Bushra Obeidat
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Bushra Obeidat has a total of 55 co-authors. Here are the top co-authors by number of shared publications:
- Abdulkarem Amhamed
Qatar Environment and Energy Institute (QEERI), Doha, Qatar
4 shared publications - Odi Fawwaz Alrebei
Qatar Environment and Energy Research Institute (QEERI), Hamad Bin Khalifa University, Doha 34110, Qatar
3 shared publications Amal Abed
Department of Architecture, College of Architecture and Design, Jordan University of Science and Technology, Irbid, Jordan
2 shared publications- Anwar Hamdan Al Assaf
Department of Aviation Sciences, Amman Arab University, Amman 11953, Jordan
2 shared publications - Laurent M. Le Page
Oxford Thermofluids Institute, Oxford University, Oxford OX2 OES, UK
2 shared publications - Mai Hathal Al-Zuriqat
Department of Architecture, College of Architecture and Design, Jordan University of Science and Technology, 3030, Irbid 22110, Jordan
2 shared publications
Latest Publications
- 16 October 2026
- Published by Springer Nature in Acta Geophysica
- Vol. 74 (6) , 325
Surface thermal dynamics and air quality stressors in a rapidly urbanising semi-arid city: a multi-sensor satellite assessment of Greater Irbid, Jordan (2000–2025)
- 16 October 2026
- Published by Springer Nature in Acta Geophysica
- Vol. 74 (6) , 325
Surface thermal dynamics and air quality stressors in a rapidly urbanising semi-arid city: a multi-sensor satellite assessment of Greater Irbid, Jordan (2000–2025)
- Open Access
- 1 October 2026
- Published by Elsevier in Social Sciences & Humanities Open
- Vol. 14
Sleep quality, insomnia severity, and perceived cognitive difficulties among architecture students in studio-based education: A cross-sectional study in Jordan
- 1 October 2026
- Published by Elsevier in Social Sciences & Humanities Open
- Vol. 14
Open AccessSleep quality, insomnia severity, and perceived cognitive difficulties among architecture students in studio-based education: A cross-sectional study in Jordan
- Open Access
- 1 October 2026
- Published by WNGB Scientific Publishing House Sp. z o.o. in Journal of Ecological Engineering
- Vol. 27 (10) , 327-337
Computational fluid dynamics based assessment of passive vertical ventilation shaft configurations for improving indoor air quality in multi-story residential buildings
Shared vertical ventilation shafts are commonly used to ventilate bathrooms in multi-story residential buildings, yet weak pressure gradients and unseparated airflow paths can reduce exhaust effectiveness and allow air exchange between connected bathrooms. This study used computational fluid...
- 1 October 2026
- Published by WNGB Scientific Publishing House Sp. z o.o. in Journal of Ecological Engineering
- Vol. 27 (10) , 327-337
Open AccessComputational fluid dynamics based assessment of passive vertical ventilation shaft configurations for improving indoor air quality in multi-story residential buildings
Shared vertical ventilation shafts are commonly used to ventilate bathrooms in multi-story residential buildings, yet weak pressure gradients and unseparated airflow paths can reduce exhaust effectiveness and allow air exchange between connected bathrooms. This study used computational fluid...
- Open Access
- 12 September 2026
- Published by MDPI AG in Architecture
- Vol. 6 (3) , 162
Annual Daylight Performance, Glare, and Privacy-Curtain Trade-Offs in Single and Shared Oncology Patient Rooms: A Climate-Based Simulation Study
Daylight is a key component of evidence-based healthcare design, yet strategies that increase daylight may also introduce glare and interact with privacy measures used in shared hospital rooms. This study evaluated annual daylight performance in representative oncology patient rooms at King Abdullah University Hospital, Jordan, using climate-based simulation in Rhino-Grasshopper with Ladybug Tools/Honeybee and Radiance. Single-bed, two-bed shared, and four-bed shared rooms were compared across facade orientations. Annual illuminance, Daylight Glare Probability (DGP), high-dynamic-range visualizations, and patient-bed conditions were assessed, and the shared rooms were additionally simulated with and without fully deployed low-transmittance privacy curtains. South-facing shared rooms achieved the highest annual mean illuminance, whereas north-facing rooms generally produced lower and more spatially uniform daylight. Higher daylight availability was accompanied by greater glare occurrence at beds close to the facade. Under the modeled curtain scenario, annual mean illuminance at patient-head locations decreased by 77.7–99.7%, with the largest reductions at deeper beds. The findings show that daylight performance is governed by the interaction of room geometry, facade orientation, bed location, and privacy interventions. Annual room- and bed-level evaluation can therefore support oncology patient-room design that balances daylight availability, visual comfort, and visual privacy.
- 12 September 2026
- Published by MDPI AG in Architecture
- Vol. 6 (3) , 162
Open AccessAnnual Daylight Performance, Glare, and Privacy-Curtain Trade-Offs in Single and Shared Oncology Patient Rooms: A Climate-Based Simulation Study
Daylight is a key component of evidence-based healthcare design, yet strategies that increase daylight may also introduce glare and interact with privacy measures used in shared hospital rooms. This study evaluated annual daylight performance in representative oncology patient rooms at King Abdullah University Hospital, Jordan, using climate-based simulation in Rhino-Grasshopper with Ladybug Tools/Honeybee and Radiance. Single-bed, two-bed shared, and four-bed shared rooms were compared across facade orientations. Annual illuminance, Daylight Glare Probability (DGP), high-dynamic-range visualizations, and patient-bed conditions were assessed, and the shared rooms were additionally simulated with and without fully deployed low-transmittance privacy curtains. South-facing shared rooms achieved the highest annual mean illuminance, whereas north-facing rooms generally produced lower and more spatially uniform daylight. Higher daylight availability was accompanied by greater glare occurrence at beds close to the facade. Under the modeled curtain scenario, annual mean illuminance at patient-head locations decreased by 77.7–99.7%, with the largest reductions at deeper beds. The findings show that daylight performance is governed by the interaction of room geometry, facade orientation, bed location, and privacy interventions. Annual room- and bed-level evaluation can therefore support oncology patient-room design that balances daylight availability, visual comfort, and visual privacy.
- 20 February 2026
- Published by Springer Nature in Journal of Urban Health
Dwelling Form and Heat-Related Well-Being in a Semi-Arid City: A Cross-Sectional Survey of Apartment and Detached-House Residents in Irbid, Jordan
Rising heat-wave frequency and strong urban-heat-island (UHI) effects threaten thermal comfort and health in Jordan's fast-growing cities. While engineering studies suggest that multi-storey apartments trap more heat than detached houses, resident-centred evidence is lacking. A cross-sectional questionnaire was administered to 766 adults (378 apartments, 388 detached-house residents) in Greater Irbid Municipality during the June-July 2025 heat season. Instruments captured (i) UHI perceptions, (ii) perceived effectiveness of passive-cooling design features, (iii) mental and physical heat-related health outcomes (PHQ-2, GAD-2, PSS-4, heat-specific sleep and symptom items), and (iv) coping strategies and psychosocial resources. Group differences were tested with independent-samples t-tests. Apartment dwellers reported a stronger neighbourhood UHI (mean 3.44 ± 0.95 vs 3.12 ± 0.95, p < 0.001, d = 0.33) and judged surrounding trees/shade and natural ventilation less effective (Δ ≈ 0.17-0.29 scale units, p ≤ 0.01). They also showed higher perceived stress (PSS-4 8.40 ± 1.35 vs 8.01 ± 1.63, p < 0.001, d = 0.30), shorter sleep duration, and poorer global sleep quality (p ≤ 0.003, d ≈ 0.22). Depression, anxiety, 13 heat-related physical symptoms, coping profiles, and service-stigma indicators were statistically indistinguishable between dwelling types. Living in an Irbid apartment confers a modest psychosocial heat burden-elevated stress and compromised sleep-linked more to perceived shading and ventilation deficits than to housing form alone. Targeted greening, façade reflectance, and cross-ventilation retrofits around apartment blocks could yield meaningful well-being gains without major energy penalties in Jordan's semi-arid urban fabric.
- 20 February 2026
- Published by Springer Nature in Journal of Urban Health
Dwelling Form and Heat-Related Well-Being in a Semi-Arid City: A Cross-Sectional Survey of Apartment and Detached-House Residents in Irbid, Jordan
Rising heat-wave frequency and strong urban-heat-island (UHI) effects threaten thermal comfort and health in Jordan's fast-growing cities. While engineering studies suggest that multi-storey apartments trap more heat than detached houses, resident-centred evidence is lacking. A cross-sectional questionnaire was administered to 766 adults (378 apartments, 388 detached-house residents) in Greater Irbid Municipality during the June-July 2025 heat season. Instruments captured (i) UHI perceptions, (ii) perceived effectiveness of passive-cooling design features, (iii) mental and physical heat-related health outcomes (PHQ-2, GAD-2, PSS-4, heat-specific sleep and symptom items), and (iv) coping strategies and psychosocial resources. Group differences were tested with independent-samples t-tests. Apartment dwellers reported a stronger neighbourhood UHI (mean 3.44 ± 0.95 vs 3.12 ± 0.95, p < 0.001, d = 0.33) and judged surrounding trees/shade and natural ventilation less effective (Δ ≈ 0.17-0.29 scale units, p ≤ 0.01). They also showed higher perceived stress (PSS-4 8.40 ± 1.35 vs 8.01 ± 1.63, p < 0.001, d = 0.30), shorter sleep duration, and poorer global sleep quality (p ≤ 0.003, d ≈ 0.22). Depression, anxiety, 13 heat-related physical symptoms, coping profiles, and service-stigma indicators were statistically indistinguishable between dwelling types. Living in an Irbid apartment confers a modest psychosocial heat burden-elevated stress and compromised sleep-linked more to perceived shading and ventilation deficits than to housing form alone. Targeted greening, façade reflectance, and cross-ventilation retrofits around apartment blocks could yield meaningful well-being gains without major energy penalties in Jordan's semi-arid urban fabric.
- Open Access
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 145200-145212
Explainable Machine Learning for Predicting Healthcare Workers’ Emergency Preparedness Using Disaster-Readiness and Built-Environment Indicators
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 145200-145212
Open AccessExplainable Machine Learning for Predicting Healthcare Workers’ Emergency Preparedness Using Disaster-Readiness and Built-Environment Indicators
- Open Access
- 2 November 2025
- Published by Elsevier in Acta Psychologica
- Vol. 261, 105875
Dental students' visual scene preferences for stress mitigation in clinics: A descriptive study
- 2 November 2025
- Published by Elsevier in Acta Psychologica
- Vol. 261, 105875
Open AccessDental students' visual scene preferences for stress mitigation in clinics: A descriptive study