Eric Wisniewski
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Eric Wisniewski has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- John Power
Argonne National Laboratory, Argonne, Illinois 60439, USA
4 shared publications - Gerard Andonian
University of California Los Angeles
2 shared publications - Gwanghui Ha
Argonne National Laboratory, Argonne, Illinois 60439, USA
2 shared publications - James B. Rosenzweig
UCLA
2 shared publications - Scott Doran
Argonne Wakefield Accelerator, Argonne National Laboratory, Lemont, IL 60439, USA
2 shared publications - Seongyeol Kim
Argonne Wakefield Accelerator, Argonne National Laboratory, Lemont, IL 60439, USA
2 shared publications
Latest Publications
- Open Access
- 10 April 2024
- Published by MDPI AG in Instruments
- Vol. 8 (2) , 28
Drive Bunch Train for the Dielectric Trojan Horse Experiment at the Argonne Wakefield Accelerator
The recently demonstrated concept of the plasma photocathode, whereby a high-brightness bunch is initialized by laser ionization within a plasma wakefield acceleration bubble, is informally referred to as Trojan Horse wakefield acceleration. In a similar vein, the dielectric Trojan Horse concept incorporates a dielectric-lined waveguide to support a charged particle beam-driven accelerating mode and uses laser initiated ionization of neutral gas within the waveguide to generate a witness beam. One of the advantages of the dielectric Trojan Horse concept is the reduced requirements in terms of timing precision due to operation at a lower frequency. In this paper, we present experimental results on the generation and characterization of a four-bunch drive train for resonant excitation of wakefields in a cylindrical dielectric waveguide conducted at the Argonne Wakefield Accelerator facility. The results lay the foundation for the demonstration of a plasma photocathode scheme within a dielectric wakefield accelerating structure. Modifications to improve capture efficiency with improved beam transmission are suggested as well.
- 10 April 2024
- Published by MDPI AG in Instruments
- Vol. 8 (2) , 28
Open AccessDrive Bunch Train for the Dielectric Trojan Horse Experiment at the Argonne Wakefield Accelerator
The recently demonstrated concept of the plasma photocathode, whereby a high-brightness bunch is initialized by laser ionization within a plasma wakefield acceleration bubble, is informally referred to as Trojan Horse wakefield acceleration. In a similar vein, the dielectric Trojan Horse concept incorporates a dielectric-lined waveguide to support a charged particle beam-driven accelerating mode and uses laser initiated ionization of neutral gas within the waveguide to generate a witness beam. One of the advantages of the dielectric Trojan Horse concept is the reduced requirements in terms of timing precision due to operation at a lower frequency. In this paper, we present experimental results on the generation and characterization of a four-bunch drive train for resonant excitation of wakefields in a cylindrical dielectric waveguide conducted at the Argonne Wakefield Accelerator facility. The results lay the foundation for the demonstration of a plasma photocathode scheme within a dielectric wakefield accelerating structure. Modifications to improve capture efficiency with improved beam transmission are suggested as well.
- Open Access
- 28 November 2023
- Published by MDPI AG in Instruments
- Vol. 7 (4) , 48
Opportunities for Bright Beam Generation at the Argonne Wakefield Accelerator (AWA)
Bright electron beams have played a critical role in many recent advances in accelerator technology. Producing bright beams via photo-emission is ultimately limited by the mean transverse energy (MTE), which is determined by the photocathode. This paper discusses the opportunity to generate bright electron beams using an upgraded version of the Argonne Wakefield Accelerator (AWA) photo-injector. The focus of this study is to examine the optimal configurations of the AWA photo-injector to produce 100 pC with a ∼100 nm transverse emittance (corresponding to a 5D brightness A·m). The numerical optimization of the AWA photo-injector operating point, including realistic electromagnetic field maps, is presented for the different types of photocathodes under consideration.- 28 November 2023
- Published by MDPI AG in Instruments
- Vol. 7 (4) , 48
Open AccessOpportunities for Bright Beam Generation at the Argonne Wakefield Accelerator (AWA)
Bright electron beams have played a critical role in many recent advances in accelerator technology. Producing bright beams via photo-emission is ultimately limited by the mean transverse energy (MTE), which is determined by the photocathode. This paper discusses the opportunity to generate bright electron beams using an upgraded version of the Argonne Wakefield Accelerator (AWA) photo-injector. The focus of this study is to examine the optimal configurations of the AWA photo-injector to produce 100 pC with a ∼100 nm transverse emittance (corresponding to a 5D brightness A·m). The numerical optimization of the AWA photo-injector operating point, including realistic electromagnetic field maps, is presented for the different types of photocathodes under consideration. - Open Access
- 20 September 2023
- Published by MDPI AG in Instruments
- Vol. 7 (3) , 29
Demonstration of Autonomous Emittance Characterization at the Argonne Wakefield Accelerator
Transverse beam emittance plays a key role in the performance of high-brightness accelerators. Characterizing beam emittance is often carried out using a quadrupole scan, which fits beam matrix elements to experimental measurements using first-order beam dynamics. Despite its simplicity at face value, this procedure is difficult to automate due to practical limitations. Key issues that must be addressed include maintaining beam size measurement validity by keeping beams within the radius of diagnostic screens, ensuring that measurement fitting produces physically valid results, and accurately characterizing emittance uncertainty. We describe a demonstration of the Bayesian exploration technique towards solving this problem at the Argonne Wakefield Accelerator, enabling a turn-key, autonomous quadrupole scan tool that can be used to quickly measure beam emittances at various locations in accelerators with limited operator input.
- 20 September 2023
- Published by MDPI AG in Instruments
- Vol. 7 (3) , 29
Open AccessDemonstration of Autonomous Emittance Characterization at the Argonne Wakefield Accelerator
Transverse beam emittance plays a key role in the performance of high-brightness accelerators. Characterizing beam emittance is often carried out using a quadrupole scan, which fits beam matrix elements to experimental measurements using first-order beam dynamics. Despite its simplicity at face value, this procedure is difficult to automate due to practical limitations. Key issues that must be addressed include maintaining beam size measurement validity by keeping beams within the radius of diagnostic screens, ensuring that measurement fitting produces physically valid results, and accurately characterizing emittance uncertainty. We describe a demonstration of the Bayesian exploration technique towards solving this problem at the Argonne Wakefield Accelerator, enabling a turn-key, autonomous quadrupole scan tool that can be used to quickly measure beam emittances at various locations in accelerators with limited operator input.
- Open Access
Drive beam sources and longitudinal shaping techniques
Linear colliders are an attractive platform to explore high-precision physics of newly discovered particles. The recent significant progress in advanced accelerator technologies has motivated their applications to colliders which has been discussed in the {\sc alegro} workshop. In this paper we discuss one promising scheme, collinear wakefield acceleration. We especially discuss available drive and witness beam sources based on L and S-band radiofrequency technology, and also summarize available and forthcoming longitudinal shaping techniques to improve the overall acceleration efficiency via the transformer ratio.
Open AccessDrive beam sources and longitudinal shaping techniques
Linear colliders are an attractive platform to explore high-precision physics of newly discovered particles. The recent significant progress in advanced accelerator technologies has motivated their applications to colliders which has been discussed in the {\sc alegro} workshop. In this paper we discuss one promising scheme, collinear wakefield acceleration. We especially discuss available drive and witness beam sources based on L and S-band radiofrequency technology, and also summarize available and forthcoming longitudinal shaping techniques to improve the overall acceleration efficiency via the transformer ratio.
- Open Access
- 10 September 2019
- Published by MDPI AG in Instruments
- Vol. 3 (3) , 48
Externally Heated Hollow Cathode Arc Plasma Source for Experiments in Plasma Wakefield Acceleration
An externally heated, hollow cathode arc source was recommissioned at UCLA for use in experiments to drive plasma wakefields with shaped beams at the Argonne Wakefield Accelerator. The hollow cathode arc source provides a robust plasma column with a density in the – cm range while external heating of the cathode allows the plasma arc regime to be accessed with applied voltages down to 20 V. Overall source operating principals are described, along with time-resolved plasma current measurements and plasma density characterization with the use of a triple Langumir probe. The results show that relevant plasma densities that match facility beam parameters are readily achievable.- 10 September 2019
- Published by MDPI AG in Instruments
- Vol. 3 (3) , 48
Open AccessExternally Heated Hollow Cathode Arc Plasma Source for Experiments in Plasma Wakefield Acceleration
An externally heated, hollow cathode arc source was recommissioned at UCLA for use in experiments to drive plasma wakefields with shaped beams at the Argonne Wakefield Accelerator. The hollow cathode arc source provides a robust plasma column with a density in the – cm range while external heating of the cathode allows the plasma arc regime to be accessed with applied voltages down to 20 V. Overall source operating principals are described, along with time-resolved plasma current measurements and plasma density characterization with the use of a triple Langumir probe. The results show that relevant plasma densities that match facility beam parameters are readily achievable.