ASArtur Stelęgowski

Artur Stelęgowski

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Artur Stelęgowski has a total of 3 co-authors. Here are the top co-authors by number of shared publications:

  • Robert Cichowicz

    Faculty of Civil Engineering, Architecture and Environmental Engineering, Lodz University of Technology, Al. Politechniki 6, 90-924 Lodz, Poland

    6 shared publications
  • Anna Pacak

    Lodz University of Technology, Faculty of Architecture, Civil and Environmental Engineering, Al. Politechniki 6, 90-924 Łódź, Poland

    1 shared publication
  • Robert Cichowicz

    Lodz University of Technology

    1 shared publication

Latest Publications

  • Open Access

    Hourly Profiles of Air Pollution Variation in Selected Cities, Towns and Villages in Poland

    by Robert Cichowicz, Artur Stelegowski

    Concentration of air pollution in urbanized and agricultural areas is related to the activity of various economy sectors (the so-called SNAP categories). Therefore, the change in the emission of pollutants by an anthropogenic source should result in a change in the air pollution level in the selected area. To better understand the nature of changes in air pollution concentration in urban and agricultural areas, an analysis of data of five-year (2012-2016) air quality measurements, carried out at selected automatic air quality monitoring stations in Poland, Europe. The data came from stations located in 5 regions (Lower Silesia, Greater Poland, Lodz, Masovia and Lublin) in central Poland. The average hourly concentrations in selected areas in cities, towns and villages were compared with the hourly emission factors of power generation sector (SNAP1), residential and commercial combustion sector (SNAP2) and road transport sector (SNAP7). The hourly profiles of air pollution level were expressed by means of the “imission factor”, as analogous to the hourly profiles of the “emission factor” that is being used in the LOTOS-EUROS and the CHIMERE chemistry-transport models.


  • Open Access

    Daily variability of air pollution in locations of different population density

    by Robert Cichowicz, Artur Stelęgowski

    The air quality levels vary during a day, especially in inhabited areas. Therefore, it seems reasonable to observe and analyze the occurrence of daily maximum and minimum level of air pollution. In this article, data obtained from automatic air quality monitoring stations located in 5 large, 5 small and medium cities and 5 villages in Poland was analyzed in 2012−2016. Those locations vary, inter alia, depending on number of inhabitants and population density, and for this reason also due to the presence of air contaminants. As an indicator of daily variability air pollution it was determined the ratio of maximum to minimum concentrations of selected air pollutants (NO2 and NOx, and O3, SO2, CO, PM10 and PM2.5, and benzene) in urban and agricultural areas. In winter, the daily changes were bigger in cities than in villages. While in summer, the level of daily variability was similar, irrespective of size of the settlement unit. The biggest daily changes concerned nitrogen oxides, the lowest − sulfur dioxide and dusts.

  • Open Access

    Average Hourly Concentrations of Air Contaminants in Selected Urban, Town, and Rural Sites

    by Robert Cichowicz, Artur Stelęgowski

    The inhabitants of cities, towns, and villages are exposed to different levels of air pollution, which also vary throughout the day. Information regarding episodes of poor and good air quality enables planning to mitigate the risks and maximize the benefits of spending time outdoors. In this work, an analysis was made of the state of air quality 2012–2016, using data gathered from automatic measuring stations located in five cities (> 50,000 inhabitants), five towns (5000–50,000 inhabitants), and five villages (< 5000 inhabitants) in five neighboring provinces in central Poland, in Central Europe. The monitoring stations were designated as “city background”, “town background”, and “rural background”. More than 3 million pieces of data were collected from 15 monitoring stations. This allowed the average daily changes in the concentration of air pollutants (NO2 and NOx, O3, SO2, CO, PM10, PM2.5, C6H6) to be determined, depending on the type of station and the size of the settlement unit in both winter periods and summer periods. As a result, the most and least favorable hours in terms of levels of air pollution were identified. This information could help to inform air quality management in modern cities, towns, and villages and to improve the quality of life, particularly among those most susceptible to the negative effects of air pollution, such as the elderly and children. Graphical Abstract


  • Open Access

    Correlations between air pollutant concentrations in selected urban and rural areas in Poland

    by Artur Stelęgowski

    Correlations between concentrations of selected air pollutants were analyzed in different areas in central Poland from 2012-2016. Three neighboring voivodeships (Lower Silesian, Lodz, and Masovian), were selected for which specific measurement locations were designated in urban and rural areas. The characteristics of the location of monitoring stations allowed to distinguish the following types of measurement stations: “urbantransport”, “urban-background", "suburban-background", "town-background", and "rural-background". Therefore, using the Pearson's linear correlation coefficient, it was possible to analyze the interrelations between the occurrence of air pollution in various types of areas. It was found that the coefficient changed along with the type of area. Moreover, it turned out that the coefficient decreased in each voivodeship along with a decrease in the population density of the analyzed areas. In addition, concentrations of various air pollutants in given areas were compared. Also, it was observed that the strongest correlations occur between the results of calculations from measurement stations located in the same province.


  • Open Access

    Selected air pollutants in urban and rural areas, under the influence of power plants

    by Robert Cichowicz, Artur Stelegowski

    The operation of large power plants, including power stations, and combined heat and power stations, causes the emission of significant amounts of gaseous pollutants into the environment. As a result, in the urban and agricultural areas occurs a pollution of undesirable gaseous substances, such as nitrogen and sulfur oxides. This is especially dangerous for living organisms, soil and water, because, in combination with water vapor, these pollutants are the cause of acid rain. In addition, nitrogen oxides participate in the formation of ground-level ozone, which affects both human health and the condition of existing vegetation. Therefore, the distribution of air pollutants (NO2, SO2 and O3) in the selected urban and rural areas, under the influence of power plants, located in the Lodz Voivodeship, in Poland, in Central-Eastern Europe, was analyzed for a 10-year period (2007–2016). As a result, it was possible to evaluate the impact of the entry into force of Directive 2008/50/EC of the European Parliament and of the Council of 21 May 2008 “on ambient air quality and cleaner air for Europe” on the changes in emissions and concentrations of pollutants in selected locations. As a result of the analysis, a significant decrease in the concentration of SO2 (by 75% in the urban area and by 59% in the rural area), and small changes (from - 8% to + 12%) in NO2 and O3 concentrations in ambient air were found. This indicates the effectiveness of actions aimed at reducing SO2 emissions, however the influence of the power plants on the concentration of air pollutants in these areas is not clear. At the same time, considering the criterion of permissible concentration of ozone and nitrogen dioxide, although the air quality did not improve, the air quality index can be considered as being in the category of "good".


  • Open Access

    The PMV and PPD indices in the selected boiler room

    by Robert Cichowicz, Artur Stelęgowski

    Thermal microclimate in a boiler room is formed by factors resulting from thermal processes that are taking place in combustion units. These factors are negatively affecting the indoor environment by worsening the air quality, and therefore it is crucial to maintain adequate air parameters in the room. It is a consequence of the fact that in the boiler room the operation of technological equipment results in an exposure of workers to adverse effects caused by thermal factors. Therefore, the evaluation of thermal conditions in the work area of people was made for the selected industrial boiler room using PMV and PPD indices (which allow to determine the thermal sensation of employees, regarding their surrounding thermal environment, based on the methodology of ISO 7730 standard). The analysis was based on own experimental measurements and numerical calculations made in the DesignBuilder program.


  • Open Access

    The distribution of air temperature and velocity in the selected boiler room

    by Robert Cichowicz, Artur Stelęgowski, Anna Pacak

    The crucial impact on the indoor air quality in technological rooms, including boiler plant buildings, is made by operation of technological devices and ventilation systems. Therefore, the distribution of air temperature and velocity in these rooms mainly depends on location and heat gains generated by combustion devices, as well as emplacement of air supply and air exhaust elements. The temperature and airflow volume of supplied air is also an issue, because the indoor environment parameters are formed by the flow of air in the working area. Determination of the impact of physical factors on the thermal environment in a room is possible using an analysis of the air temperature and velocity. This issue is vital in terms of necessity to maintain the adequate heat conditions in the working area. Therefore, basing on the experimental measurements and numerical calculations (made in DesignBuilder software), the distribution of air temperature and velocity was analyzed in the selected industrial boiler room, located in the Lodz city, in Poland. The results obtained were compared with the recommended and limit values in the industrial buildings.