Caroline C. O'Brien
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Caroline C. O'Brien has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Elazer Reuven Edelman
Harvard Medical School
3 shared publications - Vijaya B. Kolachalama
Department of Medicine, Boston University Chobanian & Avedisian School of Medicine, MA
3 shared publications Augusto C. Lopes
Institute of Medical Engineering and Science, Massachusetts Institute of Technology, Cambridge, MA, United States of America
2 shared publications- Jonathan Brown
Institute of Medical Engineering and Science, Massachusetts Institute of Technology, Cambridge, MA, USA
2 shared publications Kumaran Kolandaivelu
Institute of Medical Engineering and Science, Massachusetts Institute of Technology, Cambridge, MA, United States of America
2 shared publicationsMie Kunio
Institute of Medical Engineering and Science, Massachusetts Institute of Technology, Cambridge, MA, United States of America
2 shared publications
Latest Publications
- Open Access
- 23 February 2016
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 11 (2) , e0149178
Constraining OCT with Knowledge of Device Design Enables High Accuracy Hemodynamic Assessment of Endovascular Implants
Stacking cross-sectional intravascular images permits three-dimensional rendering of endovascular implants, yet introduces between-frame uncertainties that limit characterization of device placement and the hemodynamic microenvironment. In a porcine coronary stent model, we demonstrate enhanced OCT reconstruction with preservation of between-frame features through fusion with angiography and a priori knowledge of stent design. Strut positions were extracted from sequential OCT frames. Reconstruction with standard interpolation generated discontinuous stent structures. By computationally constraining interpolation to known stent skeletons fitted to 3D ‘clouds’ of OCT-Angio-derived struts, implant anatomy was resolved, accurately rendering features from implant diameter and curvature (n = 1 vessels, r2 = 0.91, 0.90, respectively) to individual strut-wall configurations (average displacement error ~15 μm). This framework facilitated hemodynamic simulation (n = 1 vessel), showing the critical importance of accurate anatomic rendering in characterizing both quantitative and basic qualitative flow patterns. Discontinuities with standard approaches systematically introduced noise and bias, poorly capturing regional flow effects. In contrast, the enhanced method preserved multi-scale (local strut to regional stent) flow interactions, demonstrating the impact of regional contexts in defining the hemodynamic consequence of local deployment errors. Fusion of planar angiography and knowledge of device design permits enhanced OCT image analysis of in situ tissue-device interactions. Given emerging interests in simulation-derived hemodynamic assessment as surrogate measures of biological risk, such fused modalities offer a new window into patient-specific implant environments.
- 23 February 2016
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 11 (2) , e0149178
Open AccessConstraining OCT with Knowledge of Device Design Enables High Accuracy Hemodynamic Assessment of Endovascular Implants
Stacking cross-sectional intravascular images permits three-dimensional rendering of endovascular implants, yet introduces between-frame uncertainties that limit characterization of device placement and the hemodynamic microenvironment. In a porcine coronary stent model, we demonstrate enhanced OCT reconstruction with preservation of between-frame features through fusion with angiography and a priori knowledge of stent design. Strut positions were extracted from sequential OCT frames. Reconstruction with standard interpolation generated discontinuous stent structures. By computationally constraining interpolation to known stent skeletons fitted to 3D ‘clouds’ of OCT-Angio-derived struts, implant anatomy was resolved, accurately rendering features from implant diameter and curvature (n = 1 vessels, r2 = 0.91, 0.90, respectively) to individual strut-wall configurations (average displacement error ~15 μm). This framework facilitated hemodynamic simulation (n = 1 vessel), showing the critical importance of accurate anatomic rendering in characterizing both quantitative and basic qualitative flow patterns. Discontinuities with standard approaches systematically introduced noise and bias, poorly capturing regional flow effects. In contrast, the enhanced method preserved multi-scale (local strut to regional stent) flow interactions, demonstrating the impact of regional contexts in defining the hemodynamic consequence of local deployment errors. Fusion of planar angiography and knowledge of device design permits enhanced OCT image analysis of in situ tissue-device interactions. Given emerging interests in simulation-derived hemodynamic assessment as surrogate measures of biological risk, such fused modalities offer a new window into patient-specific implant environments.
- Open Access
- 5 January 2016
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 44 (7) , 2251-2260
Vascular Response to Experimental Stent Malapposition and Under-Expansion
Up to 80% of all endovascular stents have malapposed struts, and while some impose catastrophic events others are inconsequential. Thirteen stents were implanted in coronary arteries of seven healthy Yorkshire pigs, using specially-designed cuffed balloons inducing controlled stent malapposition and under-expansion. Optical coherence tomography (OCT) imaging confirmed that 25% of struts were malapposed (strut-wall distance malapposed group 0.51 ± 0.05 mm vs. apposed group 0.09 ± 0.05 mm, p = 2e−3). Imaging at follow-up revealed malapposition acutely resolved (p < 0.0001, R 2 = 0.94). OCT in three of the most significantly malapposed vessels at baseline showed high correlation of elastic lamina area and lumen area (R 2 = 0.96) suggesting all lumen loss was related to contraction of elastic lamina with negligible plaque/intimal hyperplasia growth. Simulation showed this vascular recoil could be partially explained by the non-uniform strain environment created from sub-optimal expansion of device and balloon, and the inability of stent support in the malapposed region to resist recoil. Malapposition as a result of stent under-expansion is resolved acutely in healthy normal arteries, suggesting existing animal models are limited in replicating clinically observed persistent stent malapposition.
- 5 January 2016
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 44 (7) , 2251-2260
Open AccessVascular Response to Experimental Stent Malapposition and Under-Expansion
Up to 80% of all endovascular stents have malapposed struts, and while some impose catastrophic events others are inconsequential. Thirteen stents were implanted in coronary arteries of seven healthy Yorkshire pigs, using specially-designed cuffed balloons inducing controlled stent malapposition and under-expansion. Optical coherence tomography (OCT) imaging confirmed that 25% of struts were malapposed (strut-wall distance malapposed group 0.51 ± 0.05 mm vs. apposed group 0.09 ± 0.05 mm, p = 2e−3). Imaging at follow-up revealed malapposition acutely resolved (p < 0.0001, R 2 = 0.94). OCT in three of the most significantly malapposed vessels at baseline showed high correlation of elastic lamina area and lumen area (R 2 = 0.96) suggesting all lumen loss was related to contraction of elastic lamina with negligible plaque/intimal hyperplasia growth. Simulation showed this vascular recoil could be partially explained by the non-uniform strain environment created from sub-optimal expansion of device and balloon, and the inability of stent support in the malapposed region to resist recoil. Malapposition as a result of stent under-expansion is resolved acutely in healthy normal arteries, suggesting existing animal models are limited in replicating clinically observed persistent stent malapposition.
- Open Access
- 1 June 2013
- Published by Elsevier in Journal of Controlled Release
- Vol. 168 (2) , 115-124
Impact of flow pulsatility on arterial drug distribution in stent-based therapy
- 1 June 2013
- Published by Elsevier in Journal of Controlled Release
- Vol. 168 (2) , 115-124
Open AccessImpact of flow pulsatility on arterial drug distribution in stent-based therapy