Herbert Gross
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Herbert Gross has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
Ziyao Tang
Friedrich Schiller University Jena
4 shared publications- Norman Girma Worku
Institute of Applied Physics, Friedrich-Schiller-Universität, Albert-Einstein-Str. 15, 07745 Jena, Germany
3 shared publications - Xiang Lu
Friedrich-Schiller-University Jena, Institute of Applied Physics, Albert-Einstein-Strasse 15, Jena 07745, Germany
3 shared publications - Danyun Cai
Friedrich Schiller University Jena
2 shared publications Johannes Stock
2 shared publications- Stefan Nolte
Friedrich Schiller University Jena
2 shared publications
Latest Publications
- 28 March 2025
- Published by Optica Publishing Group in Optics Express
- Vol. 33 (7) , 15415-15422
Avoiding the tip: spiral optics for robust high power beam shaping of Bessel beams
Bessel Gaussian beams offer unique possibilities in material processing due to their elongated high-intensity line foci. They are usually created using an axicon. Being used with high power, the most critical part of the axicon is its tip, as it is prone to laser-induced damage. Any imperfection of the tip can be the source of aberrations of the focus. Therefore, we propose to apply Laguerre Gaussian beam shaping to circumvent the tip of the axicon altogether. We introduce an optical system consisting of spiral phase plates and an axicon to combine Laguerre and Bessel Gaussian beam shaping. This system is experimentally implemented using custom-made spiral phase plates and a large angle axicon. We characterize and finally apply the system to glass cutting and demonstrate the cleaving of a 2 mm thick glass sample, which results in a high-quality breaking edge with sub-micron roughness.
- 28 March 2025
- Published by Optica Publishing Group in Optics Express
- Vol. 33 (7) , 15415-15422
Avoiding the tip: spiral optics for robust high power beam shaping of Bessel beams
Bessel Gaussian beams offer unique possibilities in material processing due to their elongated high-intensity line foci. They are usually created using an axicon. Being used with high power, the most critical part of the axicon is its tip, as it is prone to laser-induced damage. Any imperfection of the tip can be the source of aberrations of the focus. Therefore, we propose to apply Laguerre Gaussian beam shaping to circumvent the tip of the axicon altogether. We introduce an optical system consisting of spiral phase plates and an axicon to combine Laguerre and Bessel Gaussian beam shaping. This system is experimentally implemented using custom-made spiral phase plates and a large angle axicon. We characterize and finally apply the system to glass cutting and demonstrate the cleaving of a 2 mm thick glass sample, which results in a high-quality breaking edge with sub-micron roughness.
- 7 November 2023
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 14 (12) , 6190-6205
Field curvature reduction in miniaturized high numerical aperture and large field-of-view objective lenses with sub 1 µm lateral resolution
In this paper the development of a miniaturized endoscopic objective lens for various biophotonics applications is presented. While limiting the mechanical dimensions to 2.2 mm diameter and 13 mm total length, a numerical aperture of 0.7 in water and a field-of-view (FOV) diameter of 282 µm are achieved. To enable multimodal usage a wavelength range of 488 nm to 632 nm was considered. The performed broad design study aimed for field curvature reduction when maintaining the sub 1 µm resolution over a large FOV. Moreover, the usage of GRadient-INdex (GRIN) lenses was investigated. The resolution, field curvature improvement and chromatic performance of the novel device were validated by means of a confocal laser-scanning-microscope.
- 7 November 2023
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 14 (12) , 6190-6205
Field curvature reduction in miniaturized high numerical aperture and large field-of-view objective lenses with sub 1 µm lateral resolution
In this paper the development of a miniaturized endoscopic objective lens for various biophotonics applications is presented. While limiting the mechanical dimensions to 2.2 mm diameter and 13 mm total length, a numerical aperture of 0.7 in water and a field-of-view (FOV) diameter of 282 µm are achieved. To enable multimodal usage a wavelength range of 488 nm to 632 nm was considered. The performed broad design study aimed for field curvature reduction when maintaining the sub 1 µm resolution over a large FOV. Moreover, the usage of GRadient-INdex (GRIN) lenses was investigated. The resolution, field curvature improvement and chromatic performance of the novel device were validated by means of a confocal laser-scanning-microscope.
- 25 October 2023
- Published by Optica Publishing Group in Applied Optics
- Vol. 62 (31) , 8390-8401
Reflective dual field-of-view optical system based on the Alvarez principle
A novel, to the best of our knowledge, dual-state reflective optical relay system based on the Alvarez system is proposed, which can be used for remote sensing applications. By keeping the image and pupil positions constant, it can be combined with a telescope to achieve two different magnifications. As a compact structure with only two moving parts, freeform optical mirrors and a nearly diffraction limited performance for the infrared wavelength 8 mu m make it an attractive subsystem for space applications. Different design tradeoffs and the preferred layout properties are discussed in detail.
- 25 October 2023
- Published by Optica Publishing Group in Applied Optics
- Vol. 62 (31) , 8390-8401
Reflective dual field-of-view optical system based on the Alvarez principle
A novel, to the best of our knowledge, dual-state reflective optical relay system based on the Alvarez system is proposed, which can be used for remote sensing applications. By keeping the image and pupil positions constant, it can be combined with a telescope to achieve two different magnifications. As a compact structure with only two moving parts, freeform optical mirrors and a nearly diffraction limited performance for the infrared wavelength 8 mu m make it an attractive subsystem for space applications. Different design tradeoffs and the preferred layout properties are discussed in detail.
- 2 December 2021
- Published by Optica Publishing Group in Optics Express
- Vol. 29 (25) , 42020-42036
Extended aberration analysis in symmetry-free optical systems – part II: evaluation and application
In part I [ Opt. Express 29, 39967 (2021)10.1364/OE.439862 ] of this publication, the working principle of a mixed ray-tracing (MRT) method is introduced for surface-decomposed transverse aberration contributions, and the settings and various calculation options are discussed. Following part I, this paper is a supplement with the evaluation of the calculation results and more illustrations of practical applications, which focuses on the support of the MRT method during the symmetry-free optical system design process. The comprehensive analysis of a group of lithography systems as an application example proves that the MRT method is a powerful tool for imaging system performance assessment, as well as for relative sensitivity analysis among the surfaces in the optical system.
- 2 December 2021
- Published by Optica Publishing Group in Optics Express
- Vol. 29 (25) , 42020-42036
Extended aberration analysis in symmetry-free optical systems – part II: evaluation and application
In part I [ Opt. Express 29, 39967 (2021)10.1364/OE.439862 ] of this publication, the working principle of a mixed ray-tracing (MRT) method is introduced for surface-decomposed transverse aberration contributions, and the settings and various calculation options are discussed. Following part I, this paper is a supplement with the evaluation of the calculation results and more illustrations of practical applications, which focuses on the support of the MRT method during the symmetry-free optical system design process. The comprehensive analysis of a group of lithography systems as an application example proves that the MRT method is a powerful tool for imaging system performance assessment, as well as for relative sensitivity analysis among the surfaces in the optical system.
- 16 November 2021
- Published by Optica Publishing Group in Optics Express
- Vol. 29 (24) , 39967-39982
Extended aberration analysis in symmetry-free optical systems – part I: method of calculation
The imaging performance evaluation of symmetry-free optical systems is of great importance during the correction process of optical design. However, due to the complexity and limitations of the available tools, the higher-order aberrations in the system cannot be well analyzed and are hard to control. In this paper, the theoretical background and the mathematical approach of a quantitative analysis method for surface-decomposed transverse aberration in the symmetry-free systems are introduced. With the mixed ray-tracing calculation in both real and paraxial cases, the implementations of full-order intrinsic/induced aberration, as well as the surface-additive Zernike coefficient fitting method are demonstrated. The applications of this method help assess the correction performance considering the relatively critical surfaces in an arbitrary off-axis system. The reliability and the accuracy of the method will be evaluated in part II with a test system. And as an illustration of the practical usage of the method for optical design, the corresponding applications on a group of lithographic systems will also be demonstrated.
- 16 November 2021
- Published by Optica Publishing Group in Optics Express
- Vol. 29 (24) , 39967-39982
Extended aberration analysis in symmetry-free optical systems – part I: method of calculation
The imaging performance evaluation of symmetry-free optical systems is of great importance during the correction process of optical design. However, due to the complexity and limitations of the available tools, the higher-order aberrations in the system cannot be well analyzed and are hard to control. In this paper, the theoretical background and the mathematical approach of a quantitative analysis method for surface-decomposed transverse aberration in the symmetry-free systems are introduced. With the mixed ray-tracing calculation in both real and paraxial cases, the implementations of full-order intrinsic/induced aberration, as well as the surface-additive Zernike coefficient fitting method are demonstrated. The applications of this method help assess the correction performance considering the relatively critical surfaces in an arbitrary off-axis system. The reliability and the accuracy of the method will be evaluated in part II with a test system. And as an illustration of the practical usage of the method for optical design, the corresponding applications on a group of lithographic systems will also be demonstrated.
- 20 July 2021
- Published by Optica Publishing Group in Applied Optics
- Vol. 60 (21) , 6313-6321
Generalized chromatic aberrations in non-rotationally symmetric optical systems–Part I: mathematical approach
In non-rotationally symmetric optical systems, chromatic aberrations must be defined in a generalized way with reference to the optical axis ray and optimal tilted parabasal image plane of the central wavelength. In this paper, the definition of generalized chromatic aberrations is clarified. The mathematical calculation in optical systems with arbitrary symmetry and surface shape is realized by ray- and wavefront-based methods, respectively, that are originally identical. The additivity of wavefront after each surface ensures the surface decomposition of chromatic aberrations. In the end, the influence of pupil aberration, which is of a higher order, is discussed. The consistency of our methods with Seidel aberrations in the lowest aberration order of the rotationally symmetric system and the application of our methods in diverse non-rotationally symmetric refractive systems will be addressed in detail in Part II.
- 20 July 2021
- Published by Optica Publishing Group in Applied Optics
- Vol. 60 (21) , 6313-6321
Generalized chromatic aberrations in non-rotationally symmetric optical systems–Part I: mathematical approach
In non-rotationally symmetric optical systems, chromatic aberrations must be defined in a generalized way with reference to the optical axis ray and optimal tilted parabasal image plane of the central wavelength. In this paper, the definition of generalized chromatic aberrations is clarified. The mathematical calculation in optical systems with arbitrary symmetry and surface shape is realized by ray- and wavefront-based methods, respectively, that are originally identical. The additivity of wavefront after each surface ensures the surface decomposition of chromatic aberrations. In the end, the influence of pupil aberration, which is of a higher order, is discussed. The consistency of our methods with Seidel aberrations in the lowest aberration order of the rotationally symmetric system and the application of our methods in diverse non-rotationally symmetric refractive systems will be addressed in detail in Part II.
- 20 July 2021
- Published by Optica Publishing Group in Applied Optics
- Vol. 60 (21) , 6322-6330
Generalized chromatic aberrations in non-rotationally symmetric optical systems–Part II: applications
In this paper, as a supplement to Part I, three examples will be provided to verify our methods. In the first example of a double Gauss system, the chromatic aberrations calculated by our methods and those given by the Seidel aberrations are compared. Then we will present two examples analyzing the generalized chromatic aberrations in refractive system with freeform surfaces by our methods. The stereomicroscope is utilized to demonstrate the feasibility and consistency of both ray- and wavefront-based methods. The anamorphic imaging objective lens proves that it is necessary to consider the pupil aberration when it cannot be neglected. In both examples, the surface decomposed a full-field display of the chromatic aberrations shows us that it is a convenient and powerful tool to analyze the generalized chromatic aberrations in nonrotationally symmetric refractive optical systems.
- 20 July 2021
- Published by Optica Publishing Group in Applied Optics
- Vol. 60 (21) , 6322-6330
Generalized chromatic aberrations in non-rotationally symmetric optical systems–Part II: applications
In this paper, as a supplement to Part I, three examples will be provided to verify our methods. In the first example of a double Gauss system, the chromatic aberrations calculated by our methods and those given by the Seidel aberrations are compared. Then we will present two examples analyzing the generalized chromatic aberrations in refractive system with freeform surfaces by our methods. The stereomicroscope is utilized to demonstrate the feasibility and consistency of both ray- and wavefront-based methods. The anamorphic imaging objective lens proves that it is necessary to consider the pupil aberration when it cannot be neglected. In both examples, the surface decomposed a full-field display of the chromatic aberrations shows us that it is a convenient and powerful tool to analyze the generalized chromatic aberrations in nonrotationally symmetric refractive optical systems.
- 29 April 2021
- Published by Optica Publishing Group in Applied Optics
- Vol. 60 (13) , 3954-3963
Flexible, fast, and benchmarked vectorial model for focused laser beams
In-bulk processing of materials by laser radiation has largely evolved over the last decades and still opens up new scientific and industrial potentials. The development of any in-bulk processing application relies on the knowledge of laser propagation and especially the volumetric field distribution near the focus. Many commercial programs can simulate this, but, to adapt them, or to develop new methods, one usually must create a specific software. Besides, most of the time people also need to measure the actual field distribution near the focus to evaluate their assumptions in the simulation. To easily get access to this knowledge, we present our high-precision field distribution measuring method and release our in-house software InFocus [https://github.com/QF06/InFocus], under the Creative Commons 4.0 license. Our measurements provide 300 nm longitudinal resolution and diffraction limited lateral resolution. The in-house software allows fast vectorial analysis of the focused volumetric field distribution in bulk. Simulations of the linear propagation of light under different conditions (focusing optics, wavelength, spatial shape, and propagation medium) are in excellent agreement with propagation imaging experiments. The aberrations provoked by the refractive index mismatch as well as those induced by the focusing optics are both taken into account. The results indicate that our proposed model is suitable for the precise evaluation of energy deposition.
- 29 April 2021
- Published by Optica Publishing Group in Applied Optics
- Vol. 60 (13) , 3954-3963
Flexible, fast, and benchmarked vectorial model for focused laser beams
In-bulk processing of materials by laser radiation has largely evolved over the last decades and still opens up new scientific and industrial potentials. The development of any in-bulk processing application relies on the knowledge of laser propagation and especially the volumetric field distribution near the focus. Many commercial programs can simulate this, but, to adapt them, or to develop new methods, one usually must create a specific software. Besides, most of the time people also need to measure the actual field distribution near the focus to evaluate their assumptions in the simulation. To easily get access to this knowledge, we present our high-precision field distribution measuring method and release our in-house software InFocus [https://github.com/QF06/InFocus], under the Creative Commons 4.0 license. Our measurements provide 300 nm longitudinal resolution and diffraction limited lateral resolution. The in-house software allows fast vectorial analysis of the focused volumetric field distribution in bulk. Simulations of the linear propagation of light under different conditions (focusing optics, wavelength, spatial shape, and propagation medium) are in excellent agreement with propagation imaging experiments. The aberrations provoked by the refractive index mismatch as well as those induced by the focusing optics are both taken into account. The results indicate that our proposed model is suitable for the precise evaluation of energy deposition.
- Open Access
- 29 April 2021
- Published by Optica Publishing Group in Optics Express
- Vol. 29 (10) , 14985-15000
Wigner function-based modeling and propagation of partially coherent light in optical systems with scattering surfaces
Light scattering from residual manufacturing errors of optical surfaces has a large impact on the image quality of optical systems. Classical ray-based methods to simulate surface scattering in optical systems depend on statistical models of surface errors and neglect the wave properties of light, which prohibit the integration of statistical surface error models with beam propagation methods. Additionally, the impact of multiple scattering from different frequency components of surface errors cannot be easily modelled by existing methods. Here we analyze the impact of different frequency components of surface errors induced by diamond-turned surface grinding on image quality, and we propose a Wigner function-based approach in which light is modelled as partially coherent. In this unified model, by selecting the proper definition of light coherence, we can combine the statistical and deterministic models of surface errors, enabling efficient, simultaneous simulation of multiple scattering from high- and mid-spatial frequency (HSF and MSF, respectively) surface errors, as well as the interference and edge diffraction of light.
- 29 April 2021
- Published by Optica Publishing Group in Optics Express
- Vol. 29 (10) , 14985-15000
Open AccessWigner function-based modeling and propagation of partially coherent light in optical systems with scattering surfaces
Light scattering from residual manufacturing errors of optical surfaces has a large impact on the image quality of optical systems. Classical ray-based methods to simulate surface scattering in optical systems depend on statistical models of surface errors and neglect the wave properties of light, which prohibit the integration of statistical surface error models with beam propagation methods. Additionally, the impact of multiple scattering from different frequency components of surface errors cannot be easily modelled by existing methods. Here we analyze the impact of different frequency components of surface errors induced by diamond-turned surface grinding on image quality, and we propose a Wigner function-based approach in which light is modelled as partially coherent. In this unified model, by selecting the proper definition of light coherence, we can combine the statistical and deterministic models of surface errors, enabling efficient, simultaneous simulation of multiple scattering from high- and mid-spatial frequency (HSF and MSF, respectively) surface errors, as well as the interference and edge diffraction of light.
- 6 January 2021
- Published by Optica Publishing Group in Applied Optics
- Vol. 60 (2) , 333-341
Improved correction by freeform surfaces in prism spectrometer concepts
The correction of spatial resolution and distortion in imaging spectrometer systems is of great importance due to their significant impact on efficiency and quality. In this study, we analyze the corrective power of freeforms added at different positions in various spectrometer systems for high-performance requirements. The results show that the combination of a freeform prism and a second freeform close to the image has the best correction of distortion while preserving spot size.
- 6 January 2021
- Published by Optica Publishing Group in Applied Optics
- Vol. 60 (2) , 333-341
Improved correction by freeform surfaces in prism spectrometer concepts
The correction of spatial resolution and distortion in imaging spectrometer systems is of great importance due to their significant impact on efficiency and quality. In this study, we analyze the corrective power of freeforms added at different positions in various spectrometer systems for high-performance requirements. The results show that the combination of a freeform prism and a second freeform close to the image has the best correction of distortion while preserving spot size.