M. R. Rai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
M. R. Rai has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
M. T. Popat
Nuffield Department of Anaesthetics, John Radcliffe Hospital, Oxford, UK
2 shared publicationsA. Dering
Specialist Registrars
1 shared publicationC. Verghese
Consultant, Department of Anaesthesia, Royal Berkshire Hospital, London Road, Reading RG15 AN, UK
1 shared publicationM. Popat
1 shared publicationR. Russell
1 shared publicationS.H. Lua
1 shared publication
Latest Publications
- 18 February 2014
- Published by Wiley in Anaesthesia
- Vol. 69 (3) , 199-203
The humble bougie…forty years and still counting?
- 18 February 2014
- Published by Wiley in Anaesthesia
- Vol. 69 (3) , 199-203
The humble bougie…forty years and still counting?
- 16 May 2011
- Published by Wiley in Anaesthesia
- Vol. 66 (6) , 528-529
A reply
- 22 November 2010
- Published by Wiley in Anaesthesia
- Vol. 66 (1) , 1-3
Evaluation of airway equipment: man or manikin?
- 22 November 2010
- Published by Wiley in Anaesthesia
- Vol. 66 (1) , 1-3
Evaluation of airway equipment: man or manikin?
- 1 July 2005
- Published by Elsevier in International Journal of Obstetric Anesthesia
- Vol. 14 (3) , 219-222
Antenatal anaesthetic assessment of high-risk pregnancy: a survey of UK practice
- 1 July 2005
- Published by Elsevier in International Journal of Obstetric Anesthesia
- Vol. 14 (3) , 219-222
Antenatal anaesthetic assessment of high-risk pregnancy: a survey of UK practice
- 13 December 2004
- Published by Wiley in Anaesthesia
- Vol. 60 (1) , 60-64
The Glidescope ® system: a clinical assessment of performance
Summary: The Glidescope ® is a new videolaryngoscope. It has a digital camera incorporated in the blade which displays a view of the vocal cords on a monitor. This allows the placement of a tracheal tube to be visualised. We describe its performance in 50 patients who required orotracheal intubation for elective surgery. Two investigators performed 25 intubations each. Intubation with the Glidescope ® was successful in 47 of the 50 cases. The three failures occurred early in the series and were attributed to the initial learning curve. The success rate after the first eight patients in each series was 100%. The median (IQR [range]) time to intubation was 40 (30–55 [15–105]) s. The Glidescope ® provided a grade I view of the glottis in 44 cases and a grade II view in six cases. The view of the larynx was improved in almost half (23) of the cases. The Glidescope ® improved the view by one grade in 22 and by two grades in one patient. We conclude that the Glidescope ® is an effective device for tracheal intubation and provides an improved view of the larynx. Further clinical studies are necessary to evaluate its role in airways that are difficult to manage.
- 13 December 2004
- Published by Wiley in Anaesthesia
- Vol. 60 (1) , 60-64
The Glidescope ® system: a clinical assessment of performance
Summary: The Glidescope ® is a new videolaryngoscope. It has a digital camera incorporated in the blade which displays a view of the vocal cords on a monitor. This allows the placement of a tracheal tube to be visualised. We describe its performance in 50 patients who required orotracheal intubation for elective surgery. Two investigators performed 25 intubations each. Intubation with the Glidescope ® was successful in 47 of the 50 cases. The three failures occurred early in the series and were attributed to the initial learning curve. The success rate after the first eight patients in each series was 100%. The median (IQR [range]) time to intubation was 40 (30–55 [15–105]) s. The Glidescope ® provided a grade I view of the glottis in 44 cases and a grade II view in six cases. The view of the larynx was improved in almost half (23) of the cases. The Glidescope ® improved the view by one grade in 22 and by two grades in one patient. We conclude that the Glidescope ® is an effective device for tracheal intubation and provides an improved view of the larynx. Further clinical studies are necessary to evaluate its role in airways that are difficult to manage.