Nicholaos Limberopoulos
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Nicholaos Limberopoulos has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Dalila B. Megherbi
CMINDS Research Center, Department of Electrical and Computer Engineering, University of Massachusetts Lowell, MA 01854
4 shared publications - M. Imran Vakil
CMINDS Research Center, Department of Electrical and Computer Engineering, University of Massachusetts Lowell, MA 01854
4 shared publications - Augustine Urbas
Air Force Research Lab. (United States)
3 shared publications J. DiZoglio
University of Massachusetts,CMINDS Research Center,Department of Electrical and Computer Engineering,Lowell,MA,USA
3 shared publicationsP. Mack
University of Massachusetts,CMINDS Research Center,Department of Electrical and Computer Engineering,Lowell,MA,USA
3 shared publications- Ilya Vitebskiy
Wright-Patterson Air Force Base
2 shared publications
Latest Publications
- 16 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 154-156
Modeling and Characterization of the Effect of Misalignment between Microsphere-Sensor on the Sensitivity of Microsphere-Lens-Enhanced MWIR SLS Photodetectors
A microsphere lens integrated on top of an MWIR photodetector has exhibited an increase in detector overall sensitivity over a desired spectral bandwidth and, more importantly, a decrease in Noise-to-Signal-Ratio (NSR), as we have shown in our prior work. Using signal processing methods, we have also shown, for the first time, the existence of an adverse effect of microsphere misalignment on the detector's overall sensitivity. In this paper, we model and analyze the effect of various misalignment types between the microsphere-lens and the photodetector on the resulting detector sensitivity. As we show here, microsphere lens-sensor misalignment can result, to some varying degrees, in reduced spectral responses in microspheres-lens-enhanced MWIR photodetectors. We also model and analyze the effect of such misalignment on multiple SLS photodetector sizes, namely 35 $\mu\mathrm{m}$ and 40 $\mu \mathrm{m}$ , and microsphere material types, namely Sapphire and Polystyrene. In the case of Polystyrene material, the results show that the sensitivity of the microsphere-lens-enhanced detector is mainly and significantly reduced by the microsphere Polystyrene material alone around wavenumber 3000, due to the Polystyrene material spectral absorptions around that wavenumber.- 16 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 154-156
Modeling and Characterization of the Effect of Misalignment between Microsphere-Sensor on the Sensitivity of Microsphere-Lens-Enhanced MWIR SLS Photodetectors
A microsphere lens integrated on top of an MWIR photodetector has exhibited an increase in detector overall sensitivity over a desired spectral bandwidth and, more importantly, a decrease in Noise-to-Signal-Ratio (NSR), as we have shown in our prior work. Using signal processing methods, we have also shown, for the first time, the existence of an adverse effect of microsphere misalignment on the detector's overall sensitivity. In this paper, we model and analyze the effect of various misalignment types between the microsphere-lens and the photodetector on the resulting detector sensitivity. As we show here, microsphere lens-sensor misalignment can result, to some varying degrees, in reduced spectral responses in microspheres-lens-enhanced MWIR photodetectors. We also model and analyze the effect of such misalignment on multiple SLS photodetector sizes, namely 35 $\mu\mathrm{m}$ and 40 $\mu \mathrm{m}$ , and microsphere material types, namely Sapphire and Polystyrene. In the case of Polystyrene material, the results show that the sensitivity of the microsphere-lens-enhanced detector is mainly and significantly reduced by the microsphere Polystyrene material alone around wavenumber 3000, due to the Polystyrene material spectral absorptions around that wavenumber.- 29 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 20 (4) , 1851-1858
Optimal Sphere-Sensor Ratio for Microsphere-Enhanced Photodetector Sensors in Cameras/Telescopes With and Without Central Obscuration
- 29 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 20 (4) , 1851-1858
Optimal Sphere-Sensor Ratio for Microsphere-Enhanced Photodetector Sensors in Cameras/Telescopes With and Without Central Obscuration
- 8 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Antennas and Propagation
- Vol. 66 (9) , 4844-4853
A Planar, Broadband, Metamaterial-Based, Transmission-Line Beamformer
A broadband, 7-port beamformer is designed and fabricated using printed-circuit, tensor transmission-line metamaterials. The beamformer is first modeled as a 2D medium with an unknown inhomogeneous, anisotropic material distribution: scalar permittivity ϵ(x, y) and tensor permeability μ(x, y). Then, a recently-developed optimization procedure is employed to determine ϵ(x, y) and μ(x, y) and subsequently realized using tensor transmission-line metamaterials. The beamformer is designed to switch beams in 10° increments from -30° to 30° in azimuth, over a broad range of frequencies. Measurement results exhibit good agreement with the prescribed design goals. The reported beamformer offers several advantages compared to traditional beamformers, including the stipulation of arbitrary output fields, flat input/output interfaces, and broad bandwidth performance.
- 8 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Antennas and Propagation
- Vol. 66 (9) , 4844-4853
A Planar, Broadband, Metamaterial-Based, Transmission-Line Beamformer
A broadband, 7-port beamformer is designed and fabricated using printed-circuit, tensor transmission-line metamaterials. The beamformer is first modeled as a 2D medium with an unknown inhomogeneous, anisotropic material distribution: scalar permittivity ϵ(x, y) and tensor permeability μ(x, y). Then, a recently-developed optimization procedure is employed to determine ϵ(x, y) and μ(x, y) and subsequently realized using tensor transmission-line metamaterials. The beamformer is designed to switch beams in 10° increments from -30° to 30° in azimuth, over a broad range of frequencies. Measurement results exhibit good agreement with the prescribed design goals. The reported beamformer offers several advantages compared to traditional beamformers, including the stipulation of arbitrary output fields, flat input/output interfaces, and broad bandwidth performance.
- Open Access
- 22 January 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Journal
- Vol. 10 (2) , 1-9
Broadband Reflective Optical Limiter Using GST Phase Change Material
We experimentally demonstrate a thermally induced reflective optical limiter using Ge 2 Sb 2 Te 5 (GST) and SiO 2 in a multilayer photonic bandgap edge-filter configuration. In the PASS state, greater than 80% transmission was achieved at λ ~ 1500 nm over a 300 nm spectral bandwidth and ±45° angles of incidence. In the BLOCK state, extinction ratios higher than 30 dB were achieved. By comparison, all previous optical limiters based on nonlinear photonic crystals have severe spectral bandwidth and/or angle of incidence limitations in either the PASS or BLOCK states. A nine-layer implementation of this device was fabricated and tested in this paper. Numerical modeling results show reasonable agreement with measured values. To the best of our knowledge, this is the first demonstration of optical limiting over a broad spectral band using phase change materials with this level of performance. However, it should be noted that although GST can be switched in both directions, the experimental results demonstrated in this paper are limited to PASS-to-BLOCK switching only.
- 22 January 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Journal
- Vol. 10 (2) , 1-9
Open AccessBroadband Reflective Optical Limiter Using GST Phase Change Material
We experimentally demonstrate a thermally induced reflective optical limiter using Ge 2 Sb 2 Te 5 (GST) and SiO 2 in a multilayer photonic bandgap edge-filter configuration. In the PASS state, greater than 80% transmission was achieved at λ ~ 1500 nm over a 300 nm spectral bandwidth and ±45° angles of incidence. In the BLOCK state, extinction ratios higher than 30 dB were achieved. By comparison, all previous optical limiters based on nonlinear photonic crystals have severe spectral bandwidth and/or angle of incidence limitations in either the PASS or BLOCK states. A nine-layer implementation of this device was fabricated and tested in this paper. Numerical modeling results show reasonable agreement with measured values. To the best of our knowledge, this is the first demonstration of optical limiting over a broad spectral band using phase change materials with this level of performance. However, it should be noted that although GST can be switched in both directions, the experimental results demonstrated in this paper are limited to PASS-to-BLOCK switching only.
- 1 June 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 62, 199-204
Using FTIR spectral response signals to separate, characterize and quantify the effects of silicone or rubber-based adhesive materials on microsphere lens enhanced MWIR SLS photo detectors
In our prior work we have analyzed, proposed global performance metrics, and shown how MWIR microsphere lens-enhanced single detectors have exhibited an increase in detector sensitivity and reduction in Noise to Signal Ratio (NSR). We have shown that, in general, the microsphere lens reduces the detector NSR independently of the increase in the enhanced detector sensitivity. We have also shown how microsphere lens material absorptions and misalignments can affect and reduce the microsphere lens-enhanced MWIR detector sensitivity. When placing a microsphere lens on a photo-detector, usually an optical silicone-or rubber adhesive is used to adhere and hold the microsphere lens on the single photo-detector. In this paper, we present a novel hybrid model-based and experimental data driven-based technique for analysis and characterization of the effect of the adhesive material on microsphere-lens-enhanced SLS single photo-detector sensitivity. In this work these adhesive material characteristics are modeled and compared to experimental microsphere-enhanced single detector FTIR spectral data. As we demonstrate here, based on the data considered, the results show that the adhesive material appears to adversely affect and decrease the detector overall sensitivity, and in some instances, by more than 40% depending on the adhesive material index of refraction, even with a high adhesive material transmittance/transparency.
- 1 June 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 62, 199-204
Using FTIR spectral response signals to separate, characterize and quantify the effects of silicone or rubber-based adhesive materials on microsphere lens enhanced MWIR SLS photo detectors
In our prior work we have analyzed, proposed global performance metrics, and shown how MWIR microsphere lens-enhanced single detectors have exhibited an increase in detector sensitivity and reduction in Noise to Signal Ratio (NSR). We have shown that, in general, the microsphere lens reduces the detector NSR independently of the increase in the enhanced detector sensitivity. We have also shown how microsphere lens material absorptions and misalignments can affect and reduce the microsphere lens-enhanced MWIR detector sensitivity. When placing a microsphere lens on a photo-detector, usually an optical silicone-or rubber adhesive is used to adhere and hold the microsphere lens on the single photo-detector. In this paper, we present a novel hybrid model-based and experimental data driven-based technique for analysis and characterization of the effect of the adhesive material on microsphere-lens-enhanced SLS single photo-detector sensitivity. In this work these adhesive material characteristics are modeled and compared to experimental microsphere-enhanced single detector FTIR spectral data. As we demonstrate here, based on the data considered, the results show that the adhesive material appears to adversely affect and decrease the detector overall sensitivity, and in some instances, by more than 40% depending on the adhesive material index of refraction, even with a high adhesive material transmittance/transparency.
- 1 June 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 62, 193-198
A signal processing and data analysis technique for accurate extraction and estimation of FTIR signal aberrations in microsphere-lens-enhanced MWIR photo detectors via system transfer functions mathematical modeling
In this paper we focus on using signal processing techniques and mathematically-derived photo-detector models, with or without microsphere-lens-enhancement, to analyze, characterize and estimate the effect of integrated aberrations on microsphere-lens-enhanced single photo-detector sensitivity. One of the difficulties here relates to the noisy nature of detector FTIR experimental signals in the MWIR band. We show how modeling of the detector spectral response signal, combined with signal boundary-absorption partial replacement, is successfully effective in estimating integrated detector system aberrations. With the detector FTIR spectral data, considered, our findings show that (a) not all four microsphere materials, considered in this work, namely, Sapphire, SLG (Soda, Lime Glass), PS (Polystyrene) and BTG (Barium Titanate Glass) necessarily result in detector sensitivity increase at all MWIR wavelengths. The PS-microsphere-lens-enhanced detector sensitivity turns out to be less than that of the detector without enhancement in the 2700-3200 wavenumber band. This is due to the fact at this band the PS material exhibits additional significant spectral absorptions. (b) there seems to exist some global detector integrated aberrations introduced by factors such as the microsphere lens material and misalignment, silicone-or-rubber adhesive material, photo-detector system and others, that we globally extracted/estimated using the detector experimental FTIR spectral responses and their corresponding generated detector mathematical models. (c) comparison of single detector raw experimental spectral responses (with and without microsphere-lenses of different sizes and material types) to their respective resulting models, shows realistic synthesized detector FTIR data models. With the help of theses resulting detector FTIR response models, we are able to confirm our findings that, relatively independently of the increase in the sensitivity, the microsphere lens significantly decreases the sphere-enhanced-detector Noise to Signal Ratio (NSR), including in spectral bands of high absorption, noise, and aberration. That is, based on the data considered, (1) the resulting microsphere-enhanced photo-detector is generally less sensitive to noise in the MWIR than the mesa and (2) this, seemingly is so, independently of the detector sensitivity increase, for example, due to the microsphere size of a certain material type.
- 1 June 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 62, 193-198
A signal processing and data analysis technique for accurate extraction and estimation of FTIR signal aberrations in microsphere-lens-enhanced MWIR photo detectors via system transfer functions mathematical modeling
In this paper we focus on using signal processing techniques and mathematically-derived photo-detector models, with or without microsphere-lens-enhancement, to analyze, characterize and estimate the effect of integrated aberrations on microsphere-lens-enhanced single photo-detector sensitivity. One of the difficulties here relates to the noisy nature of detector FTIR experimental signals in the MWIR band. We show how modeling of the detector spectral response signal, combined with signal boundary-absorption partial replacement, is successfully effective in estimating integrated detector system aberrations. With the detector FTIR spectral data, considered, our findings show that (a) not all four microsphere materials, considered in this work, namely, Sapphire, SLG (Soda, Lime Glass), PS (Polystyrene) and BTG (Barium Titanate Glass) necessarily result in detector sensitivity increase at all MWIR wavelengths. The PS-microsphere-lens-enhanced detector sensitivity turns out to be less than that of the detector without enhancement in the 2700-3200 wavenumber band. This is due to the fact at this band the PS material exhibits additional significant spectral absorptions. (b) there seems to exist some global detector integrated aberrations introduced by factors such as the microsphere lens material and misalignment, silicone-or-rubber adhesive material, photo-detector system and others, that we globally extracted/estimated using the detector experimental FTIR spectral responses and their corresponding generated detector mathematical models. (c) comparison of single detector raw experimental spectral responses (with and without microsphere-lenses of different sizes and material types) to their respective resulting models, shows realistic synthesized detector FTIR data models. With the help of theses resulting detector FTIR response models, we are able to confirm our findings that, relatively independently of the increase in the sensitivity, the microsphere lens significantly decreases the sphere-enhanced-detector Noise to Signal Ratio (NSR), including in spectral bands of high absorption, noise, and aberration. That is, based on the data considered, (1) the resulting microsphere-enhanced photo-detector is generally less sensitive to noise in the MWIR than the mesa and (2) this, seemingly is so, independently of the detector sensitivity increase, for example, due to the microsphere size of a certain material type.
- 23 February 2017
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10077, 100770S-100770S-7
Contact microspherical nanoscopy: from fundamentals to biomedical applications
- 23 February 2017
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10077, 100770S-100770S-7
Contact microspherical nanoscopy: from fundamentals to biomedical applications
- Open Access
- 20 June 2016
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 5 (6) , 064010
Experimental Realization of a Reflective Optical Limiter
Optical limiters transmit low-intensity light, while blocking laser radiation with excessively high irradiance or fluence. A typical optical limiter involves a nonlinear material which is transparent at low light intensity and becomes opaque when the light intensity exceeds a certain level. Most of the high-level radiation is absorbed by the nonlinear material causing irreversible damage. This fundamental problem could be solved if the state of the nonlinear material changed from transparent to highly reflective (not absorptive) when the intensity becomes too high. None of the known nonlinear optical materials display such a property. A solution can be provided by a nonlinear photonic structure. In this communication, we report the experimental realization of a reflective optical limiter. The design is based on a planar microcavity composed of alternating and layers with a single GaAs defect layer in the middle. At low intensity, the planar microcavity displays a strong resonant transmission via a cavity mode. As the intensity increases, two-photon absorption in GaAs kicks in, initially resulting in the microcavity-enhanced light absorption. A further increase in light intensity, though, suppresses the cavity mode along with the resonant transmission; the entire planar microcavity turns highly reflective within a broad frequency range covering the entire photonic band gap. This seemingly counterintuitive behavior is a general feature of resonant transmission via a cavity mode with purely nonlinear absorption.- 20 June 2016
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 5 (6) , 064010
Open AccessExperimental Realization of a Reflective Optical Limiter
Optical limiters transmit low-intensity light, while blocking laser radiation with excessively high irradiance or fluence. A typical optical limiter involves a nonlinear material which is transparent at low light intensity and becomes opaque when the light intensity exceeds a certain level. Most of the high-level radiation is absorbed by the nonlinear material causing irreversible damage. This fundamental problem could be solved if the state of the nonlinear material changed from transparent to highly reflective (not absorptive) when the intensity becomes too high. None of the known nonlinear optical materials display such a property. A solution can be provided by a nonlinear photonic structure. In this communication, we report the experimental realization of a reflective optical limiter. The design is based on a planar microcavity composed of alternating and layers with a single GaAs defect layer in the middle. At low intensity, the planar microcavity displays a strong resonant transmission via a cavity mode. As the intensity increases, two-photon absorption in GaAs kicks in, initially resulting in the microcavity-enhanced light absorption. A further increase in light intensity, though, suppresses the cavity mode along with the resonant transmission; the entire planar microcavity turns highly reflective within a broad frequency range covering the entire photonic band gap. This seemingly counterintuitive behavior is a general feature of resonant transmission via a cavity mode with purely nonlinear absorption.