ACArianna Cruciani

Arianna Cruciani

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Arianna Cruciani has a total of 32 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Efficacy of Robot-Assisted Gait Training Combined with Robotic Balance Training in Subacute Stroke Patients: A Randomized Clinical Trial

    by Irene Aprile, Carmela Conte, Arianna Cruciani, Cristiano Pecchioli, Letizia Castelli, Sabina Insalaco, Marco Germanotta, Chiara Iacovelli

    Recently, the use of robotic technology in gait and balance rehabilitation of stroke patients has been introduced, with positive results. The purpose of this study was to evaluate the effectiveness of robotic gait and trunk rehabilitation compared to robotic gait training alone on balance, activities, and participation measures in patients with subacute stroke. The study was a randomized, controlled, single blind, parallel group clinical trial. Thirty-six patients with first ischemic or hemorrhagic stroke event were enrolled, and they were randomized in two groups: Gait Group (GG), where they received only robotic treatment for gait rehabilitation through an end-effector system, and Gait/Trunk Group (GTG) where they performed end-effector gait rehabilitation and balance with a robotic platform, 3 times/week for 12 sessions/month. At the end of the study, there was an improvement in balance ability in both groups. Instead, the lower limb muscle strength and muscle tone significantly improved only in the GTG group, where we found a significant reduction in the trunk oscillations and displacement during dynamic exercises more than the GG group. The robotic platform which was added to the gait robotic treatment offers more intense and controlled training of the trunk that positively influences the tone and strength of lower limb muscles.


  • The reaching movement in breast cancer survivors: Attention to the principles of rehabilitation

    by Teresa Paolucci, Serena Vincenza Capobianco, Arianna Valeria Bai, Adriana Bonifacino, Francesco Agostini, Andrea Bernetti, Marco Paoloni, Arianna Cruciani, Valter Santilli, Luca Padua, et al.


  • Top Cited Papers
    Open Access

    Reliability, validity and discriminant ability of a robotic device for finger training in patients with subacute stroke

    by the FDG Robotic Rehabilitation Group, Marco Germanotta, Valerio Gower, Dionysia Papadopoulou, Arianna Cruciani, Cristiano Pecchioli, Rita Mosca, Gabriele Speranza, Catuscia Falsini, Francesca Cecchi, et al.

    Background: The majority of stroke survivors experiences significant hand impairments, as weakness and spasticity, with a severe impact on the activity of daily living. To objectively evaluate hand deficits, quantitative measures are needed. The aim of this study is to assess the reliability, the validity and the discriminant ability of the instrumental measures provided by a robotic device for hand rehabilitation, in a sample of patients with subacute stroke.Material and methods: In this study, 120 patients with stroke and 40 controls were enrolled. Clinical evaluation included finger flexion and extension strength (using the Medical Research Council, MRC), finger spasticity (using the Modified Ashworth Scale, MAS) and motor control and dexterity during ADL performance (by means of the Frenchay Arm Test, FAT). Robotic evaluations included finger flexion and extension strength, muscle tone at rest, and instrumented MAS and Modified Tardieu Scale. Subjects were evaluated twice, one day apart, to assess the test-retest reliability of the robotic measures, using the Intraclass Correlation Coefficient (ICC). To estimate the response stability, the standard errors of measurement and the minimum detectable change (MDC) were also calculated. Validity was assessed by analyzing the correlations between the robotic metrics and the clinical scales, using the Spearman’s Correlation Coefficient (r). Finally, we investigated the ability of the robotic measures to distinguish between patients with stroke and healthy subjects, by means of Mann-Whitney U tests.Results: All the investigated measures were able to discriminate patients with stroke from healthy subjects (p < 0.001). Test-retest reliability was found to be excellent for finger strength (in both flexion and extension) and muscle tone, with ICCs higher than 0.9. MDCs were equal to 10.6 N for finger flexion, 3.4 N for finger extension, and 14.3 N for muscle tone. Conversely, test-retest reliability of the spasticity measures was poor. Finally, finger strength (in both flexion and extension) was correlated with the clinical scales (r of about 0.7 with MRC, and about 0.5 with FAT).Discussion: Finger strength (in both flexion and extension) and muscle tone, as provided by a robotic device for hand rehabilitation, are reliable and sensitive measures. Moreover, finger strength is strongly correlated with clinical scales. Changes higher than the obtained MDC in these robotic measures could be considered as clinically relevant and used to assess the effect of a rehabilitation treatment in patients with subacute stroke.


  • Open Access

    Improving the Efficiency of Robot-Mediated Rehabilitation by Using a New Organizational Model: An Observational Feasibility Study in an Italian Rehabilitation Center

    by Irene Aprile, Cristiano Pecchioli, Simona Loreti, Arianna Cruciani, Luca Padua, Marco Germanotta

    Robotic rehabilitation is a promising way to restore upper limb function, but new organizational models are crucial in order to improve its sustainability. We aimed to analyze the feasibility of a robot-Assisted REhabilitation Area (robotAREA) equipped with four devices, using a new organizational model in which one physiotherapist supervises up to four patients. In 33 days, 60 patients were treated in the robotAREA. Two hundred fifty-five rehabilitation sessions were analyzed, each including two, three, or four patients supervised by one physiotherapist (the R2, R3, and R4 group, respectively). For each session, the duration of (a) setup, (b) training, (c) supervision, (d) session closure, and participant satisfaction were measured. For each patient, upper limb impairment, disability, mobility, and comorbidity were recorded. The time of training in the R4 group was lower by only 2 and 3 min compared to the R2 and R3 groups, respectively, while the supervision significantly changed between the R2, R3, and R4 groups. No differences were observed in satisfaction. Moreover, according to the logistic regression analysis, when the mean disability of the group is moderate, four patients can be supervised by one physiotherapist. These results suggest that the proposed model is feasible, and the mean disability of the group could influence the proper physiotherapist/patient ratio.


  • Open Access

    Upper Limb Robotics in Rehabilitation: An Approach to Select the Devices, Based on Rehabilitation Aims, and Their Evaluation in a Feasibility Study

    by Irene Aprile, Arianna Cruciani, Marco Germanotta, Valerio Gower, Cristiano Pecchioli, Davide Cattaneo, Federica Vannetti, Luca Padua, Furio Gramatica

    Robot-mediated therapy is a viable approach for upper limb rehabilitation. The upper limb is a highly complex segment and the identification of the appropriate devices capable of rehabilitating it globally (from the shoulder to the hand) in clinical practice is crucial. In this work, we aimed: (i) to describe an approach used in identifying a set of technological and robotic devices to globally treat the upper limb, and (ii) to evaluate the feasibility of the identified set in clinical practice. Using an ad-hoc form, a multidisciplinary team identified a set of four robotic and sensor-based devices to treat globally the upper limb. Then, 30 stroke patients were enrolled and assigned to two groups: the robotic group (RG), where patients were treated with the robotic set, or the conventional group (CG). All patients were evaluated before and after the treatment. In the RG the patients used all the devices (one in each rehabilitation session); the treatment was well accepted, without drop-outs or adverse events. Using a multidisciplinary approach, we identified a set of technological and robotic devices to treat the upper limb globally, and then we experimented to ascertain its feasibility, in a pilot study. Robotics offers a considerable number of devices for rehabilitation that should be selected according to rehabilitation aims and feasibility in clinical practice.