LLLongjie Li

Longjie Li

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Longjie Li has a total of 38 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Mechanisms for insulation recovery during repetitive breakdowns in gas gaps

    by Longjie Li, Jiaxin Chen, Chen Yi, Xianfeng Xu, Guimin Xu, Biao Wang

    The insulation recovery during repetitive breakdowns in gas gaps is a fundamental scientific issue in both traditional and emerging electrical technology fields, which has received extensive attention over the years. This paper provides a systematic review of research methods for insulation recovery in repetitive breakdowns of gas gaps, progress made in understanding the thermal–hydrodynamic processes involved in this recovery (dissipation of deposited energy and restoration of neutral gas density), as well as the memory effect resulting from repetitive discharges and breakdowns (dominant factors and their underlying mechanisms). Based on current results, it is proposed that the insulation recovery of repetitive gas gaps breakdowns results from the synergistic effect between post-breakdown thermal-hydrodynamic processes and memory effects. This review aims to clarify the boundary and interplay between hydrodynamic processes and memory effects, as well as reveal their coupling relationship and synergistic mechanism. It also seeks to overcome barriers between related research fields, ultimately facilitating a resolution to the issue.


  • Open Access

    An Online Residual Learning Method for Hyperpsepctral Image Resolution Enhancement

    by Chen Yi, Chengyong Wang, Longjie Li, Zhuoxin Liu, Weihua Liu, Yuquan Gan

    HSI fusion approaches aims to recover high spatial resolution hyperspectral image (HSI) with the preservation of original spectral information. The existed fusion framework are designed to establish a spatial feature mapping relationship between low/high resolution HSIs, which is always an under-determined problem affected by artifacts and distortions. In this paper, a multi-layer residual learning fusion approach is proposed for HSI resolution enhancement. It is believed that there are residuals between recovered result and ideal ground truth HSI. Our method focuses on reducing the residuals to gradually modify the recovered HSI and iteratively make it approximate to the ground truth. Firstly, the back propagation neural network (BPNN) is employed to acquire an intermediate recovered result. Then, a series of online residual dictionaries are trained from residuals to update modified recovered HSIs in successive iterations. Therefore, the accurate recovered high resolution HSI less errors and spectral distortions.can be achieved. Experimental results on two different HSI datasets show that the proposed method can acquire better or comparable evaluation metric and visual fusion result with the current state-of-the-art methods.

  • Inactivation Mechanisms of Pulsed Corona Discharge Plasma on Escherichia Coli and Staphylococcus Aureus Phages

    by Gui-Min Xu, Cai-Qin Ma, Yu-Hang Song, Xi-Ying Wang, Jin-Ren Liu, Xiang-Ni Wang, Yi-Xin Cui, Jia-Jia Lu, Chu-Chu Kang, Long-Jie Li, et al.

    Pathogenic virus brings tremendous threat to human lives, livelihoods, and public health. The nonthermal plasma (NTP) generated through pulsed corona discharge has aroused considerable interest in microbial inactivation. However, the mechanism of virus inactivation by NTP is not fully understood. This study presented the NTP by means of corona discharge in air with the multineedles plate electrode driven by a pulsed power, and the electrical and optical characteristics of corona discharge plasma were analyzed. The Escherichia coli phage (ECP) vB-EcoP-Bp4 and Staphylococcus aureus phage (SAP) vB-StaM-JTB were utilized to explore plasma inactivation effect and mechanism. The killing log value (KLV) results indicated that corona discharge plasma could inactivate the two kinds of bacteriophages effectively. DNA and protein analysis revealed that the NTP damaged both nucleic acids and proteins, consistent with the morphological observation. From the variation of H $_{2}$ O $_{2}$ and NO $_{2}^{-}$ inside solution and its pH, it could be concluded that these strong oxidation reactive oxygen species (ROS) and reactive nitrogen species (RNS) induced by NTP would degrade the nucleic acid and protein, weakening bacteriophages replication ability and affecting the adsorption process of bacteriophages to infect the host bacteria.


  • Open Access

    The Influence of Electric Field Inhomogeneity on Repetitive Performance of a Corona-Stabilized Switch

    by Longjie Li, Zongze Huang, Yan Yang

    The corona-stabilized switch has a great potential in pulsed power systems where high pulse repetition frequencies are required. Corona discharge in SF 6 in highly inhomogeneous electric field is utilized to improve repetitive performance of this kind of switch. To clarify how the repetitive performance (insulation recovery and repetitive breakdown stability) of the switch depends on the field inhomogeneity, the insulation recovery and repetitive breakdown stability of a corona-stabilized switch are experimentally investigated and theoretically analyzed. An innovative double-pulse method combining breakdown voltage and discharge channel images is used to measure the insulation recovery of the switch. For different electrodes, their voltage jitters at pulse repetition frequencies of 1–2000 Hz are measured to illustrate the stability of repetitive breakdown. The experimental results are theoretically analyzed from the memory effect and behavior characteristics of the residual plasma, the critical volume and its dynamic characteristics. The results reveal the corona stabilization enhancement effect during the repetitive breakdown in SF 6 in extremely inhomogeneous field. The influence of electrode profile on the propagation of discharge channel shock wave, the decay of residual plasma and the recovery of neutral gas density are clarified. Effect of the electrostatic conditions, including the critical volume and its dynamic characteristics, and the intensity of corona discharge, on the repetitive performance of the switch are also clarified.


  • Effect of gas type on insulation recovery performance and repetitive breakdown stability of a corona-stabilized plasma closing switch

    by Longjie Li, Zongze Huang, Jiangtao Li

    The corona-stabilized plasma closing switch, which utilizes the stabilization effect resulted from the movement and accumulation of corona-generated space charge to improve the repetitive performance, has a great potential in repetitive pulsed power systems. In this paper, the influence of gas type on the recovery performance and repetitive breakdown stability of a corona-stabilized plasma closing switch is investigated. The results are analyzed from the memory effect of residual plasma, the development and propagation characteristics of streamer corona, and the thermo-hydrodynamic process of discharge channel. The enhancement effect of residual plasma on corona stabilization of the subsequent breakdown in the repetitive operation of the gas gap with highly inhomogeneous electric field and strong electronegative gas is proposed. The development and propagation characteristics of streamer corona in different gases that can lead to significant differences in the corona stabilization effect of breakdown are clarified. It is also found that the gas with small molecular mass and higher gas velocity exhibits excellent insulation recovery in the gas switch with uniform fields, but displays poor repetitive performance in the corona-stabilized switch with a rod-plate electrode.


  • Effect of switch parameters and polarity on the repetitive performance of a corona-stabilized switch viewed from behavior of space charge

    by Longjie Li, Jiangtao Li, Zheng Zhao

    The corona stabilization effect is produced by the motion and accumulation of space charges generated by localized ionization in a highly inhomogeneous electric field. This stabilization effect can be adopted to improve the repetitive performance of gas-discharge plasma closing switches. The behavior of space charge that produces the corona stabilization effect is different under different polarities of the applied voltage, and so the mechanisms of the corona stabilization effect for different polarities are also different. In this study, the effect of switch parameters (including electric field inhomogeneity, gas type, and operating pressure) on the behavior of the residual space charge generated by preceding breakdown and the effect of residual space charge behavior on the subsequent corona-stabilized breakdown under different polarities were investigated and analyzed. The results show that the corona-stabilized switch with high field inhomogeneity, gaseous medium containing SF6, and high operating pressure exhibits an excellent repetitive performance. For a corona-stabilized switch operating under the parameters mentioned above, the recovery performance under positive polarity is better than that under negative polarity when the recovery time is short.


  • Open Access

    Effect of pressure on repetitive performance of a corona-stabilized plasma closing switch

    by Longjie Li, Jiangtao Li, Zheng Zhao, Chenjie Li

    This paper reports on research to determine the effect of gas pressure on the repetitive performance of a corona-stabilized plasma closing switch. The influence of gas pressure on the withstand voltage recovery and the after-spark channel decay of a corona-stabilized switch is experimentally and theoretically investigated. The voltage recovery degree vs time curves and the development of discharge plasma channel after breakdown under various pressures were measured to indicate the repetitive performance of switch. A theoretical analysis based on propagation characteristics of corona discharge critical volume is applied to explain the experimental results. The critical breakdown electric field strength and corona critical volume under different pressures were calculated and their effect on the re-breakdown process were discussed. An improved one-dimensional gas thermo-hydrodynamic model was applied to qualitatively investigate the influence of the pressure on neutral gas density evolution over time. The radial distribution of neutral gas density at different recovery time intervals was calculated under various pressures. The results show that a corona-stabilized switch with a higher pressure presents a higher withstand voltage and a better repetitive performance. The repetitve performance of corona-stabilized switches deteriorates with the decrease in pressure.