Gunawarman Gunawarman
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Gunawarman Gunawarman has a total of 61 co-authors. Here are the top co-authors by number of shared publications:
- Djong Hon Tjong
Universitas Andalas
5 shared publications Jon Affi
Mechanical Engineering Departement, Engineering Faculty, Universitas Andalas, Padang, Indonesia
5 shared publicationsJ Affi
Mechanical Engineering Department, Universitas Andalas, Padang, Indonesia
4 shared publicationsN F Nuswantoro
Biomedical Science Department, Faculty of Medicine, Universitas Andalas, Padang, Indonesia
4 shared publicationsY Yetri
Mechanical Engineering Department, Politeknik Negeri Padang, Indonesia
4 shared publications- Yuli Yetri
Politeknik Negeri Padang
4 shared publications
Latest Publications
- Open Access
- 30 April 2025
- Published by Universitas Andalas in METAL: Jurnal Sistem Mekanik dan Termal
- Vol. 9 (1) , 14-20
Synthesis and Characterization of Hydroxyapatite Derived from Pleco Fish (Hypostomus Plecostomus) Bone Waste via Calcination and Ball Milling for Biomedical Applications
Hydroxyapatite (HA), a calcium phosphate-based bioceramic, is widely recognized for its excellent biocompatibility and bioactivity, making it suitable for biomedical applications. This study aims to synthesize HA from waste bones of the pleco fish (Hypostomus plecostomus), a natural source of calcium and phosphate that is underutilized in West Sumatera. The synthesis was conducted through calcination at 900 °C followed by mechanical refinement using ball milling for 3, 6, and 9 hours. X-ray diffraction (XRD) analysis confirmed the formation of crystalline HA with dominant peaks at 25.9°; 31.8°; and 32.9°, which remained stable across all milling durations.
- 30 April 2025
- Published by Universitas Andalas in METAL: Jurnal Sistem Mekanik dan Termal
- Vol. 9 (1) , 14-20
Open AccessSynthesis and Characterization of Hydroxyapatite Derived from Pleco Fish (Hypostomus Plecostomus) Bone Waste via Calcination and Ball Milling for Biomedical Applications
Hydroxyapatite (HA), a calcium phosphate-based bioceramic, is widely recognized for its excellent biocompatibility and bioactivity, making it suitable for biomedical applications. This study aims to synthesize HA from waste bones of the pleco fish (Hypostomus plecostomus), a natural source of calcium and phosphate that is underutilized in West Sumatera. The synthesis was conducted through calcination at 900 °C followed by mechanical refinement using ball milling for 3, 6, and 9 hours. X-ray diffraction (XRD) analysis confirmed the formation of crystalline HA with dominant peaks at 25.9°; 31.8°; and 32.9°, which remained stable across all milling durations.
- 1 January 2024
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2891 (1) , 080022
The effect of ball variations in ball milling process and heating on calcium content of freshwater snail shells (sulcospira) powder
This study aims to obtain substitute material for metal-based bone implants. Apart from several biocompatibility challenges, the metal implant procedure require This study aims to obtain substitute material for metal-based bone implants. Apart from several biocompatibility challenges, the metal implant procedure require
- 1 January 2024
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2891 (1) , 080022
The effect of ball variations in ball milling process and heating on calcium content of freshwater snail shells (sulcospira) powder
This study aims to obtain substitute material for metal-based bone implants. Apart from several biocompatibility challenges, the metal implant procedure require This study aims to obtain substitute material for metal-based bone implants. Apart from several biocompatibility challenges, the metal implant procedure require
- Open Access
- 1 January 2024
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2891 (1) , 080020
Effect of type and number of grinding balls on physical characteristics of chicken egg shells powder using ball mill
Bio-ceramic powder from chicken egg shells has been made using a planetary ball mill with varied numbers and types of grinding balls and gradual heating. Chicke Bio-ceramic powder from chicken egg shells has been made using a planetary ball mill with varied numbers and types of grinding balls and gradual heating. Chicke
- 1 January 2024
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2891 (1) , 080020
Open AccessEffect of type and number of grinding balls on physical characteristics of chicken egg shells powder using ball mill
Bio-ceramic powder from chicken egg shells has been made using a planetary ball mill with varied numbers and types of grinding balls and gradual heating. Chicke Bio-ceramic powder from chicken egg shells has been made using a planetary ball mill with varied numbers and types of grinding balls and gradual heating. Chicke
- Open Access
- 26 September 2023
- Published by Universiti Malaysia Pahang Al-Sultan Abdullah Press (UMPSA Press) in International Journal of Automotive and Mechanical Engineering
- Vol. 20 (3) , 10777-10785
Effect of Bilayer Nano-Micro Hydroxyapatite on the Surface Characteristics of Implanted Ti-6Al-4V ELI
Ti-6Al-4V ELI is a well-known, popular medical-grade titanium alloy due to its biocompatibility and excellent mechanical properties. However, like other metal implants, it is less bioactive that affects tissue regeneration around the implant, and may lead to implant failure. So, a bioactive substance such as hydroxyapatite (HA) has usually been coated on metal implants to improve its bioactive properties. However, a single layer of HA was reported to be dissolved into body fluid after a long time of exposure in the human body. In this study, bilayer HA was deposited on the surface of screw-type implants made of Ti-6Al-4V ELI through electrophoretic deposition (EPD method. The bottom layer consists of micro-size of HA, and the second layer contains nano-size HA. The suspension contains each micro and nano size of HA powder was homogenized for 1 h followed by sonication for 2 h using a magnetic stirrer. The coating layer was subsequently sintered at 700oC for 1 h. The bilayer-coated screw implant was then implanted into the proximal tibia of health rattus novergicus under proper surgical procedures. Some screws without HA deposition were also implanted into rattus novergicus for comparison. The implanted screws were then taken out via surgery after 2, 3 and 4 weeks, and they were subsequently observed by optical microscope, SEM and XRF. The results showed that organic material is found on each coated specimen, and few HA layer is disintegrated from the surface of the screw. The disintegrated HA remained in the surface of the screw, and the amount of HA increased with increasing implantation time, which indicates the increase of osseointegration between the bone and HA layer. XRF showed a significant difference in Ti and titanium oxide contents on the surface of the coated samples and the non-coted ones, where it is only 0.66%Ti (0.39% TiO2) on the surface of the screw with HA layer and 70%Ti (67% TiO2) for without HA. When TiO2 is formed as a fast self-healing reaction while the screw is exposed to body fluid, the HA acts as an interface against body fluid that may contain aggressive ions. So, HA layer is not only effective against corrosion attack but also inhibits the formation of TiO2 on the implant surface. The coated screws also revealed a strong bonding between the HA layer and the surface of the implant screw. Besides, the ratio between Ca and P elements on the screw surface is in the range of 0.58 – 2.04, which is in the range of bone characteristics.
- 26 September 2023
- Published by Universiti Malaysia Pahang Al-Sultan Abdullah Press (UMPSA Press) in International Journal of Automotive and Mechanical Engineering
- Vol. 20 (3) , 10777-10785
Open AccessEffect of Bilayer Nano-Micro Hydroxyapatite on the Surface Characteristics of Implanted Ti-6Al-4V ELI
Ti-6Al-4V ELI is a well-known, popular medical-grade titanium alloy due to its biocompatibility and excellent mechanical properties. However, like other metal implants, it is less bioactive that affects tissue regeneration around the implant, and may lead to implant failure. So, a bioactive substance such as hydroxyapatite (HA) has usually been coated on metal implants to improve its bioactive properties. However, a single layer of HA was reported to be dissolved into body fluid after a long time of exposure in the human body. In this study, bilayer HA was deposited on the surface of screw-type implants made of Ti-6Al-4V ELI through electrophoretic deposition (EPD method. The bottom layer consists of micro-size of HA, and the second layer contains nano-size HA. The suspension contains each micro and nano size of HA powder was homogenized for 1 h followed by sonication for 2 h using a magnetic stirrer. The coating layer was subsequently sintered at 700oC for 1 h. The bilayer-coated screw implant was then implanted into the proximal tibia of health rattus novergicus under proper surgical procedures. Some screws without HA deposition were also implanted into rattus novergicus for comparison. The implanted screws were then taken out via surgery after 2, 3 and 4 weeks, and they were subsequently observed by optical microscope, SEM and XRF. The results showed that organic material is found on each coated specimen, and few HA layer is disintegrated from the surface of the screw. The disintegrated HA remained in the surface of the screw, and the amount of HA increased with increasing implantation time, which indicates the increase of osseointegration between the bone and HA layer. XRF showed a significant difference in Ti and titanium oxide contents on the surface of the coated samples and the non-coted ones, where it is only 0.66%Ti (0.39% TiO2) on the surface of the screw with HA layer and 70%Ti (67% TiO2) for without HA. When TiO2 is formed as a fast self-healing reaction while the screw is exposed to body fluid, the HA acts as an interface against body fluid that may contain aggressive ions. So, HA layer is not only effective against corrosion attack but also inhibits the formation of TiO2 on the implant surface. The coated screws also revealed a strong bonding between the HA layer and the surface of the implant screw. Besides, the ratio between Ca and P elements on the screw surface is in the range of 0.58 – 2.04, which is in the range of bone characteristics.
- 14 February 2023
- Published by Trans Tech Publications, Ltd. in Journal of Biomimetics, Biomaterials and Biomedical Engineering
- Vol. 59, 81-89
Improvement in Bioactivity Properties of Hydroxyapatite Coated Ti-6Al-4V ELI with Addition of Zirconium Oxide for Orthopaedic Implant
One of factor causing the failure of Ti-6Al-4V Extra Low Interstitial (ELI)-based material implants, does not have bioactive properties in the implantation process, thus not supporting the osseointegration process in the body. For this reason, coating with hydroxyapatite (HA) suspension is necessary. This research used the dip-coating method and added Zirconium Oxide (ZrO2) into nanosized commercial HA to be suspensions (17%wt and 20%wt) to strengthen the adhesion of the coating. The specimens were heated at 800, 900, and 950°C to densify the layers. Bioactivity increased along with the increasing calcium/phosphate (Ca/P) ratio of the HA layers in the test specimens. The specimens were immersed in Simulated Body Fluid (SBF), namely Hank’s Solution, for 1, 2, 3, and 4 weeks. ZrO2 added to the HA suspensions of Ti-6Al-4V ELI can increase the Ca/P ratio from 1.51 in the first immersion week to 1.62 in the fourth. The bioactivity level is also proven by the accumulation of calcium and phosphate on the surface of the coating. The Ca/P value close to the Ca/P ratio of HA of 1.67 is good for improving the osseointegration process in the body.
- 14 February 2023
- Published by Trans Tech Publications, Ltd. in Journal of Biomimetics, Biomaterials and Biomedical Engineering
- Vol. 59, 81-89
Improvement in Bioactivity Properties of Hydroxyapatite Coated Ti-6Al-4V ELI with Addition of Zirconium Oxide for Orthopaedic Implant
One of factor causing the failure of Ti-6Al-4V Extra Low Interstitial (ELI)-based material implants, does not have bioactive properties in the implantation process, thus not supporting the osseointegration process in the body. For this reason, coating with hydroxyapatite (HA) suspension is necessary. This research used the dip-coating method and added Zirconium Oxide (ZrO2) into nanosized commercial HA to be suspensions (17%wt and 20%wt) to strengthen the adhesion of the coating. The specimens were heated at 800, 900, and 950°C to densify the layers. Bioactivity increased along with the increasing calcium/phosphate (Ca/P) ratio of the HA layers in the test specimens. The specimens were immersed in Simulated Body Fluid (SBF), namely Hank’s Solution, for 1, 2, 3, and 4 weeks. ZrO2 added to the HA suspensions of Ti-6Al-4V ELI can increase the Ca/P ratio from 1.51 in the first immersion week to 1.62 in the fourth. The bioactivity level is also proven by the accumulation of calcium and phosphate on the surface of the coating. The Ca/P value close to the Ca/P ratio of HA of 1.67 is good for improving the osseointegration process in the body.
- Open Access
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2592 (1)
Evaluation of KOH activator concentration variation on the physical properties of supercapacitor electrodes from activated carbon of cocoa pods
The study of preparing cocoa pods activated carbon which will be used as supercapacitor electrodes has been successfully made with Potassium hydroxide (KOH) 0.3 and 0.4 mol/L activators at 700oC. Electrodes of activated carbon are made by a combination of chemical and activation methods. Physical properties were analyzed by measuring the density and dimensional, diffraction of X-Ray (XRD), and Scanning Electron Microscopy (SEM). The technique of preparing carbon electrodes started from pre-carbonization, milling, chemical activation, pellet making, carbonization, and physical activation. Analysis of dimensions, and density in the manufacture of carbon electrodes showed the diameter (d), mass (m), density (ρ), and thickness (t) of the electrodes decreased along with the addition of Potassium hydroxide concentration from 0.3 to 0.4 mol/L. XRD measurement data obtaining the values of 2θ in the range of 23.569o-24.747o for the reflection plane 002, and 44.634o-44.781o for the reflection plane 100. Diffraction X-ray curve analysis indicate that the sample 0.4 mol/L 700oC has a smaller microcrystalline dimension height (Lc) measure and distance of lattice than the 0.3 mol/L 700oC sample, so it can be showed that the area of surface of the 0.4 mol/L700oC is bigger sample than the 0.3 mol/L 700oC. With an increase in the sample surface area, there is an indication that the activated carbon of cocoa pods can be used as a supercapacitor electrode as a renewable energy source.
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2592 (1)
Open AccessEvaluation of KOH activator concentration variation on the physical properties of supercapacitor electrodes from activated carbon of cocoa pods
The study of preparing cocoa pods activated carbon which will be used as supercapacitor electrodes has been successfully made with Potassium hydroxide (KOH) 0.3 and 0.4 mol/L activators at 700oC. Electrodes of activated carbon are made by a combination of chemical and activation methods. Physical properties were analyzed by measuring the density and dimensional, diffraction of X-Ray (XRD), and Scanning Electron Microscopy (SEM). The technique of preparing carbon electrodes started from pre-carbonization, milling, chemical activation, pellet making, carbonization, and physical activation. Analysis of dimensions, and density in the manufacture of carbon electrodes showed the diameter (d), mass (m), density (ρ), and thickness (t) of the electrodes decreased along with the addition of Potassium hydroxide concentration from 0.3 to 0.4 mol/L. XRD measurement data obtaining the values of 2θ in the range of 23.569o-24.747o for the reflection plane 002, and 44.634o-44.781o for the reflection plane 100. Diffraction X-ray curve analysis indicate that the sample 0.4 mol/L 700oC has a smaller microcrystalline dimension height (Lc) measure and distance of lattice than the 0.3 mol/L 700oC sample, so it can be showed that the area of surface of the 0.4 mol/L700oC is bigger sample than the 0.3 mol/L 700oC. With an increase in the sample surface area, there is an indication that the activated carbon of cocoa pods can be used as a supercapacitor electrode as a renewable energy source.
- Open Access
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2592 (1) , 050006
Zirconium oxide contribution for cracking reduction of the hydroxyapatite-based coating layer on Ti-6AL-4V ELI surface through dip-coating method
Ti-6Al-4V Extra Low Interstitials (ELI) is one of the most widely used titanium alloys for orthodontic and orthopedic implants. However, several studies reveale
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2592 (1) , 050006
Open AccessZirconium oxide contribution for cracking reduction of the hydroxyapatite-based coating layer on Ti-6AL-4V ELI surface through dip-coating method
Ti-6Al-4V Extra Low Interstitials (ELI) is one of the most widely used titanium alloys for orthodontic and orthopedic implants. However, several studies reveale
- Open Access
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2592 (1) , 030012
Contribution of hydroxyapatite layer on corrosion and bioactivity properties of Ti-12Cr in simulated body fluid
Biomaterial implant is a material use for biomedical applications such as for fixing bone fractures. One of materials used in this application is titanium and i
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2592 (1) , 030012
Open AccessContribution of hydroxyapatite layer on corrosion and bioactivity properties of Ti-12Cr in simulated body fluid
Biomaterial implant is a material use for biomedical applications such as for fixing bone fractures. One of materials used in this application is titanium and i
- Open Access
- 31 October 2022
- Published by Universitas Andalas in METAL: Jurnal Sistem Mekanik dan Termal
- Vol. 6 (2) , 95-101
Addition of Zirconium Oxide for Reduction of Hydroxyapatite Layer Cracks in Ti-6Al-4V ELI Implant Materials for Improved Osseointegration
The hydroxyapatite (HA) layer on the surface of the implant material tends to crack during the sintering process for layer densification. This causes the process of implant union with bone (osseointegration) does not function perfectly in the human body. This study aims to reduce cracking by increasing the adhesion of the HA layer on the surface of the Ti-6Al-4V Extra Low Intertitial (ELI) implant material. The research used the dip coating method to get a thin and even layer. To strengthen the adhesion of the coating, Zirconium Oxide (ZrO2) was added in commercial HA suspension. The test specimens were heated at sintering temperatures of 800 0C, 900 0C and 950 0C with a heating rate of 5 0C /minute. Layer morphology and cracks were seen using an optical microscope. The percentage of layer cracks will be measured using ImageJ software. The results obtained, the addition of ZrO2 can reduce cracks in the HA layer of the surface of the test specimen. The percentage of cracks decrease with the addition of ZrO2 (17% and 20% weight) to the suspension of the HA layer. These result is certainly good for increasing osseointegration in the human body.
- 31 October 2022
- Published by Universitas Andalas in METAL: Jurnal Sistem Mekanik dan Termal
- Vol. 6 (2) , 95-101
Open AccessAddition of Zirconium Oxide for Reduction of Hydroxyapatite Layer Cracks in Ti-6Al-4V ELI Implant Materials for Improved Osseointegration
The hydroxyapatite (HA) layer on the surface of the implant material tends to crack during the sintering process for layer densification. This causes the process of implant union with bone (osseointegration) does not function perfectly in the human body. This study aims to reduce cracking by increasing the adhesion of the HA layer on the surface of the Ti-6Al-4V Extra Low Intertitial (ELI) implant material. The research used the dip coating method to get a thin and even layer. To strengthen the adhesion of the coating, Zirconium Oxide (ZrO2) was added in commercial HA suspension. The test specimens were heated at sintering temperatures of 800 0C, 900 0C and 950 0C with a heating rate of 5 0C /minute. Layer morphology and cracks were seen using an optical microscope. The percentage of layer cracks will be measured using ImageJ software. The results obtained, the addition of ZrO2 can reduce cracks in the HA layer of the surface of the test specimen. The percentage of cracks decrease with the addition of ZrO2 (17% and 20% weight) to the suspension of the HA layer. These result is certainly good for increasing osseointegration in the human body.