Faisal Hossain
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Faisal Hossain has a total of 47 co-authors. Here are the top co-authors by number of shared publications:
- Michael J. Serpe
Department of Chemistry, University of Alberta, Edmonton, AB, T6G 2G2, Canada
6 shared publications - Akio Ohta
Institute of Science and Engineering, Kanazawa University, Kakuma, Kanazawa 920-1192, Japan
3 shared publications - Michael A. Joyce
University of Alberta
3 shared publications - Mohammed Jamaluddin Ahmed
Laboratory of Analytical Chemistry, Department of Chemistry, University of Chittagong, Chittagong-4331, Bangladesh
3 shared publications Tsuyoshi Asakawa
Faculty of Chemistry Institute of Science and Engineering, Kanazawa University Kanazawa Ishikawa 920‐1192 Japan
3 shared publicationsD. Lorne Tyrrell
Department of Medical Microbiology and Immunology, University of Alberta, Edmonton, Alberta T6G 2E1, Canada
2 shared publications
Latest Publications
- Open Access
- 10 April 2026
- Published by Royal Society of Chemistry (RSC) in Sensors & Diagnostics
- Vol. 5 (5) , 739-748
Quantification of avian influenza A virus (H5N1) via enzymatic reactions and glucometer test strips
A sensor capable of quantifying avian influenza A virus (subtype H5) was developed by targeting hemagglutinin (HA) protein. This was accomplished by designing a solution-based sandwich assay that generated orthophosphate (PO4 3−) in proportion to the concentration of HA protein (and hence virus particles) present in a sample. Virus particles were captured and concentrated using an H5-specific primary antibody conjugated to magnetic microparticles. Following magnetic separation, an alkaline phosphatase (AP)-conjugated secondary antibody was introduced to bind to the captured virus. The resulting assembly was exposed to p-nitrophenyl phosphate (PNPP), producing PO4 3− in proportion to the amount of virus present. The generated phosphate was subsequently converted to glucose through the addition of maltose and maltose phosphorylase, and the resulting glucose was quantified amperometrically using an off-the-shelf commercial glucose test strip interfaced with a mini-potentiostat. Using this approach, limits of detection of 7.78 × 105 RNA copies per mL in binding buffer, 1.46 × 106 RNA copies per mL in artificial saliva, and 1.26 × 106 RNA copies per mL in tap water were obtained. Selectivity was demonstrated against respiratory pathogen pools, representative Gram-positive and Gram-negative bacteria, and severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). This work presents a modular immunoassay-based strategy that leverages widely available glucose test strips for quantitative viral detection in a laboratory proof-of-concept format and may be adaptable to other targets through substitution of capture and detection antibodies.
- 10 April 2026
- Published by Royal Society of Chemistry (RSC) in Sensors & Diagnostics
- Vol. 5 (5) , 739-748
Open AccessQuantification of avian influenza A virus (H5N1) via enzymatic reactions and glucometer test strips
A sensor capable of quantifying avian influenza A virus (subtype H5) was developed by targeting hemagglutinin (HA) protein. This was accomplished by designing a solution-based sandwich assay that generated orthophosphate (PO4 3−) in proportion to the concentration of HA protein (and hence virus particles) present in a sample. Virus particles were captured and concentrated using an H5-specific primary antibody conjugated to magnetic microparticles. Following magnetic separation, an alkaline phosphatase (AP)-conjugated secondary antibody was introduced to bind to the captured virus. The resulting assembly was exposed to p-nitrophenyl phosphate (PNPP), producing PO4 3− in proportion to the amount of virus present. The generated phosphate was subsequently converted to glucose through the addition of maltose and maltose phosphorylase, and the resulting glucose was quantified amperometrically using an off-the-shelf commercial glucose test strip interfaced with a mini-potentiostat. Using this approach, limits of detection of 7.78 × 105 RNA copies per mL in binding buffer, 1.46 × 106 RNA copies per mL in artificial saliva, and 1.26 × 106 RNA copies per mL in tap water were obtained. Selectivity was demonstrated against respiratory pathogen pools, representative Gram-positive and Gram-negative bacteria, and severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). This work presents a modular immunoassay-based strategy that leverages widely available glucose test strips for quantitative viral detection in a laboratory proof-of-concept format and may be adaptable to other targets through substitution of capture and detection antibodies.
- Open Access
- 5 February 2025
- Published by Royal Society of Chemistry (RSC) in Sensors & Diagnostics
- Vol. 4 (3) , 256-264
Label-free quantification of single-stranded DNA utilizing enzymatic digestion and an off-the-shelf glucose test strip
A method was developed for quantifying single-stranded DNA (ssDNA) through enzymatic digestion and using commercially available glucose test strips.
- 5 February 2025
- Published by Royal Society of Chemistry (RSC) in Sensors & Diagnostics
- Vol. 4 (3) , 256-264
Open AccessLabel-free quantification of single-stranded DNA utilizing enzymatic digestion and an off-the-shelf glucose test strip
A method was developed for quantifying single-stranded DNA (ssDNA) through enzymatic digestion and using commercially available glucose test strips.
- 12 February 2024
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 9 (2) , 971-978
Method for Glucose and Fructose Quantitation in Beverages Using an Off-the-Shelf Glucose Test Strip
A method was developed for quantifying both glucose and fructose in solutions and grape juice using commercially available glucose test strips connected to a mini-potentiostat. The first step of this sensing approach involved exposing the sample solution to an Accu Chek Aviva glucose test strip, which allowed for the direct quantitation of glucose. To quantify fructose, the solution was exposed to glucose isomerase, which led to the conversion of glucose to fructose and vice versa until an equilibrium was reached. Once equilibrium was reached, the solution was exposed to another glucose test strip; the signal obtained was shown to be related to the total amounts of glucose and fructose in solution. Finally, fructose was quantified by subtracting the glucose concentration (from the initial measurement) from the total concentration of glucose and fructose (from the second measurement after the reaction with glucose isomerase). The method yielded a limit of detection of 0.047 g L-1 for glucose and 0.49 g L-1 for fructose. Importantly, this method was shown to work well for analyzing glucose and fructose concentration in grape juice, which contains >60 g L-1 glucose and fructose. Since the ratio of glucose and fructose concentration in ripe grapes is close to 1, this method can be used to aid in the determination of grape ripeness to guide harvesting times.
- 12 February 2024
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 9 (2) , 971-978
Method for Glucose and Fructose Quantitation in Beverages Using an Off-the-Shelf Glucose Test Strip
A method was developed for quantifying both glucose and fructose in solutions and grape juice using commercially available glucose test strips connected to a mini-potentiostat. The first step of this sensing approach involved exposing the sample solution to an Accu Chek Aviva glucose test strip, which allowed for the direct quantitation of glucose. To quantify fructose, the solution was exposed to glucose isomerase, which led to the conversion of glucose to fructose and vice versa until an equilibrium was reached. Once equilibrium was reached, the solution was exposed to another glucose test strip; the signal obtained was shown to be related to the total amounts of glucose and fructose in solution. Finally, fructose was quantified by subtracting the glucose concentration (from the initial measurement) from the total concentration of glucose and fructose (from the second measurement after the reaction with glucose isomerase). The method yielded a limit of detection of 0.047 g L-1 for glucose and 0.49 g L-1 for fructose. Importantly, this method was shown to work well for analyzing glucose and fructose concentration in grape juice, which contains >60 g L-1 glucose and fructose. Since the ratio of glucose and fructose concentration in ripe grapes is close to 1, this method can be used to aid in the determination of grape ripeness to guide harvesting times.
- 14 June 2023
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 15 (25) , 29914-29926
Bovine Serum Albumin-Protected Gold Nanoclusters for Sensing of SARS-CoV-2 Antibodies and Virus
An approach to assess severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection (and past infection) was developed. For virus detection, the SARS-CoV-2 virus nucleocapsid protein (NP) was targeted. To detect the NP, antibodies were immobilized on magnetic beads to capture the NPs, which were subsequently detected using rabbit anti-SARS-CoV-2 nucleocapsid antibodies and alkaline phosphatase (AP)-conjugated anti-rabbit antibodies. A similar approach was used to assess SARS-CoV-2-neutralizing antibody levels by capturing spike receptor-binding domain (RBD)-specific antibodies utilizing RBD protein-modified magnetic beads and detecting them using AP-conjugated anti-human IgG antibodies. The sensing mechanism for both assays is based on cysteamine etching-induced fluorescence quenching of bovine serum albumin-protected gold nanoclusters where cysteamine is generated in proportion to the amount of either SARS-CoV-2 virus or anti-SARS-CoV-2 receptor-binding domain-specific immunoglobulin antibodies (anti-RBD IgG antibodies). High sensitivity can be achieved in 5 h 15 min for the anti-RBD IgG antibody detection and 6 h 15 min for virus detection, although the assay can be run in "rapid" mode, which takes 1 h 45 min for the anti-RBD IgG antibody detection and 3 h 15 min for the virus. By spiking the anti-RBD IgG antibodies and virus in serum and saliva, we demonstrate that the assay can detect the anti-RBD IgG antibodies with a limit of detection (LOD) of 4.0 and 2.0 ng/mL in serum and saliva, respectively. For the virus, we can achieve an LOD of 8.5 × 105 RNA copies/mL and 8.8 × 105 RNA copies/mL in serum and saliva, respectively. Interestingly, this assay can be easily modified to detect myriad analytes of interest.
- 14 June 2023
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 15 (25) , 29914-29926
Bovine Serum Albumin-Protected Gold Nanoclusters for Sensing of SARS-CoV-2 Antibodies and Virus
An approach to assess severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection (and past infection) was developed. For virus detection, the SARS-CoV-2 virus nucleocapsid protein (NP) was targeted. To detect the NP, antibodies were immobilized on magnetic beads to capture the NPs, which were subsequently detected using rabbit anti-SARS-CoV-2 nucleocapsid antibodies and alkaline phosphatase (AP)-conjugated anti-rabbit antibodies. A similar approach was used to assess SARS-CoV-2-neutralizing antibody levels by capturing spike receptor-binding domain (RBD)-specific antibodies utilizing RBD protein-modified magnetic beads and detecting them using AP-conjugated anti-human IgG antibodies. The sensing mechanism for both assays is based on cysteamine etching-induced fluorescence quenching of bovine serum albumin-protected gold nanoclusters where cysteamine is generated in proportion to the amount of either SARS-CoV-2 virus or anti-SARS-CoV-2 receptor-binding domain-specific immunoglobulin antibodies (anti-RBD IgG antibodies). High sensitivity can be achieved in 5 h 15 min for the anti-RBD IgG antibody detection and 6 h 15 min for virus detection, although the assay can be run in "rapid" mode, which takes 1 h 45 min for the anti-RBD IgG antibody detection and 3 h 15 min for the virus. By spiking the anti-RBD IgG antibodies and virus in serum and saliva, we demonstrate that the assay can detect the anti-RBD IgG antibodies with a limit of detection (LOD) of 4.0 and 2.0 ng/mL in serum and saliva, respectively. For the virus, we can achieve an LOD of 8.5 × 105 RNA copies/mL and 8.8 × 105 RNA copies/mL in serum and saliva, respectively. Interestingly, this assay can be easily modified to detect myriad analytes of interest.
- 8 May 2023
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 95 (19) , 7620-7629
Utilization of a Glucometer Test Strip and Enzymatic Reactions to Quantify Anti-SARS-CoV-2 Spike RBD IgG Antibody and SARS-CoV-2 Virus in Saliva and Serum
A sensor capable of quantifying both anti-SARS-CoV-2 spike receptor-binding domain (RBD) antibody levels and the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) virus in saliva and serum was developed. This was accomplished by exploiting the enzymatic reaction of maltose and orthophosphate (PO43-) in the presence of maltose phosphorylase to generate an equivalent amount of glucose that was detected using a commercial glucometer test strip and a potentiostat. Important for this approach is the ability to generate PO43- in an amount that is directly related to the concentration of the analytes. RBD-modified magnetic microparticles were used to capture anti-SARS-CoV-2 spike RBD antibodies, while particles modified with anti-SARS-CoV-2 nucleocapsid antibodies were used to capture SARS-CoV-2 nucleocapsid protein from inactivated virus samples. A magnet was used to isolate and purify the magnetic microparticles (with analyte attached), and alkaline phosphatase-conjugated secondary antibodies were bound to the analytes attached to the respective magnetic microparticles. Finally, through enzymatic reactions, specific amounts of PO43- (and subsequently glucose) were generated in proportion to the analyte concentration, which was then quantified using a commercial glucometer test strip. Utilizing glucose test strips makes the sensor relatively inexpensive, with a cost per test of ∼US $7 and ∼US $12 for quantifying anti-SARS-CoV-2 spike RBD antibody and SARS-CoV-2, respectively. Our sensor exhibited a limit of detection of 0.42 ng/mL for anti-SARS-CoV-2 spike RBD antibody, which is sensitive enough to quantify typical concentrations of antibodies in COVID-19-infected or vaccinated individuals (>1 μg/mL). The limit of detection for the SARS-CoV-2 virus is 300 pfu/mL (5.4 × 106 RNA copies/mL), which exceeds the performance recommended by the WHO (500 pfu/mL). In addition, the sensor exhibited good selectivity when challenged with competing analytes and could be used to quantify analytes in saliva and serum matrices with an accuracy of >94% compared to RT-qPCR.
- 8 May 2023
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 95 (19) , 7620-7629
Utilization of a Glucometer Test Strip and Enzymatic Reactions to Quantify Anti-SARS-CoV-2 Spike RBD IgG Antibody and SARS-CoV-2 Virus in Saliva and Serum
A sensor capable of quantifying both anti-SARS-CoV-2 spike receptor-binding domain (RBD) antibody levels and the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) virus in saliva and serum was developed. This was accomplished by exploiting the enzymatic reaction of maltose and orthophosphate (PO43-) in the presence of maltose phosphorylase to generate an equivalent amount of glucose that was detected using a commercial glucometer test strip and a potentiostat. Important for this approach is the ability to generate PO43- in an amount that is directly related to the concentration of the analytes. RBD-modified magnetic microparticles were used to capture anti-SARS-CoV-2 spike RBD antibodies, while particles modified with anti-SARS-CoV-2 nucleocapsid antibodies were used to capture SARS-CoV-2 nucleocapsid protein from inactivated virus samples. A magnet was used to isolate and purify the magnetic microparticles (with analyte attached), and alkaline phosphatase-conjugated secondary antibodies were bound to the analytes attached to the respective magnetic microparticles. Finally, through enzymatic reactions, specific amounts of PO43- (and subsequently glucose) were generated in proportion to the analyte concentration, which was then quantified using a commercial glucometer test strip. Utilizing glucose test strips makes the sensor relatively inexpensive, with a cost per test of ∼US $7 and ∼US $12 for quantifying anti-SARS-CoV-2 spike RBD antibody and SARS-CoV-2, respectively. Our sensor exhibited a limit of detection of 0.42 ng/mL for anti-SARS-CoV-2 spike RBD antibody, which is sensitive enough to quantify typical concentrations of antibodies in COVID-19-infected or vaccinated individuals (>1 μg/mL). The limit of detection for the SARS-CoV-2 virus is 300 pfu/mL (5.4 × 106 RNA copies/mL), which exceeds the performance recommended by the WHO (500 pfu/mL). In addition, the sensor exhibited good selectivity when challenged with competing analytes and could be used to quantify analytes in saliva and serum matrices with an accuracy of >94% compared to RT-qPCR.
- 21 January 2022
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 94 (4) , 2056-2062
Orthophosphate Quantification in Water Utilizing an Enzymatic Reaction and a Commercial Glucometer Test Strip
A sensor for the determination of orthophosphate (PO43–) concentration in water was developed that utilizes the enzymatic cleavage of maltose in the presence of PO43– to generate an equivalent amount of glucose. The glucose produced from this reaction was quantified using a commercial glucometer test strip coupled to a miniature potentiostat using amperometry. This sensing approach yielded a limit of detection of 1.45 μM (0.1 ppm) glucose/PO43–, which is lower than that of a commercial glucometer (≥600 μM glucose), and a dynamic range of 10 μM–3 mM. The selectivity of the approach to PO43– was evaluated by determining the device’s response to known components in natural water samples. Finally, we showed that the approach can be used to determine PO43– in tap and river water samples.
- 21 January 2022
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 94 (4) , 2056-2062
Orthophosphate Quantification in Water Utilizing an Enzymatic Reaction and a Commercial Glucometer Test Strip
A sensor for the determination of orthophosphate (PO43–) concentration in water was developed that utilizes the enzymatic cleavage of maltose in the presence of PO43– to generate an equivalent amount of glucose. The glucose produced from this reaction was quantified using a commercial glucometer test strip coupled to a miniature potentiostat using amperometry. This sensing approach yielded a limit of detection of 1.45 μM (0.1 ppm) glucose/PO43–, which is lower than that of a commercial glucometer (≥600 μM glucose), and a dynamic range of 10 μM–3 mM. The selectivity of the approach to PO43– was evaluated by determining the device’s response to known components in natural water samples. Finally, we showed that the approach can be used to determine PO43– in tap and river water samples.
- Open Access
- 30 June 2020
- Published by European Journal of Chemistry in European Journal of Chemistry
- Vol. 11 (2) , 160-167
A Highly Selective and Simple Spectrophotometric Method for the Determination of Zinc at Nano-trace Levels in Some Environmental, Biological, Food, and Pharmaceutical Samples Using 2-hydroxynaphthaldehydebenzoylhydrazone
A simple, ultra-sensitive, and highly selective spectrophotometric method has been established for the trace quantification of zinc (Zn), using 2-hydroxynaphthaldehyde benzoylhydrazone (HNABH). Zn forms a pale yellowish-green complex (maximum absorption at 426 nm) with HNABH (1:1, v:v) in a marginally acidic solution (0.00005-0.00023 M H2SO4). The average molar absorption coefficient and Sandell’s sensitivity were found: 2.87×105 L/mol.cm and 12 ng/cm2 of Zn, respectively. The observed linearity range for Zn was 0.01-50 mg/Lwith a detection limit of 1 µg/L. The analysis of biological, food, and vegetable samples using the suggested method were found to be in tremendous accord with those acquired by Atomic Absorption Spectroscopy (AAS) and Inductively Coupled Plasma-Optical Emission Spectroscopy (ICP-OES). The method has high precision and accuracy (s = ±0.01 for 0.5 mg/L). The limit of quantification of the proposed method was 10 µg/L.
- 30 June 2020
- Published by European Journal of Chemistry in European Journal of Chemistry
- Vol. 11 (2) , 160-167
Open AccessA Highly Selective and Simple Spectrophotometric Method for the Determination of Zinc at Nano-trace Levels in Some Environmental, Biological, Food, and Pharmaceutical Samples Using 2-hydroxynaphthaldehydebenzoylhydrazone
A simple, ultra-sensitive, and highly selective spectrophotometric method has been established for the trace quantification of zinc (Zn), using 2-hydroxynaphthaldehyde benzoylhydrazone (HNABH). Zn forms a pale yellowish-green complex (maximum absorption at 426 nm) with HNABH (1:1, v:v) in a marginally acidic solution (0.00005-0.00023 M H2SO4). The average molar absorption coefficient and Sandell’s sensitivity were found: 2.87×105 L/mol.cm and 12 ng/cm2 of Zn, respectively. The observed linearity range for Zn was 0.01-50 mg/Lwith a detection limit of 1 µg/L. The analysis of biological, food, and vegetable samples using the suggested method were found to be in tremendous accord with those acquired by Atomic Absorption Spectroscopy (AAS) and Inductively Coupled Plasma-Optical Emission Spectroscopy (ICP-OES). The method has high precision and accuracy (s = ±0.01 for 0.5 mg/L). The limit of quantification of the proposed method was 10 µg/L.
- Open Access
- 10 January 2020
- Published by Springer Nature in Analytical Sciences
- Vol. 36 (7) , 813-819
A Rapid Spectrofluorometric Method for the Determination of Aluminum at Nano-trace Levels in Some Real, Environmental, Biological, Hemodialysis, Food, Pharmaceutical, and Soil Samples Using 2′,3,4′,5,7-Pentahydroxyflavone
Japan's largest platform for academic e-journals: J-STAGE is a full text database for reviewed academic papers published by Japanese societies
- 10 January 2020
- Published by Springer Nature in Analytical Sciences
- Vol. 36 (7) , 813-819
Open AccessA Rapid Spectrofluorometric Method for the Determination of Aluminum at Nano-trace Levels in Some Real, Environmental, Biological, Hemodialysis, Food, Pharmaceutical, and Soil Samples Using 2′,3,4′,5,7-Pentahydroxyflavone
Japan's largest platform for academic e-journals: J-STAGE is a full text database for reviewed academic papers published by Japanese societies
- 11 September 2019
- Published by Wiley in Journal of Surfactants and Detergents
- Vol. 23 (1) , 99-108
Study of the Antioxidative Properties of Several Amino Acid‐Type Surfactants and their Synergistic Effect in Mixed Micelle
Cysteine and methionine, two sulfur‐containing amino acids (AA), were introduced in their surfactant forms as potential antioxidants. The antioxidative (AOX) properties of lauroyl methionine (C12‐Met) and lauroyl cysteine (C12‐Cys) was investigated by means of the oxygen radical absorbance capacity assay. Both the surfactants exhibited excellent AOX behavior at the premicellar state and micellar medium. The AOX behavior was found to be comparable for both the surfactants at their premicellar states. However, in micellar medium, C12‐Met showed better AOX property than C12‐Cys. The AOX power of the surfactants was compared with other previously developed AA‐type surfactants. The order of the AOX power was found to be: C12‐tryptophan > C12‐tyrosine ≈ C12‐methionine ≈ C12‐cysteine > C12‐histidine at the premicellar state and C12‐tryptophan > C12‐tyrosine > C12‐methionine > C12‐cysteine > C12‐histidine at the micellar state. C12‐Cys displayed lower AOX property in micellar medium due to its dimer formation tendency. Based on the HPLC and UPLC‐Q‐TOF‐MS analysis, the dimer formation of C12‐Cys was found to be accelerated due to the micellar environment and results into negative synergistic effect on other aromatic AA‐type surfactants. However, the presence of C12‐His in the micellar solution of C12‐Cys resulted no synergistic effect due to stronger H‐bonding between the surfactants and resulting less dimer formation.
- 11 September 2019
- Published by Wiley in Journal of Surfactants and Detergents
- Vol. 23 (1) , 99-108
Study of the Antioxidative Properties of Several Amino Acid‐Type Surfactants and their Synergistic Effect in Mixed Micelle
Cysteine and methionine, two sulfur‐containing amino acids (AA), were introduced in their surfactant forms as potential antioxidants. The antioxidative (AOX) properties of lauroyl methionine (C12‐Met) and lauroyl cysteine (C12‐Cys) was investigated by means of the oxygen radical absorbance capacity assay. Both the surfactants exhibited excellent AOX behavior at the premicellar state and micellar medium. The AOX behavior was found to be comparable for both the surfactants at their premicellar states. However, in micellar medium, C12‐Met showed better AOX property than C12‐Cys. The AOX power of the surfactants was compared with other previously developed AA‐type surfactants. The order of the AOX power was found to be: C12‐tryptophan > C12‐tyrosine ≈ C12‐methionine ≈ C12‐cysteine > C12‐histidine at the premicellar state and C12‐tryptophan > C12‐tyrosine > C12‐methionine > C12‐cysteine > C12‐histidine at the micellar state. C12‐Cys displayed lower AOX property in micellar medium due to its dimer formation tendency. Based on the HPLC and UPLC‐Q‐TOF‐MS analysis, the dimer formation of C12‐Cys was found to be accelerated due to the micellar environment and results into negative synergistic effect on other aromatic AA‐type surfactants. However, the presence of C12‐His in the micellar solution of C12‐Cys resulted no synergistic effect due to stronger H‐bonding between the surfactants and resulting less dimer formation.