CMChanho Moon

Chanho Moon

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Chanho Moon has a total of 26 co-authors. Here are the top co-authors by number of shared publications:

  • Takuma Yamada

    Faculty of Arts and Science, Kyushu University, Fukuoka 819-0395

    2 shared publications
  • Akihide Fujisawa

    Research Institute for Applied Mechanics, Kyushu University, Kasuga-City, Japan

    1 shared publication
  • D. Di Matteo

    Interdisciplinary Graduate School of Engineering Sciences, Kyushu University, Kasuga, Japan

    1 shared publication
  • Daiki Nishimura

    Interdisciplinary Graduate School of Engineering Sciences, Kyushu University, Kasuga-city, Japan

    1 shared publication
  • Donato Di Matteo

    Interdisciplinary Graduate School of Engineering Sciences, Kyushu University, Kasuga 816-8580

    1 shared publication
  • Gunsu S. Yun

    Pohang University of Science and Technology

    1 shared publication

Latest Publications

  • Open Access

    First application of a ball-pen probe for direct measurements of plasma potential and nonlinear fluctuation dynamics in a linear helicon plasma

    by D. Di Matteo, T. Yamada, Y. Nagashima, J. Adamek, J. Cavalier, R. Namimatsu, H. Chung, C. Moon

  • Design and commissioning of a high-sensitivity multi-channel magnetic probe system for electromagnetic fluctuation measurements in linear plasma device

    by Seongbin Hong, Hyung-Gu Kang, Donato Di Matteo, Jaemin Yoo, Junghee Kim, Hiroe Igami, Takuma Yamada, Chanho Moon, Gunsu S. Yun

    A high-sensitivity multi-channel magnetic probe system was developed and commissioned for electromagnetic fluctuation measurements in the PANTA linear plasma device. The diagnostic head consists of two 300-turn pickup coils and a Langmuir probe positioned between them, enabling simultaneous measurements of magnetic and electrostatic fluctuations at nearly the same radial position. The probe was designed to enhance the induced voltage from weak magnetic fluctuations while allowing radial scanning and rotational adjustment without breaking the vacuum condition. In the present configuration, signals were acquired at 1 MHz without additional hardware amplification or analog filtering, so that the intrinsic probe design determined the sensitivity and usable frequency range. The performance of the probe system was evaluated by Helmholtz-coil calibration, LCR-meter impedance characterization, and COMSOL-based electromagnetic characterization. The probe response was experimentally calibrated over the 1–100 kHz range, and the LCR-meter measurement confirmed that no pronounced resonance-like behavior appeared below 100 kHz. COMSOL-based simulations were used to estimate the coil-to-coil coupling between adjacent pickup coils. Using this calibrated probe system, weak magnetic fluctuations in PANTA plasmas were successfully measured and directly compared with density-sensitive electrostatic fluctuation signals. Radially resolved power spectra, coherence, and cross-phase measurements demonstrate that the developed probe system provides a reliable experimental platform for quantitative studies of electromagnetic fluctuations and their relation to electrostatic fluctuations in linear magnetized plasmas.

  • Open Access

    The first observation of 4D tomography measurement of plasma structures and fluctuations

    by Chanho Moon, Kotaro Yamasaki, Yoshihiko Nagashima, Shigeru Inagaki, Takeshi Ido, Takuma Yamada, Naohiro Kasuya, Yusuke Kosuga, Makoto Sasaki, Yuichi Kawachi, et al.

    A tomography system is installed as one of the diagnostics of new age to examine the three-dimensional characteristics of structure and dynamics including fluctuations of a linear magnetized helicon plasma. The system is composed of three sets of tomography components located at different axial positions. Each tomography component can measure the two-dimensional emission profile over the entire cross-section of plasma at different axial positions in a sufficient temporal scale to detect the fluctuations. The four-dimensional measurement including time and space successfully obtains the following three results that have never been found without three-dimensional measurement: (1) in the production phase, the plasma front propagates from the antenna toward the end plate with an ion acoustic velocity. (2) In the steady state, the plasma emission profile is inhomogeneous, and decreases along the axial direction in the presence of the azimuthal asymmetry. Furthermore, (3) in the steady state, the fluctuations should originate from a particular axial position located downward from the helicon antenna.