JMJessica A. Martinez

Jessica A. Martinez

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jessica A. Martinez has a total of 44 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Imaging cell phone radiation in tissue mimics with hyperpolarized low-field MRI

    by Stephen E. Ogier, Stephen E. Russek, Jessica A. Martinez, Kaitlyn M. Betz, Karl F. Stupic, William J. Watterson, Matthew T. Simons, Christopher L. Holloway, Joshua R. Biller, Deepansh J. Srivastava, et al.

    Radiation from cell phones and cellular devices is ubiquitous and, in the microwave frequency bands used, human tissue is a highly absorbing complex electromagnetic material. Safety guidelines are currently based on heating and specific absorption rate using limited measurement and modeling techniques. Here, we present a method to image microwave electromagnetic fields from cellular device radiation in tissue mimics using hyperpolarized low-field magnetic resonance imaging (MRI). Resonant absorption of microwave radiation in free radicals added to the tissue mimics, transfers polarization to the water proton system and, at cell phone power levels, can not only be detected, but can increase the signal over the native low-field MRI signal. Electromagnetic field imaging can be done before substantial heating of the material. Imaging and quantification provide a better understanding of how cellular radiation penetrates and is absorbed in complex materials, such as tissues, and may allow validation of numerical models. We further demonstrate the use of this technique to image microwave field distortion and reradiation around implants and foreign objects, including from a millimeter-sized biopsy marker. We present initial steps at quantifying the hyperpolarized low-field images to allow extraction of electromagnetic field values. The concurrent use of quantitative MRI allows critical tissue parameters to be monitored before, during, and after microwave exposure.

  • Open Access

    Construction of Phantoms for MR Electrical Properties Tomography (From Structure to Composition): A Guideline From the ISMRM Electro‐Magnetic Tissue Properties Study Group

    by Ilias I. Giannakopoulos, Alessandro Arduino, Cornelis A. T. van Den Berg, Zhongzheng He, Kyu‐Jin Jung, Dong‐Hyun Kim, Riccardo Lattanzi, Jessica A. Martinez, Thierry Meerbothe, Freddy Odille, et al.


  • Open Access

    Feasibility study of subject‐specific, brain specific‐absorption‐rate maps retrieved from MRI data

    by Jessica A. Martinez, Umberto Zanovello, Alessandro Arduino, Houchun Harry Hu, Kevin Moulin, Stephen E. Ogier, Oriano Bottauscio, Luca Zilberti, Kathryn E. Keenan

    Introduction: Specific absorption rate (SAR) is crucial for monitoring radiofrequency power absorption during MRI. Although local SAR distribution is usually calculated through numerical simulations, they are impractical during exams, limiting real‐time patient‐specific SAR assessment. This study confirms the feasibility of deriving in vivo, subject‐specific, image‐based SAR and 10‐g SAR maps directly from MRI data.Methods: Complex B1+ maps were derived by combining a B1+ product (XFL) magnitude sequence with balanced steady‐state free precession phase. Anatomical information and tissue masking were obtained from a T1 magnetization‐prepared rapid gradient echo sequence. Electrical conductivity maps were generated from balanced steady‐state free precession phase. Whole‐brain SAR maps were created from MRI data acquired at 3 T using a 32‐channel head coil on 2 healthy volunteers. A correction factor was applied to account for underestimation due to reliance on measurable B1+ data. Numerical simulations compared image‐based SAR with simulation‐based SAR distributions.Results: A multi‐slice image‐based brain SAR map was obtained in 12 min (9‐min acquisition, 3‐min SAR reconstruction). In vitro experiments validated B1+ distribution and electrical conductivity values. Calculated electrical conductivities for in vitro and in vivo experiments were within reference ranges. Image‐based SAR and 10‐g SAR maps showed a distribution similar to simulation‐based maps (r = 0.5) after correction.Conclusions: This study shows the feasibility of inline, subject‐specific SAR and 10‐g SAR maps from standard brain clinical sequences. Image‐based SAR maps can be a practical alternative during MRI exams when simulations are not feasible.


  • Open Access

    Magnetic Resonance-Based Electric Properties Tomography via Green’s Integral Identity

    by Luca Zilberti, Alessandro Arduino, Umberto Zanovello, Jessica A. Martinez, Kevin Moulin, Adriano Troia, Oriano Bottauscio

    A new approach to Magnetic Resonance-based Electric Properties Tomography (EPT) is presented. The method applies Green’s integral identity to the equation that regulates the EPT problem. The resultant integral equations are used to impose the consistency of the measured values of the radiofrequency field. This is achieved by seeking dielectric properties values that allow satisfying the identity within suitable kernels of voxels. In each kernel, an overdetermined system of equations is written, and the corresponding problem is solved in the least squares sense, providing an index of trustworthiness of the solution. Both the complete formulation and its phase-based approximation are presented. The application of a filter, which post-processes the raw results based on the index of trustworthiness, is also discussed. The performance of the method is evaluated on synthetic data and experimental measurements acquired on a heterogeneous brain phantom and on four human volunteers. The reconstructions are compared to those produced through a Helmholtz-EPT with adaptive kernel. The new EPT method performs well in all tests.


  • Open Access

    Phase-sensitive deep reconstruction method for rapid multiparametric MR fingerprinting and quantitative susceptibility mapping in the brain

    by Jessica A. Martinez, Victoria Y. Yu, Kathryn R. Tringale, Ricardo Otazo, Ouri Cohen


  • Open Access

    Evaluation and Correction of $B_{1}^+$-Based Brain Subject-Specific SAR Maps Using Electrical Properties Tomography

    by Jessica A. Martinez, Alessandro Arduino, Oriano Bottauscio, Luca Zilberti

    The specific absorption rate (SAR) estimates the amount of power absorbed by the tissue and is determined by the electrical conductivity and the E-field. Conductivity can be estimated using Electric Properties Tomography (EPT) but only the E-field component associated with $B_{1}^+$ can be deduced from $B_{1}$ -mapping. Herein, a correction factor was calculated to compensate for the differences between the actual SAR and the one obtained with $B_{1}^+$ . Numerical simulations were performed for 27 head models at $128 \,\mathrm{M}\mathrm{Hz}$ . Ground-truth local-SAR and 10g-SAR (SAR GT ) were computed using the exact electrical conductivity and the E-field. Estimated local-SAR and 10g-SAR (SAR EST ) were computed using the electrical conductivity obtained with a convection-reaction EPT and the E-field obtained from $B_{1}^+$ . Correction factors (CFs) were estimated for gray matter, white matter, and cerebrospinal fluid (CSF). A comparison was performed for different levels of signal-to-noise ratios (SNR). Local-SAR/10g-SAR CF was 3.08 $\pm$ 0/06 / 2.11 $\pm$ 0.04 for gray matter, 1.79 $\pm$ 0/05 / 2.06 $\pm$ 0.04 for white matter, and 2.59 $\pm$ 0/05 / 1.95 $\pm$ 0.03 for CSF. SAR EST without CF were underestimated (ratio across [ $\infty$ - 25] SNRs: 0.52 $\pm$ 0.02 for local-SAR; 0.55 $\pm$ 0.01 for 10g-SAR). After correction, SAR EST was equivalent to SAR GT (ratio across [ $\infty$ - 25] SNRs: 0.97 $\pm$ 0.02 for local-SAR; 1.06 $\pm$ 0.01 for 10g-SAR). SAR maps based on $B_{1}^+$ can be corrected with a correction factor to compensate for potential differences between the actual SAR and the SAR calculated with the E-field derived from $B_{1}^+$ .


  • Open Access

    Computational dosimetry in MRI in presence of hip, knee or shoulder implants: do we need accurate surgery models?

    by Alessandro Arduino, Fabio Baruffaldi, Oriano Bottauscio, Mario Chiampi, Jessica A Martinez, Umberto Zanovello, Luca Zilberti

    Objective. To quantify the effects of different levels of realism in the description of the anatomy around hip, knee or shoulder implants when simulating, numerically, radiofrequency and gradient-induced heating in magnetic resonance imaging. This quantification is needed to define how precise the digital human model modified with the implant should be to get realistic dosimetric assessments. Approach . The analysis is based on a large number of numerical simulations where four ‘levels of realism’ have been adopted in modelling human bodies carrying orthopaedic implants. Main results . Results show that the quantification of the heating due to switched gradient fields does not strictly require a detailed local anatomical description when preparing the digital human model carrying an implant. In this case, a simple overlapping of the implant CAD with the body anatomy is sufficient to provide a quite good and conservative estimation of the heating. On the contrary, the evaluation of the electromagnetic field distribution and heating caused by the radiofrequency field requires an accurate description of the tissues around the prosthesis. Significance . The results of this paper provide hints for selecting the ‘level of realism’ in the definition of the anatomical models with embedded passive implants when performing simulations that should reproduce, as closely as possible, the in vivo scenarios of patients carrying orthopaedic implants.


  • Evaluation of Patient Positioning to Mitigate RF-induced Heating of Cardiac Implantable Electronic Devices for Pediatric MRI Exams

    by Jessica A. Martinez, Tyler E. Cork, Henry Chubb, Shreyas Vasanawala, Daniel B. Ennis

    Pediatric patients with cardiac implantable electronic devices (CIEDs) are generally contraindicated for MRI exams. Previous work in the adult population suggests that RF-induced lead-tip heating strongly depends on the patient’s position and orientation within the MRI scanner. The objective of this work was to evaluate the local Specific Absorption Rate (local-SAR) in silico for several pediatric patient positions within the MRI scanner as a method to potentially mitigate RF-heating lead-tip heating of CIEDs.


  • Evaluation of a Workflow to Define Low Specific Absorption Rate MRI Protocols for Patients With Active Implantable Medical Devices

    by Jessica A. Martinez, Kévin Moulin, Bryan Yoo, Yu Shi, Hyun J. Kim, Pablo J. Villablanca, Daniel B. Ennis

    Background: MRI exams for patients with MR‐conditional active implantable medical devices (AIMDs) are contraindicated unless specific conditions are met. This limits the maximum specific absorption rate (SAR, W/kg). Currently, there is no general framework to guide meeting a lower SAR limit.Purpose: To design and evaluate a workflow for modifying MRI protocols to whole‐body SAR (WB‐SAR ≤0.1 W/kg) and local‐head SAR (LH‐SAR ≤0.3 W/kg) limits while mitigating the impact on image quality and exam time.Study Type: Prospective.Population: Twenty healthy volunteers on head (n = 5), C‐spine (n = 5), T‐spine (n = 5), and L‐spine (n = 5) with IRB consent.Assessment: Vendor‐provided head, C‐spine, T‐spine, and L‐spine protocols (SARRT) were modified to meet both low SAR targets (SARLOW) using the proposed workflow. in vitro SNR and CNR were evaluated with a T1‐T2 phantom. in vivo image quality and clinical acceptability were scored using a 5‐point Likert scale for two blinded readers.Field Strength/Sequences: 1.5T/spin‐echoes, gradient‐echoes.Statistical Analysis: In vitro SNR and CNR values were evaluated with a repeated measures general linear model. in vivo image quality and clinical acceptability were evaluated using a generalized estimating equation analysis (GEE). The two reader's level of agreement was analyzed using Cohen's kappa statistical analysis.Results: Using the workflow, SAR limits were met. LH‐SAR: 0.12 ± 0.02 W/kg, median (SD) values for LH‐SAR were 0.12 (0.02) W/kg and WB‐SAR: 0.09 (0.01) W/kg. Examination time did not increase ≤2x the initial time. SARRT SNR values were higher and significantly different than SARLOW (P < 0.05). However, no significant difference was observed between the CNR values (value = 0.21). Median (IQR) CNR values were 14.2 (25.0) vs. 15.1 (9.2) for head, 12.1 (16.9) vs. 25.3 (14.2) for C‐spine, 81.6 (70.1) vs. 71.0 (26.6) for T‐spine, and 51.4 (52.6) vs. 37.7 (27.3) for L‐spine. Image quality scores were not significantly different between SARRT and SARLOW (median [SD] scores were 4.0 [0.01] vs. 4.3 [0.2], P > 0.05).Data Conclusion: The proposed workflow provides guidance for modifying routine MRI exams to achieve low SAR limits. This can benefit patients referred for an MRI exam with low SAR MR‐conditional AIMDs.Level of Evidence: 1Technical Efficacy Stage: 5J. Magn. Reson. Imaging 2020;52:91–102.


  • Patient Orientation Affects Lead-Tip Heating of Cardiac Active Implantable Medical Devices during MRI

    by Jessica A. Martinez, Peter Serano, Daniel B. Ennis

    Radiofrequency-induced lead tip heating for left-sided cardiac devices can be reduced by changing from a supine head-first to a supine feet-first patient orientation. Purpose To evaluate changes in patient orientation to mitigate radiofrequency-induced lead-tip heating (LTH) during MRI. Materials and Methods LTH was evaluated for device type, lead path, and dist...