Chun Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Chun Zhang has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
Huimei Yu
Department of Interventional Ultrasound, Beijing Anzhen Hospital, Capital Medical University, Beijing, China
3 shared publicationsJiarong Fu
Department of Interventional Ultrasound, Beijing Anzhen Hospital, Capital Medical University, Beijing, China
3 shared publicationsJinfeng Liu
Department of Interventional Ultrasound, Beijing Anzhen Hospital, Capital Medical University, Beijing, China
3 shared publicationsShan Wu
Department of Interventional Ultrasound, Beijing Anzhen Hospital, Capital Medical University, Beijing, China
3 shared publicationsXiaoming Li
Department of Interventional Ultrasound, Beijing Anzhen Hospital, Capital Medical University, Beijing, China
3 shared publicationsLili Tang
Department of Interventional Ultrasound, Beijing Anzhen Hospital, Capital Medical University, Beijing, China
2 shared publications
Latest Publications
New wearable cardiac acoustic monitoring technology for evaluation of subclinical leaflet thrombosis after transcatheter aortic valve replacement
Background Subclinical leaflet thrombosis (SLT) is a common complication after transcatheter aortic valve replacement (TAVR). Multidimensional CT (MDCT) is the main imaging mortality for the diagnosis of SLT but it enhances the risk of contrast-induced nephropathy. Our study aimed to use an innovative wearable acoustic cardiography (ACG) device to diagnose SLT as an alternative option. Methods This prospective cohort study consecutively enrolled patients with severe symptomatic aortic stenosis who underwent successful TAVR. We collected and analysed clinical data including ACG measurements and imaging results. Discrimination capability analysis (ie, area under the curve (AUC), sensitivity, specificity) of a composite feature from ACG readings in predicting SLT during follow-up was performed. Based on the severity of SLT, patients were categorised into three groups: Group 1 (no SLT), Group 2 (mild SLT) and Group 3 (moderate-to-severe SLT). Results 116 patients consented and enrolled in the study. At the 1-month follow-up, MDCT revealed a 25% prevalence of SLT with 11.2% classified as moderate-to-severe. ACG analysis revealed distinctive patterns of early systolic, baseless and high-energy murmurs exclusively in patients in Group 3 but not in group 2. The diagnostic performance of ACG for moderate-to-severe SLT showed a sensitivity of 84.62%, specificity of 91.26% and AUC of 0.920 (95% CI: 0.855 to 0.962, pConclusion ACG can be considered as an effective tool to assist in the diagnosis of SLT based on deterioration of transvalvular haemodynamics post-TAVR. Further studies are required to confirm its utility as a valuable non-invasive diagnostic and monitoring tool. Trial registration number ChiCTR2300072300.
New wearable cardiac acoustic monitoring technology for evaluation of subclinical leaflet thrombosis after transcatheter aortic valve replacement
Background Subclinical leaflet thrombosis (SLT) is a common complication after transcatheter aortic valve replacement (TAVR). Multidimensional CT (MDCT) is the main imaging mortality for the diagnosis of SLT but it enhances the risk of contrast-induced nephropathy. Our study aimed to use an innovative wearable acoustic cardiography (ACG) device to diagnose SLT as an alternative option. Methods This prospective cohort study consecutively enrolled patients with severe symptomatic aortic stenosis who underwent successful TAVR. We collected and analysed clinical data including ACG measurements and imaging results. Discrimination capability analysis (ie, area under the curve (AUC), sensitivity, specificity) of a composite feature from ACG readings in predicting SLT during follow-up was performed. Based on the severity of SLT, patients were categorised into three groups: Group 1 (no SLT), Group 2 (mild SLT) and Group 3 (moderate-to-severe SLT). Results 116 patients consented and enrolled in the study. At the 1-month follow-up, MDCT revealed a 25% prevalence of SLT with 11.2% classified as moderate-to-severe. ACG analysis revealed distinctive patterns of early systolic, baseless and high-energy murmurs exclusively in patients in Group 3 but not in group 2. The diagnostic performance of ACG for moderate-to-severe SLT showed a sensitivity of 84.62%, specificity of 91.26% and AUC of 0.920 (95% CI: 0.855 to 0.962, pConclusion ACG can be considered as an effective tool to assist in the diagnosis of SLT based on deterioration of transvalvular haemodynamics post-TAVR. Further studies are required to confirm its utility as a valuable non-invasive diagnostic and monitoring tool. Trial registration number ChiCTR2300072300.
- Open Access
- 6 September 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (18) , 2868
Arrhythmic Mitral Valve Prolapse: A Comprehensive Review
Mitral valve prolapse (MVP) is a prevalent cardiac disorder that impacts approximately 2% to 3% of the overall population. While most patients experience a benign clinical course, there is evidence suggesting that a subgroup of MVP patients face an increased risk of sudden cardiac death (SCD). Although a conclusive causal link between MVP and SCD remains to be firmly established, various factors have been associated with arrhythmic mitral valve prolapse (AMVP). This study aims to provide a comprehensive review encompassing the historical background, epidemiology, pathology, clinical manifestations, electrocardiogram (ECG) findings, and treatment of AMVP patients. A key focus is on utilizing multimodal imaging techniques to accurately diagnose AMVP and to highlight the role of mitral annular disjunction (MAD) in AMVP.
- 6 September 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (18) , 2868
Open AccessArrhythmic Mitral Valve Prolapse: A Comprehensive Review
Mitral valve prolapse (MVP) is a prevalent cardiac disorder that impacts approximately 2% to 3% of the overall population. While most patients experience a benign clinical course, there is evidence suggesting that a subgroup of MVP patients face an increased risk of sudden cardiac death (SCD). Although a conclusive causal link between MVP and SCD remains to be firmly established, various factors have been associated with arrhythmic mitral valve prolapse (AMVP). This study aims to provide a comprehensive review encompassing the historical background, epidemiology, pathology, clinical manifestations, electrocardiogram (ECG) findings, and treatment of AMVP patients. A key focus is on utilizing multimodal imaging techniques to accurately diagnose AMVP and to highlight the role of mitral annular disjunction (MAD) in AMVP.
- 2 December 2022
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 39 (4) , 697-706
Transthoracic echocardiographic assessment of cardiac valves in patients with Behçet’s disease
The main objectives of the current study are to investigate valvular involvement in patients with cardiac Behçet’s disease (BD) and find out the risk factors of valvular involvement in cardiac BD. We retrospectively assessed the clinical and echocardiographic data in the medical records of 121 patients with BD admitted to Beijing Anzhen Hospital from January 2015 to January 2022. We evaluated the valvular structure and function mainly by echocardiography. A total of 77 BD patients (77/121, 63.64%) had cardiac valvular involvement. Valvular lesions occurred more frequently in males (p = 0.022). Aortic regurgitation (AR) (62/77, 80.52%) was the most common finding and severe AR occupied 80.65% (50/62). The most common manifestations of BD patients with severe AR was aortic valve prolapse (25/50, 50%), followed by echo-free spaces within the aortic annulus (11/50, 22%), vegetation-like lesions (10/50, 20%), and aortic root aneurysm (10/50, 20%). The incidence of paravalvular leaks (PVL) in BD patients was 14.29% (7/49). The diameter of the sinus of Valsalva and proximal ascending aorta, and total cholesterol (TCHO) were the independent risk factors of moderate-severe aortic valvular regurgitation (p < 0.01). Left ventricular end-diastolic dimension (LVEDD), left ventricular ejection fraction (LVEF) and brain natriuretic peptide (BNP) were significantly associated with moderate-severe mitral valvular regurgitation (p < 0.01). The most common valvular abnormality in BD is AR. Echocardiography has great value in the comprehensive evaluation and accurate diagnosis of valvular involvement in BD patients.
- 2 December 2022
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 39 (4) , 697-706
Transthoracic echocardiographic assessment of cardiac valves in patients with Behçet’s disease
The main objectives of the current study are to investigate valvular involvement in patients with cardiac Behçet’s disease (BD) and find out the risk factors of valvular involvement in cardiac BD. We retrospectively assessed the clinical and echocardiographic data in the medical records of 121 patients with BD admitted to Beijing Anzhen Hospital from January 2015 to January 2022. We evaluated the valvular structure and function mainly by echocardiography. A total of 77 BD patients (77/121, 63.64%) had cardiac valvular involvement. Valvular lesions occurred more frequently in males (p = 0.022). Aortic regurgitation (AR) (62/77, 80.52%) was the most common finding and severe AR occupied 80.65% (50/62). The most common manifestations of BD patients with severe AR was aortic valve prolapse (25/50, 50%), followed by echo-free spaces within the aortic annulus (11/50, 22%), vegetation-like lesions (10/50, 20%), and aortic root aneurysm (10/50, 20%). The incidence of paravalvular leaks (PVL) in BD patients was 14.29% (7/49). The diameter of the sinus of Valsalva and proximal ascending aorta, and total cholesterol (TCHO) were the independent risk factors of moderate-severe aortic valvular regurgitation (p < 0.01). Left ventricular end-diastolic dimension (LVEDD), left ventricular ejection fraction (LVEF) and brain natriuretic peptide (BNP) were significantly associated with moderate-severe mitral valvular regurgitation (p < 0.01). The most common valvular abnormality in BD is AR. Echocardiography has great value in the comprehensive evaluation and accurate diagnosis of valvular involvement in BD patients.
- Open Access
- 19 September 2022
- Published by Springer Nature in Research Square
Role of Echocardiography in the Assessment of Cardiac Involvement in Takayasu Arteritis
Background: The aim of this study is to investigate echocardiographic features of patients with cardiac involvement and evaluate the value of echocardiography in Takayasu arteritis (TA). Methods:All patients with TA admitted from January 2015 to December 2021 were classified into patients with cardiac involvement (group 1, n=68) and patients without cardiac involvement (group 2, n=59). This retrospective study compared the clinical manifestations and echocardiographic parameters between the two groups and further explored the relationship between pulmonary hypertension (PH) and echocardiographic parameters. Clinical, imaging and laboratory results of the TA patients were obtained from hospital files. Results: In our study, 68 patients (53.54%) had cardiac involvement. Valvular abnormalities were found in 55 (80.88%) patients in group 1, coronary artery abnormalities in 10 (14.71%), myocardial abnormalities in 18 (26.47%) and PH in 11 patients (16.18%), respectively. Compared to group 2, both TA patients in group 1 associated with and without PH presented with the significantly differences of echocardiographic parameters regarding left atrial diameter (LAD), interventricular septum thickness (IVST), left ventricular posterior wall thickness (LVPWT), left ventricular end-diastolic dimension (LVEDD), left ventricular end-systolic dimension (LVESD), left ventricular ejection fraction (LVEF), left ventricular (LV) mass, LV mass/body surface area (BSA), main pulmonary artery diameter (MPAD) (P0.05). Conclusions: Cardiac involvement is not infrequent in TA patients and it should be carefully evaluated. Echocardiography plays a vital role in the assessment of cardiac involvement in TA which is helpful for diagnosis and management of TA.
- 19 September 2022
- Published by Springer Nature in Research Square
Open AccessRole of Echocardiography in the Assessment of Cardiac Involvement in Takayasu Arteritis
Background: The aim of this study is to investigate echocardiographic features of patients with cardiac involvement and evaluate the value of echocardiography in Takayasu arteritis (TA). Methods:All patients with TA admitted from January 2015 to December 2021 were classified into patients with cardiac involvement (group 1, n=68) and patients without cardiac involvement (group 2, n=59). This retrospective study compared the clinical manifestations and echocardiographic parameters between the two groups and further explored the relationship between pulmonary hypertension (PH) and echocardiographic parameters. Clinical, imaging and laboratory results of the TA patients were obtained from hospital files. Results: In our study, 68 patients (53.54%) had cardiac involvement. Valvular abnormalities were found in 55 (80.88%) patients in group 1, coronary artery abnormalities in 10 (14.71%), myocardial abnormalities in 18 (26.47%) and PH in 11 patients (16.18%), respectively. Compared to group 2, both TA patients in group 1 associated with and without PH presented with the significantly differences of echocardiographic parameters regarding left atrial diameter (LAD), interventricular septum thickness (IVST), left ventricular posterior wall thickness (LVPWT), left ventricular end-diastolic dimension (LVEDD), left ventricular end-systolic dimension (LVESD), left ventricular ejection fraction (LVEF), left ventricular (LV) mass, LV mass/body surface area (BSA), main pulmonary artery diameter (MPAD) (P0.05). Conclusions: Cardiac involvement is not infrequent in TA patients and it should be carefully evaluated. Echocardiography plays a vital role in the assessment of cardiac involvement in TA which is helpful for diagnosis and management of TA.
- Open Access
- 14 September 2022
- Published by Springer Nature in Research Square
Cardiac valvular involvement of Behçet’s disease
The main objectives of the current study are to investigate valvular abnormality of Behçet’s disease (BD) patients with valvular involvement and find out the risk factors of valvular involvement in BD. We retrospectively assessed the clinical and echocardiographic data in the medical records of 121 patients with BD admitted to Beijing Anzhen Hospital from January 2015 to January 2022. We evaluated the valvular structure and function mainly by echocardiography. A total of 77 BD patients (77/121, 63.64%) had cardiac valvular involvement. Valvular lesions occurred more frequently in males (p = 0.022). Aortic regurgitation (AR) (62/77, 80.52%) was the most common finding and severe AR occupied 80.65% (50/62). The most common manifestations of BD patients with severe AR was aortic valve prolapse (25/50, 50%), followed by echo-free spaces within the aortic annulus (11/50, 22%), vegetation-like lesions (10/50, 20%), and aortic root aneurysm (10/50, 20%). The incidence of paravalvular leaks (PVL) in BD patients was 14.29% (7/49). The maximal diameter of the sinus of Valsalva and proximal ascending aorta, and total cholesterol (TCHO) were the independent risk factors of moderate-severe aortic valvular regurgitation (p < 0.01). Left ventricular end-diastolic dimension (LVEDD), left ventricular ejection fraction (LVEF) and brain natriuretic peptide (BNP) were significantly associated with moderate-severe mitral valvular regurgitation (p < 0.01). The most common valvular abnormality in BD is AR. Echocardiography has great value in the comprehensive evaluation and accurate diagnosis of valvular involvement in BD patients.
- 14 September 2022
- Published by Springer Nature in Research Square
Open AccessCardiac valvular involvement of Behçet’s disease
The main objectives of the current study are to investigate valvular abnormality of Behçet’s disease (BD) patients with valvular involvement and find out the risk factors of valvular involvement in BD. We retrospectively assessed the clinical and echocardiographic data in the medical records of 121 patients with BD admitted to Beijing Anzhen Hospital from January 2015 to January 2022. We evaluated the valvular structure and function mainly by echocardiography. A total of 77 BD patients (77/121, 63.64%) had cardiac valvular involvement. Valvular lesions occurred more frequently in males (p = 0.022). Aortic regurgitation (AR) (62/77, 80.52%) was the most common finding and severe AR occupied 80.65% (50/62). The most common manifestations of BD patients with severe AR was aortic valve prolapse (25/50, 50%), followed by echo-free spaces within the aortic annulus (11/50, 22%), vegetation-like lesions (10/50, 20%), and aortic root aneurysm (10/50, 20%). The incidence of paravalvular leaks (PVL) in BD patients was 14.29% (7/49). The maximal diameter of the sinus of Valsalva and proximal ascending aorta, and total cholesterol (TCHO) were the independent risk factors of moderate-severe aortic valvular regurgitation (p < 0.01). Left ventricular end-diastolic dimension (LVEDD), left ventricular ejection fraction (LVEF) and brain natriuretic peptide (BNP) were significantly associated with moderate-severe mitral valvular regurgitation (p < 0.01). The most common valvular abnormality in BD is AR. Echocardiography has great value in the comprehensive evaluation and accurate diagnosis of valvular involvement in BD patients.
- Open Access
- 26 May 2022
- Published by Frontiers Media SA in Frontiers in Cardiovascular Medicine
- Vol. 9, 896062
Economic Evaluation of Transcatheter Aortic Valve Replacement Compared to Surgical Aortic Valve Replacement in Chinese Intermediate-Risk Patients
Background: Aortic stenosis (AS) is a severe disease that causes heart failure and sudden death. Transcatheter aortic valve replacement (TAVR) and surgical aortic valve replacement (SAVR) are both recommended for patients with intermediate surgical risk, but the cost-effectiveness of TAVR compared to SAVR in China has not been investigated.Methods: A combined decision tree and Markov model were conducted to compare the cost-effectiveness of TAVR versus SAVR with a 5-year simulation. The primary outcome was the incremental cost-effectiveness ratio (ICER), a ratio of incremental costs to incremental quality-adjusted life-year (QALY). One-way sensitive analysis and probabilistic sensitivity analysis (PSA) were conducted to test the robustness of the model.Results: After a simulation of 5 years, the costs of TAVR and SAVR were 54,573 and 35,002 USD, respectively, and the corresponding effectiveness was 2.826 versus 2.712 QALY, respectively. The ICER for the TAVR versus SAVR comparison was 170,056 USD/QALY, which was three times higher than the per capita gross domestic product (GDP) in China. One-way sensitive analysis showed that the cost of the TAVR device impacted the ICER. The TAVR could be cost-effective only in the case where its cost is lowered to 29,766 USD.Conclusion: TAVR is currently not cost-effective in China, but it could be cost-effective with a reduction of costs to 29,766 USD, which is approximately 65% of the current price.
- 26 May 2022
- Published by Frontiers Media SA in Frontiers in Cardiovascular Medicine
- Vol. 9, 896062
Open AccessEconomic Evaluation of Transcatheter Aortic Valve Replacement Compared to Surgical Aortic Valve Replacement in Chinese Intermediate-Risk Patients
Background: Aortic stenosis (AS) is a severe disease that causes heart failure and sudden death. Transcatheter aortic valve replacement (TAVR) and surgical aortic valve replacement (SAVR) are both recommended for patients with intermediate surgical risk, but the cost-effectiveness of TAVR compared to SAVR in China has not been investigated.Methods: A combined decision tree and Markov model were conducted to compare the cost-effectiveness of TAVR versus SAVR with a 5-year simulation. The primary outcome was the incremental cost-effectiveness ratio (ICER), a ratio of incremental costs to incremental quality-adjusted life-year (QALY). One-way sensitive analysis and probabilistic sensitivity analysis (PSA) were conducted to test the robustness of the model.Results: After a simulation of 5 years, the costs of TAVR and SAVR were 54,573 and 35,002 USD, respectively, and the corresponding effectiveness was 2.826 versus 2.712 QALY, respectively. The ICER for the TAVR versus SAVR comparison was 170,056 USD/QALY, which was three times higher than the per capita gross domestic product (GDP) in China. One-way sensitive analysis showed that the cost of the TAVR device impacted the ICER. The TAVR could be cost-effective only in the case where its cost is lowered to 29,766 USD.Conclusion: TAVR is currently not cost-effective in China, but it could be cost-effective with a reduction of costs to 29,766 USD, which is approximately 65% of the current price.