Chi-Chang Lin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Chi-Chang Lin has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
Jer-Fu Wang
Department of Civil and Disaster Prevention Engineering, National United University, Miao-Li, Taiwan
4 shared publications- Ging-Long Lin
National Kaohsiung University of Science and Technology
3 shared publications Ging-Long Lin
Department of Construction Engineering, National Kaohsiung University of Science and Technology, Kaohsiung, Taiwan
2 shared publicationsC. Lee
National Taiwan Univ., Taipei
1 shared publicationChang-Ching Chang
1 shared publication- Chien-Chung Kuo
Department of Orthopedics, China Medical University Hospital, Taichung, Taiwan
1 shared publication
Latest Publications
- 24 August 2024
- Published by Elsevier in Journal of Sound and Vibration
- Vol. 595, 118698
Experimental investigation of an electromagnetic seismic isolation system with different configurations of inertance
- 24 August 2024
- Published by Elsevier in Journal of Sound and Vibration
- Vol. 595, 118698
Experimental investigation of an electromagnetic seismic isolation system with different configurations of inertance
- 28 August 2021
- Published by SAGE Publications in Journal of Vibration and Control
- Vol. 28 (23-24) , 3875-3889
Optimum placement and design of multiple tuned mass dampers for vibration control of asymmetric buildings
This study proposed a design procedure to determine the optimal location, moving direction, and system parameters of multiple tuned mass dampers systematically for vibration control of asymmetric buildings under dynamic loadings such as earthquake or wind excitations. A piece of computer software was developed as a postprocessor of any commercial structural analysis programs, such as ETABS, SAP2000, and so on. First, the modal parameters of target building structure were extracted from its finite element model. The optimum location and moving direction of the multiple tuned mass dampers system are determined based on the controlled mode shapes and both modal participating mass ratio and modal direction factor. Then, the optimal parameters of the multiple tuned mass dampers system were calculated by minimizing the mean square modal displacement response ratio of the controlled mode for the target building with and without multiple tuned mass dampers system. To evaluate control effectiveness, the responses of the building with and without multiple tuned mass dampers system were compared in both frequency and time domains. The analysis results from a 5-story building with different torsion-coupling degrees and a 46-story real building show that the proposed multiple tuned mass dampers system is quite effective in mitigating excessive floor vibration, base shear, and elapsed time of vibration due to earthquake excitations to enhance both structural safety and resident comfort. It is also concluded that the torsion-coupling effect should be considered in determining the optimum planar location of multiple tuned mass dampers system which is equivalent to mass increase of the multiple tuned mass dampers system and thus improves the control efficacy for asymmetric buildings.
- 28 August 2021
- Published by SAGE Publications in Journal of Vibration and Control
- Vol. 28 (23-24) , 3875-3889
Optimum placement and design of multiple tuned mass dampers for vibration control of asymmetric buildings
This study proposed a design procedure to determine the optimal location, moving direction, and system parameters of multiple tuned mass dampers systematically for vibration control of asymmetric buildings under dynamic loadings such as earthquake or wind excitations. A piece of computer software was developed as a postprocessor of any commercial structural analysis programs, such as ETABS, SAP2000, and so on. First, the modal parameters of target building structure were extracted from its finite element model. The optimum location and moving direction of the multiple tuned mass dampers system are determined based on the controlled mode shapes and both modal participating mass ratio and modal direction factor. Then, the optimal parameters of the multiple tuned mass dampers system were calculated by minimizing the mean square modal displacement response ratio of the controlled mode for the target building with and without multiple tuned mass dampers system. To evaluate control effectiveness, the responses of the building with and without multiple tuned mass dampers system were compared in both frequency and time domains. The analysis results from a 5-story building with different torsion-coupling degrees and a 46-story real building show that the proposed multiple tuned mass dampers system is quite effective in mitigating excessive floor vibration, base shear, and elapsed time of vibration due to earthquake excitations to enhance both structural safety and resident comfort. It is also concluded that the torsion-coupling effect should be considered in determining the optimum planar location of multiple tuned mass dampers system which is equivalent to mass increase of the multiple tuned mass dampers system and thus improves the control efficacy for asymmetric buildings.
- 4 September 2019
- Published by SAGE Publications in Advances in Structural Engineering
- Vol. 22 (16) , 3544-3557
A novel rapid screening method for health monitoring of building structures from earthquake records
This study presents a rapid screening method for health monitoring of building structures based on earthquake records. Compared with conventional damage detection techniques, the rapid screening system with few sensors is more attractive and cost-effective in assessing the global behaviors of a building structure. Only two tri-axial accelerometers are required for a building. One is mounted at the ground level, and another one is mounted at the top floor. First, the relative displacement of top floor to ground is calculated by on-line integration. Then, the diagram of absolute acceleration versus relative displacement of top floor is used to determine the pseudo stiffness of the whole building by linear regression. The decrease of pseudo stiffness denotes the occurrence and degree of damage in the building. A novel real-time damage technique is also proposed to detect nonlinear behavior of a building. A five-story shear-type building under earthquake excitations was illustrated for sensitivity analysis of pseudo stiffness considering different damage cases. Shaking-table-test data of a three-story benchmark building were used to verify the accuracy of the proposed damage assessment technique. In addition, the proposed method was also applied to evaluate a new eight-story residential building equipped with accelerometers in Taipei, Taiwan. Finally, the acceleration response records of a real building, which experienced moderate damages caused by the main shock of 1999 Taiwan Chi-Chi earthquake ( M L = 7.3), were considered to examine the applicability of the proposed method to generate a real-time damage indicator for a building with nonlinear behavior. All of the results show that the proposed method is reliable and effective for rapid diagnosis of building health.
- 4 September 2019
- Published by SAGE Publications in Advances in Structural Engineering
- Vol. 22 (16) , 3544-3557
A novel rapid screening method for health monitoring of building structures from earthquake records
This study presents a rapid screening method for health monitoring of building structures based on earthquake records. Compared with conventional damage detection techniques, the rapid screening system with few sensors is more attractive and cost-effective in assessing the global behaviors of a building structure. Only two tri-axial accelerometers are required for a building. One is mounted at the ground level, and another one is mounted at the top floor. First, the relative displacement of top floor to ground is calculated by on-line integration. Then, the diagram of absolute acceleration versus relative displacement of top floor is used to determine the pseudo stiffness of the whole building by linear regression. The decrease of pseudo stiffness denotes the occurrence and degree of damage in the building. A novel real-time damage technique is also proposed to detect nonlinear behavior of a building. A five-story shear-type building under earthquake excitations was illustrated for sensitivity analysis of pseudo stiffness considering different damage cases. Shaking-table-test data of a three-story benchmark building were used to verify the accuracy of the proposed damage assessment technique. In addition, the proposed method was also applied to evaluate a new eight-story residential building equipped with accelerometers in Taipei, Taiwan. Finally, the acceleration response records of a real building, which experienced moderate damages caused by the main shock of 1999 Taiwan Chi-Chi earthquake ( M L = 7.3), were considered to examine the applicability of the proposed method to generate a real-time damage indicator for a building with nonlinear behavior. All of the results show that the proposed method is reliable and effective for rapid diagnosis of building health.
- 8 January 2017
- Published by World Scientific Pub Co Pte Ltd in International Journal of Structural Stability and Dynamics
- Vol. 17 (01) , 1750002
Robust Design Strategy for Multiple Tuned Mass Dampers with Consideration of Frequency Bandwidth
The tuned mass damper (TMD) has been widely used in vibration control of civil engineering structures after numerous analytical studies and experimental verifications. A large number of TMDs have been implemented in real structures against natural and man-made excitations since the early 1970. From field observations, it was found that the control efficacy of a TMD may decay significantly when its frequency is not well tuned to the desired value. A multiple TMD (MTMD) system was proposed to tune a band of frequencies, thereby enhancing the vibration control efficiency. Frequency detuning usually results from structural system variations due to errors in modeling, construction, and system parameter identification. In this study, the frequency detuning effect due to uncertainties of the controlled system parameters on the performance of the MTMDs is investigated. A sensitivity analysis was first carried out to evaluate the control effectiveness of a MTMD system designed by a conventional method. A new robust design method with account taken of frequency bandwidth is proposed to alleviate the detuning effect. Numerical analysis is performed to verify the applicability and efficacy of the proposed robust design method.
- 8 January 2017
- Published by World Scientific Pub Co Pte Ltd in International Journal of Structural Stability and Dynamics
- Vol. 17 (01) , 1750002
Robust Design Strategy for Multiple Tuned Mass Dampers with Consideration of Frequency Bandwidth
The tuned mass damper (TMD) has been widely used in vibration control of civil engineering structures after numerous analytical studies and experimental verifications. A large number of TMDs have been implemented in real structures against natural and man-made excitations since the early 1970. From field observations, it was found that the control efficacy of a TMD may decay significantly when its frequency is not well tuned to the desired value. A multiple TMD (MTMD) system was proposed to tune a band of frequencies, thereby enhancing the vibration control efficiency. Frequency detuning usually results from structural system variations due to errors in modeling, construction, and system parameter identification. In this study, the frequency detuning effect due to uncertainties of the controlled system parameters on the performance of the MTMDs is investigated. A sensitivity analysis was first carried out to evaluate the control effectiveness of a MTMD system designed by a conventional method. A new robust design method with account taken of frequency bandwidth is proposed to alleviate the detuning effect. Numerical analysis is performed to verify the applicability and efficacy of the proposed robust design method.
- 5 February 2013
- Published by IGI Global Scientific Publishing
- p. 126-149
Optimal Design and Practical Considerations of Tuned Mass Dampers for Structural Control
The design concept and procedure for tuned mass dampers (TMDs) have been extensively investigated through numerical simulation analyses and experimental tests. Sophisticated three-dimensional building models were developed to examine the optimum installation location in elevation and in plane, number and movement direction of the TMDs with the consideration of translation-torsion coupling and soil-structure interaction effects. Analytical and empirical formulas were also derived to determine the optimal parameters of TMD. It is well recognized that the performance of a TMD is sensitive to the slight deviation of frequency ratio between the TMD and the structure. Multiple tuned mass dampers (MTMDs) were proposed to reduce this detuning effect. It is also recognized that TMD’s performance relies on its large stroke which may not be allowed due to the limitation of space and vibration components. The authors presented a two-stage optimum design procedure for MTMDs with limitation of their strokes. New invention patents both in Taiwan and in USA have been granted for the MTMD device.
- 5 February 2013
- Published by IGI Global Scientific Publishing
- p. 126-149
Optimal Design and Practical Considerations of Tuned Mass Dampers for Structural Control
The design concept and procedure for tuned mass dampers (TMDs) have been extensively investigated through numerical simulation analyses and experimental tests. Sophisticated three-dimensional building models were developed to examine the optimum installation location in elevation and in plane, number and movement direction of the TMDs with the consideration of translation-torsion coupling and soil-structure interaction effects. Analytical and empirical formulas were also derived to determine the optimal parameters of TMD. It is well recognized that the performance of a TMD is sensitive to the slight deviation of frequency ratio between the TMD and the structure. Multiple tuned mass dampers (MTMDs) were proposed to reduce this detuning effect. It is also recognized that TMD’s performance relies on its large stroke which may not be allowed due to the limitation of space and vibration components. The authors presented a two-stage optimum design procedure for MTMDs with limitation of their strokes. New invention patents both in Taiwan and in USA have been granted for the MTMD device.
- 13 December 2012
- Published by Wiley in British Journal of Educational Technology
- Vol. 45 (1) , 125-135
Identification of dysfunctional cooperative learning teams and troubled individuals
In cooperative learning, students work together as a team to maximize the academic success of all the team members. The failure of even a single member can compromise the success of the entire team. Thus, to evaluate the functioning of the team reliably, it is necessary to consider both the performance of the individual team members and the interactions among them. In this study, a method was developed for identifying dysfunctional teams and troubled individuals by examining the correlation between the team scores obtained in sequential tests and the correlation between the scores obtained by the different team members. The effectiveness of the proposed method was evaluated via field experiments. Forty‐eight students were randomly assigned to cooperative learning teams and their learning performance assessed by four‐unit tests. The results indicated that the proposed method can identify the most troubled individuals in a team even when the team performance/grouping information is not taken explicitly into account. Furthermore, when the team information is considered, the method can identify both the dysfunctional teams and the troubled individuals within the teams. Therefore, the proposed method provides a useful basis for the development of computer‐assisted solutions for assessing the performance of cooperative learning teams.
- 13 December 2012
- Published by Wiley in British Journal of Educational Technology
- Vol. 45 (1) , 125-135
Identification of dysfunctional cooperative learning teams and troubled individuals
In cooperative learning, students work together as a team to maximize the academic success of all the team members. The failure of even a single member can compromise the success of the entire team. Thus, to evaluate the functioning of the team reliably, it is necessary to consider both the performance of the individual team members and the interactions among them. In this study, a method was developed for identifying dysfunctional teams and troubled individuals by examining the correlation between the team scores obtained in sequential tests and the correlation between the scores obtained by the different team members. The effectiveness of the proposed method was evaluated via field experiments. Forty‐eight students were randomly assigned to cooperative learning teams and their learning performance assessed by four‐unit tests. The results indicated that the proposed method can identify the most troubled individuals in a team even when the team performance/grouping information is not taken explicitly into account. Furthermore, when the team information is considered, the method can identify both the dysfunctional teams and the troubled individuals within the teams. Therefore, the proposed method provides a useful basis for the development of computer‐assisted solutions for assessing the performance of cooperative learning teams.
- 1 January 2009
- Published by ASME International
- p. 279-287
Protection of Seismic Structures Using Passive and Semi-Active Friction Typed Multiple Tuned Mass Dampers
Although the design and applications of linear tuned mass damper (TMD) systems are well developed, nonlinear TMD systems are still developing. In this paper, the application of multiple semi-active friction tuned mass dampers (SAF-MTMD) for response control of a multistory structure under seismic excitation is investigated. The friction forces of the SAF-MTMD are controllable. A non-sticking friction (NSF) controller, which is able to keep each of the TMD activated and in its slip state throughout an earthquake with arbitrary intensity, was conducted. A parametric study is performed to investigate the effectiveness of SAF-MTMD. The seismic performance of the SAF-MTMD is also compared with the single and multiple passive friction tuned mass dampers (PF-TMD/PF-MTMD). The numerical result shows that the SAF-MTMD is superior to PF-MTMD in reducing the response of the primary structure under the seismic excitation.
- 1 January 2009
- Published by ASME International
- p. 279-287
Protection of Seismic Structures Using Passive and Semi-Active Friction Typed Multiple Tuned Mass Dampers
Although the design and applications of linear tuned mass damper (TMD) systems are well developed, nonlinear TMD systems are still developing. In this paper, the application of multiple semi-active friction tuned mass dampers (SAF-MTMD) for response control of a multistory structure under seismic excitation is investigated. The friction forces of the SAF-MTMD are controllable. A non-sticking friction (NSF) controller, which is able to keep each of the TMD activated and in its slip state throughout an earthquake with arbitrary intensity, was conducted. A parametric study is performed to investigate the effectiveness of SAF-MTMD. The seismic performance of the SAF-MTMD is also compared with the single and multiple passive friction tuned mass dampers (PF-TMD/PF-MTMD). The numerical result shows that the SAF-MTMD is superior to PF-MTMD in reducing the response of the primary structure under the seismic excitation.