Ruth Edry
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ruth Edry has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Albert Dahan
Centre for Human Drug Research, 2333CL Leiden, The Netherlands
1 shared publication - Christian H. Martini
Department of Anaesthesiology, Leiden University Medical Centre, Leiden, the Netherlands
1 shared publication - Daniel I. Sessler
Outcomes Research Consortium®, Houston, TX, USA; Center for Outcomes Research and Department of Anesthesiology, UTHealth, Houston, TX, USA
1 shared publication Dror Aizenbud
1 shared publication- Erik Olofsen
Department of Anesthesiology, Leiden University Medical Center, Leiden, The Netherlands
1 shared publication - Eveline L. A. van Dorp
Department of Anesthesiology, Leiden University Medical Center, Leiden, The Netherlands
1 shared publication
Latest Publications
- Open Access
Lessons Learned from Evaluation of LLM based Multi-agents in Safer Therapy Recommendation
Therapy recommendation for chronic patients with multimorbidity is challenging due to risks of treatment conflicts. Existing decision support systems face scalability limitations. Inspired by the way in which general practitioners (GP) manage multimorbidity patients, occasionally convening multidisciplinary team (MDT) collaboration, this study investigated the feasibility and value of using a Large Language Model (LLM)-based multi-agent system (MAS) for safer therapy recommendations. We designed a single agent and a MAS framework simulating MDT decision-making by enabling discussion among LLM agents to resolve medical conflicts. The systems were evaluated on therapy planning tasks for multimorbidity patients using benchmark cases. We compared MAS performance with single-agent approaches and real-world benchmarks. An important contribution of our study is the definition of evaluation metrics that go beyond the technical precision and recall and allow the inspection of clinical goals met and medication burden of the proposed advices to a gold standard benchmark. Our results show that with current LLMs, a single agent GP performs as well as MDTs. The best-scoring models provide correct recommendations that address all clinical goals, yet the advices are incomplete. Some models also present unnecessary medications, resulting in unnecessary conflicts between medication and conditions or drug-drug interactions.
Open AccessLessons Learned from Evaluation of LLM based Multi-agents in Safer Therapy Recommendation
Therapy recommendation for chronic patients with multimorbidity is challenging due to risks of treatment conflicts. Existing decision support systems face scalability limitations. Inspired by the way in which general practitioners (GP) manage multimorbidity patients, occasionally convening multidisciplinary team (MDT) collaboration, this study investigated the feasibility and value of using a Large Language Model (LLM)-based multi-agent system (MAS) for safer therapy recommendations. We designed a single agent and a MAS framework simulating MDT decision-making by enabling discussion among LLM agents to resolve medical conflicts. The systems were evaluated on therapy planning tasks for multimorbidity patients using benchmark cases. We compared MAS performance with single-agent approaches and real-world benchmarks. An important contribution of our study is the definition of evaluation metrics that go beyond the technical precision and recall and allow the inspection of clinical goals met and medication burden of the proposed advices to a gold standard benchmark. Our results show that with current LLMs, a single agent GP performs as well as MDTs. The best-scoring models provide correct recommendations that address all clinical goals, yet the advices are incomplete. Some models also present unnecessary medications, resulting in unnecessary conflicts between medication and conditions or drug-drug interactions.
- Open Access
- 20 July 2019
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 34 (4) , 629-641
Does nociception monitor-guided anesthesia affect opioid consumption? A systematic review of randomized controlled trials
Monitors that estimate nociception during anesthesia may be used to guide opioid and other analgesics administration to optimize anesthesia care and possibly outcome. We reviewed the literature to evaluate current evidence of the effect of nociception-guided management over standard anesthesia practice during surgery. A systematic review of the literature on the effect of nociception monitoring on anesthesia practice was conducted. Reports were eligible if they compared nociception-guided anesthesia to standard practice during surgery. Primary endpoint of this review is intraoperative opioid consumption. Secondary endpoints included hemodynamic control, postoperative pain and pain treatment. We identified 12 randomized controlled trials that compared one of five different nociception monitoring techniques to standard anesthesia care. Most studies were single center studies of small sample size. Six studies reported intraoperative opioid consumption as primary outcome. There was considerable variability with respect to surgical procedure and anesthesia technique. For nociception monitors that were investigated by more than one study, analysis of the pooled data was performed. The surgical plethysmographic index was the only monitor for which an intra operative opioid sparing effect was found. For the other monitors, either no effect was detected, or pooled analysis could not be performed due to paucity of study data. On secondary outcomes, no consistent effect of nociception-guided anesthesia could be established. Although some nociception monitors show promising results, no definitive conclusions regarding the effect of nociception monitoring on intraoperative opioid consumption or other anesthesia related outcome can be drawn. Clinical trial number PROSPERO ID 102913.
- 20 July 2019
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 34 (4) , 629-641
Open AccessDoes nociception monitor-guided anesthesia affect opioid consumption? A systematic review of randomized controlled trials
Monitors that estimate nociception during anesthesia may be used to guide opioid and other analgesics administration to optimize anesthesia care and possibly outcome. We reviewed the literature to evaluate current evidence of the effect of nociception-guided management over standard anesthesia practice during surgery. A systematic review of the literature on the effect of nociception monitoring on anesthesia practice was conducted. Reports were eligible if they compared nociception-guided anesthesia to standard practice during surgery. Primary endpoint of this review is intraoperative opioid consumption. Secondary endpoints included hemodynamic control, postoperative pain and pain treatment. We identified 12 randomized controlled trials that compared one of five different nociception monitoring techniques to standard anesthesia care. Most studies were single center studies of small sample size. Six studies reported intraoperative opioid consumption as primary outcome. There was considerable variability with respect to surgical procedure and anesthesia technique. For nociception monitors that were investigated by more than one study, analysis of the pooled data was performed. The surgical plethysmographic index was the only monitor for which an intra operative opioid sparing effect was found. For the other monitors, either no effect was detected, or pooled analysis could not be performed due to paucity of study data. On secondary outcomes, no consistent effect of nociception-guided anesthesia could be established. Although some nociception monitors show promising results, no definitive conclusions regarding the effect of nociception monitoring on intraoperative opioid consumption or other anesthesia related outcome can be drawn. Clinical trial number PROSPERO ID 102913.
- Open Access
- 1 October 2015
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 123 (4) , 978
Suboptimal Protocol?
- 1 October 2015
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 123 (4) , 978
Open AccessSuboptimal Protocol?
- 9 July 2013
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 27 (6) , 659-668
Monitoring the nociception level: a multi-parameter approach
The aim of the present study was to develop and validate an objective index for nociception level (NoL) of patients under general anesthesia, based on a combination of multiple physiological parameters. Twenty-five patients scheduled for elective surgery were enrolled. For clinical reference of NoL, the combined index of stimulus and analgesia was defined as a composite of the surgical stimulus level and a scaled effect-site concentration of opioid. The physiological parameters heart rate, heart rate variability (0.15–0.4 Hz band power), plethysmograph wave amplitude, skin conductance level, number of skin conductance fluctuations, and their time derivatives, were extracted. Two techniques to incorporate these parameters into a single index representing the NoL have been proposed: NoLlinear, based on an ordinary linear regression, and NoLnon-linear, based on a non-linear Random Forest regression. NoLlinear and NoLnon-linear significantly increased after moderate to severe noxious stimuli (Wilcoxon rank test, p < 0.01), while the individual parameters only partially responded. Receiver operating curve analysis showed that NoL index based on both techniques better discriminated noxious and non-noxious surgical events [area under curve (AUC) = 0.97] compared with individual parameters (AUC = 0.56–0.74). NoLnon-linear better ranked the level of nociception compared with NoLlinear (R = 0.88 vs. 0.77, p < 0.01). These results demonstrate the superiority of multi-parametric approach over any individual parameter in the evaluation of nociceptive response. In addition, advanced non-linear technique may have an advantage over ordinary linear regression for computing NoL index. Further research will define the usability of the NoL index as a clinical tool to assess the level of nociception during general anesthesia.
- 9 July 2013
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 27 (6) , 659-668
Monitoring the nociception level: a multi-parameter approach
The aim of the present study was to develop and validate an objective index for nociception level (NoL) of patients under general anesthesia, based on a combination of multiple physiological parameters. Twenty-five patients scheduled for elective surgery were enrolled. For clinical reference of NoL, the combined index of stimulus and analgesia was defined as a composite of the surgical stimulus level and a scaled effect-site concentration of opioid. The physiological parameters heart rate, heart rate variability (0.15–0.4 Hz band power), plethysmograph wave amplitude, skin conductance level, number of skin conductance fluctuations, and their time derivatives, were extracted. Two techniques to incorporate these parameters into a single index representing the NoL have been proposed: NoLlinear, based on an ordinary linear regression, and NoLnon-linear, based on a non-linear Random Forest regression. NoLlinear and NoLnon-linear significantly increased after moderate to severe noxious stimuli (Wilcoxon rank test, p < 0.01), while the individual parameters only partially responded. Receiver operating curve analysis showed that NoL index based on both techniques better discriminated noxious and non-noxious surgical events [area under curve (AUC) = 0.97] compared with individual parameters (AUC = 0.56–0.74). NoLnon-linear better ranked the level of nociception compared with NoLlinear (R = 0.88 vs. 0.77, p < 0.01). These results demonstrate the superiority of multi-parametric approach over any individual parameter in the evaluation of nociceptive response. In addition, advanced non-linear technique may have an advantage over ordinary linear regression for computing NoL index. Further research will define the usability of the NoL index as a clinical tool to assess the level of nociception during general anesthesia.
- 13 June 2012
- Vol. 104, 79-84
Entropy values of intellectually-disabled and normal children undergoing deep intravenous sedation for dental treatment.
Intravenous sedation is an efficient method to facilitate dental treatment delivery to uncooperative children. Entropy is used for monitoring anesthetic depth. Nonetheless, scarce data is found on entropy monitoring in intellectually-disabled patients during sedation. This comparative study set out to evaluate entropy values of normal and intellectually-disabled patients during the steady state period of deep sedation and awakening. Additionally, the study aimed to establish whether normal and intellectually-disabled patients reached a comparable clinically assessed state of sedation and the doses of total anesthetic drugs administered. 30 patients were included in the study and divided into two groups: 16 normal and 14 intellectually-disabled children. Ages ranged between 2 to 16 years. All patients were assigned to receive dental treatment under intravenous sedation. Entropy tracings were recorded for all patients. Clinical sedation level was assessed every 5 minutes. Drug administration was guided clinically. The anesthesiologist was blinded to entropy tracing. Although sedation levels assessed clinically were similar between groups, entropy values were significantly lower in the group of intellectually-disabled patients both during sedation steady state and waking. The total amount of anesthetic drugs administered to normal patients was higher compared to intellectually-disabled patients. In this study, entropy monitoring was found to be a more sensitive modality for assessing intra-operative brain activity during steady state sedation compared to clinical assessment of sedation. Despite similar clinical assessment of sedation level, brain activity was lower in the intellectually-disabled group as were their anesthetic drug requirements. We conclude that intellectually-disabled patients may need less anesthetic drugs to reach a good level of sedation. Whether the lower level of brain activity during sedation, reflected by lower entropy tracings, is characteristic of the intellectually disabled warrants additional studies.
- 13 June 2012
- Vol. 104, 79-84
Entropy values of intellectually-disabled and normal children undergoing deep intravenous sedation for dental treatment.
Intravenous sedation is an efficient method to facilitate dental treatment delivery to uncooperative children. Entropy is used for monitoring anesthetic depth. Nonetheless, scarce data is found on entropy monitoring in intellectually-disabled patients during sedation. This comparative study set out to evaluate entropy values of normal and intellectually-disabled patients during the steady state period of deep sedation and awakening. Additionally, the study aimed to establish whether normal and intellectually-disabled patients reached a comparable clinically assessed state of sedation and the doses of total anesthetic drugs administered. 30 patients were included in the study and divided into two groups: 16 normal and 14 intellectually-disabled children. Ages ranged between 2 to 16 years. All patients were assigned to receive dental treatment under intravenous sedation. Entropy tracings were recorded for all patients. Clinical sedation level was assessed every 5 minutes. Drug administration was guided clinically. The anesthesiologist was blinded to entropy tracing. Although sedation levels assessed clinically were similar between groups, entropy values were significantly lower in the group of intellectually-disabled patients both during sedation steady state and waking. The total amount of anesthetic drugs administered to normal patients was higher compared to intellectually-disabled patients. In this study, entropy monitoring was found to be a more sensitive modality for assessing intra-operative brain activity during steady state sedation compared to clinical assessment of sedation. Despite similar clinical assessment of sedation level, brain activity was lower in the intellectually-disabled group as were their anesthetic drug requirements. We conclude that intellectually-disabled patients may need less anesthetic drugs to reach a good level of sedation. Whether the lower level of brain activity during sedation, reflected by lower entropy tracings, is characteristic of the intellectually disabled warrants additional studies.