MSMohamed Sheta

Mohamed Sheta

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Mohamed Sheta has a total of 9 co-authors. Here are the top co-authors by number of shared publications:

  • Suzan Gad

    Pediatrics and Neonatology Department, Suez Canal University Faculty of Medicine, Ismailia, Egypt

    2 shared publications
  • Abeer Alkhalafawi

    Department of Pediatrics, Ras Elkheima Hospital, Ras Elkheima, UAE

    1 shared publication
  • Abeer I Al-Khalafawi

    Neonatology Department, Saqr Hospital, MOH, Ras Alkheima, United Arab Emirates

    1 shared publication
  • Heba A Abu El-Fadl

    Pediatrics and Neonatology Department, Suez Canal University Faculty of Medicine, Ismailia, Egypt

    1 shared publication
  • Maha Anany

    Pediatrics and Neonatology Department, Suez Canal University Faculty of Medicine, Ismailia, Egypt

    1 shared publication
  • Mervat Hesham

    Department of Pediatrics, Faculty of Medicine, Zagazig University, Zagazig, Egypt

    1 shared publication

Latest Publications

  • Open Access

    Expressed Breast Milk Contamination in Neonatal Intensive Care Unit

    by Suzan Gad, Mohamed M Sheta, Abeer I Al-Khalafawi, Heba A Abu El-Fadl, Maha Anany, Shaimaa Sahmoud, Mona Karem Amin

    Background: The health benefits of breastfeeding are well known. However, some ill babies including those admitted to the neonatal intensive care unit (NICU) cannot be directly breastfed. In this situation, expressed breast milk (EBM) can be used. However, breast milk is not always sterile and may be contaminated by many microorganisms. EBM contamination is probably attributed to improper technical and hygienic factors and may pose significant threats to the newborn baby. The present study aimed to document the prevalence of EBM contamination in NICU and to uncover the relevant risk factors. Subjects and Methods: The study included 118 mothers who could express breast milk for their own neonates admitted to the NICU. A checklist was used to document the steps the mothers followed during expression of milk and all steps of handling until the EBM reached the NICU. A 1 mL sample of EBM was obtained and sent to the microbiology laboratory within 20 minutes. Data obtained from the present study are expressed as number and percentage or mean ± standard deviation (SD). Statistical calculations were computed using SPSS 25. Results: In the present study, 106 (89.8%) out of the assessed 118 EBM samples were contaminated. Hygienic factors related to EBM contamination included hand only wash, possible recontamination of hands during turning taps off, lack of using cotton pads or cloth piece on nipple and breast cleaning by water only. Other factors related to EBM contamination included container cleaning by water only, fresh milk refrigeration after > 4 hours, adding freshly expressed warm breast milk to refrigerated milk expressed earlier in the same day, milk transport in plastic bags with ice packs and longer transportation time. In the contaminated samples, the most commonly isolated organisms included Staphylococcus aureus (55.7%),Staphylococcus epidermidis (21.7%) and Enterobacter (11.6%). Conclusion: The present study identified bacterial contamination in about 90% of EBM samples delivered to NICU infants. Factors related to EBM contamination include hygienic, storage and transport factors.


  • Open Access

    Value of Neutrophil to Lymphocyte Ratio in Early Prediction of Meconium Aspiration Syndrome

    by Suzan Gad, Abeer Alkhalafawi, Syed Raza, Mervat Hesham, Mohamed Sheta

    Meconium aspiration syndrome (MAS) is a serious neonatal condition. Prediction of MAS is challenging particularly in low-resource setting. Neutrophil to lymphocyte ratio (NLR) is a new simple index used for diagnosis of many inflammatory conditions. The present study was an attempt to determine whether NLR can predict the occurrence of MAS. The present study included 101 children with meconium-stained amniotic fluid. They comprised 22 patients who developed MAS and 79 neonates who didn't have the condition. All neonates were subjected to careful analysis of maternal and perinatal history in addition to thorough clinical assessment and radiological and laboratory evaluation. Blood samples from the umbilical cord were collected at birth and were used to obtain complete blood counts and C-reactive protein (CRP) assay. Univariate analysis revealed that elevated CRP levels, increased NLR, and 5-minute Apgar score of <7 were significant risk factors for the occurrence of MAS. Multivariate analysis revealed that low 5-minute Apgar score and increased NLR remained as significant risk factors of MAS. Receiver operating characteristic curve analysis showed good performance of NLR in prediction of MAS. NLR is useful in prediction of MAS in term neonates with meconium-stained amniotic fluid.