A. El Hajami
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
A. El Hajami has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
A Mribah
Nuclear Engineering Group, LISTA Laboratory, Department of Physics, Faculty of Science Dhar El Mahraz, University Sidi Mohamed Ben Abdellah, City Fez, Morocco
1 shared publicationA. Bardane
Nuclear Engineering Group, LISTA Laboratory, Department of Physics, Faculty of Science Dhar El Mahraz, University Sidi Mohamed Ben Abdellah, City Fez, Morocco
1 shared publicationA. Dadouch
Nuclear Engineering Group, LISTA Laboratory, Department of Physics, Faculty of Science Dhar El Mahraz, University Sidi Mohamed Ben Abdellah, City Fez, Morocco
1 shared publicationA. Maghnouj
Nuclear Engineering Group, LISTA Laboratory, Department of Physics, Faculty of Science Dhar El Mahraz, University Sidi Mohamed Ben Abdellah, City Fez, Morocco
1 shared publicationF. Moussahim
Nuclear Engineering Group, LISTA Laboratory, Department of Physics, Faculty of Science Dhar El Mahraz, University Sidi Mohamed Ben Abdellah, City Fez, Morocco
1 shared publicationH. El Bekouri
Nuclear Engineering Group, LISTA Laboratory, Department of Physics, Faculty of Science Dhar El Mahraz, University Sidi Mohamed Ben Abdellah, City Fez, Morocco
1 shared publication
Latest Publications
- Open Access
- 1 August 2019
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1292 (1) , 012006
Evaluation of the performance of an ionization chamber cylindrical (PTW) by the ELEKTA linear accelerator: Case of pulsed radiation
The performance evaluation of cavity cylindrical ionization chamber dosimeters is the basis for the evolution of radiotherapy treatment processes. Studies focused on the statistical and physical performances of the ionization chamber dosimeter used in the radiotherapy department at the hospital oncology CHU-Fez-Morocco. This allowed having a qualitative and quantitative critical view, which is based on previous studies and works. The diagnostic of the dispersion results was calculated between measurements that were taken by the same dosimeter under different test conditions. These tests were then rechecked against two different operators. The general purpose of our study is to optimize measurement and treatment processes, with the desired level of quality according to international standards and protocols. The evaluation of this dosimeter is made by a source of pulsed radiation. This evaluation is carried out using an ELEKTA linear accelerator, using photon beams (6, 10 and 18 Mev). Experimental Results confirmed that the response of the cylindrical ionization chamber depends on several parameters, which influence the performance of the device/machine. The study reveals a total dosimeter uncertainty of the order 3.25 %, which is in the international standards. Even, this can cause an effect on the performance of the ionization chamber detector.
- 1 August 2019
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1292 (1) , 012006
Open AccessEvaluation of the performance of an ionization chamber cylindrical (PTW) by the ELEKTA linear accelerator: Case of pulsed radiation
The performance evaluation of cavity cylindrical ionization chamber dosimeters is the basis for the evolution of radiotherapy treatment processes. Studies focused on the statistical and physical performances of the ionization chamber dosimeter used in the radiotherapy department at the hospital oncology CHU-Fez-Morocco. This allowed having a qualitative and quantitative critical view, which is based on previous studies and works. The diagnostic of the dispersion results was calculated between measurements that were taken by the same dosimeter under different test conditions. These tests were then rechecked against two different operators. The general purpose of our study is to optimize measurement and treatment processes, with the desired level of quality according to international standards and protocols. The evaluation of this dosimeter is made by a source of pulsed radiation. This evaluation is carried out using an ELEKTA linear accelerator, using photon beams (6, 10 and 18 Mev). Experimental Results confirmed that the response of the cylindrical ionization chamber depends on several parameters, which influence the performance of the device/machine. The study reveals a total dosimeter uncertainty of the order 3.25 %, which is in the international standards. Even, this can cause an effect on the performance of the ionization chamber detector.