Patryk Wetoszka
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Patryk Wetoszka has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Kamil Białek
Signalling and Telecommunications Laboratory, Railway Research Institute, 50 Chłopickiego St., 04-275 Warsaw, Poland
7 shared publications - Jacek Paś
Faculty of Electronic, Military University of Technology of Warsaw, ul. Urbanowicza 2, 00-908 Warszawa, Poland
6 shared publications - Adam Rosiński
Division of Air Transport Engineering and Teleinformatics, Faculty of Transport, Warsaw University of Technology, 75 Koszykowa St., 00-662 Warsaw, Poland
4 shared publications - Michał Mazur
Wojskowa Akademia Techniczna
2 shared publications - Tomasz Klimczak
Department of Threat Prevention, Fire University, Juliusza Słowackiego 52/54 St., 01-629 Warsaw, Poland
2 shared publications - Jarosław Łukasiak
Division of Electronic Systems Exploitations, Institute of Electronic Systems, Faculty of Electronics, Military University of Technology, 2 Gen. S. Kaliski St, 00-908 Warsaw, Poland
1 shared publication
Latest Publications
- Open Access
- 16 September 2026
- Published by Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne in Eksploatacja i Niezawodność – Maintenance and Reliability
Operation of integrated electronic security systems in a distorted railway electromagnetic environment – selected security aspects
This research paper reviews issues associated with identifying the impact of electromagnetic interference (EI) sources within an environment where integrated electronic security systems (IESS) are operated. IESS are operated under diverse environmental conditions. They are exposed to internal and external EIs both natural and artificial. The authors conducted experiments within a natural environment. They enabled identifying these interference sources. The outcome of field environmental tests, followed by the modelling of an IESS reliability and operation process was a conclusion that there are methods to minimise encountered EIs. The application of technical solutions within internal IESS structures increases the probability of a system remaining in a state of full fitness. The considerations in this article allowed to develop a method to assess the impacts of EIs on IESS. This method can be successfully employed to examine the operation process in other electronic systems and devices.
- 16 September 2026
- Published by Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne in Eksploatacja i Niezawodność – Maintenance and Reliability
Open AccessOperation of integrated electronic security systems in a distorted railway electromagnetic environment – selected security aspects
This research paper reviews issues associated with identifying the impact of electromagnetic interference (EI) sources within an environment where integrated electronic security systems (IESS) are operated. IESS are operated under diverse environmental conditions. They are exposed to internal and external EIs both natural and artificial. The authors conducted experiments within a natural environment. They enabled identifying these interference sources. The outcome of field environmental tests, followed by the modelling of an IESS reliability and operation process was a conclusion that there are methods to minimise encountered EIs. The application of technical solutions within internal IESS structures increases the probability of a system remaining in a state of full fitness. The considerations in this article allowed to develop a method to assess the impacts of EIs on IESS. This method can be successfully employed to examine the operation process in other electronic systems and devices.
- Open Access
- 16 July 2025
- Published by MDPI AG in Electronics
- Vol. 14 (14) , 2851
Operation of Electronic Security Systems in an Environment Exposed to Conducted and Radiated Electromagnetic Interference
This paper presents an analysis of the impact of conducted and radiated electromagnetic interference affecting the electrical circuits of electronic security systems (ESS) operating over wide areas. The Earth’s electromagnetic environment is heavily distorted by intended and unintended (stationary or non-stationary) sources of radiation. The occurrence of electromagnetic interference in a given environment where an ESS is in use is the cause of damage or malfunction of the entire system or its individual components, e.g., detectors, modules, control panels, etc. In this article, the authors conducted an assessment of the electromagnetic environment where ESS are operated and conducted studies of selected sources of interference. For selected ESS structures, they developed models of the impact of conducted and radiated interference on the process of using these systems in a given environment. For selected technical structures of ESS, the authors of this article developed models of the operation process. They also carried out a computer simulation to determine the impact of natural and artificial electromagnetic interference occurring on the process of using these systems in a given environment over a wide area. The considerations carried out in this article are summarized in the conclusions chapter about the process of using ESS in a distorted electromagnetic environment.
- 16 July 2025
- Published by MDPI AG in Electronics
- Vol. 14 (14) , 2851
Open AccessOperation of Electronic Security Systems in an Environment Exposed to Conducted and Radiated Electromagnetic Interference
This paper presents an analysis of the impact of conducted and radiated electromagnetic interference affecting the electrical circuits of electronic security systems (ESS) operating over wide areas. The Earth’s electromagnetic environment is heavily distorted by intended and unintended (stationary or non-stationary) sources of radiation. The occurrence of electromagnetic interference in a given environment where an ESS is in use is the cause of damage or malfunction of the entire system or its individual components, e.g., detectors, modules, control panels, etc. In this article, the authors conducted an assessment of the electromagnetic environment where ESS are operated and conducted studies of selected sources of interference. For selected ESS structures, they developed models of the impact of conducted and radiated interference on the process of using these systems in a given environment. For selected technical structures of ESS, the authors of this article developed models of the operation process. They also carried out a computer simulation to determine the impact of natural and artificial electromagnetic interference occurring on the process of using these systems in a given environment over a wide area. The considerations carried out in this article are summarized in the conclusions chapter about the process of using ESS in a distorted electromagnetic environment.
- 9 December 2023
- Published by Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne in Eksploatacja i Niezawodność – Maintenance and Reliability
- Vol. 26 (1)
Method for Assessing Reliability of the Power Supply System for Electronic Security Systems of Intelligent Buildings Taking Into Account External Natural Interference
The article presents issues related to the reliability of power supply for electronic security devices in intelligent buildings. These systems function under varied environmental conditions and are exposed to external or internal natural and artificial interference; lightning, in particular. The authors conducted actual experimental tests of two surge arresters that are used to protect against a lightning impulse. As a result of conducted tests, followed by reliability and operational modelling, it was concluded that their use in internal connection structures increased the probability of a system staying in a state of full fitness. All of the deliberations included in the article enabled developing a new method for assessing the power supply continuity in electronic security systems of intelligent buildings, taking into account external natural interference. This method can also be applied to assess the power supply continuity in other electronic systems and devices.
- 9 December 2023
- Published by Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne in Eksploatacja i Niezawodność – Maintenance and Reliability
- Vol. 26 (1)
Method for Assessing Reliability of the Power Supply System for Electronic Security Systems of Intelligent Buildings Taking Into Account External Natural Interference
The article presents issues related to the reliability of power supply for electronic security devices in intelligent buildings. These systems function under varied environmental conditions and are exposed to external or internal natural and artificial interference; lightning, in particular. The authors conducted actual experimental tests of two surge arresters that are used to protect against a lightning impulse. As a result of conducted tests, followed by reliability and operational modelling, it was concluded that their use in internal connection structures increased the probability of a system staying in a state of full fitness. All of the deliberations included in the article enabled developing a new method for assessing the power supply continuity in electronic security systems of intelligent buildings, taking into account external natural interference. This method can also be applied to assess the power supply continuity in other electronic systems and devices.
- Open Access
Selected Issues Associated with the Operational and Power Supply Reliability of Fire Alarm Systems
The article reviews issues associated with the use of electronic fire alarm systems (FAS). They are operated in various environments and buildings with varying volumes. FAS have to function properly under different operating conditions associated with their operation, as well as power supply and information inflow. Due to their functions, i.e., ensuring the safety of people, vehicles, logistics bases, airports, etc., FAS have to exhibit an appropriately organized reliability structure associated with their implementation and power supply. Operational studies involving FAS operated in various facilities were conducted to this end. The authors determined damage and recovery time intensities. FAS reliability indicators were also determined. The article presents graphs associated with developing the energy balance for selected FAS. The graphs are consistent with the latest and applicable legal regulations. The next stage of the work related to this article was developing an FAS operation process model and conducting computer simulations in order to determine reliability indicators. Such an approach to the FAS operation process enables a rational selection of technical and organizational solutions aimed at guaranteeing reliability in the course of executing operational tasks associated with ensuring fire safety. FAS operational analysis, developing balance graphs and models, as well as the computer simulation, enabled inferring conclusions that might be useful to the process of engineering and operating such systems.
Open AccessSelected Issues Associated with the Operational and Power Supply Reliability of Fire Alarm Systems
The article reviews issues associated with the use of electronic fire alarm systems (FAS). They are operated in various environments and buildings with varying volumes. FAS have to function properly under different operating conditions associated with their operation, as well as power supply and information inflow. Due to their functions, i.e., ensuring the safety of people, vehicles, logistics bases, airports, etc., FAS have to exhibit an appropriately organized reliability structure associated with their implementation and power supply. Operational studies involving FAS operated in various facilities were conducted to this end. The authors determined damage and recovery time intensities. FAS reliability indicators were also determined. The article presents graphs associated with developing the energy balance for selected FAS. The graphs are consistent with the latest and applicable legal regulations. The next stage of the work related to this article was developing an FAS operation process model and conducting computer simulations in order to determine reliability indicators. Such an approach to the FAS operation process enables a rational selection of technical and organizational solutions aimed at guaranteeing reliability in the course of executing operational tasks associated with ensuring fire safety. FAS operational analysis, developing balance graphs and models, as well as the computer simulation, enabled inferring conclusions that might be useful to the process of engineering and operating such systems.
- Open Access
- 15 August 2022
- Published by MDPI AG in Electronics
- Vol. 11 (16) , 2554
Assessment of the Impact of Emitted Radiated Interference Generated by a Selected Rail Traction Unit on the Operating Process of Trackside Video Monitoring Systems
The article presents a method for assessing the impact of radiated electromagnetic interference generated by a selected rail traction unit on the operational process of trackside video monitoring systems (VMS). VMSs operated throughout an extensive railway area are responsible for the safety of people and property transport processes. Emissions of radiated electromagnetic interference generated in an unintended manner by traction vehicles within a railway line lead to interference in the VMS operating process. Based on the knowledge of actual VMS operating process data, spectral characteristics and values of individual components of disturbing signals occurring in the emissions of radiated electromagnetic interference, it is possible to determine the parameters of damage intensities for the devices and elements of this system. Using that data enables determining the VMS reliability parameters within its operating system, for an extensive railway area. The article’s authors first discussed the basic issues associated with VMS, followed by analysing the topic’s current status. They also presented issues related to measuring interference radiated within a rail area, developed a selected operational process model, and determined selected operational indicators for the structures in question. The paper ends with conclusions.
- 15 August 2022
- Published by MDPI AG in Electronics
- Vol. 11 (16) , 2554
Open AccessAssessment of the Impact of Emitted Radiated Interference Generated by a Selected Rail Traction Unit on the Operating Process of Trackside Video Monitoring Systems
The article presents a method for assessing the impact of radiated electromagnetic interference generated by a selected rail traction unit on the operational process of trackside video monitoring systems (VMS). VMSs operated throughout an extensive railway area are responsible for the safety of people and property transport processes. Emissions of radiated electromagnetic interference generated in an unintended manner by traction vehicles within a railway line lead to interference in the VMS operating process. Based on the knowledge of actual VMS operating process data, spectral characteristics and values of individual components of disturbing signals occurring in the emissions of radiated electromagnetic interference, it is possible to determine the parameters of damage intensities for the devices and elements of this system. Using that data enables determining the VMS reliability parameters within its operating system, for an extensive railway area. The article’s authors first discussed the basic issues associated with VMS, followed by analysing the topic’s current status. They also presented issues related to measuring interference radiated within a rail area, developed a selected operational process model, and determined selected operational indicators for the structures in question. The paper ends with conclusions.
- Open Access
- 11 June 2022
- Published by Instytut Badan Gospodarczych / Institute of Economic Research in Journal of Automation, Electronics and Electrical Engineering
- Vol. 4 (1) , 29-35
Effects of independent magnetic fields in the very low frequency range elf generated by selected elements of an electric traction unit on the ambient environment and electronic systems
The article presents research results and issues related to of magnetic component of electromagnetic field on the environment and electronic systems used in the electric traction unit. The electronic systems used and built into an electric power unit are operated in a wide variety of environmental conditions. Electrical and electronic systems with different purposes coexist on the vast railroad area, and an important operational problem, apart from environmental changes in which these technical objects are operated, is also the issue of external and internal electromagnetic compatibility. Depending on the extent of the railroad area, the intentional or unintentional emission of electromagnetic fields over a range of frequencies, the construction, technical configuration and method of ensuring electromagnetic compatibility for the electrical and electronic systems in use and electronic systems in use are different. It is necessary to skillfully and appropriately use all measures included in the electromagnetic compatibility pyramid to ensure the appropriate level of robustness, immunity and susceptibility of the above mentioned systems. Due to the impact and propagation of electromagnetic waves in the railroad environment, individual frequency bands of interfering signals should be considered separately for the whole spectrum of interfering signals. The article presents the results of research on the generated magnetic fields from the very low frequency (ELF) range by electric power units. Diagnosing the electromagnetic environment over the entire frequency range enables the realization and proper protection of the electrical and electronic systems used in an electric power train from the effects of unintended interference. Knowledge of the parameters of interfering signals - e.g. amplitude, frequency range, spectrum, etc. - will enable designers of electrical and electronic train systems systems to properly protect these facilities from adverse environmental conditions.
- 11 June 2022
- Published by Instytut Badan Gospodarczych / Institute of Economic Research in Journal of Automation, Electronics and Electrical Engineering
- Vol. 4 (1) , 29-35
Open AccessEffects of independent magnetic fields in the very low frequency range elf generated by selected elements of an electric traction unit on the ambient environment and electronic systems
The article presents research results and issues related to of magnetic component of electromagnetic field on the environment and electronic systems used in the electric traction unit. The electronic systems used and built into an electric power unit are operated in a wide variety of environmental conditions. Electrical and electronic systems with different purposes coexist on the vast railroad area, and an important operational problem, apart from environmental changes in which these technical objects are operated, is also the issue of external and internal electromagnetic compatibility. Depending on the extent of the railroad area, the intentional or unintentional emission of electromagnetic fields over a range of frequencies, the construction, technical configuration and method of ensuring electromagnetic compatibility for the electrical and electronic systems in use and electronic systems in use are different. It is necessary to skillfully and appropriately use all measures included in the electromagnetic compatibility pyramid to ensure the appropriate level of robustness, immunity and susceptibility of the above mentioned systems. Due to the impact and propagation of electromagnetic waves in the railroad environment, individual frequency bands of interfering signals should be considered separately for the whole spectrum of interfering signals. The article presents the results of research on the generated magnetic fields from the very low frequency (ELF) range by electric power units. Diagnosing the electromagnetic environment over the entire frequency range enables the realization and proper protection of the electrical and electronic systems used in an electric power train from the effects of unintended interference. Knowledge of the parameters of interfering signals - e.g. amplitude, frequency range, spectrum, etc. - will enable designers of electrical and electronic train systems systems to properly protect these facilities from adverse environmental conditions.
- 19 September 2019
- Published by Springer Nature
- p. 31-40
Analysis of Elimination of Electromagnetic Disturbances at Power Ports of Railway Equipment
- 19 September 2019
- Published by Springer Nature
- p. 31-40
Analysis of Elimination of Electromagnetic Disturbances at Power Ports of Railway Equipment