Alexander K. Nguyen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Alexander K. Nguyen has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
- Roger Jagdish Narayan
Joint Department of Biomedical Engineering North Carolina State University Raleigh North Carolina USA
8 shared publications - Peter L. Goering
Office of Science and Engineering Laboratories, Center for Devices and Radiological Health U.S. Food and Drug Administration Silver Spring Maryland USA
3 shared publications Girish Kumar
Office of Product Evaluation and Quality, Center for Devices and Radiological Health U.S. Food and Drug Administration Silver Spring Maryland USA
2 shared publicationsPeter L. Goering
Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, MD
2 shared publicationsRoger J. Narayan
Joint Department of Biomedical Engineering UNC/NCSU Raleigh North Carolina USA
2 shared publications- Anastasia Koroleva
Laser Zentrum Hannover e.V.
1 shared publication
Latest Publications
- 29 November 2022
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 111 (5) , 987-995
Effect of simulated body fluid formulation on orthopedic device apatite‐forming ability assessment
Integration of native bone into orthopedic devices is a key factor in long‐term implant success. The material‐tissue interface is generally accepted to consist of a hydroxyapatite layer so bioactive materials that can spontaneously generate this hydroxyapatite layer after implantation may improve patient outcomes. Per the ISO 22317:2014 standard, “Implants for surgery – In vitro evaluation for apatite‐forming ability of implant materials,” bioactivity performance statements can be assessed by soaking the material in simulated body fluid (SBF) and evaluating the surface for the formation of a hydroxyapatite layer; however, variations in test methods may alter hydroxyapatite formation and result in false‐positive assessments. The goal of this study was to identify the effect of SBF formulation on bioactivity assessment. Bioglass® (45S5 and S53P4) and non‐bioactive Ti‐6Al‐4V were exposed to SBF formulations varying in calcium ion and phosphate concentrations as well as supporting ion concentrations. Scanning electron microscopy and X‐ray powder diffraction evaluation of the resulting hydroxyapatite layers revealed that SBF enriched with double or quadruple the calcium and phosphate ion concentrations increased hydroxyapatite crystal size and quantity compared to the standard formulation and can induce hydroxyapatite crystallization on surfaces traditionally considered non‐bioactive. Altering concentrations of other ions, for example, bicarbonate, changed hydroxyapatite induction time, quantity, and morphology. For studies evaluating the apatite‐forming ability of a material to support bioactivity performance statements, test method parameters must be adequately described and controlled. It is unclear if apatite formation after exposure to any of the SBF formulations is representative of an in vivo biological response. The ISO 23317 standard test method should be further developed to provide additional guidance on apatite characterization and interpretation of the results.
- 29 November 2022
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 111 (5) , 987-995
Effect of simulated body fluid formulation on orthopedic device apatite‐forming ability assessment
Integration of native bone into orthopedic devices is a key factor in long‐term implant success. The material‐tissue interface is generally accepted to consist of a hydroxyapatite layer so bioactive materials that can spontaneously generate this hydroxyapatite layer after implantation may improve patient outcomes. Per the ISO 22317:2014 standard, “Implants for surgery – In vitro evaluation for apatite‐forming ability of implant materials,” bioactivity performance statements can be assessed by soaking the material in simulated body fluid (SBF) and evaluating the surface for the formation of a hydroxyapatite layer; however, variations in test methods may alter hydroxyapatite formation and result in false‐positive assessments. The goal of this study was to identify the effect of SBF formulation on bioactivity assessment. Bioglass® (45S5 and S53P4) and non‐bioactive Ti‐6Al‐4V were exposed to SBF formulations varying in calcium ion and phosphate concentrations as well as supporting ion concentrations. Scanning electron microscopy and X‐ray powder diffraction evaluation of the resulting hydroxyapatite layers revealed that SBF enriched with double or quadruple the calcium and phosphate ion concentrations increased hydroxyapatite crystal size and quantity compared to the standard formulation and can induce hydroxyapatite crystallization on surfaces traditionally considered non‐bioactive. Altering concentrations of other ions, for example, bicarbonate, changed hydroxyapatite induction time, quantity, and morphology. For studies evaluating the apatite‐forming ability of a material to support bioactivity performance statements, test method parameters must be adequately described and controlled. It is unclear if apatite formation after exposure to any of the SBF formulations is representative of an in vivo biological response. The ISO 23317 standard test method should be further developed to provide additional guidance on apatite characterization and interpretation of the results.
- Open Access
- 26 July 2022
- Published by MDPI AG in Pharmaceutics
- Vol. 14 (8) , 1551
Micromolding of Amphotericin-B-Loaded Methoxyethylene–Maleic Anhydride Copolymer Microneedles
Biocompatible and biodegradable materials have been used for fabricating polymeric microneedles to deliver therapeutic drug molecules through the skin. Microneedles have advantages over other drug delivery methods, such as low manufacturing cost, controlled drug release, and the reduction or absence of pain. The study examined the delivery of amphotericin B, an antifungal agent, using microneedles that were fabricated using a micromolding technique. The microneedle matrix was made from GantrezTM AN-119 BF, a benzene-free methyl vinyl ether/maleic anhydride copolymer. The GantrezTM AN-119 BF was mixed with water; after water evaporation, the polymer exhibited sufficient strength for microneedle fabrication. Molds cured at room temperature remained sharp and straight. SEM images showed straight and sharp needle tips; a confocal microscope was used to determine the height and tip diameter for the microneedles. Nanoindentation was used to obtain the hardness and Young’s modulus values of the polymer. Load–displacement testing was used to assess the failure force of the needles under compressive loading. These two mechanical tests confirmed the mechanical properties of the needles. In vitro studies validated the presence of amphotericin B in the needles and the antifungal properties of the needles. Amphotericin B GantrezTM microneedles fabricated in this study showed appropriate characteristics for clinical translation in terms of mechanical properties, sharpness, and antifungal properties.
- 26 July 2022
- Published by MDPI AG in Pharmaceutics
- Vol. 14 (8) , 1551
Open AccessMicromolding of Amphotericin-B-Loaded Methoxyethylene–Maleic Anhydride Copolymer Microneedles
Biocompatible and biodegradable materials have been used for fabricating polymeric microneedles to deliver therapeutic drug molecules through the skin. Microneedles have advantages over other drug delivery methods, such as low manufacturing cost, controlled drug release, and the reduction or absence of pain. The study examined the delivery of amphotericin B, an antifungal agent, using microneedles that were fabricated using a micromolding technique. The microneedle matrix was made from GantrezTM AN-119 BF, a benzene-free methyl vinyl ether/maleic anhydride copolymer. The GantrezTM AN-119 BF was mixed with water; after water evaporation, the polymer exhibited sufficient strength for microneedle fabrication. Molds cured at room temperature remained sharp and straight. SEM images showed straight and sharp needle tips; a confocal microscope was used to determine the height and tip diameter for the microneedles. Nanoindentation was used to obtain the hardness and Young’s modulus values of the polymer. Load–displacement testing was used to assess the failure force of the needles under compressive loading. These two mechanical tests confirmed the mechanical properties of the needles. In vitro studies validated the presence of amphotericin B in the needles and the antifungal properties of the needles. Amphotericin B GantrezTM microneedles fabricated in this study showed appropriate characteristics for clinical translation in terms of mechanical properties, sharpness, and antifungal properties.
- Open Access
- 21 July 2021
- Published by Wiley in Journal of the American Ceramic Society
- Vol. 105 (3) , 1821-1840
Direct ink writing of vancomycin‐loaded polycaprolactone/ polyethylene oxide/ hydroxyapatite 3D scaffolds
Novel inks were formulated by dissolving polycaprolactone (PCL), a hydrophobic polymer, in organic solvent systems; polyethylene oxide (PEO) was incorporated to extend the range of hydrophilicity of the system. Hydroxyapatite (HAp) with a weight ratio of 55–85% was added to the polymer‐based solution to mimic the material composition of natural bone tissue. The direct ink writing (DIW) technique was applied to extrude the formulated inks to fabricate the predesigned tissue scaffold structures; the influence of HAp concentration was investigated. The results indicate that in comparison to other inks containing HAp (55%, 75%, and 85%w/w), the ink containing 65% w/w HAp had faster ink recovery behavior; the fabricated scaffold had a rougher surface as well as better mechanical properties and wettability. It is noted that the 65% w/w HAp concentration is similar to the inorganic composition of natural bone tissue. The elastic modulus values of PCL/PEO/HAp scaffolds were in the range of 4–12 MPa; the values were dependent on the HAp concentration. Furthermore, vancomycin as a model drug was successfully encapsulated in the PCL/PEO/HAp composite scaffold for drug release applications. This paper presents novel drug‐loaded PCL/PEO/HAp inks for 3D scaffold fabrication using the DIW printing technique for potential bone scaffold applications.
- 21 July 2021
- Published by Wiley in Journal of the American Ceramic Society
- Vol. 105 (3) , 1821-1840
Open AccessDirect ink writing of vancomycin‐loaded polycaprolactone/ polyethylene oxide/ hydroxyapatite 3D scaffolds
Novel inks were formulated by dissolving polycaprolactone (PCL), a hydrophobic polymer, in organic solvent systems; polyethylene oxide (PEO) was incorporated to extend the range of hydrophilicity of the system. Hydroxyapatite (HAp) with a weight ratio of 55–85% was added to the polymer‐based solution to mimic the material composition of natural bone tissue. The direct ink writing (DIW) technique was applied to extrude the formulated inks to fabricate the predesigned tissue scaffold structures; the influence of HAp concentration was investigated. The results indicate that in comparison to other inks containing HAp (55%, 75%, and 85%w/w), the ink containing 65% w/w HAp had faster ink recovery behavior; the fabricated scaffold had a rougher surface as well as better mechanical properties and wettability. It is noted that the 65% w/w HAp concentration is similar to the inorganic composition of natural bone tissue. The elastic modulus values of PCL/PEO/HAp scaffolds were in the range of 4–12 MPa; the values were dependent on the HAp concentration. Furthermore, vancomycin as a model drug was successfully encapsulated in the PCL/PEO/HAp composite scaffold for drug release applications. This paper presents novel drug‐loaded PCL/PEO/HAp inks for 3D scaffold fabrication using the DIW printing technique for potential bone scaffold applications.
- 1 March 2021
- Published by AIP Publishing in Applied Physics Reviews
- Vol. 8 (1) , 011301
Biological function following radical photo-polymerization of biomedical polymers and surrounding tissues: Design considerations and cellular risk factors
Radical photo-cross-linking of polymers has been at the forefront in the development of biomedical applications to meet many of the biomaterial design criteria needed to address clinical and healthcare challenges, particularly in relation to regenerative and restorative medicine strategies, to treat damaged or diseased tissues and organs. Exciting new hybrid designs, elegantly expanding the range of properties and applications available to individual polymeric materials, are starting to offer detailed customization with complex and dynamic interactions similar to the events occurring within native tissue microenvironments in vivo. Yet the variety in success reported in the literature highlights the many unknown design criteria and parameters affecting functional restoration of damaged tissues and organs. The applied light curing units and radical initiating system, as well as underlying chemical reactions and resultant network structures, all require detailed consideration as means to modulate biological function while further being assessed as sources of toxicity. This is especially important when cells embedded in the polymeric material (or in surrounding tissues) are directly exposed to photo-irradiation. Ultimately, achieving successful clinical translation necessitates the chemical photo-polymerization platforms to be efficacious, safe, and customizable but also convenient for clinical use and cost-effective production. This review thus aims to summarize current and emerging toolkits to photo-polymerize biomedical polymers requiring the direct irradiation of cells and/or mammalian tissues and its associated impact on biological functionality. This specifically includes (1) in vitro photo-polymerization of cell-laden 3D-hydrogels for tissue engineering and regeneration medicine applications, (2) in vivo transdermal photo-polymerization of injectable hydrogels for cell/drug delivery, and (3) in vivo photo-polymerization of cell-free, injectable resin-based composites for load-bearing restorative surgery, all fast-growing and highly competitive fields of modern medicine. We herein summarize both design considerations and biological risk factors associated with selecting suitable light sources, photo-initiators, functional groups, chemical propagation, as well as how subsequent network properties can modulate biological function and ultimately clinical applicability. As more knowledge is continuously accumulated through materials science, matrix biology, and technology, this review provides recommendations for researchers to extend their chemical, biological, and structural characterizations to systematically enrich the paradigm of photo-polymerizable materials for biomedical applications to help ensure efficient and safe radical photo-processing.
- 1 March 2021
- Published by AIP Publishing in Applied Physics Reviews
- Vol. 8 (1) , 011301
Biological function following radical photo-polymerization of biomedical polymers and surrounding tissues: Design considerations and cellular risk factors
Radical photo-cross-linking of polymers has been at the forefront in the development of biomedical applications to meet many of the biomaterial design criteria needed to address clinical and healthcare challenges, particularly in relation to regenerative and restorative medicine strategies, to treat damaged or diseased tissues and organs. Exciting new hybrid designs, elegantly expanding the range of properties and applications available to individual polymeric materials, are starting to offer detailed customization with complex and dynamic interactions similar to the events occurring within native tissue microenvironments in vivo. Yet the variety in success reported in the literature highlights the many unknown design criteria and parameters affecting functional restoration of damaged tissues and organs. The applied light curing units and radical initiating system, as well as underlying chemical reactions and resultant network structures, all require detailed consideration as means to modulate biological function while further being assessed as sources of toxicity. This is especially important when cells embedded in the polymeric material (or in surrounding tissues) are directly exposed to photo-irradiation. Ultimately, achieving successful clinical translation necessitates the chemical photo-polymerization platforms to be efficacious, safe, and customizable but also convenient for clinical use and cost-effective production. This review thus aims to summarize current and emerging toolkits to photo-polymerize biomedical polymers requiring the direct irradiation of cells and/or mammalian tissues and its associated impact on biological functionality. This specifically includes (1) in vitro photo-polymerization of cell-laden 3D-hydrogels for tissue engineering and regeneration medicine applications, (2) in vivo transdermal photo-polymerization of injectable hydrogels for cell/drug delivery, and (3) in vivo photo-polymerization of cell-free, injectable resin-based composites for load-bearing restorative surgery, all fast-growing and highly competitive fields of modern medicine. We herein summarize both design considerations and biological risk factors associated with selecting suitable light sources, photo-initiators, functional groups, chemical propagation, as well as how subsequent network properties can modulate biological function and ultimately clinical applicability. As more knowledge is continuously accumulated through materials science, matrix biology, and technology, this review provides recommendations for researchers to extend their chemical, biological, and structural characterizations to systematically enrich the paradigm of photo-polymerizable materials for biomedical applications to help ensure efficient and safe radical photo-processing.
- 1 December 2020
- Published by Elsevier in Bioprinting
- Vol. 20
3D printing and bioprinting using multiphoton lithography
- 1 December 2020
- Published by Elsevier in Bioprinting
- Vol. 20
3D printing and bioprinting using multiphoton lithography
- 1 September 2020
- Published by Springer Nature in MRS Advances
- Vol. 5 (46-47) , 2419-2428
Physical characterization and in vitro evaluation of 3D printed hydroxyapatite, tricalcium phosphate, zirconia, alumina, and SiAlON structures made by lithographic ceramic manufacturing
- 1 September 2020
- Published by Springer Nature in MRS Advances
- Vol. 5 (46-47) , 2419-2428
Physical characterization and in vitro evaluation of 3D printed hydroxyapatite, tricalcium phosphate, zirconia, alumina, and SiAlON structures made by lithographic ceramic manufacturing
- Top Cited PapersOpen Access
The Photoinitiator Lithium Phenyl (2,4,6-Trimethylbenzoyl) Phosphinate with Exposure to 405 nm Light Is Cytotoxic to Mammalian Cells but Not Mutagenic in Bacterial Reverse Mutation Assays
Lithium phenyl (2,4,6-trimethylbenzoyl) phosphinate (LAP) is a free radical photo-initiator used to initiate free radical chain polymerization upon light exposure, and is combined with gelatin methacryloyl (GelMA) to produce a photopolymer used in bioprinting. The free radicals produced under bioprinting conditions are potentially cytotoxic and mutagenic. Since these photo-generated free radicals are highly-reactive but short-lived, toxicity assessments should be conducted with light exposure. In this study, photorheology determined that 10 min exposure to 9.6 mW/cm2 405 nm light from an LED light source fully crosslinked 10 wt % GelMA with >3.4 mmol/L LAP, conditions that were used for subsequent cytotoxicity and mutagenicity assessments. These conditions were cytotoxic to M-1 mouse kidney collecting duct cells, a cell type susceptible to lithium toxicity. Exposure to ≤17 mmol/L (0.5 wt %) LAP without light was not cytotoxic; however, concurrent exposure to ≥3.4 mmol/L LAP and light was cytotoxic. No condition of LAP and/or light exposure evaluated was mutagenic in bacterial reverse mutation assays using S. typhimurium strains TA98, TA100 and E. coli WP2 uvrA. These data indicate that the combination of LAP and free radicals generated from photo-excited LAP is cytotoxic, but mutagenicity was not observed in bacteria under typical bioprinting conditions.
Top Cited PapersOpen AccessThe Photoinitiator Lithium Phenyl (2,4,6-Trimethylbenzoyl) Phosphinate with Exposure to 405 nm Light Is Cytotoxic to Mammalian Cells but Not Mutagenic in Bacterial Reverse Mutation Assays
Lithium phenyl (2,4,6-trimethylbenzoyl) phosphinate (LAP) is a free radical photo-initiator used to initiate free radical chain polymerization upon light exposure, and is combined with gelatin methacryloyl (GelMA) to produce a photopolymer used in bioprinting. The free radicals produced under bioprinting conditions are potentially cytotoxic and mutagenic. Since these photo-generated free radicals are highly-reactive but short-lived, toxicity assessments should be conducted with light exposure. In this study, photorheology determined that 10 min exposure to 9.6 mW/cm2 405 nm light from an LED light source fully crosslinked 10 wt % GelMA with >3.4 mmol/L LAP, conditions that were used for subsequent cytotoxicity and mutagenicity assessments. These conditions were cytotoxic to M-1 mouse kidney collecting duct cells, a cell type susceptible to lithium toxicity. Exposure to ≤17 mmol/L (0.5 wt %) LAP without light was not cytotoxic; however, concurrent exposure to ≥3.4 mmol/L LAP and light was cytotoxic. No condition of LAP and/or light exposure evaluated was mutagenic in bacterial reverse mutation assays using S. typhimurium strains TA98, TA100 and E. coli WP2 uvrA. These data indicate that the combination of LAP and free radicals generated from photo-excited LAP is cytotoxic, but mutagenicity was not observed in bacteria under typical bioprinting conditions.
- 16 September 2019
- Published by Springer Nature in MRS Advances
- Vol. 4 (46-47) , 2541-2549
Sintered Tape-cast 3YSZ Supports Human Bone Marrow Derived Stem Cell Osteogenic Differentiation
- 16 September 2019
- Published by Springer Nature in MRS Advances
- Vol. 4 (46-47) , 2541-2549
Sintered Tape-cast 3YSZ Supports Human Bone Marrow Derived Stem Cell Osteogenic Differentiation
- Open Access
- 1 September 2019
- Published by SAGE Publications in Applied In Vitro Toxicology
- Vol. 5 (3) , 123-133
Effects of Subcytotoxic Exposure of Silver Nanoparticles on Osteogenic Differentiation of Human Bone Marrow Stem Cells
- 1 September 2019
- Published by SAGE Publications in Applied In Vitro Toxicology
- Vol. 5 (3) , 123-133
Open AccessEffects of Subcytotoxic Exposure of Silver Nanoparticles on Osteogenic Differentiation of Human Bone Marrow Stem Cells