Hasan Tariq
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hasan Tariq has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Damiano Crescini
Dipartimento di Ingegneria delI’Informazione, Brescia University, 25121 Brescia, Italy
8 shared publications - Farid Touati
Department of Electrical Engineering, College of Engineering, Qatar University, Doha 2713, Qatar
8 shared publications - Adel Ben Mnaouer
University of Prince Mugrin
7 shared publications - Mohammed Al-Hitmi
Department of Electrical Engineering, Qatar University, Doha, Qatar
3 shared publications Abderrazak Abdaoui
1 shared publication- Abderrazak Abdaoui
Qatar University College of Engineering
1 shared publication
Latest Publications
- Open Access
- 13 May 2025
- Published by IntechOpen
A Multi-Agent Infrastructure Monitoring IoT System for Urban Geo-Resilience Framework
Multi-agent systems (MAS) have emerged as a cornerstone technology in developing agile and effective resilience frameworks for geo-distributed ecosystems. These systems play a pivotal role in addressing real-time challenges in Structural Health Monitoring (SHM), where millions of distributed data-processing tasks must be executed swiftly/parrallel to ensure system resilience. Core functionalities in this context include resolving complex sustainability conflicts, detecting and characterizing anomalies in chaotic datasets, and formulating adaptive and unique resilience strategies. This work presents a multi-agent SHM system through the development of a Geo-Resilience Support System (GRSS) based on an enhanced synthetic DADO production machine architecture. The proposed multi-agent system architecture optimized the distributed data handling, rule-based decision-making, and conflict resolution by combining the advantages of GATOR, LEAPS, TREAT and RETE networks. The architecture greatly improved SHM capabilities for regional-scale resilience by utilizing agents to effectively manage working memory (WM) and apply conflict resolution methods (CRS) in alpha and beta rule networks. The system can now dynamically align left-hand-side (LHS) conditions with right-hand-side (RHS) solution sets thanks to important developments including the enrichment of condition-action rule sets and the optimization of solution strategies. With a packet throughput of 21 packets/second across geographic structures and a round-trip response time of 76.2 seconds for the initial event, the system’s usefulness is demonstrated. This work underscores the transformative potential of multi-agent SHM systems in delivering robust, scalable, and distributed solutions for geo-distributed ecosystems, enabling real-time resilience and sustainability in diverse infrastructural contexts.
- 13 May 2025
- Published by IntechOpen
Open AccessA Multi-Agent Infrastructure Monitoring IoT System for Urban Geo-Resilience Framework
Multi-agent systems (MAS) have emerged as a cornerstone technology in developing agile and effective resilience frameworks for geo-distributed ecosystems. These systems play a pivotal role in addressing real-time challenges in Structural Health Monitoring (SHM), where millions of distributed data-processing tasks must be executed swiftly/parrallel to ensure system resilience. Core functionalities in this context include resolving complex sustainability conflicts, detecting and characterizing anomalies in chaotic datasets, and formulating adaptive and unique resilience strategies. This work presents a multi-agent SHM system through the development of a Geo-Resilience Support System (GRSS) based on an enhanced synthetic DADO production machine architecture. The proposed multi-agent system architecture optimized the distributed data handling, rule-based decision-making, and conflict resolution by combining the advantages of GATOR, LEAPS, TREAT and RETE networks. The architecture greatly improved SHM capabilities for regional-scale resilience by utilizing agents to effectively manage working memory (WM) and apply conflict resolution methods (CRS) in alpha and beta rule networks. The system can now dynamically align left-hand-side (LHS) conditions with right-hand-side (RHS) solution sets thanks to important developments including the enrichment of condition-action rule sets and the optimization of solution strategies. With a packet throughput of 21 packets/second across geographic structures and a round-trip response time of 76.2 seconds for the initial event, the system’s usefulness is demonstrated. This work underscores the transformative potential of multi-agent SHM systems in delivering robust, scalable, and distributed solutions for geo-distributed ecosystems, enabling real-time resilience and sustainability in diverse infrastructural contexts.
- Open Access
- 11 April 2024
- Published by MDPI AG in Atmosphere
- Vol. 15 (4) , 471
State-of-the-Art Low-Cost Air Quality Sensors, Assemblies, Calibration and Evaluation for Respiration-Associated Diseases: A Systematic Review
Indoor air quality and respiratory health have always been an area of prime interest across the globe. The significance of low-cost air quality sensing and indoor public health practices spiked during the pandemic when indoor air pollution became a threat to living beings, especially human beings. Problem Definition: Indoor respiration-associated diseases are hard to diagnose if they are due to indoor environmental conditions. A major challenge was observed in establishing a baseline between indoor air quality sensors and associated respiratory diseases. Methods: In this work, 10,000+ articles from top literature databases were reviewed using six bibliometric analysis methods (Lorenz Curve of Citations, Hirch’s H-Index, Kosmulski’s H2-Index, Harzing’s Hl-Norm-Index, Sidoropolous’s HC-Index, and Schrieber’s HM-index) to formulate indoor air quality sensor and disease correlation publication rubrics to critically review 482 articles. Results: A set of 152 articles was found based on systematic review parameters in six bibliometric indices for publications that used WHO, NIH, US EPA, CDC, and FDA-defined principles. Five major respiratory diseases were found to be causing major death toll (up to 32%) due to five key pollutants, measured by 30+ low-cost sensors and further optimized by seven calibration systems for seven practical parameters tailored to respiratory disease baselines evaluated through 10 cost parameters. Impact: This review was conducted to assist end-users, public health facilities, state agencies, researchers, scientists, and air quality protection agencies.
- 11 April 2024
- Published by MDPI AG in Atmosphere
- Vol. 15 (4) , 471
Open AccessState-of-the-Art Low-Cost Air Quality Sensors, Assemblies, Calibration and Evaluation for Respiration-Associated Diseases: A Systematic Review
Indoor air quality and respiratory health have always been an area of prime interest across the globe. The significance of low-cost air quality sensing and indoor public health practices spiked during the pandemic when indoor air pollution became a threat to living beings, especially human beings. Problem Definition: Indoor respiration-associated diseases are hard to diagnose if they are due to indoor environmental conditions. A major challenge was observed in establishing a baseline between indoor air quality sensors and associated respiratory diseases. Methods: In this work, 10,000+ articles from top literature databases were reviewed using six bibliometric analysis methods (Lorenz Curve of Citations, Hirch’s H-Index, Kosmulski’s H2-Index, Harzing’s Hl-Norm-Index, Sidoropolous’s HC-Index, and Schrieber’s HM-index) to formulate indoor air quality sensor and disease correlation publication rubrics to critically review 482 articles. Results: A set of 152 articles was found based on systematic review parameters in six bibliometric indices for publications that used WHO, NIH, US EPA, CDC, and FDA-defined principles. Five major respiratory diseases were found to be causing major death toll (up to 32%) due to five key pollutants, measured by 30+ low-cost sensors and further optimized by seven calibration systems for seven practical parameters tailored to respiratory disease baselines evaluated through 10 cost parameters. Impact: This review was conducted to assist end-users, public health facilities, state agencies, researchers, scientists, and air quality protection agencies.
- Open Access
- 18 July 2023
- Published by MDPI AG in Preprints.org
A Systematic Review of Low-Cost Real-time Air Quality Sensors, Systems, and Evaluation Methods
Air quality and environmental fairness have always been an area of prime interest across the globe. The significance low-cost air quality sensing and practices spikes during the time of pan-demic and epidemics when the air becomes a threat to living beings especially human beings. The gradual innovation and enrichment in low-cost air quality sensing sensors, nodes or devices, and systems are exponentially increasing for the last three decades. This work reviews the major contributions in a) low-cost scalable air quality assessment; b) low-cost air quality sensors, sensing approaches and technologies; c) low-cost state-of-the-art gas sensors fabrication methods (MEMS and CMOS); d) low-cost gas sensors measurement configurations and assemblies; and e) low-cost air quality sensors calibration and testing systems. A systematic review of past work with a goal to assist end-users, public health facilities, state agencies, researchers, scientists and air quality protection agencies has been rendered in this work. Starting from sensors electrodes to IoT based mobile smart nodes; all have been introduced in this article.
- 18 July 2023
- Published by MDPI AG in Preprints.org
Open AccessA Systematic Review of Low-Cost Real-time Air Quality Sensors, Systems, and Evaluation Methods
Air quality and environmental fairness have always been an area of prime interest across the globe. The significance low-cost air quality sensing and practices spikes during the time of pan-demic and epidemics when the air becomes a threat to living beings especially human beings. The gradual innovation and enrichment in low-cost air quality sensing sensors, nodes or devices, and systems are exponentially increasing for the last three decades. This work reviews the major contributions in a) low-cost scalable air quality assessment; b) low-cost air quality sensors, sensing approaches and technologies; c) low-cost state-of-the-art gas sensors fabrication methods (MEMS and CMOS); d) low-cost gas sensors measurement configurations and assemblies; and e) low-cost air quality sensors calibration and testing systems. A systematic review of past work with a goal to assist end-users, public health facilities, state agencies, researchers, scientists and air quality protection agencies has been rendered in this work. Starting from sensors electrodes to IoT based mobile smart nodes; all have been introduced in this article.
- Open Access
- 10 March 2023
- Published by MDPI AG in Atmosphere
- Vol. 14 (3) , 534
IoT-Based Bi-Cluster Forecasting Using Automated ML-Model Optimization for COVID-19
The current COVID-19 pandemic has raised huge concerns about outdoor air quality due to the expected lung deterioration. These concerns include the challenges associated with an increase of harmful gases like carbon dioxide, the iterative/repetitive inhalation due to mask usage, and harsh environmental temperatures. Even in the presence of air quality sensing devices, these challenges can hinder the prevention and treatment of respiratory diseases, epidemics, and pandemics in severe cases. In this research, a dual time series with a bi-cluster sensor data-stream-based novel optimized regression algorithm was proposed with optimization predictors and responses that use an automated iterative optimization of the model based on the similarity coefficient index. The algorithm was implemented over SeReNoV2 sensor nodes data, i.e., a multi-variate dual time-series sensor, of the environmental and US Environmental Protection Agency standard, which measures variables for the air quality index using air quality sensors with geospatial profiling. The SeReNoV2 systems were placed at four locations that were 3 km apart to monitor the air quality and their data was collected at Ubidots IoT platform over GSM. The results have shown that the proposed technique achieved a root mean square error (RMSE) of 1.0042 with a training time of 469.28 s for the control and an RMSE of 1.646 in a training time of 28.53 s when optimized. The estimated R-Squared error was 0.03, with the Mean-Square Error for temperature being 1.0084 °C, and 293.98 ppm for CO2. Furthermore, the Mean-Absolute Error (MAE) for temperature was 0.66226 °C and 10.252 ppm for the correlated-CO2 at a predicted speed of ~5100 observations/s. In the sample cluster for temperature, 45,000 observations/s for CO2 was achieved due to the iterative optimization of the training time (469.28 s). The correlated temperature and a time of 28.53 s for CO2 were very promising in forecasting COVID-19 countermeasures before time.
- 10 March 2023
- Published by MDPI AG in Atmosphere
- Vol. 14 (3) , 534
Open AccessIoT-Based Bi-Cluster Forecasting Using Automated ML-Model Optimization for COVID-19
The current COVID-19 pandemic has raised huge concerns about outdoor air quality due to the expected lung deterioration. These concerns include the challenges associated with an increase of harmful gases like carbon dioxide, the iterative/repetitive inhalation due to mask usage, and harsh environmental temperatures. Even in the presence of air quality sensing devices, these challenges can hinder the prevention and treatment of respiratory diseases, epidemics, and pandemics in severe cases. In this research, a dual time series with a bi-cluster sensor data-stream-based novel optimized regression algorithm was proposed with optimization predictors and responses that use an automated iterative optimization of the model based on the similarity coefficient index. The algorithm was implemented over SeReNoV2 sensor nodes data, i.e., a multi-variate dual time-series sensor, of the environmental and US Environmental Protection Agency standard, which measures variables for the air quality index using air quality sensors with geospatial profiling. The SeReNoV2 systems were placed at four locations that were 3 km apart to monitor the air quality and their data was collected at Ubidots IoT platform over GSM. The results have shown that the proposed technique achieved a root mean square error (RMSE) of 1.0042 with a training time of 469.28 s for the control and an RMSE of 1.646 in a training time of 28.53 s when optimized. The estimated R-Squared error was 0.03, with the Mean-Square Error for temperature being 1.0084 °C, and 293.98 ppm for CO2. Furthermore, the Mean-Absolute Error (MAE) for temperature was 0.66226 °C and 10.252 ppm for the correlated-CO2 at a predicted speed of ~5100 observations/s. In the sample cluster for temperature, 45,000 observations/s for CO2 was achieved due to the iterative optimization of the training time (469.28 s). The correlated temperature and a time of 28.53 s for CO2 were very promising in forecasting COVID-19 countermeasures before time.
- Open Access
- 1 March 2023
- Published by MDPI AG in Preprints.org
A Review of State-of-the-Art Low-Cost Sensors for Detection of Indoor Air Pollutants that Correlate with Health
Indoor air quality and public health have always been an area of prime interest across the globe. The significance of low-cost air quality sensing and indoor public health practices spikes during the time of pandemic and epidemics when indoor air pollution becomes a threat to living beings especially human beings. Indoor diseases are hard to diagnose if they are due to the indoor environmental conditions. A major challenge was observed in establishing a baseline between the indoor air quality sensors and associated diseases. In this work, 10,000+ articles from top literature databases were reviewed using bibliometric analysis to formulate indoor air quality sensors and diseases correlation rubrics to critically review 500+ articles. A set of 200+ articles were selected based on for detailed study based on seven bibliometric indices for publications that used WHO, NIH, US EPA, CDC, and FDA defined principles. This review has been conducted to assist end-users, public health facilities, state agencies, researchers, scientists and air quality protection agencies.
- 1 March 2023
- Published by MDPI AG in Preprints.org
Open AccessA Review of State-of-the-Art Low-Cost Sensors for Detection of Indoor Air Pollutants that Correlate with Health
Indoor air quality and public health have always been an area of prime interest across the globe. The significance of low-cost air quality sensing and indoor public health practices spikes during the time of pandemic and epidemics when indoor air pollution becomes a threat to living beings especially human beings. Indoor diseases are hard to diagnose if they are due to the indoor environmental conditions. A major challenge was observed in establishing a baseline between the indoor air quality sensors and associated diseases. In this work, 10,000+ articles from top literature databases were reviewed using bibliometric analysis to formulate indoor air quality sensors and diseases correlation rubrics to critically review 500+ articles. A set of 200+ articles were selected based on for detailed study based on seven bibliometric indices for publications that used WHO, NIH, US EPA, CDC, and FDA defined principles. This review has been conducted to assist end-users, public health facilities, state agencies, researchers, scientists and air quality protection agencies.
- Open Access
- 28 December 2022
- Published by MDPI AG in Preprints.org
An IoT-based Bi-Cluster Forecasting using Automated ML-Model Optimization for COVID19
The current COVID19 pandemic has raised huge concerns for outdoor air quality due to expected lungs deterioration. These concerns include the challenges in the scalable prediction of harmful gases like carbon dioxide, iterative/repetitive inhaling due to mask and environmental temperature harshness. Even in the presence of air quality sensing devices, these challenges lead to failed planning and strategy against respiratory diseases, epidemics, and pandemics in severe cases. In this work, a dual time-series with bi-cluster sensor data-stream-based novel optimized regression algorithm was proposed with optimization predictors and optimization responses that use automated iterative optimization of the model based on the similarity coefficient index. The algorithm was implemented over SeReNoV2 sensor nodes data, i.e. multi-variate dual time-series of environmental and US Environmental Protection Agency standard sensor variables for air quality index measured from air quality sensors with geospatial profiling. The SeReNoV2 systems were placed at four locations that were 3 km apart to monitor air quality and their data was collected at Ubidots IoT platform over GSM. Results have shown that the proposed technique achieved a root mean square error (RMSE) of 1.0042 with a training time of 469.28 seconds for normal and RMSE of 1.646 in the training time of 28.53 seconds for optimization. The estimated R-Squared error of 0.03 with Mean-Square Error for temperature 1.0084 ᵒC and 293.98 ppm for CO2 was observed. Furthermore, the Mean-Absolute Error (MAE) for temperature 0.66226 ᵒC and 10.252 ppm for CO2 at a prediction speed of ~5100 observations/second for temperature 45000 observations/second for CO2 due to iterative optimization of the training time 469.28 seconds for temperature and 28.53 seconds for CO2 was very promising in forecasting COVID19 countermeasures before time.
- 28 December 2022
- Published by MDPI AG in Preprints.org
Open AccessAn IoT-based Bi-Cluster Forecasting using Automated ML-Model Optimization for COVID19
The current COVID19 pandemic has raised huge concerns for outdoor air quality due to expected lungs deterioration. These concerns include the challenges in the scalable prediction of harmful gases like carbon dioxide, iterative/repetitive inhaling due to mask and environmental temperature harshness. Even in the presence of air quality sensing devices, these challenges lead to failed planning and strategy against respiratory diseases, epidemics, and pandemics in severe cases. In this work, a dual time-series with bi-cluster sensor data-stream-based novel optimized regression algorithm was proposed with optimization predictors and optimization responses that use automated iterative optimization of the model based on the similarity coefficient index. The algorithm was implemented over SeReNoV2 sensor nodes data, i.e. multi-variate dual time-series of environmental and US Environmental Protection Agency standard sensor variables for air quality index measured from air quality sensors with geospatial profiling. The SeReNoV2 systems were placed at four locations that were 3 km apart to monitor air quality and their data was collected at Ubidots IoT platform over GSM. Results have shown that the proposed technique achieved a root mean square error (RMSE) of 1.0042 with a training time of 469.28 seconds for normal and RMSE of 1.646 in the training time of 28.53 seconds for optimization. The estimated R-Squared error of 0.03 with Mean-Square Error for temperature 1.0084 ᵒC and 293.98 ppm for CO2 was observed. Furthermore, the Mean-Absolute Error (MAE) for temperature 0.66226 ᵒC and 10.252 ppm for CO2 at a prediction speed of ~5100 observations/second for temperature 45000 observations/second for CO2 due to iterative optimization of the training time 469.28 seconds for temperature and 28.53 seconds for CO2 was very promising in forecasting COVID19 countermeasures before time.
- Open Access
- 1 December 2020
- Published by ASTES Journal in Advances in Science, Technology and Engineering Systems Journal
- Vol. 5 (6) , 1666-1673
Real-time Gradient-Aware Indigenous AQI Estimation IoT Platform
- 1 December 2020
- Published by ASTES Journal in Advances in Science, Technology and Engineering Systems Journal
- Vol. 5 (6) , 1666-1673
Open AccessReal-time Gradient-Aware Indigenous AQI Estimation IoT Platform
- Open Access
A Smart Rig for Calibration of Gas Sensor Nodes
Electrochemical gas sensors require regular maintenance to check and secure proper functioning. Standard procedures usually involve testing and recalibration of the sensors, for which working environments are needed. Periodic calibration is therefore necessary to ensure reliable and accurate measurements. This paper proposes a dedicated smart calibration rig with a set of novel features enabling simultaneous calibration of multiple sensors. The proposed calibration rig system comprises a gas mixing system, temperature control system, a test chamber, and a process-control PC that controls all calibration phases. The calibration process is automated by a LabVIEW-based platform that controls the calibration environment for the sensor nodes, logs sensor data, and best fit equation based on interpolation for every sensor on the node and uploads it to the sensor node for next deployments. The communication between the PC and the sensor nodes is performed using the same IEEE 802.15.4 (ZigBee) protocol that the nodes also use in field deployment for air quality measurement. The results presented demonstrate the effectiveness of the sensors calibration rig.
Open AccessA Smart Rig for Calibration of Gas Sensor Nodes
Electrochemical gas sensors require regular maintenance to check and secure proper functioning. Standard procedures usually involve testing and recalibration of the sensors, for which working environments are needed. Periodic calibration is therefore necessary to ensure reliable and accurate measurements. This paper proposes a dedicated smart calibration rig with a set of novel features enabling simultaneous calibration of multiple sensors. The proposed calibration rig system comprises a gas mixing system, temperature control system, a test chamber, and a process-control PC that controls all calibration phases. The calibration process is automated by a LabVIEW-based platform that controls the calibration environment for the sensor nodes, logs sensor data, and best fit equation based on interpolation for every sensor on the node and uploads it to the sensor node for next deployments. The communication between the PC and the sensor nodes is performed using the same IEEE 802.15.4 (ZigBee) protocol that the nodes also use in field deployment for air quality measurement. The results presented demonstrate the effectiveness of the sensors calibration rig.
- Open Access
- 4 September 2019
- Published by MDPI AG in Applied Sciences
- Vol. 9 (18) , 3650
A Real-Time Early Warning Seismic Event Detection Algorithm Using Smart Geo-Spatial Bi-Axial Inclinometer Nodes for Industry 4.0 Applications
Earthquakes are one of the major natural calamities as well as a prime subject of interest for seismologists, state agencies, and ground motion instrumentation scientists. The real-time data analysis of multi-sensor instrumentation is a valuable knowledge repository for real-time early warning and trustworthy seismic events detection. In this work, an early warning in the first 1 micro-second and seismic wave detection in the first 1.7 milliseconds after event initialization is proposed using a seismic wave event detection algorithm (SWEDA). The SWEDA with nine low-computation-cost operations is being proposed for smart geospatial bi-axial inclinometer nodes (SGBINs) also utilized in structural health monitoring systems. SWEDA detects four types of seismic waves, i.e., primary (P) or compression, secondary (S) or shear, Love (L), and Rayleigh (R) waves using time and frequency domain parameters mapped on a 2D mapping interpretation scheme. The SWEDA proved automated heterogeneous surface adaptability, multi-clustered sensing, ubiquitous monitoring with dynamic Savitzky–Golay filtering and detection using nine optimized sequential and structured event characterization techniques. Furthermore, situation-conscious (context-aware) and automated computation of short-time average over long-time average (STA/LTA) triggering parameters by peak-detection and run-time scaling arrays with manual computation support were achieved.
- 4 September 2019
- Published by MDPI AG in Applied Sciences
- Vol. 9 (18) , 3650
Open AccessA Real-Time Early Warning Seismic Event Detection Algorithm Using Smart Geo-Spatial Bi-Axial Inclinometer Nodes for Industry 4.0 Applications
Earthquakes are one of the major natural calamities as well as a prime subject of interest for seismologists, state agencies, and ground motion instrumentation scientists. The real-time data analysis of multi-sensor instrumentation is a valuable knowledge repository for real-time early warning and trustworthy seismic events detection. In this work, an early warning in the first 1 micro-second and seismic wave detection in the first 1.7 milliseconds after event initialization is proposed using a seismic wave event detection algorithm (SWEDA). The SWEDA with nine low-computation-cost operations is being proposed for smart geospatial bi-axial inclinometer nodes (SGBINs) also utilized in structural health monitoring systems. SWEDA detects four types of seismic waves, i.e., primary (P) or compression, secondary (S) or shear, Love (L), and Rayleigh (R) waves using time and frequency domain parameters mapped on a 2D mapping interpretation scheme. The SWEDA proved automated heterogeneous surface adaptability, multi-clustered sensing, ubiquitous monitoring with dynamic Savitzky–Golay filtering and detection using nine optimized sequential and structured event characterization techniques. Furthermore, situation-conscious (context-aware) and automated computation of short-time average over long-time average (STA/LTA) triggering parameters by peak-detection and run-time scaling arrays with manual computation support were achieved.