Yacine Djeghader
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yacine Djeghader has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
Zoubir Chelli
Mohamed-Cherif Messaadia University,Department of Electrical Engineering,Souk Ahras,ALGERIA
4 shared publications- Samira Boumous
Department of Electrical Engineering, Laboratory of Electrical Engineering and Renewable Energy, University of Souk Ahras, Souk Ahras, Algeria
3 shared publications - Zouhir Boumous
LEER Laboratory, University of Mohamed-Cherif Messaadia, Souk Ahras, Algeria
3 shared publications Abdelaziz Lakehal
2 shared publicationsA. Lakehal
University of of Souk ahras Algeria,Mecanical Engineering Department
1 shared publication- Abdelaziz Lakehal
University of Souk Ahras
1 shared publication
Latest Publications
- Open Access
- 1 September 2026
- Published by Institute of Advanced Engineering and Science in International Journal of Applied Power Engineering (IJAPE)
- Vol. 15 (3) , 1484-1498
Explainable AI for harmonic fingerprinting and voltage sag diagnosis in decentralized power grids: trends, challenges and future directions
The evolution of decentralized power grids has increased the complexity of power-quality monitoring, particularly harmonic fingerprinting and voltage sag diagnosis. Artificial intelligence improves disturbance detection and classification, yet black-box models limit transparency, engineering validation, and operator trust. This review synthesizes 108 selected studies on explainable artificial intelligence (XAI) for power-system diagnostics, focusing on SHapley Additive exPlanations (SHAP), local interpretable model-agnostic explanations (LIME), attention-based interpretability, visual analytics, and physics-informed learning. The review integrates harmonic fingerprinting with voltage sag diagnosis through their shared requirements for source attribution, temporal interpretation, physical consistency, and operator-oriented explanation. Four major deployment gaps are identified: data quality, computational latency, physical grounding, and trustworthiness. Future priorities include real-time embedded XAI, physics-informed neural networks, federated learning, standardized trustworthiness metrics, and adaptive model lifecycle management. The findings indicate that reliable autonomous diagnosis requires explainability to be integrated with predictive performance, electrical-system physics, computational efficiency, and field validation. This integration provides a stronger foundation for transparent, resilient, and trustworthy diagnostic systems in decentralized power grids.
- 1 September 2026
- Published by Institute of Advanced Engineering and Science in International Journal of Applied Power Engineering (IJAPE)
- Vol. 15 (3) , 1484-1498
Open AccessExplainable AI for harmonic fingerprinting and voltage sag diagnosis in decentralized power grids: trends, challenges and future directions
The evolution of decentralized power grids has increased the complexity of power-quality monitoring, particularly harmonic fingerprinting and voltage sag diagnosis. Artificial intelligence improves disturbance detection and classification, yet black-box models limit transparency, engineering validation, and operator trust. This review synthesizes 108 selected studies on explainable artificial intelligence (XAI) for power-system diagnostics, focusing on SHapley Additive exPlanations (SHAP), local interpretable model-agnostic explanations (LIME), attention-based interpretability, visual analytics, and physics-informed learning. The review integrates harmonic fingerprinting with voltage sag diagnosis through their shared requirements for source attribution, temporal interpretation, physical consistency, and operator-oriented explanation. Four major deployment gaps are identified: data quality, computational latency, physical grounding, and trustworthiness. Future priorities include real-time embedded XAI, physics-informed neural networks, federated learning, standardized trustworthiness metrics, and adaptive model lifecycle management. The findings indicate that reliable autonomous diagnosis requires explainability to be integrated with predictive performance, electrical-system physics, computational efficiency, and field validation. This integration provides a stronger foundation for transparent, resilient, and trustworthy diagnostic systems in decentralized power grids.
- Open Access
- 1 January 2026
- Published by GN1 Sistemas e Publicacoes Ltd. in ITEGAM-Journal of Engineering and Technology for Industrial Applications (ITEGAM-JETIA)
- Vol. 12 (61) , 1357-1367
CONTRIBUTION OF USING PV-STATCOM IN POWER QUALITY IMPROVEMENT
The increasing penetration of renewable energy sources in electrical distribution networks has introduced significant power quality challenges, including voltage fluctuations, harmonic distortion, poor power factor, and increased reactive power demand. Conventional mitigation techniques such as passive filters and capacitor banks often provide limited and inflexible compensation. This paper investigates the role of a photovoltaic-based Static Synchronous Compensator (PV-STATCOM) in enhancing power quality and system reliability. Implemented using a Voltage Source Converter (VSC), the PV-STATCOM operates as a shunt active filter capable of dynamically injecting or absorbing active and reactive power at the point of common coupling (PCC). An advanced control strategy based on the wavelet decoupling method is employed to effectively compensate reactive power and suppress harmonic distortions under nonlinear and variable load conditions. Simulation results obtained using MATLAB/Simulink demonstrate that the proposed system significantly improves power qualiry, reduces total harmonic distortion (THD), and achieves a near-unity power factor. These results confirm that PV-STATCOM technology provides an effective solution for maintaining IEEE power quality standards in renewable-integrated distribution systems.
- 1 January 2026
- Published by GN1 Sistemas e Publicacoes Ltd. in ITEGAM-Journal of Engineering and Technology for Industrial Applications (ITEGAM-JETIA)
- Vol. 12 (61) , 1357-1367
Open AccessCONTRIBUTION OF USING PV-STATCOM IN POWER QUALITY IMPROVEMENT
The increasing penetration of renewable energy sources in electrical distribution networks has introduced significant power quality challenges, including voltage fluctuations, harmonic distortion, poor power factor, and increased reactive power demand. Conventional mitigation techniques such as passive filters and capacitor banks often provide limited and inflexible compensation. This paper investigates the role of a photovoltaic-based Static Synchronous Compensator (PV-STATCOM) in enhancing power quality and system reliability. Implemented using a Voltage Source Converter (VSC), the PV-STATCOM operates as a shunt active filter capable of dynamically injecting or absorbing active and reactive power at the point of common coupling (PCC). An advanced control strategy based on the wavelet decoupling method is employed to effectively compensate reactive power and suppress harmonic distortions under nonlinear and variable load conditions. Simulation results obtained using MATLAB/Simulink demonstrate that the proposed system significantly improves power qualiry, reduces total harmonic distortion (THD), and achieves a near-unity power factor. These results confirm that PV-STATCOM technology provides an effective solution for maintaining IEEE power quality standards in renewable-integrated distribution systems.
- 1 January 2026
- Published by GN1 Sistemas e Publicacoes Ltd. in ITEGAM-Journal of Engineering and Technology for Industrial Applications (ITEGAM-JETIA)
- Vol. 12 (59) , 1673-1681
Enhancement of the DC Bus Voltage Control of a Shunt Active Power Filter Through Rooted Tree Optimization
Simulation results outcomes verify the proposed system's efficiency RTO. The PI controller is employed extensively in this work for controlling the DC-link voltage. Was used the anti-windup controller in this paper may not perform satisfactorily for fast changing load conditions in relation to overshoot, settling delay and undershoot. The DPC of shunt active power filter (SAPF) three phase is a successful approach to guarantee both stability and good performance for the DC link voltage. A new technique is offered in this work enhance the regulation of the DC link voltage using the DPC method. In order to illustrate the performance improvement, the root tree optimization (RTO) is employed to obtain optimal gains value for the windup prevention controller.
- 1 January 2026
- Published by GN1 Sistemas e Publicacoes Ltd. in ITEGAM-Journal of Engineering and Technology for Industrial Applications (ITEGAM-JETIA)
- Vol. 12 (59) , 1673-1681
Enhancement of the DC Bus Voltage Control of a Shunt Active Power Filter Through Rooted Tree Optimization
Simulation results outcomes verify the proposed system's efficiency RTO. The PI controller is employed extensively in this work for controlling the DC-link voltage. Was used the anti-windup controller in this paper may not perform satisfactorily for fast changing load conditions in relation to overshoot, settling delay and undershoot. The DPC of shunt active power filter (SAPF) three phase is a successful approach to guarantee both stability and good performance for the DC link voltage. A new technique is offered in this work enhance the regulation of the DC link voltage using the DPC method. In order to illustrate the performance improvement, the root tree optimization (RTO) is employed to obtain optimal gains value for the windup prevention controller.
- Open Access
- 26 October 2024
- Published by Polskie Towarzystwo Diagnostyki Technicznej in Diagnostyka
- Vol. 25 (4) , 1-8
Νew approach to power system stabilizer optimization techniques
Power System Stabilizers (PSS) are control devices used in synchronous generators to enhance the stability and damping of power systems by providing supplementary control signals to the generator excitation system. It’s come in various types, each designed to address specific stability issues...
- 26 October 2024
- Published by Polskie Towarzystwo Diagnostyki Technicznej in Diagnostyka
- Vol. 25 (4) , 1-8
Open AccessΝew approach to power system stabilizer optimization techniques
Power System Stabilizers (PSS) are control devices used in synchronous generators to enhance the stability and damping of power systems by providing supplementary control signals to the generator excitation system. It’s come in various types, each designed to address specific stability issues...
- Open Access
- 15 September 2024
- Published by Editura Academiei Române in REVUE ROUMAINE DES SCIENCES TECHNIQUES — SÉRIE ÉLECTROTECHNIQUE ET ÉNERGÉTIQUE
- Vol. 69 (3) , 293-297
MITIGATION OF POWER QUALITY PROBLEMS IN STEEL PLANTS USING STATIC SYNCHRONOUS COMPENSATOR
This paper focuses on mitigating various power quality issues from electric arc furnaces (EAF) in steel plants, including voltage flicker, sag, swell, and harmonics. Arc furnaces are recognized as one of the industry's most nonlinear electrically polluting loads. The proposed solution in this article to address all power quality issues caused by EAF is implementing a flexible power supply strategy known as a static synchronous compensator (STATCOM) for injecting reactive energy into the electrical grid. In this study, an experimental model of EAF is utilized based on real measurements of the variation of arc resistance and arc reactance during the melting phase. The pulse width modulation (PWM) technique is employed for current tracking feedback control to generate the required reactive current. A fuzzy logic controller (FLC) is employed for the DC bus.
- 15 September 2024
- Published by Editura Academiei Române in REVUE ROUMAINE DES SCIENCES TECHNIQUES — SÉRIE ÉLECTROTECHNIQUE ET ÉNERGÉTIQUE
- Vol. 69 (3) , 293-297
Open AccessMITIGATION OF POWER QUALITY PROBLEMS IN STEEL PLANTS USING STATIC SYNCHRONOUS COMPENSATOR
This paper focuses on mitigating various power quality issues from electric arc furnaces (EAF) in steel plants, including voltage flicker, sag, swell, and harmonics. Arc furnaces are recognized as one of the industry's most nonlinear electrically polluting loads. The proposed solution in this article to address all power quality issues caused by EAF is implementing a flexible power supply strategy known as a static synchronous compensator (STATCOM) for injecting reactive energy into the electrical grid. In this study, an experimental model of EAF is utilized based on real measurements of the variation of arc resistance and arc reactance during the melting phase. The pulse width modulation (PWM) technique is employed for current tracking feedback control to generate the required reactive current. A fuzzy logic controller (FLC) is employed for the DC bus.
- Open Access
- 21 June 2024
- Published by National Technical University Kharkiv Polytechnic Institute in Electrical Engineering & Electromechanics
- No. 4,p. 42-47
Contribution of using a photovoltaic unified power quality conditioner in power quality improvement
Introduction. With the increasing complexity of power systems and the integration of diverse energy sources, issues such as voltage sags, swells, and signal distortions have emerged as critical challenges. These power quality problems can result in equipment malfunction, production downtime, and financial losses for industries, as well as inconvenience and potential damage to electrical appliances in households. There is an urgent need for enhanced system efficiency. Methods. This objective is effectively achieved through the utilization of the newly proposed power theory, which is rooted in solar photovoltaic (PV) control, in conjunction with the Unified Power Quality Conditioner (UPQC). Purpose. The proposed method incorporates a modified synchronous reference frame scheme, coupled with a phase-locked loop mechanism. This control strategy enables the UPQC to effectively mitigate power quality issues. Novelty. PV-UPQC is utilized to uphold power integrity in the presence of diverse current and voltage distortions. This device, known as a multi-objective power conditioning apparatus, serves the purpose of maintaining power quality. PV-UPQC incorporates both a shunt and series voltage source converter, which are interconnected through a shared DC-link. Additionally, the PV system is interconnected at the DC-link of the UPQC in order to supply power to the load. Results. In this study, a novel approach is presented for controlling the UPQC, aiming to address power quality concerns such as unbalanced grid voltage and harmonic distortions and enabling us to control active and reactive power. References 16, tables 2, figures 15.
- 21 June 2024
- Published by National Technical University Kharkiv Polytechnic Institute in Electrical Engineering & Electromechanics
- No. 4,p. 42-47
Open AccessContribution of using a photovoltaic unified power quality conditioner in power quality improvement
Introduction. With the increasing complexity of power systems and the integration of diverse energy sources, issues such as voltage sags, swells, and signal distortions have emerged as critical challenges. These power quality problems can result in equipment malfunction, production downtime, and financial losses for industries, as well as inconvenience and potential damage to electrical appliances in households. There is an urgent need for enhanced system efficiency. Methods. This objective is effectively achieved through the utilization of the newly proposed power theory, which is rooted in solar photovoltaic (PV) control, in conjunction with the Unified Power Quality Conditioner (UPQC). Purpose. The proposed method incorporates a modified synchronous reference frame scheme, coupled with a phase-locked loop mechanism. This control strategy enables the UPQC to effectively mitigate power quality issues. Novelty. PV-UPQC is utilized to uphold power integrity in the presence of diverse current and voltage distortions. This device, known as a multi-objective power conditioning apparatus, serves the purpose of maintaining power quality. PV-UPQC incorporates both a shunt and series voltage source converter, which are interconnected through a shared DC-link. Additionally, the PV system is interconnected at the DC-link of the UPQC in order to supply power to the load. Results. In this study, a novel approach is presented for controlling the UPQC, aiming to address power quality concerns such as unbalanced grid voltage and harmonic distortions and enabling us to control active and reactive power. References 16, tables 2, figures 15.
- Open Access
- 28 April 2024
- Published by National Technical University Kharkiv Polytechnic Institute in Electrical Engineering & Electromechanics
- No. 3,p. 31-37
Artificial neural network and discrete wavelet transform for inter-turn short circuit and broken rotor bars faults diagnosis under various operating conditions
Introduction. This work presents a methodology for detecting inter-turn short circuit (ITSC) and broken rotor bars (BRB) fault in variable speed induction machine controlled by field oriented control. If any of these faults are not detected at an early stage, it may cause an unexpected shutdown of the industrial processes and significant financial losses. Purpose. For these reasons, it is important to develop a new diagnostic system to detect in a precautionary way the ITSC and BRB at various load condition. We propose the application of discrete wavelet transform to overcome the limitation of traditional technique for no-stationary signals. The novelty of the work consists in developing a diagnosis system that combines the advantages of both the discrete wavelet transform (DWT) and artificial neural network (ANN) to identify and diagnose defects, related to both ITSC and BRB faults. Methods. The suggested method involves analyzing the electromagnetic torque signal using DWT to calculate the stored energy at each level of decomposition. Then, this energy is applied to train neural network classifier. The accuracy of ANN based on DWT, was improved by testing different orthogonal wavelet functions on simulated signal. The selection process identified 5 pertinent wavelet energies, concluding that, Daubechies44 (db44) is the best suitable mother wavelet function for effectively detecting and classifying failures in machines. Results. We applied numerical simulations by MATLAB/Simulink software to demonstrate the validity of the suggested techniques in a closed loop induction motor drive. The obtained results prove that this method can identify and classify these types of faults under various loads of the machine. References 31, table 1, figures 9. Вступ. У цій роботі представлена методологія виявлення міжвиткового короткого замикання (ITSC) та несправності стрижнів ротора (BRB) в асинхронних машинах з регульованою швидкістю, керованих полеорієнтованим керуванням. Якщо будь-яка з цих несправностей не буде виявлена на ранній стадії, це може призвести до несподіваної зупинки виробничих процесів та значних фінансових втрат. Мета. З цих причин важливо розробити нову діагностичну систему для профілактичного виявлення ITSC та BRB за різних умов навантаження. Ми пропонуємо застосувати дискретне вейвлет перетворення, щоб подолати обмеження традиційної техніки для нестаціонарних сигналів. Новизна роботи полягає в розробці системи діагностики, що поєднує в собі як переваги дискретного вейвлет перетворення (DWT), так і штучної нейронної мережі (ANN) для виявлення та діагностики дефектів, пов'язаних як з несправностями ITSC, так і з BRB. Методи. Пропонований метод включає аналіз сигналу електромагнітного моменту, що крутить, з використанням DWT для розрахунку запасеної енергії на кожному рівні розкладання. Потім ця енергія застосовується на навчання класифікатора нейронної мережі. Точність ANN, заснованої на DWT, була підвищена за рахунок тестування різних ортогональних вейвлет функцій на сигналі, що моделюється. У процесі відбору було визначено п’ять відповідних енергій вейвлета, і було зроблено висновок, що Daubechies44 (db44) є найбільш підходящою материнською вейвлет функцією ефективного виявлення і класифікації відмов у машинах. Результати. Ми застосували чисельне моделювання за допомогою програмного забезпечення MATLAB/Simulink, щоб продемонструвати ефективність запропонованих методів приводу асинхронного двигуна із замкнутим контуром. Отримані результати доводять, що цей метод дозволяє виявити та класифікувати дані види несправностей при різних навантаженнях машини. Бібл. 31, табл. 1, рис. 9.
- 28 April 2024
- Published by National Technical University Kharkiv Polytechnic Institute in Electrical Engineering & Electromechanics
- No. 3,p. 31-37
Open AccessArtificial neural network and discrete wavelet transform for inter-turn short circuit and broken rotor bars faults diagnosis under various operating conditions
Introduction. This work presents a methodology for detecting inter-turn short circuit (ITSC) and broken rotor bars (BRB) fault in variable speed induction machine controlled by field oriented control. If any of these faults are not detected at an early stage, it may cause an unexpected shutdown of the industrial processes and significant financial losses. Purpose. For these reasons, it is important to develop a new diagnostic system to detect in a precautionary way the ITSC and BRB at various load condition. We propose the application of discrete wavelet transform to overcome the limitation of traditional technique for no-stationary signals. The novelty of the work consists in developing a diagnosis system that combines the advantages of both the discrete wavelet transform (DWT) and artificial neural network (ANN) to identify and diagnose defects, related to both ITSC and BRB faults. Methods. The suggested method involves analyzing the electromagnetic torque signal using DWT to calculate the stored energy at each level of decomposition. Then, this energy is applied to train neural network classifier. The accuracy of ANN based on DWT, was improved by testing different orthogonal wavelet functions on simulated signal. The selection process identified 5 pertinent wavelet energies, concluding that, Daubechies44 (db44) is the best suitable mother wavelet function for effectively detecting and classifying failures in machines. Results. We applied numerical simulations by MATLAB/Simulink software to demonstrate the validity of the suggested techniques in a closed loop induction motor drive. The obtained results prove that this method can identify and classify these types of faults under various loads of the machine. References 31, table 1, figures 9. Вступ. У цій роботі представлена методологія виявлення міжвиткового короткого замикання (ITSC) та несправності стрижнів ротора (BRB) в асинхронних машинах з регульованою швидкістю, керованих полеорієнтованим керуванням. Якщо будь-яка з цих несправностей не буде виявлена на ранній стадії, це може призвести до несподіваної зупинки виробничих процесів та значних фінансових втрат. Мета. З цих причин важливо розробити нову діагностичну систему для профілактичного виявлення ITSC та BRB за різних умов навантаження. Ми пропонуємо застосувати дискретне вейвлет перетворення, щоб подолати обмеження традиційної техніки для нестаціонарних сигналів. Новизна роботи полягає в розробці системи діагностики, що поєднує в собі як переваги дискретного вейвлет перетворення (DWT), так і штучної нейронної мережі (ANN) для виявлення та діагностики дефектів, пов'язаних як з несправностями ITSC, так і з BRB. Методи. Пропонований метод включає аналіз сигналу електромагнітного моменту, що крутить, з використанням DWT для розрахунку запасеної енергії на кожному рівні розкладання. Потім ця енергія застосовується на навчання класифікатора нейронної мережі. Точність ANN, заснованої на DWT, була підвищена за рахунок тестування різних ортогональних вейвлет функцій на сигналі, що моделюється. У процесі відбору було визначено п’ять відповідних енергій вейвлета, і було зроблено висновок, що Daubechies44 (db44) є найбільш підходящою материнською вейвлет функцією ефективного виявлення і класифікації відмов у машинах. Результати. Ми застосували чисельне моделювання за допомогою програмного забезпечення MATLAB/Simulink, щоб продемонструвати ефективність запропонованих методів приводу асинхронного двигуна із замкнутим контуром. Отримані результати доводять, що цей метод дозволяє виявити та класифікувати дані види несправностей при різних навантаженнях машини. Бібл. 31, табл. 1, рис. 9.
- Open Access
- 31 March 2024
- Published by Politechnika Lubelska in Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
- Vol. 14 (1) , 27-31
THE IMPACT OF LIGHTNING STRIKE ON HYBRID HIGH VOLTAGE OVERHEAD TRANSMISSION LINE – INSULATED GAS LINE
The electrical network is the set of elements where loads are connected to the generation plants by transmission lines. They can be either overhead or underground cables. A new technology has been introduced to replace these transmission lines with underground cables gas insulated line “GIL”. The latest has many advantages over underground cables and overhead transmission lines, such as low transmission losses, less capacitive load, reliability, personal safety, same operation as overhead lines and negligible electrical aging. GIL can handle much more power than overhead lines due to its large conductive area. GIL is the best for high voltage. In this paper, the simulation of lightning strike effects on a 400 kV hybrid transmission line located in the Wilaya of Setif in northern Algeria is presented in the absence and presence of line arresters and GIL arresters. The results of this paper can provide a rich and valuable theoretical reference for GIL simulation modeling and evaluation of lightning strike impact on hybrid overhead – GIL lines. Sieć elektryczna to zbiór elementów, w których obciążenia są połączone z elektrowniami za pomocą linii przesyłowych. Mogą to być linie napowietrzne lub podziemne. Nowa technologia została wprowadzona w celu zastąpienia tych linii przesyłowych podziemnymi kablami w izolacji gazowej "GIL". Najnowsza technologia ma wiele zalet w porównaniu z kablami podziemnymi i napowietrznymi liniami przesyłowymi, takich jak niskie straty przesyłowe, mniejsze obciążenie pojemnościowe, niezawodność, bezpieczeństwo obsługi, takie samo działanie jak w przypadku linii napowietrznych i znikome starzenie elektryczne. GIL może obsługiwać znacznie większą moc niż linie napowietrzne ze względu na dużą powierzchnię przewodzącą. GIL jest najlepszy dla wysokich napięć. W niniejszym artykule przedstawiono symulację skutków uderzenia pioruna w hybrydową linię przesyłową 400 kV zlokalizowaną w Wilaya, Setif w północnej Algierii w przypadku braku i obecności ograniczników liniowych i ograniczników GIL. Wyniki tego artykułu mogą stanowić bogate i cenne teoretyczne odniesienie do modelowania symulacji GIL i oceny wpływu uderzenia pioruna na hybrydowe linie napowietrzne – GIL.
- 31 March 2024
- Published by Politechnika Lubelska in Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
- Vol. 14 (1) , 27-31
Open AccessTHE IMPACT OF LIGHTNING STRIKE ON HYBRID HIGH VOLTAGE OVERHEAD TRANSMISSION LINE – INSULATED GAS LINE
The electrical network is the set of elements where loads are connected to the generation plants by transmission lines. They can be either overhead or underground cables. A new technology has been introduced to replace these transmission lines with underground cables gas insulated line “GIL”. The latest has many advantages over underground cables and overhead transmission lines, such as low transmission losses, less capacitive load, reliability, personal safety, same operation as overhead lines and negligible electrical aging. GIL can handle much more power than overhead lines due to its large conductive area. GIL is the best for high voltage. In this paper, the simulation of lightning strike effects on a 400 kV hybrid transmission line located in the Wilaya of Setif in northern Algeria is presented in the absence and presence of line arresters and GIL arresters. The results of this paper can provide a rich and valuable theoretical reference for GIL simulation modeling and evaluation of lightning strike impact on hybrid overhead – GIL lines. Sieć elektryczna to zbiór elementów, w których obciążenia są połączone z elektrowniami za pomocą linii przesyłowych. Mogą to być linie napowietrzne lub podziemne. Nowa technologia została wprowadzona w celu zastąpienia tych linii przesyłowych podziemnymi kablami w izolacji gazowej "GIL". Najnowsza technologia ma wiele zalet w porównaniu z kablami podziemnymi i napowietrznymi liniami przesyłowymi, takich jak niskie straty przesyłowe, mniejsze obciążenie pojemnościowe, niezawodność, bezpieczeństwo obsługi, takie samo działanie jak w przypadku linii napowietrznych i znikome starzenie elektryczne. GIL może obsługiwać znacznie większą moc niż linie napowietrzne ze względu na dużą powierzchnię przewodzącą. GIL jest najlepszy dla wysokich napięć. W niniejszym artykule przedstawiono symulację skutków uderzenia pioruna w hybrydową linię przesyłową 400 kV zlokalizowaną w Wilaya, Setif w północnej Algierii w przypadku braku i obecności ograniczników liniowych i ograniczników GIL. Wyniki tego artykułu mogą stanowić bogate i cenne teoretyczne odniesienie do modelowania symulacji GIL i oceny wpływu uderzenia pioruna na hybrydowe linie napowietrzne – GIL.
- Open Access
- 15 May 2023
- Published by Polskie Towarzystwo Diagnostyki Technicznej in Diagnostyka
- Vol. 24 (2) , 1-6
Study and analysis of the propagation of harmonics in electrical grid connected photovoltaic system
Renewable energy sources especially solar energy connected to an electrical grid system by using power electronic devices, known that devices degrade the power quality and especially generate harmonic currents. This article presents the study investigation and propagation of harmonics in the...
- 15 May 2023
- Published by Polskie Towarzystwo Diagnostyki Technicznej in Diagnostyka
- Vol. 24 (2) , 1-6
Open AccessStudy and analysis of the propagation of harmonics in electrical grid connected photovoltaic system
Renewable energy sources especially solar energy connected to an electrical grid system by using power electronic devices, known that devices degrade the power quality and especially generate harmonic currents. This article presents the study investigation and propagation of harmonics in the...
- 1 December 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Investigation of Harmonics Problems in Grid Connected PV-Wind-Battery for Household Applications
The aim of this study is to focuses on a hybrid system (photovoltaic-wind) with a storage system (battery) used for power supply household. Hybrid power systems using renewable sources can improve efficiency, reliability and security while reducing operating costs. However, the big challenge of application hybrid power system is satisfying the load demand under different constraints. While hybrid sources offer a complex solution, they offer flexibility, an operational flexibility and an attractive purchase price. We use maximum power point tracking command (MPPT) with boost converter for photovoltaic panels, and another MPPT for wind system, the pulse width modulation control (PWM) for the inverter and a DC/DC buck-boost converter for the battery. The simulations results obtained at level of load shows the degradation of waveforms of currents and voltages with high values of total harmonic distortion (THD), and poor power factor.
- 1 December 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Investigation of Harmonics Problems in Grid Connected PV-Wind-Battery for Household Applications
The aim of this study is to focuses on a hybrid system (photovoltaic-wind) with a storage system (battery) used for power supply household. Hybrid power systems using renewable sources can improve efficiency, reliability and security while reducing operating costs. However, the big challenge of application hybrid power system is satisfying the load demand under different constraints. While hybrid sources offer a complex solution, they offer flexibility, an operational flexibility and an attractive purchase price. We use maximum power point tracking command (MPPT) with boost converter for photovoltaic panels, and another MPPT for wind system, the pulse width modulation control (PWM) for the inverter and a DC/DC buck-boost converter for the battery. The simulations results obtained at level of load shows the degradation of waveforms of currents and voltages with high values of total harmonic distortion (THD), and poor power factor.