Lorenz Kahl
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Lorenz Kahl has a total of 1 co-authors. Here are the top co-authors by number of shared publications:
- Ulrich G. Hofmann
University of Freiburg
3 shared publications
Latest Publications
- Open Access
Removal of ECG Artifacts Affects Respiratory Muscle Fatigue Detection—A Simulation Study
This work investigates elimination methods for cardiogenic artifacts in respiratory surface electromyographic (sEMG) signals and compares their performance with respect to subsequent fatigue detection with different fatigue algorithms. The analysis is based on artificially constructed test signals featuring a clearly defined expected fatigue level. Test signals are additively constructed with different proportions from sEMG and electrocardiographic (ECG) signals. Cardiogenic artifacts are eliminated by high-pass filtering (HP), template subtraction (TS), a newly introduced two-step approach (TSWD) consisting of template subtraction and a wavelet-based damping step and a pure wavelet-based damping (DSO). Each method is additionally combined with the exclusion of QRS segments (gating). Fatigue is subsequently quantified with mean frequency (MNF), spectral moments ratio of order five (SMR5) and fuzzy approximate entropy (fApEn). Different combinations of artifact elimination methods and fatigue detection algorithms are tested with respect to their ability to deliver invariant results despite increasing ECG contamination. Both DSO and TSWD artifact elimination methods displayed promising results regarding the intermediate, “cleaned” EMG signal. However, only the TSWD method enabled superior results in the subsequent fatigue detection across different levels of artifact contamination and evaluation criteria. SMR5 could be determined as the best fatigue detection algorithm. This study proposes a signal processing chain to determine neuromuscular fatigue despite the presence of cardiogenic artifacts. The results furthermore underline the importance of selecting a combination of algorithms that play well together to remove cardiogenic artifacts and to detect fatigue. This investigation provides guidance for clinical studies to select optimal signal processing to detect fatigue from respiratory sEMG signals.
Open AccessRemoval of ECG Artifacts Affects Respiratory Muscle Fatigue Detection—A Simulation Study
This work investigates elimination methods for cardiogenic artifacts in respiratory surface electromyographic (sEMG) signals and compares their performance with respect to subsequent fatigue detection with different fatigue algorithms. The analysis is based on artificially constructed test signals featuring a clearly defined expected fatigue level. Test signals are additively constructed with different proportions from sEMG and electrocardiographic (ECG) signals. Cardiogenic artifacts are eliminated by high-pass filtering (HP), template subtraction (TS), a newly introduced two-step approach (TSWD) consisting of template subtraction and a wavelet-based damping step and a pure wavelet-based damping (DSO). Each method is additionally combined with the exclusion of QRS segments (gating). Fatigue is subsequently quantified with mean frequency (MNF), spectral moments ratio of order five (SMR5) and fuzzy approximate entropy (fApEn). Different combinations of artifact elimination methods and fatigue detection algorithms are tested with respect to their ability to deliver invariant results despite increasing ECG contamination. Both DSO and TSWD artifact elimination methods displayed promising results regarding the intermediate, “cleaned” EMG signal. However, only the TSWD method enabled superior results in the subsequent fatigue detection across different levels of artifact contamination and evaluation criteria. SMR5 could be determined as the best fatigue detection algorithm. This study proposes a signal processing chain to determine neuromuscular fatigue despite the presence of cardiogenic artifacts. The results furthermore underline the importance of selecting a combination of algorithms that play well together to remove cardiogenic artifacts and to detect fatigue. This investigation provides guidance for clinical studies to select optimal signal processing to detect fatigue from respiratory sEMG signals.
- Open Access
- 1 September 2019
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 5 (1) , 357-359
Removal of ECG artifacts from EMG signals with different artifact magnitudes by template subtraction
This work investigates the performance of eventsynchronous noise cancelling algorithms to separate ECG artifacts from thoracic EMG recordings. In focus are the precise detection of heart beats, the exact time alignment of the QRS segments and the construction of a template QRS signal. Among the utilized methods is a modified structural intensity (SI) approach based on the observation of extrema in low pass filtered versions of the second derivative as a detector. An adoption of this approach is also used to obtain the exact time alignment of QRS segments. Artificial test signals are constructed based on addition of ECG and sEMG with different magnitudes. We show that approaches based on the observation of extrema in different scales yield superior results.
- 1 September 2019
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 5 (1) , 357-359
Open AccessRemoval of ECG artifacts from EMG signals with different artifact magnitudes by template subtraction
This work investigates the performance of eventsynchronous noise cancelling algorithms to separate ECG artifacts from thoracic EMG recordings. In focus are the precise detection of heart beats, the exact time alignment of the QRS segments and the construction of a template QRS signal. Among the utilized methods is a modified structural intensity (SI) approach based on the observation of extrema in low pass filtered versions of the second derivative as a detector. An adoption of this approach is also used to obtain the exact time alignment of QRS segments. Artificial test signals are constructed based on addition of ECG and sEMG with different magnitudes. We show that approaches based on the observation of extrema in different scales yield superior results.
- 7 October 2016
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 38 (11) , 1260-1269
Comparison of algorithms to quantify muscle fatigue in upper limb muscles based on sEMG signals
This work compared the performance of six different fatigue detection algorithms quantifying muscle fatigue based on electromyographic signals. Surface electromyography (sEMG) was obtained by an experiment from upper arm contractions at three different load levels from twelve volunteers. Fatigue detection algorithms mean frequency (MNF), spectral moments ratio (SMR), the wavelet method WIRM1551, sample entropy (SampEn), fuzzy approximate entropy (fApEn) and recurrence quantification analysis (RQA%DET) were calculated. The resulting fatigue signals were compared considering the disturbances incorporated in fatiguing situations as well as according to the possibility to differentiate the load levels based on the fatigue signals. Furthermore we investigated the influence of the electrode locations on the fatigue detection quality and whether an optimized channel set is reasonable. The results of the MNF, SMR, WIRM1551 and fApEn algorithms fell close together. Due to the small amount of subjects in this study significant differences could not be found. In terms of disturbances the SMR algorithm showed a slight tendency to out-perform the others.
- 7 October 2016
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 38 (11) , 1260-1269
Comparison of algorithms to quantify muscle fatigue in upper limb muscles based on sEMG signals
This work compared the performance of six different fatigue detection algorithms quantifying muscle fatigue based on electromyographic signals. Surface electromyography (sEMG) was obtained by an experiment from upper arm contractions at three different load levels from twelve volunteers. Fatigue detection algorithms mean frequency (MNF), spectral moments ratio (SMR), the wavelet method WIRM1551, sample entropy (SampEn), fuzzy approximate entropy (fApEn) and recurrence quantification analysis (RQA%DET) were calculated. The resulting fatigue signals were compared considering the disturbances incorporated in fatiguing situations as well as according to the possibility to differentiate the load levels based on the fatigue signals. Furthermore we investigated the influence of the electrode locations on the fatigue detection quality and whether an optimized channel set is reasonable. The results of the MNF, SMR, WIRM1551 and fApEn algorithms fell close together. Due to the small amount of subjects in this study significant differences could not be found. In terms of disturbances the SMR algorithm showed a slight tendency to out-perform the others.