SLSiyuan Liu

Siyuan Liu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Siyuan Liu has a total of 8 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Method for Measuring Shaft Diameter Based on Light Stripe Image Enhancement

    by Chunfeng Li, Xiping Xu, Siyuan Liu, Zhen Ren

    When the workpiece surface exhibits strong reflectivity, it becomes challenging to obtain accurate key measurements using non-contact, visual measurement techniques due to poor image quality. In this paper, we propose a high-precision measurement method shaft diameter based on an enhanced quality stripe image. By capturing two stripe images with different exposure times, we leverage their different characteristics. The results extracted from the low-exposure image are used to perform grayscale correction on the high-exposure image, improving the distribution of stripe grayscale and resulting in more accurate extraction results for the center points. The incorporation of different measurement positions and angles further enhanced measurement precision and robustness. Additionally, ellipse fitting is employed to derive shaft diameter. This method was applied to the profiles of different cross-sections and angles within the same shaft segment. To reduce the shape error of the shaft measurement, the average of these measurements was taken as the estimate of the average diameter for the shaft segment. In the experiments, the average shaft diameters determined by averaging elliptical estimations were compared with shaft diameters obtained using a coordinate measuring machine (CMM) the maximum error and the minimum error were respectively 18 μm and 7 μm; the average error was 11 μm; and the root mean squared error of the multiple measurement results was 10.98 μm. The measurement accuracy achieved is six times higher than that obtained from the unprocessed stripe images.


  • Open Access

    Research on Calibration Method of Line-Structured Light Based on Multiple Geometric Constraints

    by Chunfeng Li, Xiping Xu, Zhen Ren, Siyuan Liu

    Line-structured light calibration is an important step in the process of the visual measurement of structured light, and in the calibration process, the light plane equation is fitted by the camera coordinates of the data points on the light plane. There is error in solving the spatial coordinates of the data points, and the existing methods generally cannot effectively find the deviation points in the fitted data points, which leads to deviation when solving the parameters of the light plane equation. To correct the error caused by the deviation point in the calibration, this paper established a calibration method based on geometric constraints. In the method, the first constraint was that all fit points involved in the fitting had a certain consistency, and a part of the error points could be filtered by the distance from the data point to the light plane. In order to further improve the calibration accuracy, the laser was moved on a linear guide, the optimized objective function was established by the second geometric constraint, and the constraint was the relationship that the light plane at each position was parallel. In the experiment, a high-precision gauge block was used as the measured object, and the measurement results could be obtained. The calibration method can improve the calibration accuracy according to the experimental results.


  • Open Access

    A Model of Diameter Measurement Based on the Machine Vision

    by Qingchang Tan, Ying Kou, Jianwei Miao, Siyuan Liu, Bosen Chai

    If the shaft diameter can be measured in-situ during the finishing process, the closed-loop control of the shaft diameter processing process can be realized and the machining accuracy can be improved. Present work studies the measurement of shaft diameter with the structured light system composed of a laser linear light source and a camera. The shaft is a kind of part with rotationally symmetric structure. When the linear structured light irradiates the surface of the shaft, a light stripe will be formed, and the light stripe is a part of the ellipse. Therefore, the in-situ measurement of the shaft diameter can be realized by the light stripe and the rotational symmetry of the shaft. The measurement model of shaft diameter is established by the ellipse formed by the intersection of the light plane and the measured shaft surface. Firstly, in the camera coordinate system, normal vector of the light plane and the coordinates of the ellipse center are obtained by the calibration; then, the equation of oblique elliptic cone is established by taking the ellipse as the bottom and the optical center of the camera as the top. Next, the measurement model of shaft diameter is obtained by the established oblique elliptic cone equation and theoretical image plane equation. Finally, the accuracy of the measurement model of shaft diameter is tested by the checkerboard calibration plate and a lathe. The test results show that the measurement model of shaft diameter is correct, and when the shaft diameter is 36.162mm, the speed is 1250r/min, the maximum average measurement error is 0.019mm. The measurement accuracy meets the engineering requirement.


  • Open Access

    Computer Vision Measurement of Pointer Meter Readings Based on Inverse Perspective Mapping

    by Haojing Bao, Qingchang Tan, Siyuan Liu, Jianwei Miao

    A computer vision method for measuring multiple pointer meters is proposed based on the inverse perspective mapping. First, the measured meter scales are used as the calibration objects to obtain the extrinsic parameters of the meter plane. Second, normal vector of the meter plane can be acquired by the extrinsic parameters, obtaining the rotation transformation matrix of the meter image. Then, the acquired meter image is transformed to a position both parallel to the meter plane and near the main point by the rotation transformation matrix and the extrinsic parameters, eliminating the perspective effect of the acquired image. Finally, the transformed image is tested by the visual detection method to obtain the readings of the pointer meter, improving measurement precision. The results of the measurement verify the effectiveness and accuracy of the method.