ShiYuan Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
ShiYuan Liu has a total of 47 co-authors. Here are the top co-authors by number of shared publications:
Li Fan
Department of Radiology, Changzheng Hospital, Second Military Medical University, No. 415 Fengyang Road, Shanghai 200003, China
7 shared publicationsYi Xia
Department of Radiology, Changzheng Hospital, Second Military Medical University, No. 415 Fengyang Road, Shanghai 200233, China
5 shared publicationsWenTing Tu
Department of Radiology, Changzheng Hospital, Second Military Medical University, No. 415 Fengyang Road, Shanghai 200233, China
4 shared publicationsQiong Li
Department of Radiology, Changzheng Hospital, Second Military Medical University, No. 415 Fengyang Road, Shanghai 200003, China
3 shared publicationsYu Guan
Department of Radiology, Changzheng Hospital, Second Military Medical University, No. 415 Fengyang Road, Shanghai, 200003, China
3 shared publicationsYun Wang
Department of Radiology, Changzheng Hospital, Second Military Medical University, No. 415 Fengyang Road, Shanghai 200003, China
3 shared publications
Latest Publications
- 1 October 2019
- Published by Elsevier in Academic Radiology
- Vol. 26 (10) , 1283-1291
Lung Cancer Screening with Low-Dose CT: Baseline Screening Results in Shanghai
- 1 October 2019
- Published by Elsevier in Academic Radiology
- Vol. 26 (10) , 1283-1291
Lung Cancer Screening with Low-Dose CT: Baseline Screening Results in Shanghai
- 1 September 2019
- Published by Elsevier in Academic Radiology
- Vol. 26 (9) , 1253-1261
Radiomics Signature: A Biomarker for the Preoperative Distant Metastatic Prediction of Stage I Nonsmall Cell Lung Cancer
- 1 September 2019
- Published by Elsevier in Academic Radiology
- Vol. 26 (9) , 1253-1261
Radiomics Signature: A Biomarker for the Preoperative Distant Metastatic Prediction of Stage I Nonsmall Cell Lung Cancer
- 18 March 2019
- Published by Springer Nature in European Radiology
- Vol. 29 (11) , 6049-6058
Can peritumoral radiomics increase the efficiency of the prediction for lymph node metastasis in clinical stage T1 lung adenocarcinoma on CT?
To evaluate the efficiency of radiomics model on CT images of intratumoral and peritumoral lung parenchyma for preoperative prediction of lymph node (LN) metastasis in clinical stage T1 peripheral lung adenocarcinoma patients.
- 18 March 2019
- Published by Springer Nature in European Radiology
- Vol. 29 (11) , 6049-6058
Can peritumoral radiomics increase the efficiency of the prediction for lymph node metastasis in clinical stage T1 lung adenocarcinoma on CT?
To evaluate the efficiency of radiomics model on CT images of intratumoral and peritumoral lung parenchyma for preoperative prediction of lymph node (LN) metastasis in clinical stage T1 peripheral lung adenocarcinoma patients.
- 28 January 2019
- Published by Springer Nature in European Radiology
- Vol. 29 (8) , 4333-4340
Changes in quantitative parameters of pulmonary nonsolid nodule induced by lung inflation according to paired inspiratory and expiratory computed tomography imaging
Objective To evaluate quantitative parameters of nonsolid nodules on paired inspiratory and expiratory computed tomography (CT) and to examine whether these parameters are sensitive to lung inflation reflected by lung volume. Methods Thirty-three patients with 41 nonsolid nodules were included in this prospective study. Paired inspiratory and low-dose respiratory plain chest CT were performed. The volume and density of nonsolid nodule(s), both lungs, the right and left lung, and five lobes, were analyzed in inspiratory and expiratory CT scans. The ratio of expiratory to inspiratory parameters was calculated and labeled as parameter(E-I)/I. To standardize the changes in nonsolid nodule quantitative parameters, the ratio of nonsolid nodule parameter to lung parameter was also calculated. Quantitative parameters were compared between inspiratory and expiratory CT. Results Nonsolid nodule volumes on expiratory CT were reduced by 19.8% ± 12.9%, while the density was increased by 11.4% ± 8.8%. The volume of nonsolid nodules was significantly greater on inspiratory compared with expiratory CT (p < 0.001). The density of nonsolid nodules was significantly greater on expiratory than inspiratory CT (p < 0.001). The volume(E-I)/I was significantly greater than density(E-I)/I both in nonsolid nodules and lung. The volume(E-I)/I and density(E-I)/I of nonsolid nodules were independent of size. The density(E-I)/I of nonsolid nodule was greater in the lower lobe than that in the upper lobe (p = 0.002). Conclusion Volume changes in nonsolid nodules were more sensitive than density changes in expiratory phase. The density of lower lobe nodules was more susceptible to respiration. Expiratory scanning is not recommended for quantification of nonsolid nodules and/or follow-up. Key Points • The nonsolid nodule volume on expiratory CT was reduced by 19.8% ± 12.9%. • The nonsolid nodule density on expiratory CT was increased by 11.4% ± 8.8%. • The volume (E-I)/I and density (E-I)/I of nonsolid nodules were independent of size.
- 28 January 2019
- Published by Springer Nature in European Radiology
- Vol. 29 (8) , 4333-4340
Changes in quantitative parameters of pulmonary nonsolid nodule induced by lung inflation according to paired inspiratory and expiratory computed tomography imaging
Objective To evaluate quantitative parameters of nonsolid nodules on paired inspiratory and expiratory computed tomography (CT) and to examine whether these parameters are sensitive to lung inflation reflected by lung volume. Methods Thirty-three patients with 41 nonsolid nodules were included in this prospective study. Paired inspiratory and low-dose respiratory plain chest CT were performed. The volume and density of nonsolid nodule(s), both lungs, the right and left lung, and five lobes, were analyzed in inspiratory and expiratory CT scans. The ratio of expiratory to inspiratory parameters was calculated and labeled as parameter(E-I)/I. To standardize the changes in nonsolid nodule quantitative parameters, the ratio of nonsolid nodule parameter to lung parameter was also calculated. Quantitative parameters were compared between inspiratory and expiratory CT. Results Nonsolid nodule volumes on expiratory CT were reduced by 19.8% ± 12.9%, while the density was increased by 11.4% ± 8.8%. The volume of nonsolid nodules was significantly greater on inspiratory compared with expiratory CT (p < 0.001). The density of nonsolid nodules was significantly greater on expiratory than inspiratory CT (p < 0.001). The volume(E-I)/I was significantly greater than density(E-I)/I both in nonsolid nodules and lung. The volume(E-I)/I and density(E-I)/I of nonsolid nodules were independent of size. The density(E-I)/I of nonsolid nodule was greater in the lower lobe than that in the upper lobe (p = 0.002). Conclusion Volume changes in nonsolid nodules were more sensitive than density changes in expiratory phase. The density of lower lobe nodules was more susceptible to respiration. Expiratory scanning is not recommended for quantification of nonsolid nodules and/or follow-up. Key Points • The nonsolid nodule volume on expiratory CT was reduced by 19.8% ± 12.9%. • The nonsolid nodule density on expiratory CT was increased by 11.4% ± 8.8%. • The volume (E-I)/I and density (E-I)/I of nonsolid nodules were independent of size.
- 15 October 2018
- Published by Springer Nature in European Radiology
- Vol. 29 (4) , 1703-1713
The “solid” component within subsolid nodules: imaging definition, display, and correlation with invasiveness of lung adenocarcinoma, a comparison of CT histograms and subjective evaluation
To validate three proposed definitions of the “solid” component of subsolid nodules, as compared to CT histograms and the use of different window settings, for discriminating the invasiveness of adenocarcinomas in a manner that facilitates routine clinical assessment.
- 15 October 2018
- Published by Springer Nature in European Radiology
- Vol. 29 (4) , 1703-1713
The “solid” component within subsolid nodules: imaging definition, display, and correlation with invasiveness of lung adenocarcinoma, a comparison of CT histograms and subjective evaluation
To validate three proposed definitions of the “solid” component of subsolid nodules, as compared to CT histograms and the use of different window settings, for discriminating the invasiveness of adenocarcinomas in a manner that facilitates routine clinical assessment.
- 2 July 2018
- Published by Springer Nature in European Radiology
- Vol. 29 (2) , 889-897
Radiomics signature: a biomarker for the preoperative discrimination of lung invasive adenocarcinoma manifesting as a ground-glass nodule
To identify the radiomics signature allowing preoperative discrimination of lung invasive adenocarcinomas from non-invasive lesions manifesting as ground-glass nodules.
- 2 July 2018
- Published by Springer Nature in European Radiology
- Vol. 29 (2) , 889-897
Radiomics signature: a biomarker for the preoperative discrimination of lung invasive adenocarcinoma manifesting as a ground-glass nodule
To identify the radiomics signature allowing preoperative discrimination of lung invasive adenocarcinomas from non-invasive lesions manifesting as ground-glass nodules.
- 31 July 2013
- Published by Wiley in The Clinical Respiratory Journal
- Vol. 8 (1) , 45-54
Characteristic features of pulmonary function test, CT volume analysis and MR perfusion imaging in COPD patients with different HRCT phenotypes
Introduction: Computed tomography (CT) and magnetic resonance imaging (MRI) can provide detailed anatomic structures and quantitative function information for chronic obstructive pulmonary disease (COPD).Objectives: To prospectively clarify characteristics of pulmonary function test (PFT), CT volume parameters and magnetic resonance (MR) perfusion imaging in COPD patients with different high‐resolution computed tomography (HRCT) phenotypes.Methods: Sixty‐two patients performed PFT, CT and MR perfusion imaging. COPD was classified into three phenotypes according to HRCT quantitative findings: A, E and M phenotype. Total lung volume (TLV), total emphysema volume (TEV) and emphysema index (EI) were quantitated by HRCT. In cases of perfusion defects (PDs), the shape and size were evaluated. The contrast between the normal lung and PDs was quantified by calculating their signal intensity ratio (RSI = SIPD/SInormal). The correlation was performed between PFT, CT and MR perfusion.Results: There were 42 A phenotype, 9 E phenotype and 11 M phenotype. There was significant difference in forced expiratory volume in 1 s (FEV1)/forced vital capacity (FVC) between A and M phenotype (P < 0.05). TEV and EI of A phenotype (0.4 ± 0.4 L and 8.0% ± 4.3%) were lower than those of E (1.0 ± 0.3 L and 18.6% ± 3.2%) or M phenotype (0.9 ± 0.2 L and 17.5% ± 1.7%). MR perfusion images showed circumscribed or diffuse patchy PDs. RSI of A phenotype was higher than that of E phenotype (20.3% ± 8.5% vs 11.8% ± 5.4%; P = 0.006). TEV and EI were moderate negatively correlated with diffusion function parameters. RSI was strongly correlated with FEV1% (A) and FEV1/FVC (M). FEV1/FVC was strongly correlated with TEV or EI (E).Conclusion: There were different features and correlations between PFT, CT volume and MR perfusion in different phenotype, indicating each phenotype may have novel imaging method guiding clinical management.
- 31 July 2013
- Published by Wiley in The Clinical Respiratory Journal
- Vol. 8 (1) , 45-54
Characteristic features of pulmonary function test, CT volume analysis and MR perfusion imaging in COPD patients with different HRCT phenotypes
Introduction: Computed tomography (CT) and magnetic resonance imaging (MRI) can provide detailed anatomic structures and quantitative function information for chronic obstructive pulmonary disease (COPD).Objectives: To prospectively clarify characteristics of pulmonary function test (PFT), CT volume parameters and magnetic resonance (MR) perfusion imaging in COPD patients with different high‐resolution computed tomography (HRCT) phenotypes.Methods: Sixty‐two patients performed PFT, CT and MR perfusion imaging. COPD was classified into three phenotypes according to HRCT quantitative findings: A, E and M phenotype. Total lung volume (TLV), total emphysema volume (TEV) and emphysema index (EI) were quantitated by HRCT. In cases of perfusion defects (PDs), the shape and size were evaluated. The contrast between the normal lung and PDs was quantified by calculating their signal intensity ratio (RSI = SIPD/SInormal). The correlation was performed between PFT, CT and MR perfusion.Results: There were 42 A phenotype, 9 E phenotype and 11 M phenotype. There was significant difference in forced expiratory volume in 1 s (FEV1)/forced vital capacity (FVC) between A and M phenotype (P < 0.05). TEV and EI of A phenotype (0.4 ± 0.4 L and 8.0% ± 4.3%) were lower than those of E (1.0 ± 0.3 L and 18.6% ± 3.2%) or M phenotype (0.9 ± 0.2 L and 17.5% ± 1.7%). MR perfusion images showed circumscribed or diffuse patchy PDs. RSI of A phenotype was higher than that of E phenotype (20.3% ± 8.5% vs 11.8% ± 5.4%; P = 0.006). TEV and EI were moderate negatively correlated with diffusion function parameters. RSI was strongly correlated with FEV1% (A) and FEV1/FVC (M). FEV1/FVC was strongly correlated with TEV or EI (E).Conclusion: There were different features and correlations between PFT, CT volume and MR perfusion in different phenotype, indicating each phenotype may have novel imaging method guiding clinical management.
- 21 December 2012
- Published by Springer Nature in European Radiology
- Vol. 23 (5) , 1234-1241
Capability of differentiating smokers with normal pulmonary function from COPD patients: a comparison of CT pulmonary volume analysis and MR perfusion imaging
- 21 December 2012
- Published by Springer Nature in European Radiology
- Vol. 23 (5) , 1234-1241
Capability of differentiating smokers with normal pulmonary function from COPD patients: a comparison of CT pulmonary volume analysis and MR perfusion imaging
- 1 July 2012
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 85 (1015) , 897-904
Multidetector CT features of pulmonary focal ground-glass opacity: differences between benign and malignant
Objective: To evaluate different features between benign and malignant pulmonary focal ground-glass opacity (fGGO) on multidetector CT (MDCT). Methods: 82 pathologically or clinically confirmed fGGOs were retrospectively analysed with regard to demographic data, lesion size and location, attenuation value and MDCT features including shape, margin, interface, internal characteristics and adjacent structure. Differences between benign and malignant fGGOs were analysed using a χ2 test, Fisher's exact test or Mann–Whitney U-test. Morphological characteristics were analysed by binary logistic regression analysis to estimate the likelihood of malignancy. Results: There were 21 benign and 61 malignant lesions. No statistical differences were found between benign and malignant fGGOs in terms of demographic data, size, location and attenuation value. The frequency of lobulation (p=0.000), spiculation (p=0.008), spine-like process (p=0.004), well-defined but coarse interface (p=0.000), bronchus cut-off (p=0.003), o...
- 1 July 2012
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 85 (1015) , 897-904
Multidetector CT features of pulmonary focal ground-glass opacity: differences between benign and malignant
Objective: To evaluate different features between benign and malignant pulmonary focal ground-glass opacity (fGGO) on multidetector CT (MDCT). Methods: 82 pathologically or clinically confirmed fGGOs were retrospectively analysed with regard to demographic data, lesion size and location, attenuation value and MDCT features including shape, margin, interface, internal characteristics and adjacent structure. Differences between benign and malignant fGGOs were analysed using a χ2 test, Fisher's exact test or Mann–Whitney U-test. Morphological characteristics were analysed by binary logistic regression analysis to estimate the likelihood of malignancy. Results: There were 21 benign and 61 malignant lesions. No statistical differences were found between benign and malignant fGGOs in terms of demographic data, size, location and attenuation value. The frequency of lobulation (p=0.000), spiculation (p=0.008), spine-like process (p=0.004), well-defined but coarse interface (p=0.000), bronchus cut-off (p=0.003), o...
- 22 June 2011
- Published by Wiley in Journal of Medical Imaging and Radiation Oncology
- Vol. 55 (3) , 279-285
Pulmonary malignant focal ground-glass opacity nodules and solid nodules of 3 cm or less: Comparison of multi-detector CT features
Introduction: To evaluate the different multi‐detector computed tomography (MDCT) features between pulmonary malignant focal ground‐glass opacity (fGGO) nodules and solid nodules of 3 cm or less in diameter. Methods: One hundred and five malignant solid nodules and 48 malignant fGGOs confirmed by pathology were retrospectively analysed with regard to the patient's demographic data, nodule size and MDCT features (shape, margin, interface, internal characteristics and adjacent structure). Differences were analysed using the Fisher exact test or Mann–Whitney U‐test. Results: The male to female ratio of patients with malignant solid nodules (60:45) was higher than that with malignant fGGOs (18:30) (P < 0.05). There was no significant difference in either patient's age (P > 0.05) or nodule size (P > 0.05). The frequency of irregular shape (4% vs. 21%), spiculation (57% vs. 40%), vacuole sign (11% vs. 52%) and natural air bronchograms (0% vs. 24%) was significantly different between malignant solid nodules and fGGOs. No differences were found in the frequency of lobulation, cusp angle, spine‐like process, interface and adjacent structure between the two groups (P > 0.05). Conclusion: Malignant fGGOs and solid nodules showed mostly similar MDCT features. For malignant fGGOs, the frequency of irregular shape, vacuole sign and natural air bronchograms was higher than that in solid nodules, but the frequency of spiculation was lower than that in solid nodules.
- 22 June 2011
- Published by Wiley in Journal of Medical Imaging and Radiation Oncology
- Vol. 55 (3) , 279-285
Pulmonary malignant focal ground-glass opacity nodules and solid nodules of 3 cm or less: Comparison of multi-detector CT features
Introduction: To evaluate the different multi‐detector computed tomography (MDCT) features between pulmonary malignant focal ground‐glass opacity (fGGO) nodules and solid nodules of 3 cm or less in diameter. Methods: One hundred and five malignant solid nodules and 48 malignant fGGOs confirmed by pathology were retrospectively analysed with regard to the patient's demographic data, nodule size and MDCT features (shape, margin, interface, internal characteristics and adjacent structure). Differences were analysed using the Fisher exact test or Mann–Whitney U‐test. Results: The male to female ratio of patients with malignant solid nodules (60:45) was higher than that with malignant fGGOs (18:30) (P < 0.05). There was no significant difference in either patient's age (P > 0.05) or nodule size (P > 0.05). The frequency of irregular shape (4% vs. 21%), spiculation (57% vs. 40%), vacuole sign (11% vs. 52%) and natural air bronchograms (0% vs. 24%) was significantly different between malignant solid nodules and fGGOs. No differences were found in the frequency of lobulation, cusp angle, spine‐like process, interface and adjacent structure between the two groups (P > 0.05). Conclusion: Malignant fGGOs and solid nodules showed mostly similar MDCT features. For malignant fGGOs, the frequency of irregular shape, vacuole sign and natural air bronchograms was higher than that in solid nodules, but the frequency of spiculation was lower than that in solid nodules.