Jiang Pan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jiang Pan has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Jianping Sun
National Institute of Metrology, Beijing, China
5 shared publications Ting Li
Division of Thermophysics Metrology, National Institute of Metrology, Beijing, People’s Republic of China
2 shared publications- Athikom Manoi
National Institute of Metrology (Thailand), Pathumthani, Thailand
1 shared publication - Chuanjie Wei
Key Laboratory of Ocean Observation and Forecasting & Laboratory of Ocean Circulation and Waves Institute of Oceanology Chinese Academy of Sciences Qingdao China
1 shared publication Fu-Guang Diao
National Institute of Metrology, Beijing, China
1 shared publicationGuang-Yao Wang
National Institute of Metrology, Beijing, China
1 shared publication
Latest Publications
- 6 January 2025
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 36 (2) , 025004
Study on the reproduction method of miniature Ga fixed points for shipborne thermometer calibration
The onsite calibration precision of the ocean thermometer can be efficiently raised by temperature scale transfer technology based on miniature fixed points. A new reproduction method of miniature Ga fixed points was studied for the sub-millikelvin precision measurement requirement. The onsite calibration system consists of a miniature Ga fixed point and a shipborne calibration device. The performance of miniature Ga fixed point is highly dependent on placement methods and the value-taking methods of phase transition temperature. This paper analyzed and compared the melting plateau of a miniature Ga fixed point with two placement methods and three value-taking methods of phase transition temperatures. The experimental results showed that utilizing horizontal placement and the average value method can achieve fixed point reproducibility within 1 mK. The performance of the miniature Ga fixed point was verified using the SBE 3plus thermometer from the SBE 911plus CTD system, with a thermometer accuracy of ±1 mK. The difference between the measured value by SBE 3plus and the Ga melting plateau value was within 0.5 mK. Thus, the study of the miniature Ga fixed point offers effective technical support for the onsite calibration of ocean thermometer.
- 6 January 2025
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 36 (2) , 025004
Study on the reproduction method of miniature Ga fixed points for shipborne thermometer calibration
The onsite calibration precision of the ocean thermometer can be efficiently raised by temperature scale transfer technology based on miniature fixed points. A new reproduction method of miniature Ga fixed points was studied for the sub-millikelvin precision measurement requirement. The onsite calibration system consists of a miniature Ga fixed point and a shipborne calibration device. The performance of miniature Ga fixed point is highly dependent on placement methods and the value-taking methods of phase transition temperature. This paper analyzed and compared the melting plateau of a miniature Ga fixed point with two placement methods and three value-taking methods of phase transition temperatures. The experimental results showed that utilizing horizontal placement and the average value method can achieve fixed point reproducibility within 1 mK. The performance of the miniature Ga fixed point was verified using the SBE 3plus thermometer from the SBE 911plus CTD system, with a thermometer accuracy of ±1 mK. The difference between the measured value by SBE 3plus and the Ga melting plateau value was within 0.5 mK. Thus, the study of the miniature Ga fixed point offers effective technical support for the onsite calibration of ocean thermometer.
- 15 December 2023
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 45 (1) , 1-15
Reproducibility and Assignment of Phenol Temperature Fixed Point
- 15 December 2023
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 45 (1) , 1-15
Reproducibility and Assignment of Phenol Temperature Fixed Point
- 14 April 2021
- Published by IOP Publishing in Metrologia
- Vol. 58 (3) , 035008
Realization and evaluation of the triple point of sulfur hexafluoride
In this study, we realized the triple point (TP) temperature of sulfur hexafluoride (SF 6 ) at the National Institute of Metrology (NIM), China. To this end, we designed an iso-thermal and immersion type apparatus with an open cell with a height of 18 cm, diameter of 5 cm, and a capacity of approximately 275 ml. The cell was designed with four thermometer wells for the simultaneous temperature measurements with four standard platinum resistance thermometers (SPRTs). The cell is connected with two buffer tanks that allow a sufficient amount of SF 6 to surround the thermometer wells during the solidification and melting processes to ensure stable temperature plateaus with long durations. An SF 6 sample with a purity of 99.9997%, which is the highest purity currently available, was supplied and analyzed from the Korea Research Institute of Standards and Science. The SF 6 TP temperature was determined using four long-stem SPRTs. The melting plateaus obtained had a duration longer than 15 h, and the TP temperature of SF 6 was determined to be 223.556 03(54) K ( k = 1). These results are consistent with those of previous studies and further indicate that the SF 6 TP is a good candidate to replace mercury TP, which is one of the fixed points defined in the International Temperature Scale of 1990, for the calibration of SPRTs.
- 14 April 2021
- Published by IOP Publishing in Metrologia
- Vol. 58 (3) , 035008
Realization and evaluation of the triple point of sulfur hexafluoride
In this study, we realized the triple point (TP) temperature of sulfur hexafluoride (SF 6 ) at the National Institute of Metrology (NIM), China. To this end, we designed an iso-thermal and immersion type apparatus with an open cell with a height of 18 cm, diameter of 5 cm, and a capacity of approximately 275 ml. The cell was designed with four thermometer wells for the simultaneous temperature measurements with four standard platinum resistance thermometers (SPRTs). The cell is connected with two buffer tanks that allow a sufficient amount of SF 6 to surround the thermometer wells during the solidification and melting processes to ensure stable temperature plateaus with long durations. An SF 6 sample with a purity of 99.9997%, which is the highest purity currently available, was supplied and analyzed from the Korea Research Institute of Standards and Science. The SF 6 TP temperature was determined using four long-stem SPRTs. The melting plateaus obtained had a duration longer than 15 h, and the TP temperature of SF 6 was determined to be 223.556 03(54) K ( k = 1). These results are consistent with those of previous studies and further indicate that the SF 6 TP is a good candidate to replace mercury TP, which is one of the fixed points defined in the International Temperature Scale of 1990, for the calibration of SPRTs.
- 26 June 2020
- Published by IOP Publishing in Metrologia
- Vol. 57 (4) , 045001
New interpolating equations of ITS-90 for SPRTs and HTSPRTs for the temperature range 419.527 ° C–961.78 ° C
The subrange inconsistency (SRI) of the International Temperature Scale of 1990 (ITS-90) arises from the use of different interpolating equations for the same standard platinum resistance thermometers (SPRTs), called Type 1 non-uniqueness, and is a significant component of the uncertainty in the realization of the scale. In order to eliminate the SRI, new interpolating equations were proposed for the subranges 0.01 ° C to 660.323 ° C and 0.01 ° C to 961.78 ° C, in which the subrange to the zinc point (419.527 ° C) was extended using two additional terms without any overlap. This study investigated 30 SPRTs calibrated over the temperature range of 0.01 ° C–660.323 ° C and 19 high-temperature SPRTs (HTSPRTs) calibrated over 0.01 ° C–961.78 ° C at the National Institute of Metrology (NIM). The feasibility of the proposed equations were evaluated by comparing them with the equations defined in ITS-90 and calculating the propagation uncertainties. The results show that the differences between the defined interpolating equations in ITS-90 and the proposed interpolating equations are generally within ± 0.4 mK for temperature range of 419.527 ° C–961.78 ° C, which is close to or less than the SRIs between the water-zinc and water-aluminium subranges. The propagated uncertainties of the proposed equations were within reasonable limits. It is concluded that these new interpolating equations can be taken as equivalent to the ITS-90 interpolating equations with the SRI eliminated.
- 26 June 2020
- Published by IOP Publishing in Metrologia
- Vol. 57 (4) , 045001
New interpolating equations of ITS-90 for SPRTs and HTSPRTs for the temperature range 419.527 ° C–961.78 ° C
The subrange inconsistency (SRI) of the International Temperature Scale of 1990 (ITS-90) arises from the use of different interpolating equations for the same standard platinum resistance thermometers (SPRTs), called Type 1 non-uniqueness, and is a significant component of the uncertainty in the realization of the scale. In order to eliminate the SRI, new interpolating equations were proposed for the subranges 0.01 ° C to 660.323 ° C and 0.01 ° C to 961.78 ° C, in which the subrange to the zinc point (419.527 ° C) was extended using two additional terms without any overlap. This study investigated 30 SPRTs calibrated over the temperature range of 0.01 ° C–660.323 ° C and 19 high-temperature SPRTs (HTSPRTs) calibrated over 0.01 ° C–961.78 ° C at the National Institute of Metrology (NIM). The feasibility of the proposed equations were evaluated by comparing them with the equations defined in ITS-90 and calculating the propagation uncertainties. The results show that the differences between the defined interpolating equations in ITS-90 and the proposed interpolating equations are generally within ± 0.4 mK for temperature range of 419.527 ° C–961.78 ° C, which is close to or less than the SRIs between the water-zinc and water-aluminium subranges. The propagated uncertainties of the proposed equations were within reasonable limits. It is concluded that these new interpolating equations can be taken as equivalent to the ITS-90 interpolating equations with the SRI eliminated.
- 10 March 2020
- Published by IOP Publishing in Metrologia
- Vol. 57 (2) , 024003
Calibration of a W/Re thermocouple using Pd-C, Pt-C and Ru-C eutectic cells at NIM
In the paper, an in-house W/Re thermocouple was calibrated at the eutectic fixed points of Pd-C (1492 °C), Pt-C (1738 °C) and Ru-C (1953 °C). To correct the temperature error caused by the thermal conduction of the thermocouple sheath, a linear extrapolation method was developed to determine the emf of the thermocouple based on the melting and freezing values at the eutectic fixed points realized with different offset furnace temperatures. In a simpler approach, the average of the melting and freezing values was also used. The results showed that the temperatures corresponding to the emfs derived from the linear extrapolation and the average method agreed (1–2) °C with the standard reference values of type-C thermocouple in the temperature range studied.
- 10 March 2020
- Published by IOP Publishing in Metrologia
- Vol. 57 (2) , 024003
Calibration of a W/Re thermocouple using Pd-C, Pt-C and Ru-C eutectic cells at NIM
In the paper, an in-house W/Re thermocouple was calibrated at the eutectic fixed points of Pd-C (1492 °C), Pt-C (1738 °C) and Ru-C (1953 °C). To correct the temperature error caused by the thermal conduction of the thermocouple sheath, a linear extrapolation method was developed to determine the emf of the thermocouple based on the melting and freezing values at the eutectic fixed points realized with different offset furnace temperatures. In a simpler approach, the average of the melting and freezing values was also used. The results showed that the temperatures corresponding to the emfs derived from the linear extrapolation and the average method agreed (1–2) °C with the standard reference values of type-C thermocouple in the temperature range studied.
- 21 October 2019
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 31 (1) , 014004
Miniature fixed-point cells for self-calibration of type C high-temperature thermocouples
A high-temperature tungsten-rhenium (W-Re) thermocouple is commonly used at temperatures up to 2000 °C for the high melting temperature of the thermoelement materials. When exposed to high temperatures, a thermocouple can show significant thermoelectric drift, which increases measurement uncertainty. The uncontrolled drift may come from the change in the crystallographic structure, oxidization of the thermoelement materials, interaction between the thermoelement materials and insulator materials and some other unknown reasons. Therefore, periodic recalibration of the thermocouple should be performed; however, sometimes it is not possible to remove the sensor out of the process, especially in some special fields, such as a nuclear power plant. Self-validation methods for thermocouples provide a solution to avoid this drawback. In this paper, miniature eutectic fixed-point cells are presented for self-validation of W-Re thermocouples. To prevent the breakage of the graphite crucible, these cylindrical miniature fixed-point cells contain several small independent crucibles and one thermocouple well, which increase the robustness of the miniature cell. The melting temperature was assigned by a radiation thermometer traced to the primary radiation standard at NIM. The effect of the temperature offset and temperature ramping rate on the melting temperature were checked. The performance of the miniature fixed-point cells and type C thermocouple, including characterization of the stability and repeatability, is presented.
- 21 October 2019
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 31 (1) , 014004
Miniature fixed-point cells for self-calibration of type C high-temperature thermocouples
A high-temperature tungsten-rhenium (W-Re) thermocouple is commonly used at temperatures up to 2000 °C for the high melting temperature of the thermoelement materials. When exposed to high temperatures, a thermocouple can show significant thermoelectric drift, which increases measurement uncertainty. The uncontrolled drift may come from the change in the crystallographic structure, oxidization of the thermoelement materials, interaction between the thermoelement materials and insulator materials and some other unknown reasons. Therefore, periodic recalibration of the thermocouple should be performed; however, sometimes it is not possible to remove the sensor out of the process, especially in some special fields, such as a nuclear power plant. Self-validation methods for thermocouples provide a solution to avoid this drawback. In this paper, miniature eutectic fixed-point cells are presented for self-validation of W-Re thermocouples. To prevent the breakage of the graphite crucible, these cylindrical miniature fixed-point cells contain several small independent crucibles and one thermocouple well, which increase the robustness of the miniature cell. The melting temperature was assigned by a radiation thermometer traced to the primary radiation standard at NIM. The effect of the temperature offset and temperature ramping rate on the melting temperature were checked. The performance of the miniature fixed-point cells and type C thermocouple, including characterization of the stability and repeatability, is presented.