Noriyuki Tabuchi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Noriyuki Tabuchi has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
Makoto Sunamori
3 shared publicationsAya Shibamiya
Graduate School of Allied Health Sciences, Tokyo Medical and Dental University, Tokyo, Japan; and
2 shared publicationsTakatoshi Koyama
Graduate School of Allied Health Sciences, Tokyo Medical and Dental University, Tokyo, Japan; and
2 shared publicationsHideki Nakahara
1 shared publicationHirokuni Arai
1 shared publicationHiroyuki Tanaka
1 shared publication
Latest Publications
- 31 May 2009
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 87 (5) , 1425
Invited Commentary
- 31 May 2009
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 87 (5) , 1425
Invited Commentary
- 1 January 2004
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 77 (1) , 342-343
Double-patch technique for postinfarction ventricular septal perforation
- 1 January 2004
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 77 (1) , 342-343
Double-patch technique for postinfarction ventricular septal perforation
- 21 May 2003
- Published by Wiley in Artificial Organs
- Vol. 27 (6) , 591-594
Activated Leukocytes Adsorbed on the Surface of an Extracorporeal Circuit
Biocompatibility of extracorporeal circuits has mostly been investigated by sampling blood in circulation. However, a proportion of activated leukocytes leave circulation by sticking to the circuits, and might affect the circuit biocompatibility. To reveal these characteristics, we eluted the adsorbed leukocytes from circuits used for 6 patients by washing with ethylenediaminetetraacetic acid (EDTA)‐HEPES buffer. 1.3 × 109 leukocytes, representing 5 to 10% of the circulating leukocytes, were collected. Most were neutrophils expressing CD11b antigens as high as those in circulation during cardiopulmonary bypass. Adsorbed monocytes expressed tissue factor higher than those in circulation (P < 0.05). An elution procedure by EDTA itself induced only a minimal activation of the leukocytes. These results indicate that extracorporeal circuits adsorb a large number of activated neutrophils and a small number of highly thrombogenic monocytes during their use. Although our data is limited, this elution procedure appears useful to investigate the biocompatibility of extracorporeal circuits.
- 21 May 2003
- Published by Wiley in Artificial Organs
- Vol. 27 (6) , 591-594
Activated Leukocytes Adsorbed on the Surface of an Extracorporeal Circuit
Biocompatibility of extracorporeal circuits has mostly been investigated by sampling blood in circulation. However, a proportion of activated leukocytes leave circulation by sticking to the circuits, and might affect the circuit biocompatibility. To reveal these characteristics, we eluted the adsorbed leukocytes from circuits used for 6 patients by washing with ethylenediaminetetraacetic acid (EDTA)‐HEPES buffer. 1.3 × 109 leukocytes, representing 5 to 10% of the circulating leukocytes, were collected. Most were neutrophils expressing CD11b antigens as high as those in circulation during cardiopulmonary bypass. Adsorbed monocytes expressed tissue factor higher than those in circulation (P < 0.05). An elution procedure by EDTA itself induced only a minimal activation of the leukocytes. These results indicate that extracorporeal circuits adsorb a large number of activated neutrophils and a small number of highly thrombogenic monocytes during their use. Although our data is limited, this elution procedure appears useful to investigate the biocompatibility of extracorporeal circuits.
- 1 June 2001
- Published by Georg Thieme Verlag KG in The Thoracic and Cardiovascular Surgeon
- Vol. 49 (3) , 189-190
Scope-Guided Implantation of a Stented Elephant Trunk in Acute Aortic Dissection
A reliable guide is essential for implanting a stented graft safely into a recently dissected, fragile aorta. In 4 patients with acute aortic dissection, the implantation of a stented elephant trunk was done safely using an endoscope for direct visualization. In all patients, the operation went well. The placement of a stent appears to enhance the benefit of the elephant trunk, which itself reduces the complications of an arch replacement in acute dissection.
- 1 June 2001
- Published by Georg Thieme Verlag KG in The Thoracic and Cardiovascular Surgeon
- Vol. 49 (3) , 189-190
Scope-Guided Implantation of a Stented Elephant Trunk in Acute Aortic Dissection
A reliable guide is essential for implanting a stented graft safely into a recently dissected, fragile aorta. In 4 patients with acute aortic dissection, the implantation of a stented elephant trunk was done safely using an endoscope for direct visualization. In all patients, the operation went well. The placement of a stent appears to enhance the benefit of the elephant trunk, which itself reduces the complications of an arch replacement in acute dissection.
- 1 May 2001
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 71 (5) , 1749-1750
Remaining procoagulant property of wound blood washed by a cell-saving device
- 1 May 2001
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 71 (5) , 1749-1750
Remaining procoagulant property of wound blood washed by a cell-saving device