Hemang Kotecha
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Hemang Kotecha has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
Hao S. Lo
Department of Radiology, University of Massachusetts School of Medicine, UMass Memorial Medical Center, 55 Lake Avenue North, Worcester, MA, 01655, USA
2 shared publications- Tina Shiang
Department of Radiology, Division of Musculoskeletal Imaging and Intervention, Massachusetts General Hospital, Harvard Medical School, Boston, MA, 02214, USA.
2 shared publications - Aly Abayazeed
University of Massachusetts Medical School, 12262, Radiology, Worcester, Massachusetts, United States;
1 shared publication Byron Y. Chen
Department of Radiology, University of Massachusetts Medical School, Worcester, MA
1 shared publicationCarolyn S. Dupuis
Department of Radiology, University of Massachusetts Medical School, Worcester, MA
1 shared publication- Christopher A. Cerniglia
Department of Radiology, University of Massachusetts School of Medicine, UMass Memorial Medical Center, 55 Lake Avenue North, Worcester, MA, 01655, USA
1 shared publication
Latest Publications
- Open Access
- 6 September 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (17) , 2862
Feasibility of AI-Denoised Ultra-Low-Dose CT for Detection of Acute Pelvic and Hip Fractures: A Pilot Multi-Reader Study
Objective: To evaluate the feasibility of simulated ultra-low-dose CT (ULD-CT) enhanced with deep learning denoising (DLD) for detecting pelvic and hip fractures. Method: This Institutional Review Board-approved retrospective study was performed at a multisite, single academic institution between October 2020 and May 2021, including 30 full-dose CT (CTfull) exams of acute pelvic and hip trauma (10 normal, 10 “easy,” 10 “hard” cases by fracture conspicuity). Simulated low-dose CT images at 10% (CT10sim) and 5% (CT5sim) radiation dose were generated using a noise model-based algorithm and reconstructed from full-dose CT datasets. A commercial deep learning denoising algorithm enhanced these images, resulting in denoised low-dose CTs (CT10dld and CT5dld) for evaluation. The 90 resulting CT cases were reviewed independently for diagnostic accuracy, confidence, sufficiency, and imaging quality. Result: Diagnostic accuracy was similar across CT modalities overall (CTfull 80.8% [72.9, 86.9]; CT10dld 78.3% [70.1, 84.8]; CT5dld 77.5% [69.2, 84.1]) and within the easy and normal strata; in hard cases, accuracy was numerically lower for CT10dld (45.0%) and CT5dld (42.5%) than for CTfull (57.5%). Diagnostic sufficiency was similarly high across modalities (CTfull 91.7%, CT10dld 87.5%, CT5dld 88.3%). CT full was rated highest in perceived image quality across all strata (mean 4.21 ± 0.83 overall vs. 3.47 ± 0.97 for CT10dld and 3.23 ± 0.98 for CT5dld) and in diagnostic confidence (mean 4.61 ± 0.63 vs. 4.45 ± 0.71 and 4.41 ± 0.72, respectively), though neither translated into a corresponding drop in diagnostic accuracy overall. Inter-reader agreement was highest between MSK radiologists, reaching substantial agreement on CT10dld (κ = 0.760) and CT5dld (κ = 0.672). Conclusions: DLD-enhanced ULD-CT showed diagnostic accuracy and sufficiency similar to full-dose CT for pelvic and hip fracture detection, at a fraction of the radiation dose, though full-dose CT was rated higher in perceived image quality and diagnostic confidence and outperformed denoised low-dose CT numerically in hard cases. Full-dose CT remains the preferred modality for complex and high-energy trauma, while denoised low-dose CT modalities represent a promising option for straightforward presentations where radiation minimization is a priority.
- 6 September 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (17) , 2862
Open AccessFeasibility of AI-Denoised Ultra-Low-Dose CT for Detection of Acute Pelvic and Hip Fractures: A Pilot Multi-Reader Study
Objective: To evaluate the feasibility of simulated ultra-low-dose CT (ULD-CT) enhanced with deep learning denoising (DLD) for detecting pelvic and hip fractures. Method: This Institutional Review Board-approved retrospective study was performed at a multisite, single academic institution between October 2020 and May 2021, including 30 full-dose CT (CTfull) exams of acute pelvic and hip trauma (10 normal, 10 “easy,” 10 “hard” cases by fracture conspicuity). Simulated low-dose CT images at 10% (CT10sim) and 5% (CT5sim) radiation dose were generated using a noise model-based algorithm and reconstructed from full-dose CT datasets. A commercial deep learning denoising algorithm enhanced these images, resulting in denoised low-dose CTs (CT10dld and CT5dld) for evaluation. The 90 resulting CT cases were reviewed independently for diagnostic accuracy, confidence, sufficiency, and imaging quality. Result: Diagnostic accuracy was similar across CT modalities overall (CTfull 80.8% [72.9, 86.9]; CT10dld 78.3% [70.1, 84.8]; CT5dld 77.5% [69.2, 84.1]) and within the easy and normal strata; in hard cases, accuracy was numerically lower for CT10dld (45.0%) and CT5dld (42.5%) than for CTfull (57.5%). Diagnostic sufficiency was similarly high across modalities (CTfull 91.7%, CT10dld 87.5%, CT5dld 88.3%). CT full was rated highest in perceived image quality across all strata (mean 4.21 ± 0.83 overall vs. 3.47 ± 0.97 for CT10dld and 3.23 ± 0.98 for CT5dld) and in diagnostic confidence (mean 4.61 ± 0.63 vs. 4.45 ± 0.71 and 4.41 ± 0.72, respectively), though neither translated into a corresponding drop in diagnostic accuracy overall. Inter-reader agreement was highest between MSK radiologists, reaching substantial agreement on CT10dld (κ = 0.760) and CT5dld (κ = 0.672). Conclusions: DLD-enhanced ULD-CT showed diagnostic accuracy and sufficiency similar to full-dose CT for pelvic and hip fracture detection, at a fraction of the radiation dose, though full-dose CT was rated higher in perceived image quality and diagnostic confidence and outperformed denoised low-dose CT numerically in hard cases. Full-dose CT remains the preferred modality for complex and high-energy trauma, while denoised low-dose CT modalities represent a promising option for straightforward presentations where radiation minimization is a priority.
- 11 February 2020
- Published by Springer Nature in Emergency Radiology
- Vol. 27 (4) , 451-453
CT diagnosis of bucket handle meniscus tear
Bucket handle meniscus tears are difficult to diagnosis and are one of the most frequently missed tear patterns on magnetic resonance imaging (MR). However, this meniscal injury often requires arthroscopic intervention and preoperative characterization of the tear is important to orthopedic surgeons for treatment planning. MR is currently the best imaging modality for evaluating meniscal tears, but trauma patients in the emergency room more often undergo radiographs and further evaluation with computed tomography (CT) exams. To date, there is one study from 1988 that reported the value of CT in diagnosing bucket handle meniscus tears. We present an informative case of bucket handle meniscus tear after acute traumatic knee injury that was diagnosed on CT and later confirmed on arthroscopy.
- 11 February 2020
- Published by Springer Nature in Emergency Radiology
- Vol. 27 (4) , 451-453
CT diagnosis of bucket handle meniscus tear
Bucket handle meniscus tears are difficult to diagnosis and are one of the most frequently missed tear patterns on magnetic resonance imaging (MR). However, this meniscal injury often requires arthroscopic intervention and preoperative characterization of the tear is important to orthopedic surgeons for treatment planning. MR is currently the best imaging modality for evaluating meniscal tears, but trauma patients in the emergency room more often undergo radiographs and further evaluation with computed tomography (CT) exams. To date, there is one study from 1988 that reported the value of CT in diagnosing bucket handle meniscus tears. We present an informative case of bucket handle meniscus tear after acute traumatic knee injury that was diagnosed on CT and later confirmed on arthroscopy.
- 28 August 2019
- Published by Springer Nature in Emergency Radiology
- Vol. 27 (1) , 9-16
Abbreviated MRI of the foot in patients with suspected osteomyelitis
To determine the diagnostic accuracy of an abbreviated magnetic resonance imaging (MRI) protocol of the foot for the diagnosis of osteomyelitis in patients with acute foot infection.
- 28 August 2019
- Published by Springer Nature in Emergency Radiology
- Vol. 27 (1) , 9-16
Abbreviated MRI of the foot in patients with suspected osteomyelitis
To determine the diagnostic accuracy of an abbreviated magnetic resonance imaging (MRI) protocol of the foot for the diagnosis of osteomyelitis in patients with acute foot infection.
- 1 August 2018
- Published by Elsevier in Seminars in Ultrasound, CT and MRI
- Vol. 39 (4) , 324-335
Imaging of Spine Fractures With Emphasis on the Craniocervical Junction
- 1 August 2018
- Published by Elsevier in Seminars in Ultrasound, CT and MRI
- Vol. 39 (4) , 324-335
Imaging of Spine Fractures With Emphasis on the Craniocervical Junction
- 1 November 2017
- Published by Elsevier in Current Problems in Diagnostic Radiology
- Vol. 46 (6) , 423-431
What to Expect When They are Expecting: Magnetic Resonance Imaging of the Acute Abdomen and Pelvis in Pregnancy
- 1 November 2017
- Published by Elsevier in Current Problems in Diagnostic Radiology
- Vol. 46 (6) , 423-431
What to Expect When They are Expecting: Magnetic Resonance Imaging of the Acute Abdomen and Pelvis in Pregnancy