Hugo Touw
Research Subjects
Hugo Touw has a total of 56 co-authors. Here are the top co-authors by number of shared publications:
Pieter R. Tuinman
Amsterdam Leiden Intensive Care Focused Echography (ALIFE) Amsterdam the Netherlands
2 shared publications- A. E. Schuitemaker
Department of Anaesthesiology, Amsterdam UMC, Vrije Universiteit Amsterdam, Amsterdam Cardiovascular Sciences, De Boelelaan 1117, 1081 HV, Amsterdam, The Netherlands
1 shared publication Amne Mousa
Amsterdam Leiden Intensive Care Focused Echography (ALIFE) Amsterdam the Netherlands
1 shared publication- Ana-Maria Ioan
Hospital Universitario Fundación Jiménez Díaz, Madrid, Spain
1 shared publication - Anne Ottenbros
Radboud University, Radboud Institute for Biology and Environmental Science, Heyendaalseweg 135, 6525 AJ, Nijmegen, The Netherlands
1 shared publication Carlos V. Elzo Kraemer
Amsterdam Leiden Intensive Care Focused Echography (ALIFE) Amsterdam the Netherlands
1 shared publication
Latest Publications
- Top Cited PapersOpen Access
- 1 February 2026
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 52 (2) , 131-139
Environmental impact of cataract surgery and strategies for mitigation: a life cycle assessment in an academic hospital
Purpose: To identify the main environmental hotspots of cataract surgery and evaluates strategies to reduce its environmental impact and to compare process-based and monetary value-based methodologies for environmental assessment. Setting: Radboud University Medical Center, Nijmegen, the Netherlands. Design: Cradle-to-grave life cycle assessment (LCA) following ISO 14040/44 guidelines. Methods: The environmental impact of phacoemulsification cataract surgery was assessed, including all processes, products, and equipment used in the operating room. Key contributors to human health and ecosystem damage were identified. A monetary value-based analysis was performed using the same inventory data to compare methodological approaches. Results: Disposables (35%) and patient travel (31%) were the largest contributors to the environmental impact. Immediate sequential bilateral cataract surgery (ISBCS) reduced the impact by 19%, and simplifying surgical kits achieved a 10% reduction. Additional reductions were observed with renewable energy (−12%) and sustainable transportation (−8%). The monetary value-based approach yielded a fourfold higher carbon footprint than the process-based LCA, while identifying similar hotspots. Conclusions: The main environmental hotspots of cataract surgery were patient travel and disposable products. The most effective mitigation strategy to reduce the carbon footprint is implementing ISBCS. Additional mitigation strategies include reducing the use of disposable products, encouraging sustainable travel options, and switching to renewable energy. These findings highlight opportunities for ophthalmologists to contribute to more sustainable surgical care.
- 1 February 2026
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 52 (2) , 131-139
Top Cited PapersOpen AccessEnvironmental impact of cataract surgery and strategies for mitigation: a life cycle assessment in an academic hospital
Purpose: To identify the main environmental hotspots of cataract surgery and evaluates strategies to reduce its environmental impact and to compare process-based and monetary value-based methodologies for environmental assessment. Setting: Radboud University Medical Center, Nijmegen, the Netherlands. Design: Cradle-to-grave life cycle assessment (LCA) following ISO 14040/44 guidelines. Methods: The environmental impact of phacoemulsification cataract surgery was assessed, including all processes, products, and equipment used in the operating room. Key contributors to human health and ecosystem damage were identified. A monetary value-based analysis was performed using the same inventory data to compare methodological approaches. Results: Disposables (35%) and patient travel (31%) were the largest contributors to the environmental impact. Immediate sequential bilateral cataract surgery (ISBCS) reduced the impact by 19%, and simplifying surgical kits achieved a 10% reduction. Additional reductions were observed with renewable energy (−12%) and sustainable transportation (−8%). The monetary value-based approach yielded a fourfold higher carbon footprint than the process-based LCA, while identifying similar hotspots. Conclusions: The main environmental hotspots of cataract surgery were patient travel and disposable products. The most effective mitigation strategy to reduce the carbon footprint is implementing ISBCS. Additional mitigation strategies include reducing the use of disposable products, encouraging sustainable travel options, and switching to renewable energy. These findings highlight opportunities for ophthalmologists to contribute to more sustainable surgical care.
- Open Access
- 16 October 2025
- Published by Wiley in Journal of Clinical Ultrasound
- Vol. 54 (3) , 635-641
Thoracic Ultrasound–Related Management Change: Predictors and the Role of Operator Certification (Secondary Analysis of UltraMAN )
Objectives: To investigate which patient characteristics, ultrasound operator certification level, and thoracic ultrasound (TUS) examination findings are associated with a TUS‐induced change in clinical management in adult intensive care unit (ICU) patients. Design: Post hoc analysis of a prospective international observational study (UltraMan study) on the impact of thoracic ultrasound on clinical management of critically ill patients. The first TUS examinations of each patient included in the study were included in this analysis. Multivariable logistic regression was performed to identify which patient characteristic(s), operator certification level, or TUS‐related factors were significantly associated with a change in management. Interventions: None. Measurements and Main Results: The first TUS examinations of each of the 534 patients were included in this analysis. TUS led to management changes in almost half of the patients in whom a TUS was performed (44.6%). TUS‐induced management changes were significantly associated with patient characteristics. Specifically, a medical history of cardiovascular disease demonstrated a significant association (OR: 1.73; 95% CI: 1.12–2.68). In terms of TUS examination findings, hypovolemia demonstrated a significant association with a change in management (OR: 2.05; 95% CI: 1.10–3.80). No significant association was found between ultrasound operator certification level and changes in management driven by TUS. Conclusions: This study indicates that TUS was associated with management changes in 44.6% of ICU patients, with stronger associations in those with cardiovascular disease and hypovolemia, and no detectable effect of operator certification in adjusted analyses. As a post hoc analysis of an observational cohort, these findings warrant cautious interpretation and underscore the importance of competency‐based training and quality assurance.
- 16 October 2025
- Published by Wiley in Journal of Clinical Ultrasound
- Vol. 54 (3) , 635-641
Open AccessThoracic Ultrasound–Related Management Change: Predictors and the Role of Operator Certification (Secondary Analysis of UltraMAN )
Objectives: To investigate which patient characteristics, ultrasound operator certification level, and thoracic ultrasound (TUS) examination findings are associated with a TUS‐induced change in clinical management in adult intensive care unit (ICU) patients. Design: Post hoc analysis of a prospective international observational study (UltraMan study) on the impact of thoracic ultrasound on clinical management of critically ill patients. The first TUS examinations of each patient included in the study were included in this analysis. Multivariable logistic regression was performed to identify which patient characteristic(s), operator certification level, or TUS‐related factors were significantly associated with a change in management. Interventions: None. Measurements and Main Results: The first TUS examinations of each of the 534 patients were included in this analysis. TUS led to management changes in almost half of the patients in whom a TUS was performed (44.6%). TUS‐induced management changes were significantly associated with patient characteristics. Specifically, a medical history of cardiovascular disease demonstrated a significant association (OR: 1.73; 95% CI: 1.12–2.68). In terms of TUS examination findings, hypovolemia demonstrated a significant association with a change in management (OR: 2.05; 95% CI: 1.10–3.80). No significant association was found between ultrasound operator certification level and changes in management driven by TUS. Conclusions: This study indicates that TUS was associated with management changes in 44.6% of ICU patients, with stronger associations in those with cardiovascular disease and hypovolemia, and no detectable effect of operator certification in adjusted analyses. As a post hoc analysis of an observational cohort, these findings warrant cautious interpretation and underscore the importance of competency‐based training and quality assurance.
- Top Cited PapersOpen Access
- 8 October 2024
- Published by Springer Nature in Intensive Care Medicine
- Vol. 50 (11) , 1729-1739
Environmental sustainability in intensive care: the path forward. An ESICM Green Paper
Purpose The European Society of Intensive Care Medicine (ESICM) Green Paper aims to address the challenge of environmental sustainability in intensive care and proposes actionable strategies for integrating sustainability into intensive care unit (ICU) stakeholder actions. Methods The ESICM Executive Committee appointed a task force of topic experts and ESICM committee representatives to develop the ESICM Green Paper. The task force convened biweekly from January to June 2024, identifying key domains for environmental sustainability and prioritizing actions. Drafts were iteratively refined and approved by the ESICM Executive Committee. Results Climate change will impact activities in intensive care in many ways, but also the impact of ICU activities on the environment is considerable; drivers for this include extensive resource use and waste generation in ICUs from energy consumption, use of disposable items, and advanced therapies for critically ill patients. The ESICM Green Paper outlines a structured approach for ICUs to reduce their environmental impact, emphasizing energy efficiency, waste reduction, and sustainable procurement. Furthermore, it endorses the need for awareness and education among healthcare professionals, integration of sustainability into research, and sustainable policies within scientific societies. Conclusions The ESICM Green Paper reviewed the relevance of climate change to intensive care and provided suggestions for clinical practice, research, education, and ESICM organizational domains. It underscores that reducing intensive care's ecological footprint can coexist with high-quality patient care. Promoting a resilient, responsible healthcare system is a joint responsibility of all ICU stakeholders.
- 8 October 2024
- Published by Springer Nature in Intensive Care Medicine
- Vol. 50 (11) , 1729-1739
Top Cited PapersOpen AccessEnvironmental sustainability in intensive care: the path forward. An ESICM Green Paper
Purpose The European Society of Intensive Care Medicine (ESICM) Green Paper aims to address the challenge of environmental sustainability in intensive care and proposes actionable strategies for integrating sustainability into intensive care unit (ICU) stakeholder actions. Methods The ESICM Executive Committee appointed a task force of topic experts and ESICM committee representatives to develop the ESICM Green Paper. The task force convened biweekly from January to June 2024, identifying key domains for environmental sustainability and prioritizing actions. Drafts were iteratively refined and approved by the ESICM Executive Committee. Results Climate change will impact activities in intensive care in many ways, but also the impact of ICU activities on the environment is considerable; drivers for this include extensive resource use and waste generation in ICUs from energy consumption, use of disposable items, and advanced therapies for critically ill patients. The ESICM Green Paper outlines a structured approach for ICUs to reduce their environmental impact, emphasizing energy efficiency, waste reduction, and sustainable procurement. Furthermore, it endorses the need for awareness and education among healthcare professionals, integration of sustainability into research, and sustainable policies within scientific societies. Conclusions The ESICM Green Paper reviewed the relevance of climate change to intensive care and provided suggestions for clinical practice, research, education, and ESICM organizational domains. It underscores that reducing intensive care's ecological footprint can coexist with high-quality patient care. Promoting a resilient, responsible healthcare system is a joint responsibility of all ICU stakeholders.
- 1 June 2021
- Published by Wolters Kluwer Health in European Journal of Anaesthesiology
- Vol. 38 (6) , 673-675
Continuous remote monitoring to detect critical early warning scores after abdominal surgery
- 1 June 2021
- Published by Wolters Kluwer Health in European Journal of Anaesthesiology
- Vol. 38 (6) , 673-675
Continuous remote monitoring to detect critical early warning scores after abdominal surgery
- Open Access
- 1 October 2019
- Published by Springer Nature
Continuous remote monitoring to detect critical early warning scores in patients after abdominal surgery
- 1 October 2019
- Published by Springer Nature
Open AccessContinuous remote monitoring to detect critical early warning scores in patients after abdominal surgery
- Open Access
- 16 September 2019
- Published by Mattioli1885 in The Ultrasound Journal
- Vol. 11 (1) , 1-8
Routine lung ultrasound to detect postoperative pulmonary complications following major abdominal surgery: a prospective observational feasibility study
Background: Postoperative pulmonary complications after major abdominal surgery are associated with adverse outcome. The diagnostic accuracy of chest X-rays (CXR) to detect pulmonary disorders is limited. Alternatively, lung ultrasound (LUS) is an established evidence-based point-of-care diagnostic modality which outperforms CXR in critical care. However, its feasibility and diagnostic ability for postoperative pulmonary complications following abdominal surgery are unknown. In this prospective observational feasibility study, we included consecutive patients undergoing major abdominal surgery with an intermediate or high risk developing postoperative pulmonary complications according to the Assess Respiratory risk In Surgical patients in CATalonia (ARISCAT) score. LUS was routinely performed on postoperative days 0–3 by a researcher blinded for CXR or other clinical findings. Then, reports were drawn up for LUS concerning feasibility and detection rates of postoperative pulmonary complications. CXRs were performed on demand according to daily clinical practice. Subsequently, we compared LUS and CXR findings. Results: A total of 98 consecutive patients with an ARISCAT score of 41 (34–49) were included in the study. LUS was feasible in all patients. In 94 (95%) patients, LUS detected one or more postoperative pulmonary complications during the first four postoperative days. On day 0, LUS detected 31 out of 43 patients (72.1%) with one or more postoperative pulmonary complications, compared to 13 out of 36 patients (36.1%) with 1 or more postoperative pulmonary complications detected with CXR RR 2.0 (95 CI [1.24–3.20]) ( p = 0.004). The number of discordant observations between both modalities was high for atelectasis 23 (43%) and pleural effusion 29 (54%), but not for pneumothorax, respiratory infection and pulmonary edema 8 (15%), 3 (5%), and 5 (9%), respectively. Conclusions: This study shows that LUS is highly feasible and frequently detects postoperative pulmonary complications after major abdominal surgery. Discordant observations in atelectasis and pleural effusions for LUS and CXR can be explained by a superior diagnostic ability of LUS in detecting these conditions. The effects of LUS as primary imaging modality on patient outcome should be evaluated in future studies.
- 16 September 2019
- Published by Mattioli1885 in The Ultrasound Journal
- Vol. 11 (1) , 1-8
Open AccessRoutine lung ultrasound to detect postoperative pulmonary complications following major abdominal surgery: a prospective observational feasibility study
Background: Postoperative pulmonary complications after major abdominal surgery are associated with adverse outcome. The diagnostic accuracy of chest X-rays (CXR) to detect pulmonary disorders is limited. Alternatively, lung ultrasound (LUS) is an established evidence-based point-of-care diagnostic modality which outperforms CXR in critical care. However, its feasibility and diagnostic ability for postoperative pulmonary complications following abdominal surgery are unknown. In this prospective observational feasibility study, we included consecutive patients undergoing major abdominal surgery with an intermediate or high risk developing postoperative pulmonary complications according to the Assess Respiratory risk In Surgical patients in CATalonia (ARISCAT) score. LUS was routinely performed on postoperative days 0–3 by a researcher blinded for CXR or other clinical findings. Then, reports were drawn up for LUS concerning feasibility and detection rates of postoperative pulmonary complications. CXRs were performed on demand according to daily clinical practice. Subsequently, we compared LUS and CXR findings. Results: A total of 98 consecutive patients with an ARISCAT score of 41 (34–49) were included in the study. LUS was feasible in all patients. In 94 (95%) patients, LUS detected one or more postoperative pulmonary complications during the first four postoperative days. On day 0, LUS detected 31 out of 43 patients (72.1%) with one or more postoperative pulmonary complications, compared to 13 out of 36 patients (36.1%) with 1 or more postoperative pulmonary complications detected with CXR RR 2.0 (95 CI [1.24–3.20]) ( p = 0.004). The number of discordant observations between both modalities was high for atelectasis 23 (43%) and pleural effusion 29 (54%), but not for pneumothorax, respiratory infection and pulmonary edema 8 (15%), 3 (5%), and 5 (9%), respectively. Conclusions: This study shows that LUS is highly feasible and frequently detects postoperative pulmonary complications after major abdominal surgery. Discordant observations in atelectasis and pleural effusions for LUS and CXR can be explained by a superior diagnostic ability of LUS in detecting these conditions. The effects of LUS as primary imaging modality on patient outcome should be evaluated in future studies.