Donghoon Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Donghoon Lee has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Adam D. Maxwell
Department of Urology, University of Washington School of Medicine, Seattle, Washington
1 shared publication Bryan W. Cunitz
University of Washington Applied Physics Lab , Center for Industrial and Medical Ultrasound, Seattle, Washington
1 shared publication- Cynthia D. Johnson
Department of Anatomy and Cell Biology, Indiana University , Indianapolis, Indiana
1 shared publication - David J. Marcinek
Department of Radiology University of Washington Seattle Washington USA
1 shared publication Eric Shankland
Department of Radiology, University of Washington, Seattle, Washington, USA
1 shared publication- Jonathan D. Harper
Department of Urology, University of Washington School of Medicine, Seattle, Washington
1 shared publication
Latest Publications
- 1 August 2017
- Published by SAGE Publications in Journal of Endourology
- Vol. 31 (8) , 786-792
Detection and Evaluation of Renal Injury in Burst Wave Lithotripsy Using Ultrasound and Magnetic Resonance Imaging
Purpose: Burst wave lithotripsy (BWL) is a transcutaneous technique with potential to safely and effectively fragment renal stones. Preclinical investigations of BWL require the assessment of potential renal injury. This study evaluates the capabilities of real-time ultrasound and magnetic resonance imaging (MRI) to detect and evaluate BWL injury that was induced in porcine kidneys. Materials and methods: Ten kidneys from five female farm pigs were treated with either a 170 kHz or 335 kHz BWL transducer using variable treatment parameters and monitored in real time with ultrasound. Eight kidneys were perfusion fixed and scanned with a 3-Tesla MRI scanner (T1-weighted, T2-weighted, and susceptibility-weighted imaging), followed by processing via an established histomorphometric technique for injury quantification. In addition, two kidneys were separately evaluated for histologic characterization of injury quality. Results: Observed B-mode hyperechoes on ultrasound consistent with cavitation predicted the presence of BWL-induced renal injury with a sensitivity and specificity of 100% in comparison to the histomorphometric technique. Similarly, MRI detected renal injury with a sensitivity of 90% and specificity of 100% and was able to identify the scale of lesion volumes. The injuries purposefully generated with BWL were histologically similar to those formed by shock wave lithotripsy. Conclusions: BWL-induced renal injury can be detected with a high degree of sensitivity and specificity by real-time ultrasound and post-treatment ex vivo MRI. No injury occurred in this study without cavitation detected on ultrasound. Such capabilities for injury detection and lesion volume quantification on MRI can be used for preclinical testing of BWL.
- 1 August 2017
- Published by SAGE Publications in Journal of Endourology
- Vol. 31 (8) , 786-792
Detection and Evaluation of Renal Injury in Burst Wave Lithotripsy Using Ultrasound and Magnetic Resonance Imaging
Purpose: Burst wave lithotripsy (BWL) is a transcutaneous technique with potential to safely and effectively fragment renal stones. Preclinical investigations of BWL require the assessment of potential renal injury. This study evaluates the capabilities of real-time ultrasound and magnetic resonance imaging (MRI) to detect and evaluate BWL injury that was induced in porcine kidneys. Materials and methods: Ten kidneys from five female farm pigs were treated with either a 170 kHz or 335 kHz BWL transducer using variable treatment parameters and monitored in real time with ultrasound. Eight kidneys were perfusion fixed and scanned with a 3-Tesla MRI scanner (T1-weighted, T2-weighted, and susceptibility-weighted imaging), followed by processing via an established histomorphometric technique for injury quantification. In addition, two kidneys were separately evaluated for histologic characterization of injury quality. Results: Observed B-mode hyperechoes on ultrasound consistent with cavitation predicted the presence of BWL-induced renal injury with a sensitivity and specificity of 100% in comparison to the histomorphometric technique. Similarly, MRI detected renal injury with a sensitivity of 90% and specificity of 100% and was able to identify the scale of lesion volumes. The injuries purposefully generated with BWL were histologically similar to those formed by shock wave lithotripsy. Conclusions: BWL-induced renal injury can be detected with a high degree of sensitivity and specificity by real-time ultrasound and post-treatment ex vivo MRI. No injury occurred in this study without cavitation detected on ultrasound. Such capabilities for injury detection and lesion volume quantification on MRI can be used for preclinical testing of BWL.
- Open Access
- 25 February 2010
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 63 (3) , 570-573
Quantitative 19 F imaging using inductively coupled reference signal injection
This report describes recent efforts on our continuous development of a synthetic signal injection method for quantification of metabolite content in MR spectroscopy and MRI. Previous work showed that conversion of spectral peaks to quantitative units of metabolite content could be achieved with a calibrated synthetic free induction decay generated by an inductively coupled injection coil. This work demonstrates that calibrated synthetic voxels, injected in the same manner, can be used to quantify metabolite content in real 19F image voxels. Images of vials containing different concentrations of sodium fluoride (NaF) were converted to units of moles by reference to precalibrated synthetically injected voxels. Additional images of vials containing variable sodium chloride (NaCl) demonstrate that the quantification process is robust and immune to changes in coil loading conditions. Magn Reson Med 63:570–573, 2010.
- 25 February 2010
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 63 (3) , 570-573
Open AccessQuantitative 19 F imaging using inductively coupled reference signal injection
This report describes recent efforts on our continuous development of a synthetic signal injection method for quantification of metabolite content in MR spectroscopy and MRI. Previous work showed that conversion of spectral peaks to quantitative units of metabolite content could be achieved with a calibrated synthetic free induction decay generated by an inductively coupled injection coil. This work demonstrates that calibrated synthetic voxels, injected in the same manner, can be used to quantify metabolite content in real 19F image voxels. Images of vials containing different concentrations of sodium fluoride (NaF) were converted to units of moles by reference to precalibrated synthetically injected voxels. Additional images of vials containing variable sodium chloride (NaCl) demonstrate that the quantification process is robust and immune to changes in coil loading conditions. Magn Reson Med 63:570–573, 2010.
- 20 October 2009
- Published by MyJove Corporation in Journal of Visualized Experiments
- No. 32,p. e1592
Noninvasive In Vivo Small Animal MRI and MRS: Basic Experimental Procedures
Small animal Magnetic Resonance (MR) research has emerged as an important element of modern biomedical research due to its non-invasive nature and the richness of biological information it provides. MR does not require any ionizing radiation and can noninvasively provide higher resolution and better signal-to-noise ratio in comparison to other tomographic or spectroscopic modalities. In this protocol, we will focus on small animal MR imaging and MR spectroscopy (MRI/MRS) to noninvasively acquire relaxation weighted 1H images of mouse and to obtain 31P spectra of mouse muscle. This work does not attempt to cover every aspect of small animal MRI/MRS but rather introduces basic procedures of mouse MRI/MRS experiments. The main goal of this work is to inform researchers of the basic procedures for in vivo MR experiments on small animals. The goal is to provide a better understanding of basic experimental procedures to allow researchers new to the MR field to better plan for non-MR components of their studies so that both MR and non-MR procedures are seamlessly integrated.
- 20 October 2009
- Published by MyJove Corporation in Journal of Visualized Experiments
- No. 32,p. e1592
Noninvasive In Vivo Small Animal MRI and MRS: Basic Experimental Procedures
Small animal Magnetic Resonance (MR) research has emerged as an important element of modern biomedical research due to its non-invasive nature and the richness of biological information it provides. MR does not require any ionizing radiation and can noninvasively provide higher resolution and better signal-to-noise ratio in comparison to other tomographic or spectroscopic modalities. In this protocol, we will focus on small animal MR imaging and MR spectroscopy (MRI/MRS) to noninvasively acquire relaxation weighted 1H images of mouse and to obtain 31P spectra of mouse muscle. This work does not attempt to cover every aspect of small animal MRI/MRS but rather introduces basic procedures of mouse MRI/MRS experiments. The main goal of this work is to inform researchers of the basic procedures for in vivo MR experiments on small animals. The goal is to provide a better understanding of basic experimental procedures to allow researchers new to the MR field to better plan for non-MR components of their studies so that both MR and non-MR procedures are seamlessly integrated.