TATimothy K. Amukele

Timothy K. Amukele

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Timothy K. Amukele has a total of 26 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    The economics of medical drones

    by Timothy Amukele


  • Open Access

    Test Cost and Test Accuracy in Clinical Laboratories in Kampala, Uganda

    by Timothy K Amukele, Robert Jones, Ali Elbireer

    To assess the accuracy and costs of laboratory tests in Kampala, Uganda. A random selection of 78 laboratories tested external quality assurance samples at market rates. There were 40 moderate- to high-complexity and 38 low-complexity laboratories. Four percent (3/78) of these laboratories were accredited and 94% (73/78) were private. The 40 moderate- to high-complexity laboratories performed malaria blood smear, urine human chorionic gonadotropin (hCG), human immunodeficiency virus (HIV), syphilis, glucose, and three-panel tests: CBC, liver function tests, and kidney function tests. The 38 low-complexity laboratories performed malaria blood smear, urine hCG, and syphilis testing only. Hematology, HIV, syphilis, and malarial proficiency testing samples were prepared by accredited laboratories in Kampala. All other samples were provided by the Royal College of Pathologists of Australia. 77.1% of all results were accurate (met target values). It varied widely by laboratory (50%-100%), test identity (malaria blood smear, 96%; serum urea nitrogen, 38%), and test type (quantitative: 66% [31%-89%], qualitative: 91% [68%-97%]). Test prices varied by up to 3,600%, and there was no correlation between test cost and accuracy (r2 = 0.02). There were large differences in accuracy and price across laboratories in Kampala. Price was not associated with quality.


  • Open Access

    Drone Transport of Chemistry and Hematology Samples Over Long Distances

    by Timothy K Amukele, James Hernandez, Christine Lh Snozek, Ryan G Wyatt, Matthew Douglas, Richard Amini, Jeff Street

    We addressed the stability of biological samples in prolonged drone flights by obtaining paired chemistry and hematology samples from 21 adult volunteers in a single phlebotomy event—84 samples total. Half of the samples were held stationary, while the other samples were flown for 3 hours (258 km) in a custom active cooling box mounted on the drone. After the flight, 19 chemistry and hematology tests were performed. Seventeen analytes had small or no bias, but glucose and potassium in flown samples showed an 8% and 6.2% bias, respectively. The flown samples (mean, 24.8°C) were a mean of 2.5°C cooler than the stationary samples (mean, 27.3°C) during transportation to the flight field as well as during the flight. The changes in glucose and potassium are consistent with the magnitude and duration of the temperature difference between the flown and stationary samples. Long drone flights of biological samples are feasible but require stringent environmental controls to ensure consistent results.


  • What Is the Value of Clinical Laboratory Testing?

    by Timothy Amukele, Lee Schroeder

    The most common answer to the title question in laboratory medicine circles is, “laboratory tests are the basis of 70% of medical decisions.” Although this is a nice soundbite, it is an unsubstantiated claim and has little scientific basis. However, the 70% number has been propagated because it is both compelling and easy to remember. Ngo et al. (1) in their article in this issue, “Frequency that laboratory tests influence medical decisions,” show that the truth is far more complicated and depends on the clinical setting. They found that the average percentage of encounters that had at least 1 associated laboratory test was 35%, with 98% in inpatients and 29% in outpatients. Other settings, such as the …


  • Top Cited Papers

    Drone transportation of blood products

    by Timothy Amukele, Paul M. Ness, Aaron A.R. Tobian, Joan Boyd, Jeff Street

    BACKGROUND: Small civilian unmanned aerial vehicles (drones) are a novel way to transport small goods. To the best of our knowledge there are no studies examining the impact of drone transport on blood products, describing approaches to maintaining temperature control, or component physical characteristics during drone transport.STUDY DESIGN AND METHODS: Six leukoreduced red blood cell (RBC) and six apheresis platelet (PLT) units were split using sterile techniques. The larger parent RBC and PLT units, as well as six unthawed plasma units frozen within 24 hours of collection (FP24), were placed in a cooler, attached to the drone, and flown for up to 26.5 minutes with temperature logging. Ambient temperatures during the experimental window ranged between −1 and 18°C across 2 days. The difference between the ambient and unit temperatures was approximately 20°C for PLT and FP24 units. After flight, the RBC parent units were centrifuged and visually checked for hemolysis; the PLTs were checked for changes in mean PLT volumes (MPVs), pH, and PLT count; and the frozen air bubbles on the back of the FP24 units were examined for any changes in size or shape, as evidence of thawing.RESULTS: There was no evidence of RBC hemolysis; no significant changes in PLT count, pH, or MPVs; and no changes in the FP24 bubbles. The temperature of all units was maintained during transport and flight.CONCLUSION: There was no adverse impact of drone transport on RBC, PLT, or FP24 units. These findings suggest that drone transportation systems are a viable option for the transportation of blood products.


  • Open Access

    Can Unmanned Aerial Systems (Drones) Be Used for the Routine Transport of Chemistry, Hematology, and Coagulation Laboratory Specimens?

    by Timothy K Amukele, Lori J Sokoll, Daniel Pepper, Dana P Howard, Jeff Street

    Unmanned Aerial Systems (UAS or drones) could potentially be used for the routine transport of small goods such as diagnostic clinical laboratory specimens. To the best of our knowledge, there is no published study of the impact of UAS transportation on laboratory tests. Three paired samples were obtained from each one of 56 adult volunteers in a single phlebotomy event (336 samples total): two tubes each for chemistry, hematology, and coagulation testing respectively. 168 samples were driven to the flight field and held stationary. The other 168 samples were flown in the UAS for a range of times, from 6 to 38 minutes. After the flight, 33 of the most common chemistry, hematology, and coagulation tests were performed. Statistical methods as well as performance criteria from four distinct clinical, academic, and regulatory bodies were used to evaluate the results. Results from flown and stationary sample pairs were similar for all 33 analytes. Bias and intercepts were <10% and <13% respectively for all analytes. Bland-Altman comparisons showed a mean difference of 3.2% for Glucose and <1% for other analytes. Only bicarbonate did not meet the strictest (Royal College of Pathologists of Australasia Quality Assurance Program) performance criteria. This was due to poor precision rather than bias. There were no systematic differences between laboratory-derived (analytic) CV’s and the CV’s of our flown versus terrestrial sample pairs however CV’s from the sample pairs tended to be slightly higher than analytic CV’s. The overall concordance, based on clinical stratification (normal versus abnormal), was 97%. Length of flight had no impact on the results. Transportation of laboratory specimens via small UASs does not affect the accuracy of routine chemistry, hematology, and coagulation tests results from selfsame samples. However it results in slightly poorer precision for some analytes.


  • Open Access

    Most Clinical Laboratory Testing in Kampala Occurs in High-Volume, High-Quality Laboratories or Low-Volume, Low-Quality Laboratories

    by Timothy K. Amukele, Lee F. Schroeder, J. Brooks Jackson, Ali Elbireer

    Objectives:. To describe key characteristics (laboratory quality, test volumes, and complexity) of clinical laboratories in Kampala, Uganda (population


  • Vitamin D levels in Malawian infants from birth to 24 months

    by Timothy K Amukele, Dean Soko, Pauline Katundu, Melvin Kamanga, Jin Sun, N. I. Kumwenda, T. E. Taha

    We measured longitudinal levels of vitamin D in unsupplemented Malawian infants at 0 (birth), 2, 12, 15, 18 and 24 months of age. Matched maternal plasma and breast milk vitamin D2 and D3 levels were also measured at delivery and 2 months postpartum. Vitamin D was measured using isotope-dilution liquid chromatography tandem-mass spectrometry. Vitamin D3 levels in children were 36% of adult levels at birth, 60% of adult levels at age 2 months, and at par with adult levels by 12 months of age. This adult-equivalent level is subsequently maintained through age 24 months and consisted of a 98% molar ratio of vitamin D3. Vitamin D levels in breast milk were below the limit of detection, 0.1 ng/ml. Breast milk of unsupplemented Malawian mothers is a poor source of vitamin D.


  • Open Access

    External Quality Assurance Performance of Clinical Research Laboratories in Sub-Saharan Africa

    by Timothy K. Amukele, Kurt Michael, Mary Hanes, Robert E. Miller, J. Brooks Jackson

    Patient Safety Monitoring in International Laboratories (JHU-SMILE) is a resource at Johns Hopkins University that supports and monitors laboratories