Tyler Williamson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Tyler Williamson has a total of 57 co-authors. Here are the top co-authors by number of shared publications:
- Adam S. Garden
Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX, USA
2 shared publications - Amy Liu
Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas
2 shared publications - David I. Rosenthal
Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX, USA
2 shared publications - Jack Phan
Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX, USA
2 shared publications Albert C. Koong
Division of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, TX, United States
1 shared publicationAmy C. Moreno
Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas
1 shared publication
Latest Publications
- Open Access
- 27 March 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (7) , 075016
Deep learning techniques for proton dose prediction across multiple anatomical sites and variable beam configurations
Objective. To evaluate the impact of beam mask implementation and data aggregation on artificial intelligence-based dose prediction accuracy in proton therapy, with a focus on scenarios involving limited or highly heterogeneous datasets. Approach. In this study, 541 prostate and 632 head and neck (H&N) proton therapy plans were used to train and evaluate convolutional neural networks designed for the task of dose prediction. Datasets were grouped by anatomical site and beam configuration to assess the impact of beam masks—graphical depictions of radiation paths—as a model input. We also evaluated the effect of combining datasets. Model performance was measured using dose-volume histograms (DVHs) scores, mean absolute error, mean absolute percent error, dice similarity coefficients (DSCs), and gamma passing rates. Main results. DSC analysis revealed that the inclusion of beam masks improved dose prediction accuracy, particularly in low-dose regions and for datasets with diverse beam configurations. Data aggregation alone produced mixed results, with improvements in high-dose regions but potential degradation in low-dose areas. Notably, combining beam masks and data aggregation yielded the best overall performance, effectively leveraging the strengths of both strategies. Additionally, the magnitude of the improvements was larger for datasets with greater heterogeneity, with the combined approach increasing the DSC score by as much as 0.2 for a subgroup of H&N cases characterized by small size and heterogeneity in beam arrangement. DVH scores reflected these benefits, showing statistically significant improvements (p < 0.05) for the more heterogeneous H&N datasets. Significance. Artificial intelligence-based dose prediction models incorporating beam masks and data aggregation significantly improve accuracy in proton therapy planning, especially for complex cases. This technique could accelerate the planning process, enabling more efficient and effective cancer treatment strategies.
- 27 March 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (7) , 075016
Open AccessDeep learning techniques for proton dose prediction across multiple anatomical sites and variable beam configurations
Objective. To evaluate the impact of beam mask implementation and data aggregation on artificial intelligence-based dose prediction accuracy in proton therapy, with a focus on scenarios involving limited or highly heterogeneous datasets. Approach. In this study, 541 prostate and 632 head and neck (H&N) proton therapy plans were used to train and evaluate convolutional neural networks designed for the task of dose prediction. Datasets were grouped by anatomical site and beam configuration to assess the impact of beam masks—graphical depictions of radiation paths—as a model input. We also evaluated the effect of combining datasets. Model performance was measured using dose-volume histograms (DVHs) scores, mean absolute error, mean absolute percent error, dice similarity coefficients (DSCs), and gamma passing rates. Main results. DSC analysis revealed that the inclusion of beam masks improved dose prediction accuracy, particularly in low-dose regions and for datasets with diverse beam configurations. Data aggregation alone produced mixed results, with improvements in high-dose regions but potential degradation in low-dose areas. Notably, combining beam masks and data aggregation yielded the best overall performance, effectively leveraging the strengths of both strategies. Additionally, the magnitude of the improvements was larger for datasets with greater heterogeneity, with the combined approach increasing the DSC score by as much as 0.2 for a subgroup of H&N cases characterized by small size and heterogeneity in beam arrangement. DVH scores reflected these benefits, showing statistically significant improvements (p < 0.05) for the more heterogeneous H&N datasets. Significance. Artificial intelligence-based dose prediction models incorporating beam masks and data aggregation significantly improve accuracy in proton therapy planning, especially for complex cases. This technique could accelerate the planning process, enabling more efficient and effective cancer treatment strategies.
- Open Access
Advanced External Beam Stereotactic Radiotherapy for Skull Base Reirradiation
Background/Objectives: Stereotactic body radiation therapy (SBRT) for skull base reirradiation is particularly challenging, as patients have already received substantial radiation doses to the region, and nearby normal organs may have approached their tolerance limit from prior treatments. In this study, we reviewed the characteristics and capabilities of four advanced external beam radiation delivery systems and four modern treatment planning systems and evaluated the treatment plan quality of each technique using skull base reirradiation patient cases. Methods: SBRT plans were generated for sixteen skull base reirradiation patients using four modalities: the GK plan for the Elekta Leksell Gamma Knife Perfexion/ICON, the CyberKnife (CK) plan for the Accuray CyberKnife, the intensity-modulated proton therapy (IMPT) plan for the Hitachi ProBeat-FR proton therapy machine, and the volumetric-modulated arc therapy (VMAT) plan for the Varian TrueBeam STx. These plans were evaluated and compared using two novel gradient indices in addition to traditional dosimetry metrics for targets and organs at risk (OARs). The steepest border gradient quantified the percent prescription dose fall-off per millimeter at the boundary between the target and adjacent critical structures. This gradient index highlighted the system’s ability to spare nearby critical OARs. The volume gradient assessed the extent of dose spread outside the target toward the patient’s body. Results: All plans achieved comparable target coverage and conformity, while IMPT and VMAT demonstrated significantly better uniformity. The GK plans exhibited the highest border gradient, up to 20.9%/mm, followed by small-spot-size IMPT plans and CK plans. Additionally, IMPT plans showed the benefit of reduced dose spread in low-dose regions and the lowest maximum and mean doses to the brainstem and carotid artery. Conclusions: The advanced external beam radiotherapy modalities evaluated in this study are well-suited for SBRT in skull base reirradiation, which demands precise targeting of tumors with highly conformal doses and steep dose gradients to protect nearby normal structures.
Open AccessAdvanced External Beam Stereotactic Radiotherapy for Skull Base Reirradiation
Background/Objectives: Stereotactic body radiation therapy (SBRT) for skull base reirradiation is particularly challenging, as patients have already received substantial radiation doses to the region, and nearby normal organs may have approached their tolerance limit from prior treatments. In this study, we reviewed the characteristics and capabilities of four advanced external beam radiation delivery systems and four modern treatment planning systems and evaluated the treatment plan quality of each technique using skull base reirradiation patient cases. Methods: SBRT plans were generated for sixteen skull base reirradiation patients using four modalities: the GK plan for the Elekta Leksell Gamma Knife Perfexion/ICON, the CyberKnife (CK) plan for the Accuray CyberKnife, the intensity-modulated proton therapy (IMPT) plan for the Hitachi ProBeat-FR proton therapy machine, and the volumetric-modulated arc therapy (VMAT) plan for the Varian TrueBeam STx. These plans were evaluated and compared using two novel gradient indices in addition to traditional dosimetry metrics for targets and organs at risk (OARs). The steepest border gradient quantified the percent prescription dose fall-off per millimeter at the boundary between the target and adjacent critical structures. This gradient index highlighted the system’s ability to spare nearby critical OARs. The volume gradient assessed the extent of dose spread outside the target toward the patient’s body. Results: All plans achieved comparable target coverage and conformity, while IMPT and VMAT demonstrated significantly better uniformity. The GK plans exhibited the highest border gradient, up to 20.9%/mm, followed by small-spot-size IMPT plans and CK plans. Additionally, IMPT plans showed the benefit of reduced dose spread in low-dose regions and the lowest maximum and mean doses to the brainstem and carotid artery. Conclusions: The advanced external beam radiotherapy modalities evaluated in this study are well-suited for SBRT in skull base reirradiation, which demands precise targeting of tumors with highly conformal doses and steep dose gradients to protect nearby normal structures.
- Open Access
- 1 November 2020
- Published by Elsevier in Advances in Radiation Oncology
- Vol. 5 (6) , 1255-1266
Effect of Deep Inspiration Breath Hold on Normal Tissue Sparing With Intensity Modulated Radiation Therapy Versus Proton Therapy for Mediastinal Lymphoma
- 1 November 2020
- Published by Elsevier in Advances in Radiation Oncology
- Vol. 5 (6) , 1255-1266
Open AccessEffect of Deep Inspiration Breath Hold on Normal Tissue Sparing With Intensity Modulated Radiation Therapy Versus Proton Therapy for Mediastinal Lymphoma
- Open Access
- 1 November 2019
- Published by Elsevier in Clinical and Translational Radiation Oncology
- Vol. 19, 59-65
Definitive hyperfractionated, accelerated proton reirradiation for patients with pelvic malignancies
- 1 November 2019
- Published by Elsevier in Clinical and Translational Radiation Oncology
- Vol. 19, 59-65
Open AccessDefinitive hyperfractionated, accelerated proton reirradiation for patients with pelvic malignancies
- Open Access
- 1 April 2019
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 103 (5) , E36
A Dosimetric Comparison of Oral Cavity Sparing in the Unilateral Treatment of Early Stage Tonsil Cancer: IMRT, IMPT, and Tongue Deviating Oral Stents
- 1 April 2019
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 103 (5) , E36
Open AccessA Dosimetric Comparison of Oral Cavity Sparing in the Unilateral Treatment of Early Stage Tonsil Cancer: IMRT, IMPT, and Tongue Deviating Oral Stents