Koichi Kurita
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Koichi Kurita has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
Etsuro Hirai
2 shared publicationsHisashi Tanaka
2 shared publicationsK. Takiyama
2 shared publicationsKen Takiyama
Department of Applied Physics and Chemistry, Faculty of Engineering, Hiroshima University
2 shared publicationsKoji Teshima
2 shared publicationsMichiaki Oyado
2 shared publications
Latest Publications
- 18 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (11) , 17817-17824
Noncontact Measurement Technique for Simulated Hemiplegia Walking Motion Using Ultrahigh Sensitive Electrostatic Induction Sensor
In this study, simulated hemiplegia gait is detected by using a method that detects the subject’s walking motion without attaching a sensor to the subject. To detect walking motion without contacting or wearing the human body, attention has been focused on the fluctuations in human body potential associated with walking motion. Walking motion is detected under noncontact conditions by installing an ultra-sensitive electrostatic induction current sensor near a walking subject and detecting changes in human body potential caused by the subject’s walking motion. In this study, to simulate gait disorders, ankle weights of different weights are attached to the right ankle of a healthy subject, and the electrostatic induction current waveforms induced by the walking movements of four tasks are measured without contact. A scalogram is obtained by wavelet transforming the electrostatic induction current waveform induced by this walking motion. By using these scalograms as training data for deep learning, a learning model was constructed that can detect the inconvenience of a subject’s walking motion. Convolutional neural network (CNN) and long short-term memory (LSTM) are used for deep learning. The results showed that when CNN and LSTM are used for deep learning classification, the average classification accuracy rate of both methods is approximately 80%. The results of this study reveal that when hemiplegia causes asymmetry in walking movement, it is possible to easily detect the degree of lameness of hemiplegia without attaching a sensor to the subject.
- 18 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (11) , 17817-17824
Noncontact Measurement Technique for Simulated Hemiplegia Walking Motion Using Ultrahigh Sensitive Electrostatic Induction Sensor
In this study, simulated hemiplegia gait is detected by using a method that detects the subject’s walking motion without attaching a sensor to the subject. To detect walking motion without contacting or wearing the human body, attention has been focused on the fluctuations in human body potential associated with walking motion. Walking motion is detected under noncontact conditions by installing an ultra-sensitive electrostatic induction current sensor near a walking subject and detecting changes in human body potential caused by the subject’s walking motion. In this study, to simulate gait disorders, ankle weights of different weights are attached to the right ankle of a healthy subject, and the electrostatic induction current waveforms induced by the walking movements of four tasks are measured without contact. A scalogram is obtained by wavelet transforming the electrostatic induction current waveform induced by this walking motion. By using these scalograms as training data for deep learning, a learning model was constructed that can detect the inconvenience of a subject’s walking motion. Convolutional neural network (CNN) and long short-term memory (LSTM) are used for deep learning. The results showed that when CNN and LSTM are used for deep learning classification, the average classification accuracy rate of both methods is approximately 80%. The results of this study reveal that when hemiplegia causes asymmetry in walking movement, it is possible to easily detect the degree of lameness of hemiplegia without attaching a sensor to the subject.
- Open Access
A Non-Contact and Real-Time Measurement Technique of Human Body Potential Using Electrostatic Induction Current Accompanied by Human Body Motion
This paper describes a non-contact and real-time measurement technique of human body potential using ultra-sensitive electrostatic induction. When a participant moves his/her palm to a position approximately 30 cm away from an electrostatic induction sensor, electrostatic induction current flows transiently. It is clarified whether estimation of the human body potential is possible by simultaneously measuring the velocity of the participant’s palm and distance between the participant’s palm and sensor. In addition, even when the participant walks at a position approximately 50 cm away from the electrostatic induction sensor, it is confirmed that the estimation of human body potential is possible.
Open AccessA Non-Contact and Real-Time Measurement Technique of Human Body Potential Using Electrostatic Induction Current Accompanied by Human Body Motion
This paper describes a non-contact and real-time measurement technique of human body potential using ultra-sensitive electrostatic induction. When a participant moves his/her palm to a position approximately 30 cm away from an electrostatic induction sensor, electrostatic induction current flows transiently. It is clarified whether estimation of the human body potential is possible by simultaneously measuring the velocity of the participant’s palm and distance between the participant’s palm and sensor. In addition, even when the participant walks at a position approximately 50 cm away from the electrostatic induction sensor, it is confirmed that the estimation of human body potential is possible.
- Open Access
- 24 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 139226-139235
Detection Technique of Individual Characteristic Appearing in Walking Motion
In this study, we develop a technique to measure walking under noncontact conditions by using an ultrahigh sensitivity electrostatic induction technique. The results of walking measurements using this technique indicate that the detected electrostatic-induced current waveform exhibits a peak at the time of foot contact or detachment owing to walking. Based on these results, we construct a theoretical model in which an induced current is generated, and the correspondence relationship between walking and electrostatic-induced current is revealed. Furthermore, when comparing the walking signals of each participant, we used a scalogram obtained by performing a wavelet transformation on the walking signal. Person identification was attempted by learning the participant’s scalogram using a convolutional neural network (CNN).
- 24 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 139226-139235
Open AccessDetection Technique of Individual Characteristic Appearing in Walking Motion
In this study, we develop a technique to measure walking under noncontact conditions by using an ultrahigh sensitivity electrostatic induction technique. The results of walking measurements using this technique indicate that the detected electrostatic-induced current waveform exhibits a peak at the time of foot contact or detachment owing to walking. Based on these results, we construct a theoretical model in which an induced current is generated, and the correspondence relationship between walking and electrostatic-induced current is revealed. Furthermore, when comparing the walking signals of each participant, we used a scalogram obtained by performing a wavelet transformation on the walking signal. Person identification was attempted by learning the participant’s scalogram using a convolutional neural network (CNN).
- 6 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 19 (19) , 8934-8939
Noncontact Detection of Movements of Standing Up From and Sitting Down on a Chair Using Electrostatic Induction
In this paper, a new technique to measure the movements of standing up from and sitting down on a chair, which is an example of daily human activities, without using cameras and video images is presented. The change in the electric potential of the human body caused by everyday tasks induces an electrostatic current in the electrode placed in the proximity of the body. By detecting the motion-induced change in the charge of the human body, it is possible to detect the daily activity being performed. This technique is based on the detection of an electrostatic induction current of the order of sub-picoamperes flowing through an electrode placed 5 m from the subject. Therefore, we measured transferring from chair to chair movement as an example of daily activities, and tried to extract the unique features of the individuals included in the movement. The proposed method could further detect details of an individual by detecting the unique patterns of current flow induced during different motions.
- 6 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 19 (19) , 8934-8939
Noncontact Detection of Movements of Standing Up From and Sitting Down on a Chair Using Electrostatic Induction
In this paper, a new technique to measure the movements of standing up from and sitting down on a chair, which is an example of daily human activities, without using cameras and video images is presented. The change in the electric potential of the human body caused by everyday tasks induces an electrostatic current in the electrode placed in the proximity of the body. By detecting the motion-induced change in the charge of the human body, it is possible to detect the daily activity being performed. This technique is based on the detection of an electrostatic induction current of the order of sub-picoamperes flowing through an electrode placed 5 m from the subject. Therefore, we measured transferring from chair to chair movement as an example of daily activities, and tried to extract the unique features of the individuals included in the movement. The proposed method could further detect details of an individual by detecting the unique patterns of current flow induced during different motions.
- 1 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 274-278
Visualization of individual feature amount appearing in daily performance based on electrostatic induction
In this paper, a new technique to measure daily human body motion without using cameras and video images is presented. The change in the electric potential of the human body that is caused by the daily performance induces an electrostatic induction current in the electrode placed at a distance of a few meters from the human body. Using this technology, I have developed an effective non-contact technique for the detection of human daily performance by detecting the change in this human-generated body charge. This technique based on the detection of an electrostatic induction current of the order of approximately sub-picoamperes flowing through an electrode that is placed at a distance of 5 m from the subject. It is shown that the characteristics of the individual are included in walking motion, sitting on a chair and retiring motion. This technique effectively explains the behavior of the waveform of the electrostatic induction current flowing through a given measurement electrode through a capacitance model of the human body.
- 1 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 274-278
Visualization of individual feature amount appearing in daily performance based on electrostatic induction
In this paper, a new technique to measure daily human body motion without using cameras and video images is presented. The change in the electric potential of the human body that is caused by the daily performance induces an electrostatic induction current in the electrode placed at a distance of a few meters from the human body. Using this technology, I have developed an effective non-contact technique for the detection of human daily performance by detecting the change in this human-generated body charge. This technique based on the detection of an electrostatic induction current of the order of approximately sub-picoamperes flowing through an electrode that is placed at a distance of 5 m from the subject. It is shown that the characteristics of the individual are included in walking motion, sitting on a chair and retiring motion. This technique effectively explains the behavior of the waveform of the electrostatic induction current flowing through a given measurement electrode through a capacitance model of the human body.
- 1 January 2015
- Published by Institute of Electrical Engineers of Japan (IEE Japan) in IEEJ Transactions on Electronics, Information and Systems
- Vol. 135 (5) , 492-497
Noncontact Monitoring Technique for Turn Over Motion in Bed
- 1 January 2015
- Published by Institute of Electrical Engineers of Japan (IEE Japan) in IEEJ Transactions on Electronics, Information and Systems
- Vol. 135 (5) , 492-497
Noncontact Monitoring Technique for Turn Over Motion in Bed
- 2 October 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 50 (3) , 2213-2218
Noncontact Hand Motion Classification Technique for Application to Human–Machine Interfaces
In this paper, I present an effective noncontact technique for the measurement of human hand motion with wireless portable motion detection sensors; this technique allows the detection of the subject's hand movements. This method involves the measurement of the current generated due to the difference in the capacitance between the subject's hand and the measurement electrodes in the motion detection sensor. The two motion detection sensors are capable of detecting the direction of the subject's hand movement by measuring the time difference of the peak of the electrostatic induction current. This technique allows us to recognize the direction of the hand movement with respect to the motion detection sensors under perfect noncontact conditions.
- 2 October 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 50 (3) , 2213-2218
Noncontact Hand Motion Classification Technique for Application to Human–Machine Interfaces
In this paper, I present an effective noncontact technique for the measurement of human hand motion with wireless portable motion detection sensors; this technique allows the detection of the subject's hand movements. This method involves the measurement of the current generated due to the difference in the capacitance between the subject's hand and the measurement electrodes in the motion detection sensor. The two motion detection sensors are capable of detecting the direction of the subject's hand movement by measuring the time difference of the peak of the electrostatic induction current. This technique allows us to recognize the direction of the hand movement with respect to the motion detection sensors under perfect noncontact conditions.
- 1 August 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 268-269
Estimation Technique of Friction Caused by Robot Walking Motion
We develop a new sensing technique to estimate the friction produced between the foot of a biped walking robot and the floor. This technique is based on the criteria of effective non-contact and non-attachment, which are considered when studying a robot's walking motion. Our technique involves measuring the electrostatic induction current generated from triboelectricity that results from a change in the electric potential of a walking robot. The waveform of the induced current contains cadence components of both feet. The walking motion of a commercially available biped robot is detected by measuring the current generated in the robot walking under non-contact and non-attached conditions. A theoretical model is proposed for the electrostatic induction current generated as a result of the change in the electric potential of the robot. The waveforms of the electrostatic induction current generated by the biped robot's walking motion on a wood are observed. It is evident that the differences in the floor materials are reflected in the waveform and in the amplitude of the observed peaks. It is considered that friction conditions affect the waveform of the electrostatic induction current since the obtained waveform strongly depends on the floor material.
- 1 August 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 268-269
Estimation Technique of Friction Caused by Robot Walking Motion
We develop a new sensing technique to estimate the friction produced between the foot of a biped walking robot and the floor. This technique is based on the criteria of effective non-contact and non-attachment, which are considered when studying a robot's walking motion. Our technique involves measuring the electrostatic induction current generated from triboelectricity that results from a change in the electric potential of a walking robot. The waveform of the induced current contains cadence components of both feet. The walking motion of a commercially available biped robot is detected by measuring the current generated in the robot walking under non-contact and non-attached conditions. A theoretical model is proposed for the electrostatic induction current generated as a result of the change in the electric potential of the robot. The waveforms of the electrostatic induction current generated by the biped robot's walking motion on a wood are observed. It is evident that the differences in the floor materials are reflected in the waveform and in the amplitude of the observed peaks. It is considered that friction conditions affect the waveform of the electrostatic induction current since the obtained waveform strongly depends on the floor material.
- 1 October 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 19300395,p. 1-4
Physical activity estimation method by using wireless portable sensor
In this study, an effective noncontact technique for the detection of human physical activity is proposed. The technique is based on detecting the electrostatic induction current generated by the walking motion under non-contact and non-attached conditions. A theoretical model for the electrostatic induction current generated because of a change in the electric potential of the human body is proposed. By comparing the obtained electrostatic induction current with the theoretical model, it becomes obvious that this model effectively explains the behavior of the waveform of the electrostatic induction current. The normal walking motions of daily living are recorded using a portable sensor measurement located in an ordinary house. The obtained results show that detailed information regarding physical activity such as a walking cycle can be estimated using our proposed technique. Additionally, the walking signal is measured when the subject walked with the ankle and knee of the foot fastened to a splint with bandages. This suggests that the proposed technique, which is based on the detection of the walking signal, can be successfully applied to the estimation of the quality of human walking motion.
- 1 October 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 19300395,p. 1-4
Physical activity estimation method by using wireless portable sensor
In this study, an effective noncontact technique for the detection of human physical activity is proposed. The technique is based on detecting the electrostatic induction current generated by the walking motion under non-contact and non-attached conditions. A theoretical model for the electrostatic induction current generated because of a change in the electric potential of the human body is proposed. By comparing the obtained electrostatic induction current with the theoretical model, it becomes obvious that this model effectively explains the behavior of the waveform of the electrostatic induction current. The normal walking motions of daily living are recorded using a portable sensor measurement located in an ordinary house. The obtained results show that detailed information regarding physical activity such as a walking cycle can be estimated using our proposed technique. Additionally, the walking signal is measured when the subject walked with the ankle and knee of the foot fastened to a splint with bandages. This suggests that the proposed technique, which is based on the detection of the walking signal, can be successfully applied to the estimation of the quality of human walking motion.
- 25 July 2012
- Published by Springer Nature in Artificial Life and Robotics
- Vol. 17 (1) , 97-101
Non-contact physical activity estimation method based on electrostatic induction technique
- 25 July 2012
- Published by Springer Nature in Artificial Life and Robotics
- Vol. 17 (1) , 97-101
Non-contact physical activity estimation method based on electrostatic induction technique