Arijitt Borthakur
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Arijitt Borthakur has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Ravinder Reddy
Center for Advanced Metabolic Imaging in Precision Medicine, Department of Radiology, University of Pennsylvania, Philadelphia, PA, United States
9 shared publications Andrew J. Wheaton
Metabolic Magnetic Resonance Research & Computing Center (MMRRCC), Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
3 shared publicationsErik M. Shapiro
Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania
3 shared publicationsJ. Bruce Kneeland
Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania
3 shared publicationsAndrew Wheaton
Department of Radiology, University of Pennsylvania, Philadelphia, PA, USA
2 shared publicationsJohn Q. Trojanowski
Department of Pathology & Lab Medicine, and Penn Memory Center, University of Pennsylvania, Philadelphia, PA
2 shared publications
Latest Publications
- 1 July 2008
- Published by Elsevier in NeuroImage
- Vol. 41 (4) , 1199-1205
T1ρ MRI of Alzheimer's disease
- 1 July 2008
- Published by Elsevier in NeuroImage
- Vol. 41 (4) , 1199-1205
T1ρ MRI of Alzheimer's disease
- 1 June 2007
- Published by Elsevier in Seminars in Spine Surgery
- Vol. 19 (2) , 65-71
Advances in Magnetic Resonance Imaging for the Assessment of Degenerative Disc Disease of the Lumbar Spine
- 1 June 2007
- Published by Elsevier in Seminars in Spine Surgery
- Vol. 19 (2) , 65-71
Advances in Magnetic Resonance Imaging for the Assessment of Degenerative Disc Disease of the Lumbar Spine
- Open Access
- 11 October 2006
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 24 (5) , 1011-1017
In vivo measurement of plaque burden in a mouse model of Alzheimer's disease
Purpose: To demonstrate an MRI method for directly visualizing amyloid‐β (Aβ) plaques in the APP/PS1 transgenic (tg) mouse brain in vivo, and show that T1ρ relaxation rate increases progressively with Alzheimer's disease (AD)‐related pathology in the tg mouse brain.Materials and Methods: We obtained in vivo MR images of a mouse model of AD (APP/PS1) that overexpresses human amyloid precursor protein, and measured T1ρ via quantitative relaxometric maps.Results: A significant decrease in T1ρ was observed in the cortex and hippocampus of 12‐ and 18‐month‐old animals compared to their age‐matched controls. There was also a correlation between changes in T1ρ and the age of the animals.Conclusion: T1ρ relaxometry may be a sensitive method for noninvasively determining AD‐related pathology in APP/PS1 mice. J. Magn. Reson. Imaging 2006.
- 11 October 2006
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 24 (5) , 1011-1017
Open AccessIn vivo measurement of plaque burden in a mouse model of Alzheimer's disease
Purpose: To demonstrate an MRI method for directly visualizing amyloid‐β (Aβ) plaques in the APP/PS1 transgenic (tg) mouse brain in vivo, and show that T1ρ relaxation rate increases progressively with Alzheimer's disease (AD)‐related pathology in the tg mouse brain.Materials and Methods: We obtained in vivo MR images of a mouse model of AD (APP/PS1) that overexpresses human amyloid precursor protein, and measured T1ρ via quantitative relaxometric maps.Results: A significant decrease in T1ρ was observed in the cortex and hippocampus of 12‐ and 18‐month‐old animals compared to their age‐matched controls. There was also a correlation between changes in T1ρ and the age of the animals.Conclusion: T1ρ relaxometry may be a sensitive method for noninvasively determining AD‐related pathology in APP/PS1 mice. J. Magn. Reson. Imaging 2006.
- Open Access
- 7 March 2006
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 23 (4) , 591-596
A pulse sequence for rapid in vivo spin-locked MRI
- 7 March 2006
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 23 (4) , 591-596
Open AccessA pulse sequence for rapid in vivo spin-locked MRI
- 1 April 2004
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 167 (2) , 306-316
T1ρ-weighted MRI using a surface coil to transmit spin-lock pulses
- 1 April 2004
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 167 (2) , 306-316
T1ρ-weighted MRI using a surface coil to transmit spin-lock pulses
- Open Access
- 29 March 2004
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 19 (4) , 403-409
In vivo measurement of T1ρ dispersion in the human brain at 1.5 tesla
Purpose: To measure T1ρ relaxation times and T1ρ dispersion in the human brain in vivo.Materials and Methods: Magnetic resonance imaging (MRI) was performed on a 1.5‐T GE Signa clinical scanner using the standard GE head coil. A fast spin‐echo (FSE)‐based T1ρ‐weighted MR pulse sequence was employed to obtain images from five healthy male volunteers. Optimal imaging parameters were determined while considering both the objective of the study and the guarantee that radio‐frequency (RF) power deposition during MR did not exceed Food and Drug Administration (FDA)‐mandated safety levels.Results: T1ρ‐weighted MR images showed excellent contrast between different brain tissues. These images were less blurred than corresponding T2‐weighted images obtained with similar contrast, especially in regions between brain parenchyma and cerebrospinal fluid (CSF). Average T1ρ values for white matter (WM), gray matter (GM), and CSF were 85 ± 3, 99 ± 1, and 637 ± 78 msec, respectively, at a spin‐locking field of 500 Hz. T1ρ is 30% higher in the parenchyma and 78% higher in CSF compared to the corresponding T2 values. T1ρ dispersion was observed between spin‐locking frequencies 0 and 500 Hz.Conclusion: T1ρ‐weighted MRI provides images of the brain with superb contrast and detail. T1ρ values measured in the different brain tissues will serve as useful baseline values for analysis of T1ρ changes associated with pathology. J. Magn. Reson. Imaging 2004;19:403–409.
- 29 March 2004
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 19 (4) , 403-409
Open AccessIn vivo measurement of T1ρ dispersion in the human brain at 1.5 tesla
Purpose: To measure T1ρ relaxation times and T1ρ dispersion in the human brain in vivo.Materials and Methods: Magnetic resonance imaging (MRI) was performed on a 1.5‐T GE Signa clinical scanner using the standard GE head coil. A fast spin‐echo (FSE)‐based T1ρ‐weighted MR pulse sequence was employed to obtain images from five healthy male volunteers. Optimal imaging parameters were determined while considering both the objective of the study and the guarantee that radio‐frequency (RF) power deposition during MR did not exceed Food and Drug Administration (FDA)‐mandated safety levels.Results: T1ρ‐weighted MR images showed excellent contrast between different brain tissues. These images were less blurred than corresponding T2‐weighted images obtained with similar contrast, especially in regions between brain parenchyma and cerebrospinal fluid (CSF). Average T1ρ values for white matter (WM), gray matter (GM), and CSF were 85 ± 3, 99 ± 1, and 637 ± 78 msec, respectively, at a spin‐locking field of 500 Hz. T1ρ is 30% higher in the parenchyma and 78% higher in CSF compared to the corresponding T2 values. T1ρ dispersion was observed between spin‐locking frequencies 0 and 500 Hz.Conclusion: T1ρ‐weighted MRI provides images of the brain with superb contrast and detail. T1ρ values measured in the different brain tissues will serve as useful baseline values for analysis of T1ρ changes associated with pathology. J. Magn. Reson. Imaging 2004;19:403–409.
- Open Access
- 19 May 2003
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 17 (6) , 730-736
Three‐dimensional T1ρ‐weighted MRI at 1.5 Tesla
Purpose: To design and implement a magnetic resonance imaging (MRI) pulse sequence capable of performing three‐dimensional T1ρ‐weighted MRI on a 1.5‐T clinical scanner, and determine the optimal sequence parameters, both theoretically and experimentally, so that the energy deposition by the radiofrequency pulses in the sequence, measured as the specific absorption rate (SAR), does not exceed safety guidelines for imaging human subjects.Materials and Methods: A three‐pulse cluster was pre‐encoded to a three‐dimensional gradient‐echo imaging sequence to create a three‐dimensional, T1ρ‐weighted MRI pulse sequence. Imaging experiments were performed on a GE clinical scanner with a custom‐built knee‐coil. We validated the performance of this sequence by imaging articular cartilage of a bovine patella and comparing T1ρ values measured by this sequence to those obtained with a previously tested two‐dimensional imaging sequence. Using a previously developed model for SAR calculation, the imaging parameters were adjusted such that the energy deposition by the radiofrequency pulses in the sequence did not exceed safety guidelines for imaging human subjects. The actual temperature increase due to the sequence was measured in a phantom by a MRI‐based temperature mapping technique. Following these experiments, the performance of this sequence was demonstrated in vivo by obtaining T1ρ‐weighted images of the knee joint of a healthy individual.Results: Calculated T1ρ of articular cartilage in the specimen was similar for both and three‐dimensional and two‐dimensional methods (84 ± 2 msec and 80 ± 3 msec, respectively). The temperature increase in the phantom resulting from the sequence was 0.015°C, which is well below the established safety guidelines. Images of the human knee joint in vivo demonstrate a clear delineation of cartilage from surrounding tissues.Conclusion: We developed and implemented a three‐dimensional T1ρ‐weighted pulse sequence on a 1.5‐T clinical scanner. J. Magn. Reson. Imaging 2003;17:730–736.
- 19 May 2003
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 17 (6) , 730-736
Open AccessThree‐dimensional T1ρ‐weighted MRI at 1.5 Tesla
Purpose: To design and implement a magnetic resonance imaging (MRI) pulse sequence capable of performing three‐dimensional T1ρ‐weighted MRI on a 1.5‐T clinical scanner, and determine the optimal sequence parameters, both theoretically and experimentally, so that the energy deposition by the radiofrequency pulses in the sequence, measured as the specific absorption rate (SAR), does not exceed safety guidelines for imaging human subjects.Materials and Methods: A three‐pulse cluster was pre‐encoded to a three‐dimensional gradient‐echo imaging sequence to create a three‐dimensional, T1ρ‐weighted MRI pulse sequence. Imaging experiments were performed on a GE clinical scanner with a custom‐built knee‐coil. We validated the performance of this sequence by imaging articular cartilage of a bovine patella and comparing T1ρ values measured by this sequence to those obtained with a previously tested two‐dimensional imaging sequence. Using a previously developed model for SAR calculation, the imaging parameters were adjusted such that the energy deposition by the radiofrequency pulses in the sequence did not exceed safety guidelines for imaging human subjects. The actual temperature increase due to the sequence was measured in a phantom by a MRI‐based temperature mapping technique. Following these experiments, the performance of this sequence was demonstrated in vivo by obtaining T1ρ‐weighted images of the knee joint of a healthy individual.Results: Calculated T1ρ of articular cartilage in the specimen was similar for both and three‐dimensional and two‐dimensional methods (84 ± 2 msec and 80 ± 3 msec, respectively). The temperature increase in the phantom resulting from the sequence was 0.015°C, which is well below the established safety guidelines. Images of the human knee joint in vivo demonstrate a clear delineation of cartilage from surrounding tissues.Conclusion: We developed and implemented a three‐dimensional T1ρ‐weighted pulse sequence on a 1.5‐T clinical scanner. J. Magn. Reson. Imaging 2003;17:730–736.
- 1 August 2002
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 224 (2) , 598-602
Quantifying Sodium in the Human Wrist in Vivo by Using MR Imaging
The authors quantified sodium content in the wrist joints of six healthy volunteers with no known history of arthritis or pain. Average sodium concentrations ranged from 115 to 150 mmol/L in noncartilaginous regions and from 200 to 210 mmol/L in cartilaginous regions. The feasibility of quantifying sodium in vivo was demonstrated. This method has potential applications in monitoring the integrity of cartilaginous tissue in vivo.
- 1 August 2002
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 224 (2) , 598-602
Quantifying Sodium in the Human Wrist in Vivo by Using MR Imaging
The authors quantified sodium content in the wrist joints of six healthy volunteers with no known history of arthritis or pain. Average sodium concentrations ranged from 115 to 150 mmol/L in noncartilaginous regions and from 200 to 210 mmol/L in cartilaginous regions. The feasibility of quantifying sodium in vivo was demonstrated. This method has potential applications in monitoring the integrity of cartilaginous tissue in vivo.
- Open Access
- 28 February 2002
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 15 (3) , 315-323
Effect of IL‐1β‐induced macromolecular depletion on residual quadrupolar interaction in articular cartilage
Purpose: Sodium multiple‐quantum filtered (MQF) NMR spectroscopy may potentially be used to measure proteoglycan (PG) depletion in cartilage caused by osteoarthritis (OA). The purpose of this work was to quantify the effect of interleukin‐1 (IL‐1β)‐induced macromolecule depletion on the residual quadrupolar interaction (RQI) of sodium in bovine cartilage plugs.Materials and Methods: Fifteen 8‐mm‐diameter cartilage plug specimens were cored from the articular surface of fresh bovine patellae. All plugs were kept in culture media and nine of the plugs were subjected to interleukin‐1 (IL‐1β)‐induced degeneration of cartilage for 4, 6, and 7 days. Sodium NMR spectra were obtained from each sample with a 1‐cm‐diameter solenoid coil in a 2T whole‐body magnet interfaced to a custom‐built spectrometer. We employed a previously described theoretical model to analyze triple‐quantum filtered (TQF) and double‐quantum filtered magic angle (DQFMA) spectra obtained from normal cartilage and cartilage treated with IL‐1β. The model assumes a static Gaussian distribution of the RQI frequency, ωQ, in the sample. TQF and DQFMA spectra from each sample were fitted with the appropriate signal expressions to determine σ (the root mean square (RMS) ωQ), T2f, and T2s. An inversion‐recovery sequence was used to determine T1 of each plug. A spectrophotometric assay was used to determine the amount of PG depleted from each plug. Histology was performed to visualize the PG loss in cartilage plugs. We defined σ as the measure of changes in macroscopic order in the tissue.Results: Simulated spectra from the theoretical model were in excellent agreement with the experimental data. We were able to determine the relaxation times as well as σ of each specimen from their corresponding fits. T2f ranged between 2.26–3.50 msec, decreasing with increased PG loss. Over the range of PG depletion investigated, T2s increased from 12.3 msec to 14.9 msec, and T1 increased from 16 msec to 21 msec, while σ decreased from 180 Hz to 120 Hz. The order of macromolecules in the cartilage tissue decreased substantially with PG loss. Histology sections clearly showed qualitative visualization of the PG loss in cartilage following treatment with IL‐1β.Conclusion: We demonstrated that IL‐β‐induced macromolecule depletion in cartilage not only changes the relaxation characteristics of sodium but also changes RQI of the tissue. Using MQF sodium spectroscopy we quantified the changes in σ and showed that loss of macromolecules reduces the degree of order in the tissue. J. Magn. Reson. Imaging 2002;15:315–323.
- 28 February 2002
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 15 (3) , 315-323
Open AccessEffect of IL‐1β‐induced macromolecular depletion on residual quadrupolar interaction in articular cartilage
Purpose: Sodium multiple‐quantum filtered (MQF) NMR spectroscopy may potentially be used to measure proteoglycan (PG) depletion in cartilage caused by osteoarthritis (OA). The purpose of this work was to quantify the effect of interleukin‐1 (IL‐1β)‐induced macromolecule depletion on the residual quadrupolar interaction (RQI) of sodium in bovine cartilage plugs.Materials and Methods: Fifteen 8‐mm‐diameter cartilage plug specimens were cored from the articular surface of fresh bovine patellae. All plugs were kept in culture media and nine of the plugs were subjected to interleukin‐1 (IL‐1β)‐induced degeneration of cartilage for 4, 6, and 7 days. Sodium NMR spectra were obtained from each sample with a 1‐cm‐diameter solenoid coil in a 2T whole‐body magnet interfaced to a custom‐built spectrometer. We employed a previously described theoretical model to analyze triple‐quantum filtered (TQF) and double‐quantum filtered magic angle (DQFMA) spectra obtained from normal cartilage and cartilage treated with IL‐1β. The model assumes a static Gaussian distribution of the RQI frequency, ωQ, in the sample. TQF and DQFMA spectra from each sample were fitted with the appropriate signal expressions to determine σ (the root mean square (RMS) ωQ), T2f, and T2s. An inversion‐recovery sequence was used to determine T1 of each plug. A spectrophotometric assay was used to determine the amount of PG depleted from each plug. Histology was performed to visualize the PG loss in cartilage plugs. We defined σ as the measure of changes in macroscopic order in the tissue.Results: Simulated spectra from the theoretical model were in excellent agreement with the experimental data. We were able to determine the relaxation times as well as σ of each specimen from their corresponding fits. T2f ranged between 2.26–3.50 msec, decreasing with increased PG loss. Over the range of PG depletion investigated, T2s increased from 12.3 msec to 14.9 msec, and T1 increased from 16 msec to 21 msec, while σ decreased from 180 Hz to 120 Hz. The order of macromolecules in the cartilage tissue decreased substantially with PG loss. Histology sections clearly showed qualitative visualization of the PG loss in cartilage following treatment with IL‐1β.Conclusion: We demonstrated that IL‐β‐induced macromolecule depletion in cartilage not only changes the relaxation characteristics of sodium but also changes RQI of the tissue. Using MQF sodium spectroscopy we quantified the changes in σ and showed that loss of macromolecules reduces the degree of order in the tissue. J. Magn. Reson. Imaging 2002;15:315–323.
- Open Access
- 1 July 2000
- Published by Elsevier in Osteoarthritis and Cartilage
- Vol. 8 (4) , 288-293
Sensitivity of MRI to proteoglycan depletion in cartilage: comparison of sodium and proton MRI
- 1 July 2000
- Published by Elsevier in Osteoarthritis and Cartilage
- Vol. 8 (4) , 288-293
Open AccessSensitivity of MRI to proteoglycan depletion in cartilage: comparison of sodium and proton MRI