Narmane Fodil
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Narmane Fodil has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
Mohamed Chemrouk
University of Sciences and Technology Houari Boumediene
3 shared publicationsAmina Ammar
Université de La Rochelle. 23 avenue Albert Einstein, BP 33060 - 17031 La Rochelle, France
1 shared publication- Mohamed Chemrouk
Faculty of Civil Engineering, University of Sciences and Technology Houari Boumediene, Algiers, Algeria
1 shared publication
Latest Publications
- Open Access
- 5 November 2025
- Published by Polish Mineral Engineering Society in Inżynieria Mineralna
- Vol. 2 (2)
Assessing Concrete Strength: Insights from Schmidt Rebound Hammer and Ultrasonic Pulse Velocity Techniques
Concrete strength assessment is pivotal in ensuring the structural integrity and longevity of various constructions. Non - destructive testing (NDT) methods have emerged as indispensable tools for predicting concrete strength in situ, facilitating timely interventions and quality assurance protocols. Among these methods, the Schmidt rebound hammer (RH) and ultrasonic pulse velocity (UPV) techniques have gained prominence due to their simplicity, cost - effectiveness, and on - site applicability. This study delves into the relevance and efficacy of RH and UPV techniques for predicting concrete strength, focusing on the development of mathematical correlation models between NDT parameters and compressive strength. The research involves conducting comprehensive experimental investigations on a diverse range of concrete specimens encompassing different mix designs, strength ranges, and ages. Compressive strength, the gold standard for concrete strength determination, was evaluated through destructive testing methods. Concurrently, non - destructive assessments employing RH and UPV were performed on the same specimens. The rebound values from Schmidt Rebound Hammer test and the velocity of ultrasonic pulses were correlated with compressive strengths to establish predictive models. Uni - parametric (RH - Strength and UPV - Strength) correlation models, as well as combined models, were developed to explore the relationship between NDT parameters and concrete compressive strength. In evaluating concrete strength using the Schmidt rebound hammer test, it was observed that this surface test exhibited less sensitivity to variations in concrete mix design within the same strength range. Instead, its sensitivity primarily stemmed from variations in concrete strength, attributed partly to the density of the cement paste at the surface. Conversely, the Ultrasonic Pulse Velocity test emerged as more relevant for assessing concrete strength, given its ability to investigate concrete depth. However, it displayed lower sensitivity to variations in concrete mix design when dealing with high - strength concretes. Despite these nuances, the proposed correlation models demonstrated reliability and accuracy, evident from the coefficients of correlation obtained. Furthermore, the utilization of combined models facilitated an improvement in prediction accuracy compared to uni - parametric models alone. Notably, it was observed that concrete mix design and the age of concrete exerted significant influence as factors diminishing the precision of concrete strength prediction using non - destructive testing (NDT) methods. These findings underscore the importance of considering such influencing factors and refining model calibration processes to further improve the reliability of NDT - based concrete strength assessments. RH and UPV techniques offer valuable insights into concrete strength prediction, aiding rapid on - site assessments and quality control during construction projects. While both methods present strengths and limitations, integrating them alongside conventional testing approaches enhances the reliability and efficiency of concrete strength evaluation. The development of correlation models facilitates quantitative predictions of concrete strength based on NDT parameters, advancing the state - of - the - art in non - destructive evaluation of concrete. Further research focusing on refining testing protocols and calibration techniques is warranted to optimize the accuracy and applicability of these techniques in concrete engineering practices.
- 5 November 2025
- Published by Polish Mineral Engineering Society in Inżynieria Mineralna
- Vol. 2 (2)
Open AccessAssessing Concrete Strength: Insights from Schmidt Rebound Hammer and Ultrasonic Pulse Velocity Techniques
Concrete strength assessment is pivotal in ensuring the structural integrity and longevity of various constructions. Non - destructive testing (NDT) methods have emerged as indispensable tools for predicting concrete strength in situ, facilitating timely interventions and quality assurance protocols. Among these methods, the Schmidt rebound hammer (RH) and ultrasonic pulse velocity (UPV) techniques have gained prominence due to their simplicity, cost - effectiveness, and on - site applicability. This study delves into the relevance and efficacy of RH and UPV techniques for predicting concrete strength, focusing on the development of mathematical correlation models between NDT parameters and compressive strength. The research involves conducting comprehensive experimental investigations on a diverse range of concrete specimens encompassing different mix designs, strength ranges, and ages. Compressive strength, the gold standard for concrete strength determination, was evaluated through destructive testing methods. Concurrently, non - destructive assessments employing RH and UPV were performed on the same specimens. The rebound values from Schmidt Rebound Hammer test and the velocity of ultrasonic pulses were correlated with compressive strengths to establish predictive models. Uni - parametric (RH - Strength and UPV - Strength) correlation models, as well as combined models, were developed to explore the relationship between NDT parameters and concrete compressive strength. In evaluating concrete strength using the Schmidt rebound hammer test, it was observed that this surface test exhibited less sensitivity to variations in concrete mix design within the same strength range. Instead, its sensitivity primarily stemmed from variations in concrete strength, attributed partly to the density of the cement paste at the surface. Conversely, the Ultrasonic Pulse Velocity test emerged as more relevant for assessing concrete strength, given its ability to investigate concrete depth. However, it displayed lower sensitivity to variations in concrete mix design when dealing with high - strength concretes. Despite these nuances, the proposed correlation models demonstrated reliability and accuracy, evident from the coefficients of correlation obtained. Furthermore, the utilization of combined models facilitated an improvement in prediction accuracy compared to uni - parametric models alone. Notably, it was observed that concrete mix design and the age of concrete exerted significant influence as factors diminishing the precision of concrete strength prediction using non - destructive testing (NDT) methods. These findings underscore the importance of considering such influencing factors and refining model calibration processes to further improve the reliability of NDT - based concrete strength assessments. RH and UPV techniques offer valuable insights into concrete strength prediction, aiding rapid on - site assessments and quality control during construction projects. While both methods present strengths and limitations, integrating them alongside conventional testing approaches enhances the reliability and efficiency of concrete strength evaluation. The development of correlation models facilitates quantitative predictions of concrete strength based on NDT parameters, advancing the state - of - the - art in non - destructive evaluation of concrete. Further research focusing on refining testing protocols and calibration techniques is warranted to optimize the accuracy and applicability of these techniques in concrete engineering practices.
- Open Access
- 1 December 2020
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 960 (3) , 032011
Relevance of the Ultrasonic Pulse Velocity Test for Strength Assessment of High Strength Concretes
The present paper addresses the ultrasonic pulse velocity (UPV) as a non-destructive testing device for assessing the compressive strength of high strength concrete using a UPV-strength correlation model. UPV-strength correlation models are developed and used for normal strength concrete assessment; however, questions are raised as to the sensitivity of the ultrasonic pulse velocity test when applied for the strength assessment of denser, higher strength concretes. This study is an appraisal of the relevance of this non-destructive testing device for the high performances concrete strength assessment, aiming for a better knowledge of the applicability of this method as a way to improve the on-site non-destructive strength assessment of the high strength concrete. In the study, a high strength concrete within a specified strength range was targeted. Cylindrical concrete specimens were fabricated, left to harden then subjected to UPV and compressive tests so that a correlation model could be built. The developed model was then used to estimate the strength of a second high strength concrete made with the same type of aggregates. The estimated strength was compared to the real strength of this second HPC in order to assess the reliability of the developed model and hence of the ultrasonic pulse velocity testing. At a second stage, the proposed model was compared to the existing models for high strength concrete assessment, as a procedure to consolidate or negate the observations made in the first part. The results highlight the lack of sensitivity of the UPV method used for the assessment of high strength concrete. Indeed, each high strength concrete considered in this study, including those taken from the literature, varies within a particular strength range while the UPV measurements for all the high strength concretes considered vary narrowly within approximately the same range. This reveals that the UPV non-destructive testing method may not be fully reliable in estimating correctly the strength of a high strength concrete within a range different from that on which the model was built.
- 1 December 2020
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 960 (3) , 032011
Open AccessRelevance of the Ultrasonic Pulse Velocity Test for Strength Assessment of High Strength Concretes
The present paper addresses the ultrasonic pulse velocity (UPV) as a non-destructive testing device for assessing the compressive strength of high strength concrete using a UPV-strength correlation model. UPV-strength correlation models are developed and used for normal strength concrete assessment; however, questions are raised as to the sensitivity of the ultrasonic pulse velocity test when applied for the strength assessment of denser, higher strength concretes. This study is an appraisal of the relevance of this non-destructive testing device for the high performances concrete strength assessment, aiming for a better knowledge of the applicability of this method as a way to improve the on-site non-destructive strength assessment of the high strength concrete. In the study, a high strength concrete within a specified strength range was targeted. Cylindrical concrete specimens were fabricated, left to harden then subjected to UPV and compressive tests so that a correlation model could be built. The developed model was then used to estimate the strength of a second high strength concrete made with the same type of aggregates. The estimated strength was compared to the real strength of this second HPC in order to assess the reliability of the developed model and hence of the ultrasonic pulse velocity testing. At a second stage, the proposed model was compared to the existing models for high strength concrete assessment, as a procedure to consolidate or negate the observations made in the first part. The results highlight the lack of sensitivity of the UPV method used for the assessment of high strength concrete. Indeed, each high strength concrete considered in this study, including those taken from the literature, varies within a particular strength range while the UPV measurements for all the high strength concretes considered vary narrowly within approximately the same range. This reveals that the UPV non-destructive testing method may not be fully reliable in estimating correctly the strength of a high strength concrete within a range different from that on which the model was built.
- Open Access
- 1 September 2019
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 603 (2) , 022049
The influence of steel reinforcement on ultrasonic pulse velocity measurements in concrete of different strength ranges
The present paper reports on the assessment of concrete strength, using non-destructive testing devices. The study focuses on Ultrasonic Pulse Velocity (UPV) as a non-destructive tool for estimating the compressive strength of the concrete in real structures, using a UPV-strength correlation model. The objective is to highlight the steel reinforcement influence on the ultrasound pulse velocity (UPV) measurement as a mean of a non-destructive strength assessment of the concrete. UPV-strength correlation models are built on the basis of laboratory plain concrete specimens tested to destruction. However, the real life structures contain steel reinforcement which interferes with UPV measurements, resulting in the distortion of these measurements, particularly when the reinforcement bars lie in the wave propagation path. Thus, when assessing the quality of the concrete in real structures, it is recommended to avoid reinforcement rebars, which is often difficult, if not impossible to ensure, especially for highly reinforced structural elements. This work proposes an alternative which consists of assessing the influence of steel reinforcement on UPV measurements through a correction factor for UPV readings that will allow the user to take account of the presence of steel reinforcement when assessing the concrete strength of real structures through an ultra-sound pulse velocity testing. In the study, concretes in three different strength ranges were targeted; the aim being to assess the role of the concrete density and the manner with which it interacts with reinforcement rebars when measuring UPV in reinforced concrete structures. The strength ranges considered vary from ordinary, to moderate, to the high strength concrete. Cylindrical moulds made of concrete from three different strength ranges were cast; some of these moulds were reinforced with different longitudinal steel ratios (low, moderate, high) to simulate real practical cases. These concrete moulds were then subjected to UPV tests in the parallel and perpendicular directions to the rebars disposition in order to study the reinforcement influence on UPV from the two directions. A correction factor was then developed to work out of the real ultrasonic pulse velocity of concrete that can be used in the UPV-strength correlation model to determine the compressive strength. For the three concrete strength ranges considered in this study, the presence of steel reinforcement was found to affect the UPV measurements. The results show also that the effect of steel rebar on UPV measurements is more accentuated with a low concrete density, particularly in the presence of a high steel ratio and rebar lying in the parallel direction to the wave propagation path. Indeed, for high performances concrete, which is a higher density concrete, a high steel ratio was found to slightly modify the pulse velocity; moderate and low steel ratios did not affect the pulse velocity. For moderate and normal strength concretes, however, high and moderate steel ratios had noticeable effects on the UPV measurements, especially in the parallel direction; showing that UPV testing is not only affected by the presence of steel reinforcement in concrete, but it is also related to the steel ratio, the rebar disposition, and the concrete density. A correction factor is then necessary for UPV measurements to correlate the strengths of reinforced concrete structures.
- 1 September 2019
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 603 (2) , 022049
Open AccessThe influence of steel reinforcement on ultrasonic pulse velocity measurements in concrete of different strength ranges
The present paper reports on the assessment of concrete strength, using non-destructive testing devices. The study focuses on Ultrasonic Pulse Velocity (UPV) as a non-destructive tool for estimating the compressive strength of the concrete in real structures, using a UPV-strength correlation model. The objective is to highlight the steel reinforcement influence on the ultrasound pulse velocity (UPV) measurement as a mean of a non-destructive strength assessment of the concrete. UPV-strength correlation models are built on the basis of laboratory plain concrete specimens tested to destruction. However, the real life structures contain steel reinforcement which interferes with UPV measurements, resulting in the distortion of these measurements, particularly when the reinforcement bars lie in the wave propagation path. Thus, when assessing the quality of the concrete in real structures, it is recommended to avoid reinforcement rebars, which is often difficult, if not impossible to ensure, especially for highly reinforced structural elements. This work proposes an alternative which consists of assessing the influence of steel reinforcement on UPV measurements through a correction factor for UPV readings that will allow the user to take account of the presence of steel reinforcement when assessing the concrete strength of real structures through an ultra-sound pulse velocity testing. In the study, concretes in three different strength ranges were targeted; the aim being to assess the role of the concrete density and the manner with which it interacts with reinforcement rebars when measuring UPV in reinforced concrete structures. The strength ranges considered vary from ordinary, to moderate, to the high strength concrete. Cylindrical moulds made of concrete from three different strength ranges were cast; some of these moulds were reinforced with different longitudinal steel ratios (low, moderate, high) to simulate real practical cases. These concrete moulds were then subjected to UPV tests in the parallel and perpendicular directions to the rebars disposition in order to study the reinforcement influence on UPV from the two directions. A correction factor was then developed to work out of the real ultrasonic pulse velocity of concrete that can be used in the UPV-strength correlation model to determine the compressive strength. For the three concrete strength ranges considered in this study, the presence of steel reinforcement was found to affect the UPV measurements. The results show also that the effect of steel rebar on UPV measurements is more accentuated with a low concrete density, particularly in the presence of a high steel ratio and rebar lying in the parallel direction to the wave propagation path. Indeed, for high performances concrete, which is a higher density concrete, a high steel ratio was found to slightly modify the pulse velocity; moderate and low steel ratios did not affect the pulse velocity. For moderate and normal strength concretes, however, high and moderate steel ratios had noticeable effects on the UPV measurements, especially in the parallel direction; showing that UPV testing is not only affected by the presence of steel reinforcement in concrete, but it is also related to the steel ratio, the rebar disposition, and the concrete density. A correction factor is then necessary for UPV measurements to correlate the strengths of reinforced concrete structures.