Ziqiao Lei
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ziqiao Lei has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
Lan Cheng
Department of Radiology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430022, China
2 shared publications- Ming Yang
Department of Radiology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, China; Hubei Province Key Laboratory of Molecular Imaging, Wuhan, Hubei, China
2 shared publications Shuai Yang
Department of Radiology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430022, China
2 shared publications- Zhuang Nie
Department of Radiology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
2 shared publications Chanyuan Liu
Department of Radiology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
1 shared publication- Chong Chen
Department of Radiology Union Hospital Tongji Medical College Huazhong University of Science & Technology 1277 Jiefang Ave. Wuhan China
1 shared publication
Latest Publications
- Open Access
- 12 October 2026
- Published by BMJ in Journal for ImmunoTherapy of Cancer
- Vol. 14 (10) , e014952
AI-derived 3D body composition predicts prognosis of chemoimmunotherapy in small cell lung cancer: a multicenter study
Background Small cell lung cancer (SCLC) has a poor prognosis despite standard first-line chemoimmunotherapy. Reliable, non-invasive biomarkers for risk stratification are urgently needed. Three-dimensional (3D) body composition (BC) analysis from chest CT scans offers a promising approach to assess systemic metabolic status.Methods In this multicenter study, we analyzed patients treated with first-line chemoimmunotherapy across five institutions. Using a deep learning model, 3D BC parameters were automatically extracted from baseline chest CTs. We evaluated their associations with overall survival (OS) and progression-free survival using Kaplan-Meier and Cox regression analyses. A total of 101 machine learning model configurations were evaluated to develop predictive models, and the SHapley Additive exPlanations method was applied to enhance model interpretability. Additionally, we investigated the association between BC parameters and CD8 + T-cell infiltration in the tumor microenvironment.Results Among 575 patients (training: 161; internal validation: 69; external validation: 345), all four 3D BC indices significantly stratified OS. Multivariable Cox analysis showed that higher skeletal muscle volume index was independently associated with better OS (HR=0.956, 95% CI 0.928 to 0.985, p=0.003), whereas higher visceral fat volume index was associated with worse OS (HR=1.017, 95% CI 1.002 to 1.032, p=0.026). 3D BC provided more pronounced prognostic stratification than conventional two-dimensional measures and body mass index. The selected linear discriminant analysis model achieved area under the curves of 0.756, 0.781, and 0.783 in the training, internal validation, and external validation cohorts, respectively. In an exploratory subset of 35 patients, higher skeletal muscle volume index was associated with increased intratumoral CD8+T cell density.Conclusions Higher skeletal muscle volume index was associated with better OS, whereas higher visceral fat volume index was associated with worse OS. Automated 3D BC may provide complementary non-invasive prognostic information in patients with SCLC receiving first-line chemoimmunotherapy.
- 12 October 2026
- Published by BMJ in Journal for ImmunoTherapy of Cancer
- Vol. 14 (10) , e014952
Open AccessAI-derived 3D body composition predicts prognosis of chemoimmunotherapy in small cell lung cancer: a multicenter study
Background Small cell lung cancer (SCLC) has a poor prognosis despite standard first-line chemoimmunotherapy. Reliable, non-invasive biomarkers for risk stratification are urgently needed. Three-dimensional (3D) body composition (BC) analysis from chest CT scans offers a promising approach to assess systemic metabolic status.Methods In this multicenter study, we analyzed patients treated with first-line chemoimmunotherapy across five institutions. Using a deep learning model, 3D BC parameters were automatically extracted from baseline chest CTs. We evaluated their associations with overall survival (OS) and progression-free survival using Kaplan-Meier and Cox regression analyses. A total of 101 machine learning model configurations were evaluated to develop predictive models, and the SHapley Additive exPlanations method was applied to enhance model interpretability. Additionally, we investigated the association between BC parameters and CD8 + T-cell infiltration in the tumor microenvironment.Results Among 575 patients (training: 161; internal validation: 69; external validation: 345), all four 3D BC indices significantly stratified OS. Multivariable Cox analysis showed that higher skeletal muscle volume index was independently associated with better OS (HR=0.956, 95% CI 0.928 to 0.985, p=0.003), whereas higher visceral fat volume index was associated with worse OS (HR=1.017, 95% CI 1.002 to 1.032, p=0.026). 3D BC provided more pronounced prognostic stratification than conventional two-dimensional measures and body mass index. The selected linear discriminant analysis model achieved area under the curves of 0.756, 0.781, and 0.783 in the training, internal validation, and external validation cohorts, respectively. In an exploratory subset of 35 patients, higher skeletal muscle volume index was associated with increased intratumoral CD8+T cell density.Conclusions Higher skeletal muscle volume index was associated with better OS, whereas higher visceral fat volume index was associated with worse OS. Automated 3D BC may provide complementary non-invasive prognostic information in patients with SCLC receiving first-line chemoimmunotherapy.
- Open Access
- 17 June 2026
- Published by Springer Nature in BMC Medical Imaging
- Vol. 26 (1)
Grading knee cartilage degeneration and meniscal injury with combined ACS-accelerated T1ρ and T2 mapping
To evaluate the diagnostic performance of artificial intelligence-compressed sensing (ACS)-accelerated T1ρ mapping combined with conventional T2 mapping for quantitative differentiation of articular cartilage degeneration and meniscal injury severity in knee osteoarthritis (KOA). We prospectively enrolled 56 KOA patients and 30 age-matched healthy volunteers between August 2025 and February 2026. All underwent 3T knee MRI using ACS T1ρ and conventional T2 mapping. Relaxation times were quantified in predefined cartilage and meniscal regions. Cartilage degeneration was classified by Kellgren-Lawrence (K-L) grade: 0 (normal), I-II (mild), and III-IV (severe). Meniscal injury was graded using the Stoller system: 0 (normal), I-II (mild), and III (severe). Group and subgroup comparisons used appropriate statistical tests. T1ρ and T2 values were significantly elevated in KOA versus controls across all regions (P < 0.05). Within KOA, relaxation times differed significantly between mild and severe subgroups (P < 0.05). For cartilage degeneration, AUCs were 0.948 (95% CI: 0.889-1.000) for ACS T1ρ, 0.867 (95% CI: 0.760-0.975) for T2, and 0.964 (95% CI: 0.922-1.000) for the combined model. For meniscal injury, AUCs were 0.851 (95% CI: 0.779-0.922) for ACS T1ρ, 0.802 (95% CI: 0.720-0.885) for T2, and 0.855 (95% CI: 0.784-0.926) for the combined approach. Integrating ACS T1ρ and T2 mapping enables precise, quantitative stratification of cartilage and meniscal pathology across KOA severity levels, offering comprehensive biochemical assessment prior to morphological changes and highlighting its potential for early intervention and stage-based management.
- 17 June 2026
- Published by Springer Nature in BMC Medical Imaging
- Vol. 26 (1)
Open AccessGrading knee cartilage degeneration and meniscal injury with combined ACS-accelerated T1ρ and T2 mapping
To evaluate the diagnostic performance of artificial intelligence-compressed sensing (ACS)-accelerated T1ρ mapping combined with conventional T2 mapping for quantitative differentiation of articular cartilage degeneration and meniscal injury severity in knee osteoarthritis (KOA). We prospectively enrolled 56 KOA patients and 30 age-matched healthy volunteers between August 2025 and February 2026. All underwent 3T knee MRI using ACS T1ρ and conventional T2 mapping. Relaxation times were quantified in predefined cartilage and meniscal regions. Cartilage degeneration was classified by Kellgren-Lawrence (K-L) grade: 0 (normal), I-II (mild), and III-IV (severe). Meniscal injury was graded using the Stoller system: 0 (normal), I-II (mild), and III (severe). Group and subgroup comparisons used appropriate statistical tests. T1ρ and T2 values were significantly elevated in KOA versus controls across all regions (P < 0.05). Within KOA, relaxation times differed significantly between mild and severe subgroups (P < 0.05). For cartilage degeneration, AUCs were 0.948 (95% CI: 0.889-1.000) for ACS T1ρ, 0.867 (95% CI: 0.760-0.975) for T2, and 0.964 (95% CI: 0.922-1.000) for the combined model. For meniscal injury, AUCs were 0.851 (95% CI: 0.779-0.922) for ACS T1ρ, 0.802 (95% CI: 0.720-0.885) for T2, and 0.855 (95% CI: 0.784-0.926) for the combined approach. Integrating ACS T1ρ and T2 mapping enables precise, quantitative stratification of cartilage and meniscal pathology across KOA severity levels, offering comprehensive biochemical assessment prior to morphological changes and highlighting its potential for early intervention and stage-based management.
- Open Access
- 1 December 2024
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 14 (12) , 9101-9111
Intravoxel incoherent motion diffusion-weighted imaging in nasopharyngeal carcinoma: comparison of the turbo spin-echo and echo-planar imaging techniques
Background: Traditional echo-planar imaging with intravoxel incoherent motion (EPI-IVIM) exhibits significant magnetic susceptibility artifacts and geometric distortions, which limits its application in nasopharyngeal carcinoma (NPC). This study aimed to compare the qualitative and quantitative indicators between turbo spin echo with intravoxel incoherent motion (TSE-IVIM) and EPI-IVIM in patients with NPC and to provide optimal scanning strategies based on the relationships among these indicators. Methods: A cross-sectional study was conducted between March 2022 and August 2022. Patients with pathologically confirmed NPC underwent pretreatment staging magnetic resonance (MR) examinations with both TSE-IVIM and EPI-IVIM. IVIM images were subjectively and objectively assessed for anatomical structures including nasopharyngeal lesions, nasal concha, the spinal cord, and the temporal pole. Subjective evaluation indicators (including susceptibility artifacts, geometric distortion, lesion conspicuity, and overall image quality on a five-point scale) were compared using the Wilcoxon signed rank test. Quantitative indicators, including signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), apparent diffusion coefficient (ADC), and IVIM-derived parameters (true diffusion coefficients, perfusion fraction, pseudodiffusion coefficient), were compared using the Wilcoxon signed rank test. Bland-Altman plots and coefficient of variation (CV) were used to compare the reproducibility and robustness of the ADC and IVIM-derived parameters between TSE-IVIM and EPI-IVIM. Results: A total of 30 patients (24 males and 6 females) aged between 29 and 71 years (mean age 47.6±12.3 years) were included in the study. TSE-IVIM demonstrated significantly better subjective evaluation indicators for nasopharyngeal lesions, nasal concha, and temporal poles as compared to EPI-IVIM (all P values Conclusions: TSE-IVIM provided better subjective image quality scores and a significantly higher CNR, with no significant reduction in SNR. It demonstrated superior image quality and more stable quantitative indicators for nasopharyngeal lesions and nasal concha although magnetic sensitivity artifacts were more noticeable. Due to the different f values and wide LoAs observed between the two sequences in nasopharyngeal lesions, TSE-IVIM is recommended for follow-up in patients with NPC.
- 1 December 2024
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 14 (12) , 9101-9111
Open AccessIntravoxel incoherent motion diffusion-weighted imaging in nasopharyngeal carcinoma: comparison of the turbo spin-echo and echo-planar imaging techniques
Background: Traditional echo-planar imaging with intravoxel incoherent motion (EPI-IVIM) exhibits significant magnetic susceptibility artifacts and geometric distortions, which limits its application in nasopharyngeal carcinoma (NPC). This study aimed to compare the qualitative and quantitative indicators between turbo spin echo with intravoxel incoherent motion (TSE-IVIM) and EPI-IVIM in patients with NPC and to provide optimal scanning strategies based on the relationships among these indicators. Methods: A cross-sectional study was conducted between March 2022 and August 2022. Patients with pathologically confirmed NPC underwent pretreatment staging magnetic resonance (MR) examinations with both TSE-IVIM and EPI-IVIM. IVIM images were subjectively and objectively assessed for anatomical structures including nasopharyngeal lesions, nasal concha, the spinal cord, and the temporal pole. Subjective evaluation indicators (including susceptibility artifacts, geometric distortion, lesion conspicuity, and overall image quality on a five-point scale) were compared using the Wilcoxon signed rank test. Quantitative indicators, including signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), apparent diffusion coefficient (ADC), and IVIM-derived parameters (true diffusion coefficients, perfusion fraction, pseudodiffusion coefficient), were compared using the Wilcoxon signed rank test. Bland-Altman plots and coefficient of variation (CV) were used to compare the reproducibility and robustness of the ADC and IVIM-derived parameters between TSE-IVIM and EPI-IVIM. Results: A total of 30 patients (24 males and 6 females) aged between 29 and 71 years (mean age 47.6±12.3 years) were included in the study. TSE-IVIM demonstrated significantly better subjective evaluation indicators for nasopharyngeal lesions, nasal concha, and temporal poles as compared to EPI-IVIM (all P values Conclusions: TSE-IVIM provided better subjective image quality scores and a significantly higher CNR, with no significant reduction in SNR. It demonstrated superior image quality and more stable quantitative indicators for nasopharyngeal lesions and nasal concha although magnetic sensitivity artifacts were more noticeable. Due to the different f values and wide LoAs observed between the two sequences in nasopharyngeal lesions, TSE-IVIM is recommended for follow-up in patients with NPC.
- 22 January 2022
- Published by Springer Nature in Clinical Neuroradiology
- Vol. 32 (3) , 687-694
A Novel Subtraction Method to Reduce Metal Artifacts of Cerebral Aneurysm Embolism Coils
Objective To investigate a novel subtraction method (S-MAR), combing metal artifact reduction (MAR), virtual monochromatic imaging (VMI), and subtraction CT angiography (CTA) to remove the metal artifacts of coils after endovascular embolotherapy of intracranial aneurysms. Method In this retrospective study, 29 patients with 38 coils after endovascular embolotherapy of intracranial aneurysms who underwent cerebral CTA using a dual-layer detector spectral CT were included. Conventional CT images (CI), virtual non-enhanced (VNC) images and VMI ranging from 40 to 120 KeV in steps of 10 were reconstructed. These images were then postprocessed to CIMAR, VMIMAR and VNCMAR with MAR software (O-MAR; Philips Healthcare, Cleveland, OH, USA). The novel subtraction method (S-MAR) was derived from subtraction imaging between VNCMAR and the optimal VMIMAR. Contrast-to-noise (CNR) and Noise(Background) of CI, CIMAR, VMI, and VMIMAR were calculated quantitatively. Two Independent radiologists qualitatively assessed artifacts in all images using coil artifact score (CA score), a 5-point Likert scale. Besides, all coils were divided into two groups (group 1: diameter < 5.0 mm, group 2: diameter ≥ 5.0 mm). Differences between two groups were statistically analyzed. Results The optimal KeV was 40 KeV. Strong correlations between diameter of coils and the CA score of CI were found (rs = 0.652, P < 0.05). CNR, Noise and CA score were significantly improved by CIMAR and VMIMAR compared with CI (P < 0.05). The S‑MAR showed significantly better performance compared with CI, CIMAR, VMI, and VMIMAR in reducing metal coil artifacts according to the CA score (P < 0.05), especially in group 2. Conclusion The novel S‑MAR proved to be a promising method to reduce coil metal artifacts and elevate the vessel visualization adjacent to coils. It could develop to be widely used in cerebral CTA after coiled aneurysms.
- 22 January 2022
- Published by Springer Nature in Clinical Neuroradiology
- Vol. 32 (3) , 687-694
A Novel Subtraction Method to Reduce Metal Artifacts of Cerebral Aneurysm Embolism Coils
Objective To investigate a novel subtraction method (S-MAR), combing metal artifact reduction (MAR), virtual monochromatic imaging (VMI), and subtraction CT angiography (CTA) to remove the metal artifacts of coils after endovascular embolotherapy of intracranial aneurysms. Method In this retrospective study, 29 patients with 38 coils after endovascular embolotherapy of intracranial aneurysms who underwent cerebral CTA using a dual-layer detector spectral CT were included. Conventional CT images (CI), virtual non-enhanced (VNC) images and VMI ranging from 40 to 120 KeV in steps of 10 were reconstructed. These images were then postprocessed to CIMAR, VMIMAR and VNCMAR with MAR software (O-MAR; Philips Healthcare, Cleveland, OH, USA). The novel subtraction method (S-MAR) was derived from subtraction imaging between VNCMAR and the optimal VMIMAR. Contrast-to-noise (CNR) and Noise(Background) of CI, CIMAR, VMI, and VMIMAR were calculated quantitatively. Two Independent radiologists qualitatively assessed artifacts in all images using coil artifact score (CA score), a 5-point Likert scale. Besides, all coils were divided into two groups (group 1: diameter < 5.0 mm, group 2: diameter ≥ 5.0 mm). Differences between two groups were statistically analyzed. Results The optimal KeV was 40 KeV. Strong correlations between diameter of coils and the CA score of CI were found (rs = 0.652, P < 0.05). CNR, Noise and CA score were significantly improved by CIMAR and VMIMAR compared with CI (P < 0.05). The S‑MAR showed significantly better performance compared with CI, CIMAR, VMI, and VMIMAR in reducing metal coil artifacts according to the CA score (P < 0.05), especially in group 2. Conclusion The novel S‑MAR proved to be a promising method to reduce coil metal artifacts and elevate the vessel visualization adjacent to coils. It could develop to be widely used in cerebral CTA after coiled aneurysms.
- 8 July 2021
- Published by Taylor & Francis in Future Virology
- Vol. 16 (7) , 459-466
Association of Anemia and COVID-19 in Hospitalized Patients
Aim: COVID-19 is a major threat to public health worldwide. A large proportion of COVID-19 patients is proved to develop anemia. Herein, we investigate the association between anemia and severe pne...
- 8 July 2021
- Published by Taylor & Francis in Future Virology
- Vol. 16 (7) , 459-466
Association of Anemia and COVID-19 in Hospitalized Patients
Aim: COVID-19 is a major threat to public health worldwide. A large proportion of COVID-19 patients is proved to develop anemia. Herein, we investigate the association between anemia and severe pne...
- 1 February 2019
- Published by Springer Nature in Current Medical Science
- Vol. 39 (1) , 146-152
Diagnostic Value of 128-slice Spiral CT Combined with Virtual Colonoscopy for Colorectal Cancer
The objective of this study was to evaluate the diagnostic value of 128-slice spiral CT combined with virtual colonoscopy in diagnosis of colorectal cancer. We retrospectively analyzed 45 patients of colorectal diseases who underwent definition AS+128-slice spiral CT combined with virtual colonoscopy after bowel preparation and gas injection to evaluate the clinical diagnostic value of this technology. All the patients received electronic colonoscopy and were confirmed by pathology. In total, colorectal cancer was confirmed in 42 cases and inflammation in 3 cases. Diagnostic results shows: there were 17 cases of lump, 10 cases of infiltration, 6 cases of ulcer, 9 cases of mixed type, 4 cases of liver metastases, and 36 cases of lymph node metastasis. There was no significant difference between 128-slice spiral CT combined with virtual colonoscopy and electronic colonoscopy in detection, localization and characterization of colorectal tumors. CT virtual endoscopy has great advantages in observing the invasion around the lesion and the presence or absence of metastasis in distant organs and lymph node metastasis. It is also possible to understand the shape of the lesion in the intestinal lumen and the length of the lesion involving the lumen of the intestine.
- 1 February 2019
- Published by Springer Nature in Current Medical Science
- Vol. 39 (1) , 146-152
Diagnostic Value of 128-slice Spiral CT Combined with Virtual Colonoscopy for Colorectal Cancer
The objective of this study was to evaluate the diagnostic value of 128-slice spiral CT combined with virtual colonoscopy in diagnosis of colorectal cancer. We retrospectively analyzed 45 patients of colorectal diseases who underwent definition AS+128-slice spiral CT combined with virtual colonoscopy after bowel preparation and gas injection to evaluate the clinical diagnostic value of this technology. All the patients received electronic colonoscopy and were confirmed by pathology. In total, colorectal cancer was confirmed in 42 cases and inflammation in 3 cases. Diagnostic results shows: there were 17 cases of lump, 10 cases of infiltration, 6 cases of ulcer, 9 cases of mixed type, 4 cases of liver metastases, and 36 cases of lymph node metastasis. There was no significant difference between 128-slice spiral CT combined with virtual colonoscopy and electronic colonoscopy in detection, localization and characterization of colorectal tumors. CT virtual endoscopy has great advantages in observing the invasion around the lesion and the presence or absence of metastasis in distant organs and lymph node metastasis. It is also possible to understand the shape of the lesion in the intestinal lumen and the length of the lesion involving the lumen of the intestine.