Joan Kangro
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Joan Kangro has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Daniele Pucci
Artificial and Mechanical Intelligence, Istituto Italiano di Tecnologia, Genoa, Italy
2 shared publications - Francesco Nori
Istituto Italiano di Tecnologia
2 shared publications - Silvio Traversaro
Artificial and Mechanical Intelligence, Istituto Italiano di Tecnologia, Genoa, Italy
2 shared publications Anand Vazhapilli Sureshbabu
Italian Institute of Technology, Genova, Italy
1 shared publication- Francisco Javier Andrade Chavez
Dynamic Interaction Control at Istituto Italiano di Tecnologia Center for Robotics and Intelligent Systems Via San Quirico 19D Genoa Italy
1 shared publication
Latest Publications
- 20 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 3 (4) , 3937-3943
A Plenum-Based Calibration Device for Tactile Sensor Arrays
In modern robotic applications, tactile sensor arrays (i.e., artificial skins) are an emergent solution to determine the locations of contacts between a robot and an external agent. Localizing the point of contact is useful but determining the force applied on the skin provides many additional possibilities. This additional feature usually requires time-consuming calibration procedures to relate the sensor readings to the applied forces. This letter presents a novel device that enables the calibration of tactile sensor arrays in a fast and simple way. The key idea is to design a plenum chamber where the skin is inserted, and then the calibration of the tactile sensors is achieved by relating the air pressure and the sensor readings. This general concept is tested experimentally to calibrate the skin of the iCub robot. The validation of the calibration device is achieved by placing the masses of known weight on the artificial skin and comparing the applied force against the one estimated by the sensors.
- 20 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 3 (4) , 3937-3943
A Plenum-Based Calibration Device for Tactile Sensor Arrays
In modern robotic applications, tactile sensor arrays (i.e., artificial skins) are an emergent solution to determine the locations of contacts between a robot and an external agent. Localizing the point of contact is useful but determining the force applied on the skin provides many additional possibilities. This additional feature usually requires time-consuming calibration procedures to relate the sensor readings to the applied forces. This letter presents a novel device that enables the calibration of tactile sensor arrays in a fast and simple way. The key idea is to design a plenum chamber where the skin is inserted, and then the calibration of the tactile sensors is achieved by relating the air pressure and the sensor readings. This general concept is tested experimentally to calibrate the skin of the iCub robot. The validation of the calibration device is achieved by placing the masses of known weight on the artificial skin and comparing the applied force against the one estimated by the sensors.
- 18 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 3 (4) , 3900-3907
Contact Force and Joint Torque Estimation Using Skin
In this letter, we present algorithms to estimate contact locations, external forces, and joint torques using skin, i.e., distributed tactile sensors, kinematic sensors, and a single Inertial Measurement Unit (IMU) without the need for force-torque sensors. Distributed tactile sensors are an array of discrete tactile sensors (taxels) with gaps between them. To cope with the gaps, we use interpolation techniques to improve accuracy of the measurements in the skin. Then, we estimate the external force. Finally, we use this information combined with the contact location obtained from the skin to estimate the joint torques. Validation was performed using the iCub humanoid robot. Results show a performance comparable to the joint torque estimation using expensive force-torque sensors. Since the skin is less expensive and does not require modification of the internal structure of the robot, using the skin is an interesting solution.
- 18 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 3 (4) , 3900-3907
Contact Force and Joint Torque Estimation Using Skin
In this letter, we present algorithms to estimate contact locations, external forces, and joint torques using skin, i.e., distributed tactile sensors, kinematic sensors, and a single Inertial Measurement Unit (IMU) without the need for force-torque sensors. Distributed tactile sensors are an array of discrete tactile sensors (taxels) with gaps between them. To cope with the gaps, we use interpolation techniques to improve accuracy of the measurements in the skin. Then, we estimate the external force. Finally, we use this information combined with the contact location obtained from the skin to estimate the joint torques. Validation was performed using the iCub humanoid robot. Results show a performance comparable to the joint torque estimation using expensive force-torque sensors. Since the skin is less expensive and does not require modification of the internal structure of the robot, using the skin is an interesting solution.