access
- 13 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 113499-113510
Transmission Line Fault Classification Using Hidden Markov Models
The maintenance of power quality in electrical power systems depends on addressing the major disturbances that may arise during generation, transmission and distribution. Many studies aim to investigate these disturbances by analyzing the behavior of the electrical signal through the classification of short circuit faults in power transmission lines as a way to assist the administration and maintenance of the electrical system. However, most fault classification methods generate a high computational cost that do not always yield satisfactory results; these methods utilize front ends in data processing before being processed by conventional classification algorithms such as Artificial Neural Network (ANN), Support Vector Machine (SVM), K-Nearest Neighbors (KNN), and Random Forest (RF) that are adopted into the Frame Based Sequence Classification (FBSC) architecture that uses the front ends Waveletenergy, Waveletconcat, RAW, Root Mean Square front ends (RMS) and ConcatFrontEnd. An alternative method for classifying faults without having to use front ends employs the UFPAFaults database and the Hidden Markov Model (HMM) algorithm that directly treats the electrical signal in the form of multivariate time series. The results indicate the HMM algorithm as a potential classifier because its comparatively low error rate of 0.03% exceeds the performance of the conventional classifiers ANN, SVM, KNN and RF as used with the FBSC architecture. When the statistical test with a significance of $\alpha =5$ % is applied, only the ANN and RF classifiers present a result close to what the HMM algorithm provides. Another relevant factor is that the HMM algorithm considerably decreases the computational cost by more than 90% of processing time as compared to the conventional classifiers of the FBSC architecture, thereby validating its potential in the direct classification of faults in electric power system transmission lines.
- 13 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 113499-113510
Open AccessTransmission Line Fault Classification Using Hidden Markov Models
The maintenance of power quality in electrical power systems depends on addressing the major disturbances that may arise during generation, transmission and distribution. Many studies aim to investigate these disturbances by analyzing the behavior of the electrical signal through the classification of short circuit faults in power transmission lines as a way to assist the administration and maintenance of the electrical system. However, most fault classification methods generate a high computational cost that do not always yield satisfactory results; these methods utilize front ends in data processing before being processed by conventional classification algorithms such as Artificial Neural Network (ANN), Support Vector Machine (SVM), K-Nearest Neighbors (KNN), and Random Forest (RF) that are adopted into the Frame Based Sequence Classification (FBSC) architecture that uses the front ends Waveletenergy, Waveletconcat, RAW, Root Mean Square front ends (RMS) and ConcatFrontEnd. An alternative method for classifying faults without having to use front ends employs the UFPAFaults database and the Hidden Markov Model (HMM) algorithm that directly treats the electrical signal in the form of multivariate time series. The results indicate the HMM algorithm as a potential classifier because its comparatively low error rate of 0.03% exceeds the performance of the conventional classifiers ANN, SVM, KNN and RF as used with the FBSC architecture. When the statistical test with a significance of $\alpha =5$ % is applied, only the ANN and RF classifiers present a result close to what the HMM algorithm provides. Another relevant factor is that the HMM algorithm considerably decreases the computational cost by more than 90% of processing time as compared to the conventional classifiers of the FBSC architecture, thereby validating its potential in the direct classification of faults in electric power system transmission lines.
- 8 February 2017
- Published by Springer Nature in Bulletin of Environmental Contamination and Toxicology
- Vol. 98 (5) , 677-681
Influence of the Amazon Hydrological Regime on Eutrophication Indicators of a Hydroelectric Power Plant Reservoir
Dam constructions in the Amazon have increased exponentially in the last decades, causing several environmental impacts and serious anthropogenic impacts in certain hydroelectric power plant reservoirs in the region have been identified. The assessment of the trophic status of these reservoirs is of interest to indicate man-made changes in the environment, but must take into account the hydrological cycle of the area. This can be relevant for environmental management actions, aiding in the identification of the ecological status of water bodies. In this context, physico-chemical parameters and eutrophication indicators were determined in a hydroelectric power plant reservoir in the Brazilian Amazon to assess trophic variations during the regional hydrological regime phases on the reservoir, namely dry, filling, full and emptying stages. The local hydrological regimes were shown to significantly influence TSS and turbidity, as well as NH4, NO3, PO4, with higher values consistently observed during the filling stage of the reservoir. In addition, differences among the sampling stations regarding land use, population and anthropogenic activities were reflected in the PO43− values during the different hydrological phases.
- 8 February 2017
- Published by Springer Nature in Bulletin of Environmental Contamination and Toxicology
- Vol. 98 (5) , 677-681
Influence of the Amazon Hydrological Regime on Eutrophication Indicators of a Hydroelectric Power Plant Reservoir
Dam constructions in the Amazon have increased exponentially in the last decades, causing several environmental impacts and serious anthropogenic impacts in certain hydroelectric power plant reservoirs in the region have been identified. The assessment of the trophic status of these reservoirs is of interest to indicate man-made changes in the environment, but must take into account the hydrological cycle of the area. This can be relevant for environmental management actions, aiding in the identification of the ecological status of water bodies. In this context, physico-chemical parameters and eutrophication indicators were determined in a hydroelectric power plant reservoir in the Brazilian Amazon to assess trophic variations during the regional hydrological regime phases on the reservoir, namely dry, filling, full and emptying stages. The local hydrological regimes were shown to significantly influence TSS and turbidity, as well as NH4, NO3, PO4, with higher values consistently observed during the filling stage of the reservoir. In addition, differences among the sampling stations regarding land use, population and anthropogenic activities were reflected in the PO43− values during the different hydrological phases.