SNSreenath Narayan

Sreenath Narayan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Sreenath Narayan has a total of 5 co-authors. Here are the top co-authors by number of shared publications:

  • David L. Wilson

    Department of Biomedical Engineering, Case Western Reserve University

    2 shared publications
  • Satish C. Kalhan

    Department of Molecular Medicine, Cleveland Clinic, Lerner College of Medicine of Case Western Reserve University, Cleveland, OH, USA

    2 shared publications
  • Ashwini Nayak

    Case Western Reserve University School of Medicine, Louis Stokes Cleveland VA Medical Center, Cleveland, OH 44106, USA

    1 shared publication
  • Chris A. Flask

    Department of Biomedical Engineering, Case Western Reserve University

    1 shared publication
  • Chris L. King

    Case Western Reserve University School of Medicine, Louis Stokes Cleveland VA Medical Center, Cleveland, OH 44106, USA

    1 shared publication

Latest Publications

  • Open Access

    Inflammatory Pseudotumor of the Liver withEscherichia coliin the Sputum

    by Sreenath Narayan, Ashwini Nayak, Chris L. King

    Inflammatory pseudotumor is a nonmalignant lesion that mimics malignant lesions and has been reported to occur at various sites throughout the body. Though it has been reported as a reaction to infection, the true etiology of the lesion is unknown. In this report, we present the case of a patient with a liver lesion of unknown origin. Through a series of imaging studies, we were able to observe the locally aggressive nature of this lesion as it rapidly eroded into the lung. Sputum cultures showed growth of E. coli, indicating E. coli infection as a possible etiology of this lesion. Pathology was consistent with inflammatory pseudotumor. Inflammatory pseudotumor is a nonmalignant lesion that mimics malignant lesions and has been reported to occur at various sites throughout the body. Though it has been reported as a reaction to infection, the true etiology of the lesion is unknown. In this report, we present the case of a patient with a liver lesion of unknown origin. Through a series of imaging studies, we were able to observe the locally aggressive nature of this lesion as it rapidly eroded into the lung. Sputum cultures showed growth of E. coli, indicating E. coli infection as a possible etiology of this lesion. Pathology was consistent with inflammatory pseudotumor.


  • Open Access

    Hepatic fat during fasting and refeeding by MRI fat quantification.

    by Sreenath Narayan, Chris A. Flask, Satish C. Kalhan, David L. Wilson


  • Open Access

    Recovery of chemical estimates by field inhomogeneity neighborhood error detection (REFINED): Fat/Water separation at 7 tesla

    by Sreenath Narayan, Satish C. Kalhan, David L. Wilson

    Purpose: To reduce swaps in fat–water separation methods, a particular issue on 7 Tesla (T) small animal scanners due to field inhomogeneity, using image postprocessing innovations that detect and correct errors in the B0 field map. Materials and Methods: Fat–water decompositions and B0 field maps were computed for images of mice acquired on a 7T Bruker BioSpec scanner, using a computationally efficient method for solving the Markov Random Field formulation of the multi‐point Dixon model. The B0 field maps were processed with a novel hole‐filling method, based on edge strength between regions, and a novel k‐means method, based on field‐map intensities, which were iteratively applied to automatically detect and reinitialize error regions in the B0 field maps. Errors were manually assessed in the B0 field maps and chemical parameter maps both before and after error correction. Results: Partial swaps were found in 6% of images when processed with FLAWLESS. After REFINED correction, only 0.7% of images contained partial swaps, resulting in an 88% decrease in error rate. Complete swaps were not problematic. Conclusion: Ex post facto error correction is a viable supplement to a priori techniques for producing globally smooth B0 field maps, without partial swaps. With our processing pipeline, it is possible to process image volumes rapidly, robustly, and almost automatically. J. Magn. Reson. Imaging 2013;37:1247–1253.