Ferdinand Kiemeneij
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ferdinand Kiemeneij has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
GertJan Laarman
Onze Lieve Vrouwe Gasthuis (OLVG), Amsterdam, Netherlands
4 shared publicationsTon Slagboom
Onze Lieve Vrouwe Gasthuis (OLVG), Amsterdam, Netherlands
4 shared publicationsRon van der Wieken
Amsterdam Department of Interventional Cardiology, Onze Lieve Vrouwe Gasthuis, Amsterdam, The Netherlands
3 shared publicationsBhavesh U. Vajifdar
Amsterdam Department of Interventional Cardiology, Onze Lieve Vrouwe Gasthuis, Amsterdam, The Netherlands
2 shared publicationsSimon C. Eccleshall
Amsterdam Department of Interventional Cardiology, Onze Lieve Vrouwe Gasthuis, Amsterdam, The Netherlands
2 shared publicationsDouglas Fraser
Amsterdam Department of Interventional Cardiology, Onze Lieve Vrouwe Gasthuis, Amsterdam, The Netherlands
1 shared publication
Latest Publications
- 1 May 2009
- Published by Elsevier in Revista Española de Cardiología (English Edition)
- Vol. 62 (5) , 471-473
Left Radial Approach in Cardiac Catheterization. Does it Really Matter?
- 1 May 2009
- Published by Elsevier in Revista Española de Cardiología (English Edition)
- Vol. 62 (5) , 471-473
Left Radial Approach in Cardiac Catheterization. Does it Really Matter?
- 28 February 2008
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 71 (4) , 510-516
Use of the Stereotaxis Niobe® magnetic navigation system for percutaneous coronary intervention: Results from 350 consecutive patients
Introduction: The Stereotaxis Niobe® magnetic navigation system (MNS; Stereotaxis, St. Louis, MO) facilitates precise vector based navigation of magnetically‐enabled guidewires for percutaneous coronary intervention (PCI) by using two permanent magnets located on opposite sides of the patient table to produce a controllable magnetic field. The objective of this study is to describe the results of a large patient series using this system, to compare the results with a historical control group, and to detail the MNS learning curve. Methods: We prospectively collected data on 439 lesions in 350 consecutive PCI patients using the MNS predominantly using the radial approach. All data were entered into a customized database to capture the key parameters and then compared with a previously collected stent registry from the same center. Results: In 410/439 lesions (93%) the wire crossed the lesion successfully using the MNS. Twenty‐five of the 35 failures were chronic total occlusions. No wire perforations or dissections occurred in this population. Lesion crossing time was 81 ± 168 sec (mean ± SD), and fluoroscopy time was 64 ± 123 sec. A clear learning curve was evident after the first 80 patients. Contrast use was reduced when compared with a historical control group. Procedural and fluoroscopy times were similar. Conclusions: Use of the MNS may enable the successful performance of more complex procedures in the cardiac catheterization laboratory with an improvement in time efficiency.
- 28 February 2008
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 71 (4) , 510-516
Use of the Stereotaxis Niobe® magnetic navigation system for percutaneous coronary intervention: Results from 350 consecutive patients
Introduction: The Stereotaxis Niobe® magnetic navigation system (MNS; Stereotaxis, St. Louis, MO) facilitates precise vector based navigation of magnetically‐enabled guidewires for percutaneous coronary intervention (PCI) by using two permanent magnets located on opposite sides of the patient table to produce a controllable magnetic field. The objective of this study is to describe the results of a large patient series using this system, to compare the results with a historical control group, and to detail the MNS learning curve. Methods: We prospectively collected data on 439 lesions in 350 consecutive PCI patients using the MNS predominantly using the radial approach. All data were entered into a customized database to capture the key parameters and then compared with a previously collected stent registry from the same center. Results: In 410/439 lesions (93%) the wire crossed the lesion successfully using the MNS. Twenty‐five of the 35 failures were chronic total occlusions. No wire perforations or dissections occurred in this population. Lesion crossing time was 81 ± 168 sec (mean ± SD), and fluoroscopy time was 64 ± 123 sec. A clear learning curve was evident after the first 80 patients. Contrast use was reduced when compared with a historical control group. Procedural and fluoroscopy times were similar. Conclusions: Use of the MNS may enable the successful performance of more complex procedures in the cardiac catheterization laboratory with an improvement in time efficiency.
- 1 August 2007
- Vol. 19 (8) , 354
Cost-effectiveness of transradial coronary access.
- 20 May 2003
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 59 (2) , 161-164
Hydrophilic coating aids radial sheath withdrawal and reduces patient discomfort following transradial coronary intervention: A randomized double‐blind comparison of coated and uncoated sheaths
Radial artery spasm may cause severe discomfort during radial artery sheath removal. A hydrophilic‐coated sheath may reduce the force required to remove a radial sheath. This force may be quantified using an automatic pullback device (APD). The objective of this study was to assess if a hydrophilic coating reduces the required force and discomfort associated with removal of a radial sheath following transradial coronary intervention. Ninety patients undergoing percutaneous coronary intervention via the radial artery were randomly assigned to two groups receiving either coated or uncoated introducer sheaths. Radifocus Introducer II (Terumo) 25 cm, 6 Fr radial sheaths and sheaths that were identical apart from the presence of the coating were used in all patients. The APD was used for sheath removal at the end of the procedure. Three patients (7%) in the coated group experienced discomfort during automatic sheath removal, compared to 12 patients (27%) in the uncoated group (P = 0.02). The maximum pullback force (MPF) was significantly lower in the coated compared to the uncoated group (0.24 ± 0.31 vs. 0.44 ± 0.33 kg; P = 0.003). Similarly, the mean pullback force was significantly lower in the coated group (0.14 ± 0.23 vs. 0.32 ± 0.24 kg; P < 0.001). Only one patient (2%) in each group had an MPF greater than 1.0 kg together with clinical evidence of radial artery spasm. Removal of the coated Terumo Radifocus sheath requires less force than an identical uncoated sheath. The coated sheath was also associated with less discomfort for the patient. Cathet Cardiovasc Intervent 2003;59:161–164.
- 20 May 2003
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 59 (2) , 161-164
Hydrophilic coating aids radial sheath withdrawal and reduces patient discomfort following transradial coronary intervention: A randomized double‐blind comparison of coated and uncoated sheaths
Radial artery spasm may cause severe discomfort during radial artery sheath removal. A hydrophilic‐coated sheath may reduce the force required to remove a radial sheath. This force may be quantified using an automatic pullback device (APD). The objective of this study was to assess if a hydrophilic coating reduces the required force and discomfort associated with removal of a radial sheath following transradial coronary intervention. Ninety patients undergoing percutaneous coronary intervention via the radial artery were randomly assigned to two groups receiving either coated or uncoated introducer sheaths. Radifocus Introducer II (Terumo) 25 cm, 6 Fr radial sheaths and sheaths that were identical apart from the presence of the coating were used in all patients. The APD was used for sheath removal at the end of the procedure. Three patients (7%) in the coated group experienced discomfort during automatic sheath removal, compared to 12 patients (27%) in the uncoated group (P = 0.02). The maximum pullback force (MPF) was significantly lower in the coated compared to the uncoated group (0.24 ± 0.31 vs. 0.44 ± 0.33 kg; P = 0.003). Similarly, the mean pullback force was significantly lower in the coated group (0.14 ± 0.23 vs. 0.32 ± 0.24 kg; P < 0.001). Only one patient (2%) in each group had an MPF greater than 1.0 kg together with clinical evidence of radial artery spasm. Removal of the coated Terumo Radifocus sheath requires less force than an identical uncoated sheath. The coated sheath was also associated with less discomfort for the patient. Cathet Cardiovasc Intervent 2003;59:161–164.
- 19 February 2003
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 58 (3) , 281-284
Evaluation of a spasmolytic cocktail to prevent radial artery spasm during coronary procedures
Radial artery spasm is a frequent complication of the transradial approach for coronary angiography and angioplasty. Recently, we have been able to quantify spasm using the automatic pullback device. The objective of this study was to assess the efficacy of an intra‐arterial vasodilating cocktail in reducing the incidence and severity of radial artery spasm. A hundred patients undergoing coronary procedures via the radial artery were divided into two groups of 50 each. Patients in group A received intra‐arterial cocktail (5 mg of verapamil plus 200 μg nitroglycerine in 10 ml of normal saline), while patients in group B did not receive any vasodilating drug. The pullback device was used for sheath removal at the end of the procedure. Seven (14%) patients in group A experienced pain (i.e., pain score of III–V) during automatic sheath removal, as compared to 17 (34%) in group B (P = 0.019). The mean pain score was significantly lower in group A than in group B (1.7 ± 0.94 vs. 2.08 ± 1.07; P = 0.03). The maximal pullback force (MPF) was also significantly lower for group A (0.53 ± 0.52 kg; range, 0.10–3.03 kg) as compared to group B (0.76 ± 0.45 kg; range, 0.24–1.99 kg; P = 0.013). Only 4 (8%) patients in group A had an MPF value greater than 1.0 kg, suggesting the presence of significant radial artery spasm, as opposed to 11 (22%) in group B (P = 0.029). Administration of an intra‐arterial vasodilating cocktail prior to sheath insertion reduces the occurrence and severity of radial artery spasm. Cathet Cardiovasc Intervent 2003;58:281–284.
- 19 February 2003
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 58 (3) , 281-284
Evaluation of a spasmolytic cocktail to prevent radial artery spasm during coronary procedures
Radial artery spasm is a frequent complication of the transradial approach for coronary angiography and angioplasty. Recently, we have been able to quantify spasm using the automatic pullback device. The objective of this study was to assess the efficacy of an intra‐arterial vasodilating cocktail in reducing the incidence and severity of radial artery spasm. A hundred patients undergoing coronary procedures via the radial artery were divided into two groups of 50 each. Patients in group A received intra‐arterial cocktail (5 mg of verapamil plus 200 μg nitroglycerine in 10 ml of normal saline), while patients in group B did not receive any vasodilating drug. The pullback device was used for sheath removal at the end of the procedure. Seven (14%) patients in group A experienced pain (i.e., pain score of III–V) during automatic sheath removal, as compared to 17 (34%) in group B (P = 0.019). The mean pain score was significantly lower in group A than in group B (1.7 ± 0.94 vs. 2.08 ± 1.07; P = 0.03). The maximal pullback force (MPF) was also significantly lower for group A (0.53 ± 0.52 kg; range, 0.10–3.03 kg) as compared to group B (0.76 ± 0.45 kg; range, 0.24–1.99 kg; P = 0.013). Only 4 (8%) patients in group A had an MPF value greater than 1.0 kg, suggesting the presence of significant radial artery spasm, as opposed to 11 (22%) in group B (P = 0.029). Administration of an intra‐arterial vasodilating cocktail prior to sheath insertion reduces the occurrence and severity of radial artery spasm. Cathet Cardiovasc Intervent 2003;58:281–284.
- 19 November 2001
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 54 (4) , 437-441
Measurement of radial artery spasm using an automatic pullback device
Current evaluation of radial artery spasm (RAS), a frequent finding during the transradial approach for coronary angiography and angioplasty (TRA), is subjective. A quantitative measure of RAS will help in evaluation and comparison of management strategies. The objectives of the study were to assess the feasibility and safety of using an automatic pullback device (APD) for removal of transradial introducer sheaths and to establish a parameter to quantify RAS. In 50 consecutive transradial procedures, the APD was used to measure the force required for sheath removal. The mean maximal pullback force (MPF) was 0.53 ± 0.52 kg (range, 0.1–3.0 kg). In 48 (96%) cases, the MPF was reached within the first 5 sec of pullback. All patients with clinical RAS (n = 4) had an MPF greater than 1.0 kg, while the remaining had an MPF less than 1.0 kg. All patients with severe pain during sheath removal (n = 3) had an MPF greater than 1.0 kg, while no patient with an MPF less than 1.0 kg had severe pain. It is feasible and safe to remove transradial introducer sheaths using the APD. The MPF is achieved within the first 5 sec of pullback and is a reliable parameter to quantify RAS. An MPF more than 1.0 kg correlates with clinical RAS and is associated with severe pain during sheath removal. Cathet Cardiovasc Intervent 2001;54:437–441.
- 19 November 2001
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 54 (4) , 437-441
Measurement of radial artery spasm using an automatic pullback device
Current evaluation of radial artery spasm (RAS), a frequent finding during the transradial approach for coronary angiography and angioplasty (TRA), is subjective. A quantitative measure of RAS will help in evaluation and comparison of management strategies. The objectives of the study were to assess the feasibility and safety of using an automatic pullback device (APD) for removal of transradial introducer sheaths and to establish a parameter to quantify RAS. In 50 consecutive transradial procedures, the APD was used to measure the force required for sheath removal. The mean maximal pullback force (MPF) was 0.53 ± 0.52 kg (range, 0.1–3.0 kg). In 48 (96%) cases, the MPF was reached within the first 5 sec of pullback. All patients with clinical RAS (n = 4) had an MPF greater than 1.0 kg, while the remaining had an MPF less than 1.0 kg. All patients with severe pain during sheath removal (n = 3) had an MPF greater than 1.0 kg, while no patient with an MPF less than 1.0 kg had severe pain. It is feasible and safe to remove transradial introducer sheaths using the APD. The MPF is achieved within the first 5 sec of pullback and is a reliable parameter to quantify RAS. An MPF more than 1.0 kg correlates with clinical RAS and is associated with severe pain during sheath removal. Cathet Cardiovasc Intervent 2001;54:437–441.