Ramin Banafsche
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ramin Banafsche has a total of 123 co-authors. Here are the top co-authors by number of shared publications:
Thomas Jerkku
Abteilung für Gefäßchirurgie – Vaskuläre und Endovaskuläre Chirurgie, Klinikum der Universität München, Campus Großhadern, München, Deutschland
7 shared publications- Nikolaos Tsilimparis
Department of Vascular Surgery, Ludwig-Maximillian University Hospital, Munich, Germany
6 shared publications Nikolaos Tsilimparis
Department of Vascular and Endovascular Surgery, University Hospital, LMU Munich, Munich, Germany
5 shared publicationsBarbara Rantner
Department of Vascular Surgery, Ludwig-Maximilians-University Hospital , Munich, Germany
4 shared publications- Nikolaos Konstantinou
Department of vascular surgery, University Hospital, LMU Munich, Germany
4 shared publications - Tobias Keck
Department of Surgery, University Medical Center Schleswig-Holstein, Lübeck, Germany
4 shared publications
Latest Publications
- 24 January 2022
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 61 (5) , 1109-1115
Evaluation of a rapid deployment prosthesis strategy for the treatment of aortic valve endocarditis
The aim of this study was to evaluate the surgical outcome of patients suffering from native aortic valve (NVE) or prosthetic aortic valve endocarditis (PVE) treated with the EDWARDS INTUITY Elite rapid-deployment valve prosthesis. Between February 2019 and June 2020, 25 patients suffering from NVE (n = 9; 36%) and PVE (n = 16; 64%) of the aortic valve received an INTUITY valve at our institution. Preoperative, operative and follow-up data were collected. In our cohort, the mean EuroSCORE II was 13.4%. Eleven patients (44%) received concomitant aortic root patch plasty. Four patients (16%) received coronary artery bypass graft surgery, 3 patients (12%) received mitral valve repair and 2 patients (8%) underwent replacement of the ascending aorta. The cardiopulmonary bypass and aortic cross-clamp times were 124 ± 56 and 75 ± 39 min, respectively. The mean intensive care unit stay was 5 days. The mean size of the implanted prostheses was 25 ± 2 mm and the mean prosthesis transvalvular gradient 3 months after surgery was 9 ± 4 mmHg. During follow-up, no case of recurrent endocarditis occurred, 1 patient died of multisystem organ failure which had already been present preoperatively. Surgery for NVE and PVE of the aortic valve may be safely performed using the EDWARDS INTUITY Elite valve system. This procedure could be well implemented in cases with extensive infection, fragile root tissue and root abscesses requiring root reconstruction. In our institution, the rapid-deployment aortic valve replacement strategy has become an important tool in the armamentarium of the surgical endocarditis treatment.
- 24 January 2022
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 61 (5) , 1109-1115
Evaluation of a rapid deployment prosthesis strategy for the treatment of aortic valve endocarditis
The aim of this study was to evaluate the surgical outcome of patients suffering from native aortic valve (NVE) or prosthetic aortic valve endocarditis (PVE) treated with the EDWARDS INTUITY Elite rapid-deployment valve prosthesis. Between February 2019 and June 2020, 25 patients suffering from NVE (n = 9; 36%) and PVE (n = 16; 64%) of the aortic valve received an INTUITY valve at our institution. Preoperative, operative and follow-up data were collected. In our cohort, the mean EuroSCORE II was 13.4%. Eleven patients (44%) received concomitant aortic root patch plasty. Four patients (16%) received coronary artery bypass graft surgery, 3 patients (12%) received mitral valve repair and 2 patients (8%) underwent replacement of the ascending aorta. The cardiopulmonary bypass and aortic cross-clamp times were 124 ± 56 and 75 ± 39 min, respectively. The mean intensive care unit stay was 5 days. The mean size of the implanted prostheses was 25 ± 2 mm and the mean prosthesis transvalvular gradient 3 months after surgery was 9 ± 4 mmHg. During follow-up, no case of recurrent endocarditis occurred, 1 patient died of multisystem organ failure which had already been present preoperatively. Surgery for NVE and PVE of the aortic valve may be safely performed using the EDWARDS INTUITY Elite valve system. This procedure could be well implemented in cases with extensive infection, fragile root tissue and root abscesses requiring root reconstruction. In our institution, the rapid-deployment aortic valve replacement strategy has become an important tool in the armamentarium of the surgical endocarditis treatment.
- 28 September 2021
- Published by Wolters Kluwer Health in Circulation
- Vol. 144 (13) , 1059-1073
MicroRNA-21 Controls Circadian Regulation of Apoptosis in Atherosclerotic Lesions
Background: The necrotic core partly formed by ineffective efferocytosis increases the risk of an atherosclerotic plaque rupture. Microribonucleic acids contribute to necrotic core formation by regulating efferocytosis and macrophage apoptosis. Atherosclerotic plaque rupture occurs at increased frequency in the early morning, indicating diurnal changes in plaque vulnerability. Although circadian rhythms play a role in atherosclerosis, the molecular clock output pathways that control plaque composition and rupture susceptibility are unclear. Methods: Circadian gene expression, necrotic core size, apoptosis, and efferocytosis in aortic lesions were investigated at different times of the day in Apoe –/– Mir21 +/+ mice and Apoe –/– Mir21 –/– mice after consumption of a high-fat diet for 12 weeks. Genome-wide gene expression and lesion formation were analyzed in bone marrow–transplanted mice. Diurnal changes in apoptosis and clock gene expression were determined in human atherosclerotic lesions. Results: The expression of molecular clock genes, lesional apoptosis, and necrotic core size were diurnally regulated in Apoe –/– mice. Efferocytosis did not match the diurnal increase in apoptosis at the beginning of the active phase. However, in parallel with apoptosis, expression levels of oscillating Mir21 strands decreased in the mouse atherosclerotic aorta. Mir21 knockout abolished circadian regulation of apoptosis and reduced necrotic core size but did not affect core clock gene expression. Further, Mir21 knockout upregulated expression of proapoptotic Xaf1 (XIAP-associated factor 1) in the atherosclerotic aorta, which abolished circadian expression of Xaf1. The antiapoptotic effect of Mir21 was mediated by noncanonical targeting of Xaf1 through both Mir21 strands. Mir21 knockout in bone marrow cells also reduced atherosclerosis and necrotic core size. Circadian regulation of clock gene expression was confirmed in human atherosclerotic lesions. Apoptosis oscillated diurnally in phase with XAF1 expression, demonstrating an early morning peak antiphase to that of the Mir21 strands. Conclusions: Our findings suggest that the molecular clock in atherosclerotic lesions induces a diurnal rhythm of apoptosis regulated by circadian Mir21 expression in macrophages that is not matched by efferocytosis, thus increasing the size of the necrotic core.
- 28 September 2021
- Published by Wolters Kluwer Health in Circulation
- Vol. 144 (13) , 1059-1073
MicroRNA-21 Controls Circadian Regulation of Apoptosis in Atherosclerotic Lesions
Background: The necrotic core partly formed by ineffective efferocytosis increases the risk of an atherosclerotic plaque rupture. Microribonucleic acids contribute to necrotic core formation by regulating efferocytosis and macrophage apoptosis. Atherosclerotic plaque rupture occurs at increased frequency in the early morning, indicating diurnal changes in plaque vulnerability. Although circadian rhythms play a role in atherosclerosis, the molecular clock output pathways that control plaque composition and rupture susceptibility are unclear. Methods: Circadian gene expression, necrotic core size, apoptosis, and efferocytosis in aortic lesions were investigated at different times of the day in Apoe –/– Mir21 +/+ mice and Apoe –/– Mir21 –/– mice after consumption of a high-fat diet for 12 weeks. Genome-wide gene expression and lesion formation were analyzed in bone marrow–transplanted mice. Diurnal changes in apoptosis and clock gene expression were determined in human atherosclerotic lesions. Results: The expression of molecular clock genes, lesional apoptosis, and necrotic core size were diurnally regulated in Apoe –/– mice. Efferocytosis did not match the diurnal increase in apoptosis at the beginning of the active phase. However, in parallel with apoptosis, expression levels of oscillating Mir21 strands decreased in the mouse atherosclerotic aorta. Mir21 knockout abolished circadian regulation of apoptosis and reduced necrotic core size but did not affect core clock gene expression. Further, Mir21 knockout upregulated expression of proapoptotic Xaf1 (XIAP-associated factor 1) in the atherosclerotic aorta, which abolished circadian expression of Xaf1. The antiapoptotic effect of Mir21 was mediated by noncanonical targeting of Xaf1 through both Mir21 strands. Mir21 knockout in bone marrow cells also reduced atherosclerosis and necrotic core size. Circadian regulation of clock gene expression was confirmed in human atherosclerotic lesions. Apoptosis oscillated diurnally in phase with XAF1 expression, demonstrating an early morning peak antiphase to that of the Mir21 strands. Conclusions: Our findings suggest that the molecular clock in atherosclerotic lesions induces a diurnal rhythm of apoptosis regulated by circadian Mir21 expression in macrophages that is not matched by efferocytosis, thus increasing the size of the necrotic core.
- 9 April 2021
- Published by SAGE Publications in Journal of Endovascular Therapy
- Vol. 28 (4) , 510-518
Technical Aspects of Fenestrated Arch TEVAR With Preloaded Fenestration
Fenestrated thoracic endovascular aortic repair (f-TEVAR) has expanded the possibilities of endovascular arch repair, allowing treatment of pathologies involving the aortic arch that require sealing in Ishimaru zones 1 and 2. The growing number of implantations has increased physician experience and helped identify critical procedural points, mainly wire entanglement and device malrotation. Herein we describe a step-by-step approach to a f-TEVAR procedure with the Zenith fenestrated preloaded thoracic endograft, identifying potential pitfalls and suggesting problem-solving solutions.
- 9 April 2021
- Published by SAGE Publications in Journal of Endovascular Therapy
- Vol. 28 (4) , 510-518
Technical Aspects of Fenestrated Arch TEVAR With Preloaded Fenestration
Fenestrated thoracic endovascular aortic repair (f-TEVAR) has expanded the possibilities of endovascular arch repair, allowing treatment of pathologies involving the aortic arch that require sealing in Ishimaru zones 1 and 2. The growing number of implantations has increased physician experience and helped identify critical procedural points, mainly wire entanglement and device malrotation. Herein we describe a step-by-step approach to a f-TEVAR procedure with the Zenith fenestrated preloaded thoracic endograft, identifying potential pitfalls and suggesting problem-solving solutions.
- 29 March 2021
- Published by Oxford University Press (OUP) in Interactive CardioVascular and Thoracic Surgery
- Vol. 33 (2) , 293-300
Blunt traumatic thoracic aortic injuries: a retrospective cohort analysis of 2 decades of experience
OBJECTIVES: The aim of this study was to analyse and report the changes in the management of blunt traumatic aortic injuries (BTAIs) in a single centre during the last 2 decades. METHODS: A retrospective analysis of all patients diagnosed with BTAI from January 1999 to January 2020 was performed. Data were collected from electronic/digitalized medical history records. RESULTS: Forty-six patients were included [median age 42.4 years (16–84 years), 71.7% males]. The predominant cause of BTAI was car accidents (54.5%, n = 24) and all patients presented with concomitant injuries (93% bone fractures, 77.8% abdominal and 62.2% pelvic injuries). Over 70% presented grade III or IV BTAI. Urgent repair was performed in 73.8% of patients (n = 31), with a median of 2.75 h between admission and repair. Thoracic endovascular repair (TEVAR) was performed in 87% (n = 49), open surgery (OS) in 10.9% (n = 5) and conservative management in 2.1% (n = 1). Technical success was 82.6% (92.1% TEVAR, 79% OS). In-hospital mortality was 19.5% (17.5% TEVAR, 40% OS). Of these, 3 died from aortic-related causes. Seven (15.2%) required an early vascular reintervention. The median follow-up was 34 months (1–220 months), with 19% of early survivors having a follow-up of >10 years. Only 1 vascular reintervention was necessary during follow-up: secondary TEVAR due to acute graft thrombosis. Of the patients who survived the initial event, 6.7% died during follow-up, none from aortic-related causes. CONCLUSIONS: Even with all the described shortcomings, in our experience TEVAR for BTAI proved to be feasible and effective, with few complications and stable aortic reconstruction at mid-term follow-up. With the current technical expertise and wide availability of a variety of devices, it should be pursued as a first-line therapy in these challenging scenarios.
- 29 March 2021
- Published by Oxford University Press (OUP) in Interactive CardioVascular and Thoracic Surgery
- Vol. 33 (2) , 293-300
Blunt traumatic thoracic aortic injuries: a retrospective cohort analysis of 2 decades of experience
OBJECTIVES: The aim of this study was to analyse and report the changes in the management of blunt traumatic aortic injuries (BTAIs) in a single centre during the last 2 decades. METHODS: A retrospective analysis of all patients diagnosed with BTAI from January 1999 to January 2020 was performed. Data were collected from electronic/digitalized medical history records. RESULTS: Forty-six patients were included [median age 42.4 years (16–84 years), 71.7% males]. The predominant cause of BTAI was car accidents (54.5%, n = 24) and all patients presented with concomitant injuries (93% bone fractures, 77.8% abdominal and 62.2% pelvic injuries). Over 70% presented grade III or IV BTAI. Urgent repair was performed in 73.8% of patients (n = 31), with a median of 2.75 h between admission and repair. Thoracic endovascular repair (TEVAR) was performed in 87% (n = 49), open surgery (OS) in 10.9% (n = 5) and conservative management in 2.1% (n = 1). Technical success was 82.6% (92.1% TEVAR, 79% OS). In-hospital mortality was 19.5% (17.5% TEVAR, 40% OS). Of these, 3 died from aortic-related causes. Seven (15.2%) required an early vascular reintervention. The median follow-up was 34 months (1–220 months), with 19% of early survivors having a follow-up of >10 years. Only 1 vascular reintervention was necessary during follow-up: secondary TEVAR due to acute graft thrombosis. Of the patients who survived the initial event, 6.7% died during follow-up, none from aortic-related causes. CONCLUSIONS: Even with all the described shortcomings, in our experience TEVAR for BTAI proved to be feasible and effective, with few complications and stable aortic reconstruction at mid-term follow-up. With the current technical expertise and wide availability of a variety of devices, it should be pursued as a first-line therapy in these challenging scenarios.
- 1 October 2020
- Published by Georg Thieme Verlag KG in Zentralblatt fur Chirurgie
- Vol. 145 (05) , 432-437
Aortic Aneurysm: Fenestrated/Branched Endovascular Aortic Repair (EVAR) and Fenestrated/Branched Thoracic Endovascular Aortic Repair (TEVAR). Is Total Endovascular Repair Already Here?
Five years after the first endovascular aortic repair (EVAR), Park et al. reported the first implantation of a fenestrated endoprosthesis. In the meantime, advanced generations of new fenestrated and branched endografts evolved. Endografts for complex pathologies are either so-called "off-the-shelf" grafts with predetermined length, width, diameter and clock position of the branches and fenestrations, predetermined by the manufacturer, "custom-made" grafts which need to be sized and planned individually for patients with specific thoracoabdominal anatomy. Open aortic repair in the treatment of thoracoabdominal aortic aneurysm (TAAA) still remains challenging and is associated with high morbidity and mortality, even in the elective setting. The ongoing development of endovascular treatment modalities, such as fenestrated and branched endovascular aneurysm repair (F-EVAR, B-EVAR), enables less invasive procedures for more challenging aortic pathologies. In recent years, extensive endovascular treatment of the aortic arch to the thoracoabdominal segment has become more and more important, but its outcomes have not been completely evaluated. The aim of this is article is to provide an overview of the currently available endovascular treatment options for complex aortic aneurysms requiring extensive coverage from the aortic arch to the infrarenal aorta.
- 1 October 2020
- Published by Georg Thieme Verlag KG in Zentralblatt fur Chirurgie
- Vol. 145 (05) , 432-437
Aortic Aneurysm: Fenestrated/Branched Endovascular Aortic Repair (EVAR) and Fenestrated/Branched Thoracic Endovascular Aortic Repair (TEVAR). Is Total Endovascular Repair Already Here?
Five years after the first endovascular aortic repair (EVAR), Park et al. reported the first implantation of a fenestrated endoprosthesis. In the meantime, advanced generations of new fenestrated and branched endografts evolved. Endografts for complex pathologies are either so-called "off-the-shelf" grafts with predetermined length, width, diameter and clock position of the branches and fenestrations, predetermined by the manufacturer, "custom-made" grafts which need to be sized and planned individually for patients with specific thoracoabdominal anatomy. Open aortic repair in the treatment of thoracoabdominal aortic aneurysm (TAAA) still remains challenging and is associated with high morbidity and mortality, even in the elective setting. The ongoing development of endovascular treatment modalities, such as fenestrated and branched endovascular aneurysm repair (F-EVAR, B-EVAR), enables less invasive procedures for more challenging aortic pathologies. In recent years, extensive endovascular treatment of the aortic arch to the thoracoabdominal segment has become more and more important, but its outcomes have not been completely evaluated. The aim of this is article is to provide an overview of the currently available endovascular treatment options for complex aortic aneurysms requiring extensive coverage from the aortic arch to the infrarenal aorta.
- 1 August 2020
- Published by Elsevier in Journal of Vascular Surgery
- Vol. 72 (2) , 716-725.e1
Systematic review and meta-analysis of published studies on endovascular repair of thoracoabdominal aortic aneurysms with the t-Branch off-the-shelf multibranched endograft
- 1 August 2020
- Published by Elsevier in Journal of Vascular Surgery
- Vol. 72 (2) , 716-725.e1
Systematic review and meta-analysis of published studies on endovascular repair of thoracoabdominal aortic aneurysms with the t-Branch off-the-shelf multibranched endograft
- 16 January 2020
- Published by SAGE Publications in Journal of Endovascular Therapy
- Vol. 27 (1) , 130-131
Commentary: Physician-Modified Endografts: Surmounting Anatomical Challenges With Innovative Techniques to Optimize Treatment
- 16 January 2020
- Published by SAGE Publications in Journal of Endovascular Therapy
- Vol. 27 (1) , 130-131
Commentary: Physician-Modified Endografts: Surmounting Anatomical Challenges With Innovative Techniques to Optimize Treatment
- 1 January 2020
- Published by Elsevier in Annals of Vascular Surgery
- Vol. 62, 195-205
Extension of Iliac Branch Device Repair Into the Superior Gluteal Artery Is a Safe and Effective Maneuver
- 1 January 2020
- Published by Elsevier in Annals of Vascular Surgery
- Vol. 62, 195-205
Extension of Iliac Branch Device Repair Into the Superior Gluteal Artery Is a Safe and Effective Maneuver
- 30 August 2019
- Published by SAGE Publications in Journal of Endovascular Therapy
- Vol. 26 (5) , 633-636
Commentary: What ILIACS Can Tell Us – Future Perspectives of Endovascular AIOD Treatment
- 30 August 2019
- Published by SAGE Publications in Journal of Endovascular Therapy
- Vol. 26 (5) , 633-636
Commentary: What ILIACS Can Tell Us – Future Perspectives of Endovascular AIOD Treatment