Aya Abdalla
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Aya Abdalla has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
- Parastoo Hashemi
Department of Bioengineering, Imperial College London, London, United Kingdom
6 shared publications - Bhavik Anil Patel
University of Brighton
4 shared publications H. Frederik Nijhout
Department of Biology Duke University Durham North Carolina USA
3 shared publicationsSrimal Samaranayake
Department of Chemistry and Biochemistry, University of South Carolina , 631 Sumter Street, Columbia, South Carolina 29208, United States
3 shared publicationsAlyssa West
Department of Chemistry and Biochemistry University of South Carolina Columbia South Carolina USA
2 shared publicationsBeidi Qiang
Department of Mathematics and Statistics Southern Illinois University Edwardsville Edwardsville Illinois USA
2 shared publications
Latest Publications
- 1 September 2020
- Published by Elsevier in Electrochimica Acta
- Vol. 354
Augmentation of conductive pathways in carbon black/PLA 3D-printed electrodes achieved through varying printing parameters
- 1 September 2020
- Published by Elsevier in Electrochimica Acta
- Vol. 354
Augmentation of conductive pathways in carbon black/PLA 3D-printed electrodes achieved through varying printing parameters
- 7 July 2020
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 5 (9) , 2858-2865
Ex Vivo Electrochemical pH Mapping of the Gastrointestinal Tract in the Absence and Presence of Pharmacological Agents
Ex vivo pH profiling of the upper gastrointestinal (GI) tract (of a mouse), using an electrochemical pH probe, in both the absence and presence of pharmacological agents aimed at altering acid/bicarbonate production, is reported. Three pH electrodes were first assessed for suitability using a GI tract biological mimic buffer solution containing 0.5% mucin. These include a traditional glass pH probe, an iridium oxide (IrOx)-coated electrode (both operated potentiometrically), and a quinone (Q) surface-integrated boron-doped diamond (BDD-Q) electrode (voltammetric). In mucin, the time scale for both IrOx and glass to provide a representative pH reading was in the ∼100’s of s, most likely due to mucin adsorption, in contrast to 6 s with the BDD-Q electrode. Both the glass and IrOx pH electrodes were also compromised on robustness due to fragility and delamination (IrOx) issues; contact with the GI tissue was an experimental requirement. BDD-Q was deemed the most appropriate. Ten measurements were made along the GI tract, esophagus (1), stomach (5), and duodenum (4). Under buffer only conditions, the BDD-Q probe tracked the pH from neutral in the esophagus to acidic in the stomach and rising to more alkaline in the duodenum. In the presence of omeprazole, a proton pump inhibitor, the body regions of the stomach exhibited elevated pH levels. Under melatonin treatment (a bicarbonate agonist and acid inhibitor), both the body of the stomach and the duodenum showed elevated pH levels. This study demonstrates the versatility of the BDD-Q pH electrode for real-time ex vivo biological tissue measurements.
- 7 July 2020
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 5 (9) , 2858-2865
Ex Vivo Electrochemical pH Mapping of the Gastrointestinal Tract in the Absence and Presence of Pharmacological Agents
Ex vivo pH profiling of the upper gastrointestinal (GI) tract (of a mouse), using an electrochemical pH probe, in both the absence and presence of pharmacological agents aimed at altering acid/bicarbonate production, is reported. Three pH electrodes were first assessed for suitability using a GI tract biological mimic buffer solution containing 0.5% mucin. These include a traditional glass pH probe, an iridium oxide (IrOx)-coated electrode (both operated potentiometrically), and a quinone (Q) surface-integrated boron-doped diamond (BDD-Q) electrode (voltammetric). In mucin, the time scale for both IrOx and glass to provide a representative pH reading was in the ∼100’s of s, most likely due to mucin adsorption, in contrast to 6 s with the BDD-Q electrode. Both the glass and IrOx pH electrodes were also compromised on robustness due to fragility and delamination (IrOx) issues; contact with the GI tissue was an experimental requirement. BDD-Q was deemed the most appropriate. Ten measurements were made along the GI tract, esophagus (1), stomach (5), and duodenum (4). Under buffer only conditions, the BDD-Q probe tracked the pH from neutral in the esophagus to acidic in the stomach and rising to more alkaline in the duodenum. In the presence of omeprazole, a proton pump inhibitor, the body regions of the stomach exhibited elevated pH levels. Under melatonin treatment (a bicarbonate agonist and acid inhibitor), both the body of the stomach and the duodenum showed elevated pH levels. This study demonstrates the versatility of the BDD-Q pH electrode for real-time ex vivo biological tissue measurements.
- Open Access
- 20 May 2020
- Published by American Chemical Society (ACS) in ChemRxiv
Ex-vivo Electrochemical pH Mapping of the Gastrointestinal Tract in the Absence and Presence of Pharmacological Agents
Ex-vivo pH profiling of the upper gastrointestinal (GI) tract (of a mouse) in both the absence and presence of pharmacological agents aimed at altering acid/bicarbonate production, is reported using an electrochemical pH probe, for the first time. Three pH electrodes were assessed for suitability using a GI tract biological mimic buffer solution containing 0.5 % mucin. These include a traditional glass pH probe, an iridium oxide (IrOx) coated electrode (both potentiometric) and a quinone (Q) surface-integrated boron doped diamond (BDD-Q) electrode (voltammetric). In mucin the timescale for both IrOx and glass to obtain stable pH readings was in the ~100’s of s, most likely due to mucin adsorption, in contrast to 6 s with the BDD-Q electrode. Both the glass and IrOx pH electrodes were also compromised on robustness due to fragility and delamination (IrOx); contact with the GI tissue was an experimental requirement. BDD-Q was deemed the most appropriate. Ten measurements were made along the GI tract, esophagus (1), stomach (5) and duodenum (4). Under untreated conditions (buffer only), the BDD-Q probe tracked the pH from neutral in the esophagus, to acidic in the stomach and rising to more alkaline in the duodenum. In the presence of omeprazole, a proton pump inhibitor, the body regions of the stomach exhibited elevated pH levels. Under melatonin treatment (a bicarbonate agonist and acid inhibitor), both the body of the stomach and the duodenum showed elevated pH levels. This study demonstrates the versatility of the BDD-Q pH electrode for real-time ex-vivo biological tissue measurements.
- 20 May 2020
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessEx-vivo Electrochemical pH Mapping of the Gastrointestinal Tract in the Absence and Presence of Pharmacological Agents
Ex-vivo pH profiling of the upper gastrointestinal (GI) tract (of a mouse) in both the absence and presence of pharmacological agents aimed at altering acid/bicarbonate production, is reported using an electrochemical pH probe, for the first time. Three pH electrodes were assessed for suitability using a GI tract biological mimic buffer solution containing 0.5 % mucin. These include a traditional glass pH probe, an iridium oxide (IrOx) coated electrode (both potentiometric) and a quinone (Q) surface-integrated boron doped diamond (BDD-Q) electrode (voltammetric). In mucin the timescale for both IrOx and glass to obtain stable pH readings was in the ~100’s of s, most likely due to mucin adsorption, in contrast to 6 s with the BDD-Q electrode. Both the glass and IrOx pH electrodes were also compromised on robustness due to fragility and delamination (IrOx); contact with the GI tissue was an experimental requirement. BDD-Q was deemed the most appropriate. Ten measurements were made along the GI tract, esophagus (1), stomach (5) and duodenum (4). Under untreated conditions (buffer only), the BDD-Q probe tracked the pH from neutral in the esophagus, to acidic in the stomach and rising to more alkaline in the duodenum. In the presence of omeprazole, a proton pump inhibitor, the body regions of the stomach exhibited elevated pH levels. Under melatonin treatment (a bicarbonate agonist and acid inhibitor), both the body of the stomach and the duodenum showed elevated pH levels. This study demonstrates the versatility of the BDD-Q pH electrode for real-time ex-vivo biological tissue measurements.
- 1 April 2020
- Published by Elsevier in Current Opinion in Electrochemistry
- Vol. 20, 78-81
3D-printed electrochemical sensors: A new horizon for measurement of biomolecules
- 1 April 2020
- Published by Elsevier in Current Opinion in Electrochemistry
- Vol. 20, 78-81
3D-printed electrochemical sensors: A new horizon for measurement of biomolecules
- 28 November 2019
- Published by Wiley in Journal of Neurochemistry
- Vol. 153 (1) , 33-50
Fast serotonin voltammetry as a versatile tool for mapping dynamic tissue architecture: I. Responses at carbon fibers describe local tissue physiology
It is important to monitor serotonin neurochemistry in the context of brain disorders. Specifically, a better understanding of biophysical alterations and associated biochemical functionality within subregions of the brain will enable better of understanding of diseases such as depression. Fast voltammetric tools at carbon fiber microelectrodes provide an opportunity to make direct evoked and ambient serotonin measurements in vivo in mice. In this study, we characterize novel stimulation and measurement circuitries for serotonin analyses in brain regions relevant to psychiatric disease. Evoked and ambient serotonin in these brain areas, the CA2 region of the hippocampus and the medial prefrontal cortex, are compared to ambient and evoked serotonin in the substantia nigra pars reticulata, an area well established previously for serotonin measurements with fast voltammetry. Stimulation of a common axonal location evoked serotonin in all three brain regions. Differences are observed in the serotonin release and reuptake profiles between these three brain areas which we hypothesize to arise from tissue physiology heterogeneity around the carbon fiber microelectrodes. We validate this hypothesis mathematically and via confocal imaging. We thereby show that fast voltammetric methods can provide accurate information about local physiology and highlight implications for chemical mapping. image Cover Image for this issue: doi: 10.1111/jnc.14739.
- 28 November 2019
- Published by Wiley in Journal of Neurochemistry
- Vol. 153 (1) , 33-50
Fast serotonin voltammetry as a versatile tool for mapping dynamic tissue architecture: I. Responses at carbon fibers describe local tissue physiology
It is important to monitor serotonin neurochemistry in the context of brain disorders. Specifically, a better understanding of biophysical alterations and associated biochemical functionality within subregions of the brain will enable better of understanding of diseases such as depression. Fast voltammetric tools at carbon fiber microelectrodes provide an opportunity to make direct evoked and ambient serotonin measurements in vivo in mice. In this study, we characterize novel stimulation and measurement circuitries for serotonin analyses in brain regions relevant to psychiatric disease. Evoked and ambient serotonin in these brain areas, the CA2 region of the hippocampus and the medial prefrontal cortex, are compared to ambient and evoked serotonin in the substantia nigra pars reticulata, an area well established previously for serotonin measurements with fast voltammetry. Stimulation of a common axonal location evoked serotonin in all three brain regions. Differences are observed in the serotonin release and reuptake profiles between these three brain areas which we hypothesize to arise from tissue physiology heterogeneity around the carbon fiber microelectrodes. We validate this hypothesis mathematically and via confocal imaging. We thereby show that fast voltammetric methods can provide accurate information about local physiology and highlight implications for chemical mapping. image Cover Image for this issue: doi: 10.1111/jnc.14739.
- Open Access
- 16 September 2019
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 144 (20) , 6011-6018
Determination of tryptophan metabolism from biological tissues and fluids using high performance liquid chromatography with simultaneous dual electrochemical detection
Our study develops a methodology for monitoring of analytes from the kynurenine and serotonin pathway following tryptophan metabolism.
- 16 September 2019
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 144 (20) , 6011-6018
Open AccessDetermination of tryptophan metabolism from biological tissues and fluids using high performance liquid chromatography with simultaneous dual electrochemical detection
Our study develops a methodology for monitoring of analytes from the kynurenine and serotonin pathway following tryptophan metabolism.
- 1 February 2019
- Published by Elsevier in Neurochemistry International
- Vol. 123, 50-58
Voltammetric evidence for discrete serotonin circuits, linked to specific reuptake domains, in the mouse medial prefrontal cortex
- 1 February 2019
- Published by Elsevier in Neurochemistry International
- Vol. 123, 50-58
Voltammetric evidence for discrete serotonin circuits, linked to specific reuptake domains, in the mouse medial prefrontal cortex
- 1 November 2018
- Published by Elsevier in Electrochemistry Communications
- Vol. 96, 27-31
3D printable conductive materials for the fabrication of electrochemical sensors: A mini review
- 1 November 2018
- Published by Elsevier in Electrochemistry Communications
- Vol. 96, 27-31
3D printable conductive materials for the fabrication of electrochemical sensors: A mini review
- 10 August 2017
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 89 (18) , 9703-9711
In Vivo Ambient Serotonin Measurements at Carbon-Fiber Microelectrodes
The mechanisms that control extracellular serotonin levels in vivo are not well-defined. This shortcoming makes it very challenging to diagnose and treat the many psychiatric disorders in which serotonin is implicated. Fast-scan cyclic voltammetry (FSCV) can measure rapid serotonin release and reuptake events but cannot report critically important ambient serotonin levels. In this Article, we use fast-scan controlled adsorption voltammetry (FSCAV), to measure serotonin’s steady-state, extracellular chemistry. We characterize the “Jackson” voltammetric waveform for FSCAV and show highly stable, selective, and sensitive ambient serotonin measurements in vitro. In vivo, we report basal serotonin levels in the CA2 region of the hippocampus as 64.9 ± 2.3 nM (n = 15 mice, weighted average ± standard error). We electrochemically and pharmacologically verify the selectivity of the serotonin signal. Finally, we develop a statistical model that incorporates the uncertainty in in vivo measurements, in addition to electrode variability, to more critically analyze the time course of pharmacological data. Our novel method is a uniquely powerful analysis tool that can provide deeper insights into the mechanisms that control serotonin’s extracellular levels.
- 10 August 2017
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 89 (18) , 9703-9711
In Vivo Ambient Serotonin Measurements at Carbon-Fiber Microelectrodes
The mechanisms that control extracellular serotonin levels in vivo are not well-defined. This shortcoming makes it very challenging to diagnose and treat the many psychiatric disorders in which serotonin is implicated. Fast-scan cyclic voltammetry (FSCV) can measure rapid serotonin release and reuptake events but cannot report critically important ambient serotonin levels. In this Article, we use fast-scan controlled adsorption voltammetry (FSCAV), to measure serotonin’s steady-state, extracellular chemistry. We characterize the “Jackson” voltammetric waveform for FSCAV and show highly stable, selective, and sensitive ambient serotonin measurements in vitro. In vivo, we report basal serotonin levels in the CA2 region of the hippocampus as 64.9 ± 2.3 nM (n = 15 mice, weighted average ± standard error). We electrochemically and pharmacologically verify the selectivity of the serotonin signal. Finally, we develop a statistical model that incorporates the uncertainty in in vivo measurements, in addition to electrode variability, to more critically analyze the time course of pharmacological data. Our novel method is a uniquely powerful analysis tool that can provide deeper insights into the mechanisms that control serotonin’s extracellular levels.