Mei Wu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Mei Wu has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
Eric Y. Chang
Department of Radiology University of California San Diego CA USA
5 shared publications- Hyungseok Jang
Department of Radiology, University of California, Davis, Sacramento, USA
5 shared publications - Jiang Du
Department of Radiology, University of California San Diego, La Jolla, USA
5 shared publications - Yajun Ma
Department of Radiology University of California San Diego California USA
5 shared publications - Lidi Wan
Department of Radiology University of California San Diego California
2 shared publications - Saeed Jerban
Department of Radiology, University of California, San Diego, La Jolla, CA, USA
2 shared publications
Latest Publications
- Open Access
- 1 January 2021
- Published by Wiley in BioMed Research International
- Vol. 2021 (1) , 4970265
Whole Volume Apparent Diffusion Coefficient (ADC) Histogram as a Quantitative Imaging Biomarker to Differentiate Breast Lesions: Correlation with the Ki‐67 Proliferation Index
Objectives. To evaluate the value of the whole volume apparent diffusion coefficient (ADC) histogram in distinguishing between benign and malignant breast lesions and differentiating different molecular subtypes of breast cancers and to assess the correlation between ADC histogram parameters and Ki‐67 expression in breast cancers. Methods. The institutional review board approved this retrospective study. Between September 2016 and February 2019, 189 patients with 84 benign lesions and 105 breast cancers underwent magnetic resonance imaging (MRI). Volumetric ADC histograms were created by placing regions of interest (ROIs) on the whole lesion. The relationships between the ADC parameters and Ki‐67 were analysed using Spearman’s correlation analysis. Results. Of the 189 breast lesions included, there were significant differences in patient age (P < 0.001) and lesion size (P = 0.006) between the benign and malignant lesions. The results also demonstrated significant differences in all ADC histogram parameters between benign and malignant lesions (all P < 0.001). The median and mean ADC histogram parameters performed better than the other ADC histogram parameters (AUCs were 0.943 and 0.930, respectively). The receiver operating characteristic (ROC) analysis revealed that the 10th percentile ADC value and entropy could determine the human epidermal growth factor receptor 2 (HER‐2) status (both P = 0.001) and estrogen receptor (ER)/progesterone receptor (PR) status (P = 0.020 and P = 0.041, respectively). Among all breast cancer lesions, 35 tumours in the low‐proliferation group (Ki − 67 < 14%) and 70 tumours in the high‐proliferation group (Ki − 67 ≥ 14) were analysed with ROC curves and correlation analyses. The ROC analysis revealed that entropy and skewness could determine the Ki‐67 status (P = 0.007 and P < 0.001, respectively), and there were weak correlations between ADC entropy (r = 0.383) and skewness (r = 0.209) and the Ki‐67 index. Conclusion. The volumetric ADC histogram could serve as an imaging marker to determine breast lesion characteristics and may be a supplemental method in predicting tumour proliferation in breast cancer.
- 1 January 2021
- Published by Wiley in BioMed Research International
- Vol. 2021 (1) , 4970265
Open AccessWhole Volume Apparent Diffusion Coefficient (ADC) Histogram as a Quantitative Imaging Biomarker to Differentiate Breast Lesions: Correlation with the Ki‐67 Proliferation Index
Objectives. To evaluate the value of the whole volume apparent diffusion coefficient (ADC) histogram in distinguishing between benign and malignant breast lesions and differentiating different molecular subtypes of breast cancers and to assess the correlation between ADC histogram parameters and Ki‐67 expression in breast cancers. Methods. The institutional review board approved this retrospective study. Between September 2016 and February 2019, 189 patients with 84 benign lesions and 105 breast cancers underwent magnetic resonance imaging (MRI). Volumetric ADC histograms were created by placing regions of interest (ROIs) on the whole lesion. The relationships between the ADC parameters and Ki‐67 were analysed using Spearman’s correlation analysis. Results. Of the 189 breast lesions included, there were significant differences in patient age (P < 0.001) and lesion size (P = 0.006) between the benign and malignant lesions. The results also demonstrated significant differences in all ADC histogram parameters between benign and malignant lesions (all P < 0.001). The median and mean ADC histogram parameters performed better than the other ADC histogram parameters (AUCs were 0.943 and 0.930, respectively). The receiver operating characteristic (ROC) analysis revealed that the 10th percentile ADC value and entropy could determine the human epidermal growth factor receptor 2 (HER‐2) status (both P = 0.001) and estrogen receptor (ER)/progesterone receptor (PR) status (P = 0.020 and P = 0.041, respectively). Among all breast cancer lesions, 35 tumours in the low‐proliferation group (Ki − 67 < 14%) and 70 tumours in the high‐proliferation group (Ki − 67 ≥ 14) were analysed with ROC curves and correlation analyses. The ROC analysis revealed that entropy and skewness could determine the Ki‐67 status (P = 0.007 and P < 0.001, respectively), and there were weak correlations between ADC entropy (r = 0.383) and skewness (r = 0.209) and the Ki‐67 index. Conclusion. The volumetric ADC histogram could serve as an imaging marker to determine breast lesion characteristics and may be a supplemental method in predicting tumour proliferation in breast cancer.
- 19 May 2020
- Published by Wiley in NMR in Biomedicine
- Vol. 33 (8) , e4322
Magic angle effect on adiabatic T1ρ imaging of the Achilles tendon using 3D ultrashort echo time cones trajectory
The protons in collagen‐rich musculoskeletal (MSK) tissues such as the Achilles tendon are subject to strong dipolar interactions which are modulated by the term (3cos2θ‐1) where θ is the angle between the fiber orientation and the static magnetic field B0. The purpose of this study was to investigate the magic angle effect in three‐dimensional ultrashort echo time Cones Adiabatic T1ρ (3D UTE Cones‐AdiabT1ρ) imaging of the Achilles tendon using a clinical 3 T scanner. The magic angle effect was investigated by Cones‐AdiabT1ρ imaging of five cadaveric human Achilles tendon samples at five angular orientations ranging from 0° to 90° relative to the B0 field. Conventional Cones continuous wave T1ρ (Cones‐CW‐T1ρ) and Cones T2* (Cones‐T2*) sequences were also applied for comparison. On average, Cones‐AdiabT1ρ increased 3.6‐fold from 13.6 ± 1.5 ms at 0° to 48.4 ± 5.4 ms at 55°, Cones‐CW‐T1ρ increased 6.1‐fold from 7.0 ± 1.1 ms at 0° to 42.6 ± 5.2 ms at 55°, and Cones‐T2* increased 12.3‐fold from 2.9 ± 0.5 ms at 0° to 35.8 ± 6.4 ms at 55°. Although Cones‐AdiabT1ρ is still subject to significant angular dependence, it shows a much‐reduced magic angle effect compared to Cones‐CW‐T1ρ and Cones‐T2*, and may be used as a novel and potentially more effective approach for quantitative evaluation of the Achilles tendon and other MSK tissues.
- 19 May 2020
- Published by Wiley in NMR in Biomedicine
- Vol. 33 (8) , e4322
Magic angle effect on adiabatic T1ρ imaging of the Achilles tendon using 3D ultrashort echo time cones trajectory
The protons in collagen‐rich musculoskeletal (MSK) tissues such as the Achilles tendon are subject to strong dipolar interactions which are modulated by the term (3cos2θ‐1) where θ is the angle between the fiber orientation and the static magnetic field B0. The purpose of this study was to investigate the magic angle effect in three‐dimensional ultrashort echo time Cones Adiabatic T1ρ (3D UTE Cones‐AdiabT1ρ) imaging of the Achilles tendon using a clinical 3 T scanner. The magic angle effect was investigated by Cones‐AdiabT1ρ imaging of five cadaveric human Achilles tendon samples at five angular orientations ranging from 0° to 90° relative to the B0 field. Conventional Cones continuous wave T1ρ (Cones‐CW‐T1ρ) and Cones T2* (Cones‐T2*) sequences were also applied for comparison. On average, Cones‐AdiabT1ρ increased 3.6‐fold from 13.6 ± 1.5 ms at 0° to 48.4 ± 5.4 ms at 55°, Cones‐CW‐T1ρ increased 6.1‐fold from 7.0 ± 1.1 ms at 0° to 42.6 ± 5.2 ms at 55°, and Cones‐T2* increased 12.3‐fold from 2.9 ± 0.5 ms at 0° to 35.8 ± 6.4 ms at 55°. Although Cones‐AdiabT1ρ is still subject to significant angular dependence, it shows a much‐reduced magic angle effect compared to Cones‐CW‐T1ρ and Cones‐T2*, and may be used as a novel and potentially more effective approach for quantitative evaluation of the Achilles tendon and other MSK tissues.
- 17 May 2020
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 84 (5) , 2551-2560
Convincing evidence for magic angle less‐sensitive quantitative T1ρ imaging of articular cartilage using the 3D ultrashort echo time cones adiabatic T1ρ (3D UTE cones‐AdiabT1ρ) sequence
Purpose: To investigate the magic angle effect in three‐dimensional ultrashort echo time Cones Adiabatic T1ρ (3D UTE Cones‐AdiabT1ρ) imaging of articular cartilage at 3T.Methods: The magic angle effect was investigated by repeated 3D UTE Cones‐AdiabT1ρ imaging of eight human patellar samples at five angular orientations ranging from 0° to 90° relative to the B0 field. Cones continuous wave T1ρ (Cones‐CW‐T1ρ) and Cones‐ sequences were also applied for comparison. Cones‐AdiabT1ρ, Cones‐CW‐T1ρ and Cones‐ values were measured for four regions of interest (ROIs) (10% superficial layer, 60% transitional layer, 30% radial layer, and a global ROI) for each sample at each orientation to evaluate their angular dependence.Results: 3D UTE Cones‐AdiabT1ρ values increased from the radial layer to the superficial layer for all angular orientations. The superficial layer showed the least angular dependence (around 4.4%), while the radial layer showed the strongest angular dependence (around 34.4%). Cones‐AdiabT1ρ values showed much reduced magic angle effect compared to Cones‐CW‐T1ρ and Cones‐ values for all four ROIs. On average over eight patellae, Cones‐AdiabT1ρ values increased by 27.2% (4.4% for superficial, 23.8% for transitional, and 34.4% for radial layers), Cones‐CW‐T1ρ values increased by 76.9% (11.3% for superficial, 59.1% for transitional, and 117.8% for radial layers), and Cones‐ values increased by 237.5% (87.9% for superficial, 262.9% for transitional, and 327.3% for radial layers) near the magic angle.Conclusions: The 3D UTE Cones‐AdiabT1ρ sequence is less sensitive to the magic angle effect in the evaluation of articular cartilage compared to Cones‐ and Cones‐CW‐T1ρ.
- 17 May 2020
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 84 (5) , 2551-2560
Convincing evidence for magic angle less‐sensitive quantitative T1ρ imaging of articular cartilage using the 3D ultrashort echo time cones adiabatic T1ρ (3D UTE cones‐AdiabT1ρ) sequence
Purpose: To investigate the magic angle effect in three‐dimensional ultrashort echo time Cones Adiabatic T1ρ (3D UTE Cones‐AdiabT1ρ) imaging of articular cartilage at 3T.Methods: The magic angle effect was investigated by repeated 3D UTE Cones‐AdiabT1ρ imaging of eight human patellar samples at five angular orientations ranging from 0° to 90° relative to the B0 field. Cones continuous wave T1ρ (Cones‐CW‐T1ρ) and Cones‐ sequences were also applied for comparison. Cones‐AdiabT1ρ, Cones‐CW‐T1ρ and Cones‐ values were measured for four regions of interest (ROIs) (10% superficial layer, 60% transitional layer, 30% radial layer, and a global ROI) for each sample at each orientation to evaluate their angular dependence.Results: 3D UTE Cones‐AdiabT1ρ values increased from the radial layer to the superficial layer for all angular orientations. The superficial layer showed the least angular dependence (around 4.4%), while the radial layer showed the strongest angular dependence (around 34.4%). Cones‐AdiabT1ρ values showed much reduced magic angle effect compared to Cones‐CW‐T1ρ and Cones‐ values for all four ROIs. On average over eight patellae, Cones‐AdiabT1ρ values increased by 27.2% (4.4% for superficial, 23.8% for transitional, and 34.4% for radial layers), Cones‐CW‐T1ρ values increased by 76.9% (11.3% for superficial, 59.1% for transitional, and 117.8% for radial layers), and Cones‐ values increased by 237.5% (87.9% for superficial, 262.9% for transitional, and 327.3% for radial layers) near the magic angle.Conclusions: The 3D UTE Cones‐AdiabT1ρ sequence is less sensitive to the magic angle effect in the evaluation of articular cartilage compared to Cones‐ and Cones‐CW‐T1ρ.
- 10 January 2020
- Published by SAGE Publications in Acta Radiologica
- Vol. 61 (9) , 1165-1175
Diagnostic performance of whole-lesion apparent diffusion coefficient histogram analysis metrics for differentiating benign and malignant breast lesions: a systematic review and diagnostic meta-analysis
Although whole-lesion apparent diffusion coefficient (ADC) histogram has been increasingly used for breast lesions, it has not been routinely used in clinical practice as an emergent promising imaging tool. To evaluate the performance of whole-lesion ADC histogram analysis metrics for differentiating benign and malignant breast lesions. A systematic PubMed/EMBASE/Cochrane electronic database search was performed for original diagnostic studies from 1 January 1970 to 2 January 2019. Summary estimates of diagnostic accuracy were generated and meta-regression was performed to explore sources of heterogeneity according to study and magnetic resonance imaging characteristics. Five original articles involving 493 patients were included in the meta-analysis. The pooled sensitivity and specificity of whole-lesion ADC histogram analysis were 0.85 (95% confidence interval [CI] = 0.81–0.89) and 0.79 (95% CI = 0.72–0.84) for distinguishing benign and malignant breast lesions, respectively. The area under the curve (AUC) was 0.9178. No publication bias was detected (P = 0.51). In subgroup analysis, the summary sensitivity and specificity of 50th percentile ADC value were 0.81 (95% CI = 0.71–0.88) and 0.86 (95% CI = 0.74–0.94), respectively. Meta-regression analysis indicated no covariates were sources of heterogeneity (P > 0.05). Whole-lesion ADC histogram analysis demonstrated good diagnostic performance for differentiating between benign and malignant breast lesions, with 50th percentile ADC value showing higher diagnostic accuracy than other histogram parameters. Given the limited number of studies included in the analysis, the findings from our meta-analysis will need further confirmation in future research.
- 10 January 2020
- Published by SAGE Publications in Acta Radiologica
- Vol. 61 (9) , 1165-1175
Diagnostic performance of whole-lesion apparent diffusion coefficient histogram analysis metrics for differentiating benign and malignant breast lesions: a systematic review and diagnostic meta-analysis
Although whole-lesion apparent diffusion coefficient (ADC) histogram has been increasingly used for breast lesions, it has not been routinely used in clinical practice as an emergent promising imaging tool. To evaluate the performance of whole-lesion ADC histogram analysis metrics for differentiating benign and malignant breast lesions. A systematic PubMed/EMBASE/Cochrane electronic database search was performed for original diagnostic studies from 1 January 1970 to 2 January 2019. Summary estimates of diagnostic accuracy were generated and meta-regression was performed to explore sources of heterogeneity according to study and magnetic resonance imaging characteristics. Five original articles involving 493 patients were included in the meta-analysis. The pooled sensitivity and specificity of whole-lesion ADC histogram analysis were 0.85 (95% confidence interval [CI] = 0.81–0.89) and 0.79 (95% CI = 0.72–0.84) for distinguishing benign and malignant breast lesions, respectively. The area under the curve (AUC) was 0.9178. No publication bias was detected (P = 0.51). In subgroup analysis, the summary sensitivity and specificity of 50th percentile ADC value were 0.81 (95% CI = 0.71–0.88) and 0.86 (95% CI = 0.74–0.94), respectively. Meta-regression analysis indicated no covariates were sources of heterogeneity (P > 0.05). Whole-lesion ADC histogram analysis demonstrated good diagnostic performance for differentiating between benign and malignant breast lesions, with 50th percentile ADC value showing higher diagnostic accuracy than other histogram parameters. Given the limited number of studies included in the analysis, the findings from our meta-analysis will need further confirmation in future research.
- 20 November 2019
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 83 (4) , 1168-1177
Improved volumetric myelin imaging in human brain using 3D dual echo inversion recovery‐prepared UTE with complex echo subtraction
Purpose: Inversion recovery‐based UTE (IR‐UTE) sequences have been proposed to directly image myelin with extremely short (~0.3 ms). In this study, we demonstrate the feasibility of complex echo subtraction to improve 3D IR‐UTE imaging of myelin in white matter of the brain in vivo.Methods: In IR‐UTE imaging, long T2 components in white matter (i.e., water) are suppressed using an adiabatic inversion recovery preparation pulse. Dual echo UTE data acquisition and magnitude echo subtraction are used to suppress the residual white matter and gray matter signals, providing high myelin contrast. Complex echo subtraction may further improve the myelin contrast by reducing the residual long T2 water signal contamination caused by regional T1 variations. To verify the efficacy of the complex subtraction technique, in vivo experiments were performed with 5 non‐symptomatic healthy volunteers and 5 multiple sclerosis patients on a 3T clinical MR system. Signal enhancement between the complex subtraction and the magnitude subtraction was introduced to evaluate the improvement.Results: The complex subtraction improved myelin contrast over the magnitude subtraction in both healthy and patient groups, with more fine myelin structures being revealed. The foci of the demyelinated lesion were more clearly detected by complex subtraction. An average signal enhancement of up to 135.9% was achieved with the complex subtraction over the magnitude subtraction.Conclusion: The complex echo subtraction improves 3D IR‐UTE morphologic imaging of myelin in white matter of the brain.
- 20 November 2019
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 83 (4) , 1168-1177
Improved volumetric myelin imaging in human brain using 3D dual echo inversion recovery‐prepared UTE with complex echo subtraction
Purpose: Inversion recovery‐based UTE (IR‐UTE) sequences have been proposed to directly image myelin with extremely short (~0.3 ms). In this study, we demonstrate the feasibility of complex echo subtraction to improve 3D IR‐UTE imaging of myelin in white matter of the brain in vivo.Methods: In IR‐UTE imaging, long T2 components in white matter (i.e., water) are suppressed using an adiabatic inversion recovery preparation pulse. Dual echo UTE data acquisition and magnitude echo subtraction are used to suppress the residual white matter and gray matter signals, providing high myelin contrast. Complex echo subtraction may further improve the myelin contrast by reducing the residual long T2 water signal contamination caused by regional T1 variations. To verify the efficacy of the complex subtraction technique, in vivo experiments were performed with 5 non‐symptomatic healthy volunteers and 5 multiple sclerosis patients on a 3T clinical MR system. Signal enhancement between the complex subtraction and the magnitude subtraction was introduced to evaluate the improvement.Results: The complex subtraction improved myelin contrast over the magnitude subtraction in both healthy and patient groups, with more fine myelin structures being revealed. The foci of the demyelinated lesion were more clearly detected by complex subtraction. An average signal enhancement of up to 135.9% was achieved with the complex subtraction over the magnitude subtraction.Conclusion: The complex echo subtraction improves 3D IR‐UTE morphologic imaging of myelin in white matter of the brain.
- 12 November 2019
- Published by Wiley in NMR in Biomedicine
- Vol. 33 (1) , e4214
Quantitative three‐dimensional ultrashort echo time cones imaging of the knee joint with motion correction
Knee degeneration involves all the major tissues in the joint. However, conventional MRI sequences can only detect signals from long T2 tissues such as the superficial cartilage, with little signal from the deep cartilage, menisci, ligaments, tendons and bone. It is highly desirable to develop new sequences that can detect signal from all major tissues in the knee.We aimed to develop a comprehensive quantitative three‐dimensional ultrashort echo time (3D UTE) cones imaging protocol for a truly “whole joint” evaluation of knee degeneration. The protocol included 3D UTE cones actual flip angle imaging (3D UTE‐Cones‐AFI) for T1 mapping, multiecho UTE‐Cones with fat suppression for T2* mapping, UTE‐Cones with adiabatic T1ρ (AdiabT1ρ) preparation for AdiabT1ρ mapping, and UTE‐Cones magnetization transfer (UTE‐Cones‐MT) for MT ratio (MTR) and modeling of macromolecular proton fraction (f). An elastix registration technique was used to compensate for motion during scans. Quantitative data analyses were performed on the registered data. Three knee specimens and 15 volunteers were evaluated at 3 T.The elastix motion correction algorithm worked well in correcting motion artifacts associated with relatively long scan times. Much improved curve fitting was achieved for all UTE‐Cones biomarkers with greatly reduced root mean square errors. The averaged T1, T2*, AdiabT1ρ, MTR and f for knee joint tissues of 15 healthy volunteers were reported.The 3D UTE‐Cones quantitative imaging techniques (ie, T1, T2*, AdiabT1ρ, MTR and MT modeling) together with elastix motion correction provide robust volumetric measurement of relaxation times, MTR and f of both short and long T2 tissues in the knee joint.
- 12 November 2019
- Published by Wiley in NMR in Biomedicine
- Vol. 33 (1) , e4214
Quantitative three‐dimensional ultrashort echo time cones imaging of the knee joint with motion correction
Knee degeneration involves all the major tissues in the joint. However, conventional MRI sequences can only detect signals from long T2 tissues such as the superficial cartilage, with little signal from the deep cartilage, menisci, ligaments, tendons and bone. It is highly desirable to develop new sequences that can detect signal from all major tissues in the knee.We aimed to develop a comprehensive quantitative three‐dimensional ultrashort echo time (3D UTE) cones imaging protocol for a truly “whole joint” evaluation of knee degeneration. The protocol included 3D UTE cones actual flip angle imaging (3D UTE‐Cones‐AFI) for T1 mapping, multiecho UTE‐Cones with fat suppression for T2* mapping, UTE‐Cones with adiabatic T1ρ (AdiabT1ρ) preparation for AdiabT1ρ mapping, and UTE‐Cones magnetization transfer (UTE‐Cones‐MT) for MT ratio (MTR) and modeling of macromolecular proton fraction (f). An elastix registration technique was used to compensate for motion during scans. Quantitative data analyses were performed on the registered data. Three knee specimens and 15 volunteers were evaluated at 3 T.The elastix motion correction algorithm worked well in correcting motion artifacts associated with relatively long scan times. Much improved curve fitting was achieved for all UTE‐Cones biomarkers with greatly reduced root mean square errors. The averaged T1, T2*, AdiabT1ρ, MTR and f for knee joint tissues of 15 healthy volunteers were reported.The 3D UTE‐Cones quantitative imaging techniques (ie, T1, T2*, AdiabT1ρ, MTR and MT modeling) together with elastix motion correction provide robust volumetric measurement of relaxation times, MTR and f of both short and long T2 tissues in the knee joint.
- 19 September 2019
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 83 (3) , 1109-1122
Knee menisci segmentation and relaxometry of 3D ultrashort echo time cones MR imaging using attention U‐Net with transfer learning
Purpose: To develop a deep learning‐based method for knee menisci segmentation in 3D ultrashort echo time (UTE) cones MR imaging, and to automatically determine MR relaxation times, namely the T1, T1ρ, and parameters, which can be used to assess knee osteoarthritis (OA).Methods: Whole knee joint imaging was performed using 3D UTE cones sequences to collect data from 61 human subjects. Regions of interest (ROIs) were outlined by 2 experienced radiologists based on subtracted T1ρ‐weighted MR images. Transfer learning was applied to develop 2D attention U‐Net convolutional neural networks for the menisci segmentation based on each radiologist's ROIs separately. Dice scores were calculated to assess segmentation performance. Next, the T1, T1ρ, relaxations, and ROI areas were determined for the manual and automatic segmentations, then compared.Results: The models developed using ROIs provided by 2 radiologists achieved high Dice scores of 0.860 and 0.833, while the radiologists’ manual segmentations achieved a Dice score of 0.820. Linear correlation coefficients for the T1, T1ρ, and relaxations calculated using the automatic and manual segmentations ranged between 0.90 and 0.97, and there were no associated differences between the estimated average meniscal relaxation parameters. The deep learning models achieved segmentation performance equivalent to the inter‐observer variability of 2 radiologists.Conclusion: The proposed deep learning‐based approach can be used to efficiently generate automatic segmentations and determine meniscal relaxations times. The method has the potential to help radiologists with the assessment of meniscal diseases, such as OA.
- 19 September 2019
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 83 (3) , 1109-1122
Knee menisci segmentation and relaxometry of 3D ultrashort echo time cones MR imaging using attention U‐Net with transfer learning
Purpose: To develop a deep learning‐based method for knee menisci segmentation in 3D ultrashort echo time (UTE) cones MR imaging, and to automatically determine MR relaxation times, namely the T1, T1ρ, and parameters, which can be used to assess knee osteoarthritis (OA).Methods: Whole knee joint imaging was performed using 3D UTE cones sequences to collect data from 61 human subjects. Regions of interest (ROIs) were outlined by 2 experienced radiologists based on subtracted T1ρ‐weighted MR images. Transfer learning was applied to develop 2D attention U‐Net convolutional neural networks for the menisci segmentation based on each radiologist's ROIs separately. Dice scores were calculated to assess segmentation performance. Next, the T1, T1ρ, relaxations, and ROI areas were determined for the manual and automatic segmentations, then compared.Results: The models developed using ROIs provided by 2 radiologists achieved high Dice scores of 0.860 and 0.833, while the radiologists’ manual segmentations achieved a Dice score of 0.820. Linear correlation coefficients for the T1, T1ρ, and relaxations calculated using the automatic and manual segmentations ranged between 0.90 and 0.97, and there were no associated differences between the estimated average meniscal relaxation parameters. The deep learning models achieved segmentation performance equivalent to the inter‐observer variability of 2 radiologists.Conclusion: The proposed deep learning‐based approach can be used to efficiently generate automatic segmentations and determine meniscal relaxations times. The method has the potential to help radiologists with the assessment of meniscal diseases, such as OA.