Christoph Vanselow
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Christoph Vanselow has a total of 70 co-authors. Here are the top co-authors by number of shared publications:
- Andreas Fischer
University of Bremen, Bremen Institute for Metrology, Automation and Quality Science (BIMAQ), Bremen, Germany
6 shared publications - Dirk Stöbener
Bremen Institute for Metrology, Automation and Quality Science, University of Bremen, Linzer Str. 13, 28359 Bremen, Germany
6 shared publications - Björn Espenhahn
MAPEX Center for Materials and Processes, University of Bremen, Bibliothekstr. 1, 28359 Bremen, Germany
3 shared publications - Daniel Meyer
Leibniz Institute for Materials Engineering IWT, Badgasteiner Straße 3, 28359 Bremen, Germany
3 shared publications - Lukas Schumski
Leibniz-Institute for Materials Engineering IWT, Badgasteiner Str. 3, 28359 Bremen, Germany
3 shared publications - Johannes Kiefer
Technische Thermodynamik, University of Bremen, Badgasteiner Str. 1, 28359 Bremen, Germany
2 shared publications
Latest Publications
- Open Access
- 16 September 2024
- Published by Springer Nature in Experiments in Fluids
- Vol. 65 (9) , 1
Correction to: Particle image velocimetry in refractive index felds of combustion flows
- 16 September 2024
- Published by Springer Nature in Experiments in Fluids
- Vol. 65 (9) , 1
Open AccessCorrection to: Particle image velocimetry in refractive index felds of combustion flows
- Open Access
- 7 December 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (24) , 11615
Feasibility of Optical Flow Field Measurements of the Coolant in a Grinding Machine
For industrial grinding processes, the workpiece cooling by metalworking fluids, which strongly influences the workpiece surface layer quality, is not yet fully understood. This leads to high efforts for the empirical determination of suitable cooling parameters, increasing the part manufacturing costs. To close the knowledge gap, a measurement method for the metalworking fluid flow field near the grinding wheel is desired. However, the varying curved surfaces of the liquid phase result in unpredictable light deflections and reflections, which impede optical flow measurements. In order to investigate the yet unknown optical measurement capabilities achievable under these conditions, shadowgraphy in combination with a pattern correlation technique and particle image velocimetry (PIV) are applied in a grinding machine. The results show that particle image velocimetry enables flow field measurements inside the laminar metalworking fluid jet, whereby the shadowgraph imaging velocimetry complements these measurements since it is in particular suitable for regions with spray-like flow regimes. As a conclusion, optical flow field measurements of the metalworking fluid flow in a running grinding machine are shown to be feasible.
- 7 December 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (24) , 11615
Open AccessFeasibility of Optical Flow Field Measurements of the Coolant in a Grinding Machine
For industrial grinding processes, the workpiece cooling by metalworking fluids, which strongly influences the workpiece surface layer quality, is not yet fully understood. This leads to high efforts for the empirical determination of suitable cooling parameters, increasing the part manufacturing costs. To close the knowledge gap, a measurement method for the metalworking fluid flow field near the grinding wheel is desired. However, the varying curved surfaces of the liquid phase result in unpredictable light deflections and reflections, which impede optical flow measurements. In order to investigate the yet unknown optical measurement capabilities achievable under these conditions, shadowgraphy in combination with a pattern correlation technique and particle image velocimetry (PIV) are applied in a grinding machine. The results show that particle image velocimetry enables flow field measurements inside the laminar metalworking fluid jet, whereby the shadowgraph imaging velocimetry complements these measurements since it is in particular suitable for regions with spray-like flow regimes. As a conclusion, optical flow field measurements of the metalworking fluid flow in a running grinding machine are shown to be feasible.
- Open Access
- 18 November 2021
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
- Vol. 88 (12)
Frontmatter
Article Frontmatter was published on December 1, 2021 in the journal tm - Technisches Messen (volume 88, issue 12).
- 18 November 2021
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
- Vol. 88 (12)
Open AccessFrontmatter
Article Frontmatter was published on December 1, 2021 in the journal tm - Technisches Messen (volume 88, issue 12).
- Open Access
- 9 November 2021
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
- Vol. 88 (12) , 785-794
Strömungsfeldmessung der Kühlschmierstoffzufuhr an der Schleifscheibe
Zusammenfassung Kühlschmierstoff (KSS)-strömungen werden in Schleifprozessen eingesetzt, um Schleifbrand am Werkstück zu verhindern. Bislang wurde die KSS-Zufuhr heuristisch optimiert.Um eine zielgerichtete KSS-Strömungsoptimierung zu ermöglichen, wird erstmals die optische schleifscheibennahe Messung von KSS-Strömungsfeldern mittels Particle Image Velocimetry (PIV) und durch Nachverfolgung von Mustern in Schattenwurfbildern untersucht. Als erster Schritt wird an der rotierenden Schleifscheibe, jedoch ohne die Bearbeitung eines Werkstücks, gemessen. Beide Messmethoden liefern vergleichbare Ergebnisse, wobei nahe der Schleifscheibenoberfläche mittels PIV Messwerte mit geringerer Messunsicherheit erzielt werden. Mit dem verwendeten Messaufbau lassen sich mittels PIV Geschwindigkeiten in einem Abstand zwischen 0 cm bis 2 cm und mittels Schattenwurf zwischen 0 cm bis 5 cm zur Schleifscheibenoberfläche messen. Im Ergebnis konnte erstmals der für die Kühlleistung relevante Parameter des Geschwindigkeitsverhältnisses zwischen KSS-Anströmung und Schleifscheibenoberflächengeschwindigkeit in situ gemessen werden. Es wurde festgestellt, dass eine aus der Literatur bekannte Verringerung der Kühleffizienz ab einem Geschwindigkeitsverhältnis von 0,8 mit einem Abprallen des KSS-Strahls beim Auftreffen auf die Schleifscheibe korreliert. In zukünftigen Untersuchungen ist zu klären, wie sich die hier gewonnenen Erkenntnisse zur Messfähigkeit und zum Strömungsverhalten auf den Schleifprozess mit Werkstück übertragen lassen.
- 9 November 2021
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
- Vol. 88 (12) , 785-794
Open AccessStrömungsfeldmessung der Kühlschmierstoffzufuhr an der Schleifscheibe
Zusammenfassung Kühlschmierstoff (KSS)-strömungen werden in Schleifprozessen eingesetzt, um Schleifbrand am Werkstück zu verhindern. Bislang wurde die KSS-Zufuhr heuristisch optimiert.Um eine zielgerichtete KSS-Strömungsoptimierung zu ermöglichen, wird erstmals die optische schleifscheibennahe Messung von KSS-Strömungsfeldern mittels Particle Image Velocimetry (PIV) und durch Nachverfolgung von Mustern in Schattenwurfbildern untersucht. Als erster Schritt wird an der rotierenden Schleifscheibe, jedoch ohne die Bearbeitung eines Werkstücks, gemessen. Beide Messmethoden liefern vergleichbare Ergebnisse, wobei nahe der Schleifscheibenoberfläche mittels PIV Messwerte mit geringerer Messunsicherheit erzielt werden. Mit dem verwendeten Messaufbau lassen sich mittels PIV Geschwindigkeiten in einem Abstand zwischen 0 cm bis 2 cm und mittels Schattenwurf zwischen 0 cm bis 5 cm zur Schleifscheibenoberfläche messen. Im Ergebnis konnte erstmals der für die Kühlleistung relevante Parameter des Geschwindigkeitsverhältnisses zwischen KSS-Anströmung und Schleifscheibenoberflächengeschwindigkeit in situ gemessen werden. Es wurde festgestellt, dass eine aus der Literatur bekannte Verringerung der Kühleffizienz ab einem Geschwindigkeitsverhältnis von 0,8 mit einem Abprallen des KSS-Strahls beim Auftreffen auf die Schleifscheibe korreliert. In zukünftigen Untersuchungen ist zu klären, wie sich die hier gewonnenen Erkenntnisse zur Messfähigkeit und zum Strömungsverhalten auf den Schleifprozess mit Werkstück übertragen lassen.
- 24 September 2021
- Published by Optica Publishing Group in Applied Optics
- Vol. 60 (28) , 8716-8727
Stereoscopic particle image velocimetry in inhomogeneous refractive index fields of combustion flows
Particle image velocimetry (PIV) measurements in reactive flows are disturbed by inhomogeneous refractive index fields, which cause measurement deviations in particle positions due to light refraction. The resulting measurement errors are known for standard PIV, but the measurement errors for stereoscopic PIV are still unknown. Therefore, for comparison, the velocity errors for standard and stereoscopic PIV are analyzed in premixed propane flames with different Reynolds numbers. For this purpose, ray-tracing simulations based on the time-averaged inhomogeneous refractive index fields of the studied non-swirled flame flows measured by the background-oriented Schlieren technique are performed to quantify the resulting position errors of the particles. In addition, the performance of the volumetric self-calibration relevant to tomographic PIV is analyzed with respect to the remaining position errors of the particles within the flames. The position errors cause significant standard PIV errors of 2% for the velocity component radial to the burner symmetry axis. Stereoscopic PIV measurements result in measurement errors of up to 3% radial to the burner axis and 13% for the velocity component perpendicular to the measurement plane. Due to the lower refractive index gradients in the axial direction, no significant velocity errors are observed for the axial velocity component. For the investigated flame configurations, the position errors and velocity errors increase with the Reynolds numbers. However, this dependence needs to be verified for other flame configurations such as swirled flame flows.
- 24 September 2021
- Published by Optica Publishing Group in Applied Optics
- Vol. 60 (28) , 8716-8727
Stereoscopic particle image velocimetry in inhomogeneous refractive index fields of combustion flows
Particle image velocimetry (PIV) measurements in reactive flows are disturbed by inhomogeneous refractive index fields, which cause measurement deviations in particle positions due to light refraction. The resulting measurement errors are known for standard PIV, but the measurement errors for stereoscopic PIV are still unknown. Therefore, for comparison, the velocity errors for standard and stereoscopic PIV are analyzed in premixed propane flames with different Reynolds numbers. For this purpose, ray-tracing simulations based on the time-averaged inhomogeneous refractive index fields of the studied non-swirled flame flows measured by the background-oriented Schlieren technique are performed to quantify the resulting position errors of the particles. In addition, the performance of the volumetric self-calibration relevant to tomographic PIV is analyzed with respect to the remaining position errors of the particles within the flames. The position errors cause significant standard PIV errors of 2% for the velocity component radial to the burner symmetry axis. Stereoscopic PIV measurements result in measurement errors of up to 3% radial to the burner axis and 13% for the velocity component perpendicular to the measurement plane. Due to the lower refractive index gradients in the axial direction, no significant velocity errors are observed for the axial velocity component. For the investigated flame configurations, the position errors and velocity errors increase with the Reynolds numbers. However, this dependence needs to be verified for other flame configurations such as swirled flame flows.
- 15 November 2019
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 31 (2) , 027001
Revealing the impact of laser-induced breakdown on a gas flow
Laser-induced breakdown spectroscopy (LIBS) is an optical, and thus non-contact, but not non-invasive, measurement technique. Investigating the impact of laser-induced breakdown on a gas flow, combined LIBS and particle image velocimetry (PIV) measurements are performed. In the considered laminar air flow, the induced velocity field disturbance has an extent of about 0.7 cm with magnitudes up to 0.9 ms −1 . As a further result, the combination of LIBS with other measurement techniques or high-speed LIBS measurements are found to require a minimal time delay of about 500 s in order to ensure influence of the preceding LIBS pulse on the considered gas flow of about 10 % relative velocity deviation. For a reduction to 0 % relative velocity deviation a time delay of about 20 ms is estimated for the investigated flow. Smaller time delays may occur in turbulent flows or flows with higher velocities.
- 15 November 2019
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 31 (2) , 027001
Revealing the impact of laser-induced breakdown on a gas flow
Laser-induced breakdown spectroscopy (LIBS) is an optical, and thus non-contact, but not non-invasive, measurement technique. Investigating the impact of laser-induced breakdown on a gas flow, combined LIBS and particle image velocimetry (PIV) measurements are performed. In the considered laminar air flow, the induced velocity field disturbance has an extent of about 0.7 cm with magnitudes up to 0.9 ms −1 . As a further result, the combination of LIBS with other measurement techniques or high-speed LIBS measurements are found to require a minimal time delay of about 500 s in order to ensure influence of the preceding LIBS pulse on the considered gas flow of about 10 % relative velocity deviation. For a reduction to 0 % relative velocity deviation a time delay of about 20 ms is estimated for the investigated flow. Smaller time delays may occur in turbulent flows or flows with higher velocities.
- Open Access
- 9 September 2019
- Published by Springer Nature in Experiments in Fluids
- Vol. 60 (10) , 149
Particle image velocimetry in refractive index fields of combustion flows
Optical measurements inside reacting flows are often disturbed by refractive index fields, e.g., due to the strong density gradients in flames. Although occurring measurement errors due to light refraction are a known problem for certain particle image velocimetry (PIV) applications, only a qualitative analysis of the resulting measurement uncertainty inside flame flows has been carried out to date. As an important step forward, a measurement approach is proposed, which enables a quantification of the resulting measurement uncertainties due to light refraction. As an example, the measurement approach is applied to a premixed propane flame. The uncertainty analysis is based on the determination of occurring particle position errors due to light refraction inside the flame. For three different measurement planes, the velocity field is measured with PIV and the particle position errors are experimentally measured and verified by ray-tracing simulation based on the measured refractive index field, which is determined by the background-oriented Schlieren method. In the examined flow, maximal position errors amount up to 14 μm and yield significant systematic velocity errors of up to 4% and random velocity errors of up to 6%. In contrast to the systematic velocity error, the random velocity error varies significantly for the analyzed measurement planes inside the flame flow. Graphic
- 9 September 2019
- Published by Springer Nature in Experiments in Fluids
- Vol. 60 (10) , 149
Open AccessParticle image velocimetry in refractive index fields of combustion flows
Optical measurements inside reacting flows are often disturbed by refractive index fields, e.g., due to the strong density gradients in flames. Although occurring measurement errors due to light refraction are a known problem for certain particle image velocimetry (PIV) applications, only a qualitative analysis of the resulting measurement uncertainty inside flame flows has been carried out to date. As an important step forward, a measurement approach is proposed, which enables a quantification of the resulting measurement uncertainties due to light refraction. As an example, the measurement approach is applied to a premixed propane flame. The uncertainty analysis is based on the determination of occurring particle position errors due to light refraction inside the flame. For three different measurement planes, the velocity field is measured with PIV and the particle position errors are experimentally measured and verified by ray-tracing simulation based on the measured refractive index field, which is determined by the background-oriented Schlieren method. In the examined flow, maximal position errors amount up to 14 μm and yield significant systematic velocity errors of up to 4% and random velocity errors of up to 6%. In contrast to the systematic velocity error, the random velocity error varies significantly for the analyzed measurement planes inside the flame flow. Graphic