Harun Mutlu
Research Subjects
Harun Mutlu has a total of 53 co-authors. Here are the top co-authors by number of shared publications:
- Serhat Mutlu
Department of Orthopaedics, Kanuni Sultan Suleyman Training and Research Hospital, Istanbul, Turkey
7 shared publications - Mehmet Isyar
Department of Orthopaedic and Traumatology, Istanbul Medipol University School of Medicine, 34214, Istanbul, Turkey
3 shared publications Baran Komur
Orthopaedic Surgeon, Department of Orthopaedics, Kanuni Sultan Süleyman Training and Research Hospital, Istanbul, Turkey
2 shared publicationsBulent Yucel
2 shared publications- Fırat Fidan
İstanbul Aydın Üniversitesi Tıp Fakültesi
2 shared publications Mahir Mahirogullari
Professor, Department of Orthopaedics, Istanbul Medipol University Hospital, Istanbul, Turkey
2 shared publications
Latest Publications
- 14 March 2023
- Published by Nobel Tip Kitabevleri
- p. 41-54
Treatment
- 12 January 2022
- Published by SAGE Publications in Journal of Back and Musculoskeletal Rehabilitation
- Vol. 35 (1) , 169-175
Anthropometry of the knee of the Turkish population and the comparison to implant sizes in total knee arthroplasty
BACKGROUND: Total knee arthroplasty (TKA) is one of the most common orthopaedic surgical procedures in the advanced stages of knee arthritis. OBJECTIVE: The purpose of this study was to define the sex differences in the Turkish population’s morphological measurements of the distal femoral and proximal tibial surfaces that form the knee joint and to compare their compatibility with conventional prosthetic implants commonly used in TKA for advanced-stage knee arthritis. METHODS: Anthropometric data for a total of 240 knees from 240 patients were measured using 3-dimensional computed tomography (3D CT). All morphological data were compared with the dimensions of four conventional knee prostheses commonly used in Turkey. RESULTS: A comparison of the four tibial components revealed that the majority of female proximal tibias matched with smaller-sized tibial components, whereas those of males matched the larger sizes. Comparing the morphological data with similar values for the four femoral components currently used in Turkey, we found that all the prostheses had similar values. CONCLUSION: The four conventional prosthetic brands included in this study matched the distal femoral dimensions of both sexes. On the other hand, we need smaller size tibial components for our female population.
- 12 January 2022
- Published by SAGE Publications in Journal of Back and Musculoskeletal Rehabilitation
- Vol. 35 (1) , 169-175
Anthropometry of the knee of the Turkish population and the comparison to implant sizes in total knee arthroplasty
BACKGROUND: Total knee arthroplasty (TKA) is one of the most common orthopaedic surgical procedures in the advanced stages of knee arthritis. OBJECTIVE: The purpose of this study was to define the sex differences in the Turkish population’s morphological measurements of the distal femoral and proximal tibial surfaces that form the knee joint and to compare their compatibility with conventional prosthetic implants commonly used in TKA for advanced-stage knee arthritis. METHODS: Anthropometric data for a total of 240 knees from 240 patients were measured using 3-dimensional computed tomography (3D CT). All morphological data were compared with the dimensions of four conventional knee prostheses commonly used in Turkey. RESULTS: A comparison of the four tibial components revealed that the majority of female proximal tibias matched with smaller-sized tibial components, whereas those of males matched the larger sizes. Comparing the morphological data with similar values for the four femoral components currently used in Turkey, we found that all the prostheses had similar values. CONCLUSION: The four conventional prosthetic brands included in this study matched the distal femoral dimensions of both sexes. On the other hand, we need smaller size tibial components for our female population.
- Open Access
- 1 January 2022
- Published by FapUNIFESP (SciELO) in Acta Ortopedica Brasileira
- Vol. 30 (spe1) , e246613
HOW USEFUL IS ELASTOGRAPHY IN THE FOLLOW-UP OF ACHILLES TENDON REPAIR?
Introduction: In addition to conservative modalities in the treatment of Achilles tendon injuries, open, percutaneous and minimally invasive semi-open techniques, as well as biological open surgical repair methods are used as surgical options. Compression elastography is one of the methods used for the follow-up of treatment in Achilles tendon injuries. Methods: 23 patients were included in our study between July 2013 and June 2014, as long as they had at least 4 years of follow-up. In the final control, the intact side and the operated side were both examined and compared. The variables were the American Orthopedic Foot and Ankle Score (AOFAS) which is measured as a functional score considering plantar flexion and dorsiflexion; calf circumference; Achilles tendon anteroposterior (AP) diameter; and elastographic examination. Results: The strain ratio value and AP diameter of the patients was significantly higher on the operated side than on the non-operated side (p 0.05). No correlation was observed between strain ratio and AOFAS (p: 0,995). Conclusion: Elastography is not a useful technique to evaluate functional results on long-term tendon healing. Level of Evidence III; Retrospective comparative study.
- 1 January 2022
- Published by FapUNIFESP (SciELO) in Acta Ortopedica Brasileira
- Vol. 30 (spe1) , e246613
Open AccessHOW USEFUL IS ELASTOGRAPHY IN THE FOLLOW-UP OF ACHILLES TENDON REPAIR?
Introduction: In addition to conservative modalities in the treatment of Achilles tendon injuries, open, percutaneous and minimally invasive semi-open techniques, as well as biological open surgical repair methods are used as surgical options. Compression elastography is one of the methods used for the follow-up of treatment in Achilles tendon injuries. Methods: 23 patients were included in our study between July 2013 and June 2014, as long as they had at least 4 years of follow-up. In the final control, the intact side and the operated side were both examined and compared. The variables were the American Orthopedic Foot and Ankle Score (AOFAS) which is measured as a functional score considering plantar flexion and dorsiflexion; calf circumference; Achilles tendon anteroposterior (AP) diameter; and elastographic examination. Results: The strain ratio value and AP diameter of the patients was significantly higher on the operated side than on the non-operated side (p 0.05). No correlation was observed between strain ratio and AOFAS (p: 0,995). Conclusion: Elastography is not a useful technique to evaluate functional results on long-term tendon healing. Level of Evidence III; Retrospective comparative study.
- Open Access
- 1 January 2022
- Published by FapUNIFESP (SciELO) in Acta Ortopedica Brasileira
- Vol. 30 (1) , e248473
A NEW ANATOMICAL PLATE FOR EXTRA-ARTICULAR DISTAL HUMERAL FRACTURES: BIOMECHANICAL STUDY
Introduction We compared the mechanical properties of two fixation techniques for the treatment of extra-articular distal third humeral fractures. Materials and Methods Two groups were created from twenty-four humeri. Group 1 was instrumented using a new, precontoured, 8-hole (3.5-mm-diameter) locking compression plate (LCP) placed anterolaterally. Group 2 was instrumented using an 8-hole (3.5-mm-diameter) precontoured posterolateral LCP plate placed on the distal humerus. Four-point bending tests and torsion tests were performed until the specimens broke. Results The four-point bending stiffness test showed that the stiffness of anterolaterally fixed humeri was significantly higher than that of posterolaterally fixed humeri (p<0.05). Torsion testing revealed that posterolateral fixation was associated with better yield strength (p 0.05). Conclusions The anterolateral plate exhibited higher bending stiffness and torsional yield strength than the posterolateral plate. Anterolateral plate fixation can thus be used to manage extra-articular distal humeral fractures. Multiaxial locking screws ensure rigid fixation, allow early elbow motion without olecranon fossa impingement, and prevent iatrogenic injury of the triceps muscle. Level of Evidence I, Therapeutic Studies Investigating the Results of Treatment.
- 1 January 2022
- Published by FapUNIFESP (SciELO) in Acta Ortopedica Brasileira
- Vol. 30 (1) , e248473
Open AccessA NEW ANATOMICAL PLATE FOR EXTRA-ARTICULAR DISTAL HUMERAL FRACTURES: BIOMECHANICAL STUDY
Introduction We compared the mechanical properties of two fixation techniques for the treatment of extra-articular distal third humeral fractures. Materials and Methods Two groups were created from twenty-four humeri. Group 1 was instrumented using a new, precontoured, 8-hole (3.5-mm-diameter) locking compression plate (LCP) placed anterolaterally. Group 2 was instrumented using an 8-hole (3.5-mm-diameter) precontoured posterolateral LCP plate placed on the distal humerus. Four-point bending tests and torsion tests were performed until the specimens broke. Results The four-point bending stiffness test showed that the stiffness of anterolaterally fixed humeri was significantly higher than that of posterolaterally fixed humeri (p<0.05). Torsion testing revealed that posterolateral fixation was associated with better yield strength (p 0.05). Conclusions The anterolateral plate exhibited higher bending stiffness and torsional yield strength than the posterolateral plate. Anterolateral plate fixation can thus be used to manage extra-articular distal humeral fractures. Multiaxial locking screws ensure rigid fixation, allow early elbow motion without olecranon fossa impingement, and prevent iatrogenic injury of the triceps muscle. Level of Evidence I, Therapeutic Studies Investigating the Results of Treatment.
- 1 May 2017
- Published by SLACK, Inc. in Orthopedics
- Vol. 40 (3) , e532-e537
Comparison of Anteromedial and Transtibial ACL Reconstruction Using Expandable Fixation
The influence of anatomical or nonanatomical femoral tunnel position on tunnel widening and clinical outcomes in patients undergoing anterior cruciate ligament (ACL) reconstruction is not fully understood. This retrospective study examined the influence of tunnel width and placement on anterior knee stability and clinical outcomes after ACL reconstruction using the AperFix System (Cayenne Medical Inc, Scottsdale, Arizona), a direct expandable fixation technique with autologous hamstring grafts. The records of 80 patients (79 men and 1 woman) who underwent ACL reconstruction were evaluated. In 38 patients, anatomical femoral tunnel placement was performed via an accessory medial portal (anteromedial group); in the remaining 42 patients, the femoral tunnel was positioned nonanatomically using a transtibial technique (transtibial group). Mean follow-up was 40.7 months (range, 27-60 months). Postoperative knee kinetics were measured, and clinical outcomes were assessed using International Knee Documentation Committee, Lysholm, and Tegner scores. Femoral tunnel widening was measured by comparing postoperative radiographs with final follow-up radiographs. Femoral tunnel width was significantly greater (P<.001) and anterior knee translation was significantly higher (P=.01) in the transtibial group. Lysholm and Tegner scores were not significantly different (P>.05) between the 2 groups. These findings suggest that femoral tunnel widening is associated with increased anterior joint laxity when a direct fixation technique is used for ACL reconstruction, particularly in nonanatomically positioned femoral tunnels. Anatomical femoral tunnel placement provides better anterior stability and less tunnel widening than transtibial tunnel placement; however, these benefits did not produce a detectable advantage in clinical outcomes measures. [Orthopedics. 2017; 40(3):e532-e537.].
- 1 May 2017
- Published by SLACK, Inc. in Orthopedics
- Vol. 40 (3) , e532-e537
Comparison of Anteromedial and Transtibial ACL Reconstruction Using Expandable Fixation
The influence of anatomical or nonanatomical femoral tunnel position on tunnel widening and clinical outcomes in patients undergoing anterior cruciate ligament (ACL) reconstruction is not fully understood. This retrospective study examined the influence of tunnel width and placement on anterior knee stability and clinical outcomes after ACL reconstruction using the AperFix System (Cayenne Medical Inc, Scottsdale, Arizona), a direct expandable fixation technique with autologous hamstring grafts. The records of 80 patients (79 men and 1 woman) who underwent ACL reconstruction were evaluated. In 38 patients, anatomical femoral tunnel placement was performed via an accessory medial portal (anteromedial group); in the remaining 42 patients, the femoral tunnel was positioned nonanatomically using a transtibial technique (transtibial group). Mean follow-up was 40.7 months (range, 27-60 months). Postoperative knee kinetics were measured, and clinical outcomes were assessed using International Knee Documentation Committee, Lysholm, and Tegner scores. Femoral tunnel widening was measured by comparing postoperative radiographs with final follow-up radiographs. Femoral tunnel width was significantly greater (P<.001) and anterior knee translation was significantly higher (P=.01) in the transtibial group. Lysholm and Tegner scores were not significantly different (P>.05) between the 2 groups. These findings suggest that femoral tunnel widening is associated with increased anterior joint laxity when a direct fixation technique is used for ACL reconstruction, particularly in nonanatomically positioned femoral tunnels. Anatomical femoral tunnel placement provides better anterior stability and less tunnel widening than transtibial tunnel placement; however, these benefits did not produce a detectable advantage in clinical outcomes measures. [Orthopedics. 2017; 40(3):e532-e537.].
- Open Access
- 6 January 2017
- Published by AVES YAYINCILIK A.Ş. in Acta Orthopaedica et Traumatologica Turcica
- Vol. 51 (6) , 455-458
Bosworth and modified Phemister techniques revisited. A comparison of intraarticular vs extraarticular fixation methods in the treatment of acute Rockwood type III acromioclavicular dislocations
The aim of this study was to compare the long-term clinical and radiological results of Acromioclavicular (AC) fixation with K-wires (the modified Phemister procedure) and Coracoclavicular (CC) fixation with the Bosworth screw in the surgical treatment of Type 3 AC joint dislocations. Thirty-two patients with complete set of medical records and who received surgical treatment between September 2005 and January 2009 due to acute Rockwood Type 3 AC joint dislocation and properly attended their follow-ups were retrospectively evaluated. Sixteen patients (13 males, 3 females; mean age: 38, range: 24–52 years) were treated with CC fixation with Bosworth screw (Group 1), and the other 16 (12 males, 4 females; mean age: 53.3, range: 38–64 years) with AC fixation using K-wires (Group 2). The mean follow-up time was 96 months for Group 1 and 93 months for Group 2 patients (p > 0.05). The mean Constant–Murley score at the final follow-up was 84.7 in Group 1 and 87.3 in Group 2 (p = 0.069). Radiological evaluation of the patients revealed AC arthrosis in 2 and 3 patients in Group 1 and 2, respectively. In Group 2, one patient had a recurrent dislocation, three patients had AC arthrosis and two patients had ossification in the CC ligament (Fig. 2). There was no superficial or deep wound infection in Group 1, while two patients from Group 2 had a superficial wound infection. Our results suggest that both techniques are reliable and provide adequate reduction and similar outcomes in terms of functionality and pain levels, following the reduction of Type 3 AC joint dislocations. With lower rates of wound site infection in the early and AC arthrosis in the late postoperative period, CC fixation method with the Bosworth screw may be a better surgical option than AC fixation method with K-wires. Level III, Therapeutic study. ER - Keywords Acromioclavicular separation Type 3 separation Bosworth screw Phemister procedure
- 6 January 2017
- Published by AVES YAYINCILIK A.Ş. in Acta Orthopaedica et Traumatologica Turcica
- Vol. 51 (6) , 455-458
Open AccessBosworth and modified Phemister techniques revisited. A comparison of intraarticular vs extraarticular fixation methods in the treatment of acute Rockwood type III acromioclavicular dislocations
The aim of this study was to compare the long-term clinical and radiological results of Acromioclavicular (AC) fixation with K-wires (the modified Phemister procedure) and Coracoclavicular (CC) fixation with the Bosworth screw in the surgical treatment of Type 3 AC joint dislocations. Thirty-two patients with complete set of medical records and who received surgical treatment between September 2005 and January 2009 due to acute Rockwood Type 3 AC joint dislocation and properly attended their follow-ups were retrospectively evaluated. Sixteen patients (13 males, 3 females; mean age: 38, range: 24–52 years) were treated with CC fixation with Bosworth screw (Group 1), and the other 16 (12 males, 4 females; mean age: 53.3, range: 38–64 years) with AC fixation using K-wires (Group 2). The mean follow-up time was 96 months for Group 1 and 93 months for Group 2 patients (p > 0.05). The mean Constant–Murley score at the final follow-up was 84.7 in Group 1 and 87.3 in Group 2 (p = 0.069). Radiological evaluation of the patients revealed AC arthrosis in 2 and 3 patients in Group 1 and 2, respectively. In Group 2, one patient had a recurrent dislocation, three patients had AC arthrosis and two patients had ossification in the CC ligament (Fig. 2). There was no superficial or deep wound infection in Group 1, while two patients from Group 2 had a superficial wound infection. Our results suggest that both techniques are reliable and provide adequate reduction and similar outcomes in terms of functionality and pain levels, following the reduction of Type 3 AC joint dislocations. With lower rates of wound site infection in the early and AC arthrosis in the late postoperative period, CC fixation method with the Bosworth screw may be a better surgical option than AC fixation method with K-wires. Level III, Therapeutic study. ER - Keywords Acromioclavicular separation Type 3 separation Bosworth screw Phemister procedure
- 1 January 2017
- Published by Elsevier in The Journal of Foot and Ankle Surgery
- Vol. 56 (1) , 54-58
Need for Bone Grafts in the Surgical Treatment of Displaced Intra-Articular Calcaneal Fractures
- 1 January 2017
- Published by Elsevier in The Journal of Foot and Ankle Surgery
- Vol. 56 (1) , 54-58
Need for Bone Grafts in the Surgical Treatment of Displaced Intra-Articular Calcaneal Fractures
- 25 January 2016
- Published by SAGE Publications in Journal of Back and Musculoskeletal Rehabilitation
- Vol. 29 (1) , 49-54
The effects of preoperative non-invasive cardiac tests on delay to surgery and subsequent mortality in elderly patients with hip fracture
OBJECTIVE: To investigate the effects of preoperative cardiac tests on the surgical treatment plan and subsequent effects on mortality in elderly patients with hip fracture. To investigate the effects of preoperative cardiac tests on the surgical tre
- 25 January 2016
- Published by SAGE Publications in Journal of Back and Musculoskeletal Rehabilitation
- Vol. 29 (1) , 49-54
The effects of preoperative non-invasive cardiac tests on delay to surgery and subsequent mortality in elderly patients with hip fracture
OBJECTIVE: To investigate the effects of preoperative cardiac tests on the surgical treatment plan and subsequent effects on mortality in elderly patients with hip fracture. To investigate the effects of preoperative cardiac tests on the surgical tre
- 1 January 2016
- Published by Elsevier in The Journal of Foot and Ankle Surgery
- Vol. 55 (1) , 99-105
Pedobarography in the Assessment of Postoperative Calcaneal Fracture Pressure With Gait
- 1 January 2016
- Published by Elsevier in The Journal of Foot and Ankle Surgery
- Vol. 55 (1) , 99-105
Pedobarography in the Assessment of Postoperative Calcaneal Fracture Pressure With Gait
- 1 December 2015
- Published by Elsevier in Journal of Orthopaedics
- Vol. 12 (4) , 205-210
Efficacy of periarticular injection applied trough knee other than posterior capsule in simultaneous bilateral total knee arthroplasty
- 1 December 2015
- Published by Elsevier in Journal of Orthopaedics
- Vol. 12 (4) , 205-210
Efficacy of periarticular injection applied trough knee other than posterior capsule in simultaneous bilateral total knee arthroplasty